Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹38.1 L+₹1.5 L (3.99%)Rejected-Finance FLAT NO 1 GURUKRUPA APARTMENT BEHIND TELEPHONE EXCHANGE DEHUROAD PUNE | PUNE | PUNE | MAHARASHTRA | 412101 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹38.2 L+₹1.6 L (4.27%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹39.0 L+₹2.4 L (6.47%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹39.0 L+₹2.4 L (6.57%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
26 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehu Road, Pune
GE Dehu Road, Pune
SPECIAL REPAIR TO BLDG NO T2 AND P3 KT LINE OF 787 I AD BDE SIG COY AND SPECIAL REAPIR TO BURNING PIT NO 01 AT ATA OF 29 FAD UNDER AGE BR EAST AT GE DEHU ROAD
2022_MES_525996_2
8634
Open Tender
Civil Works
Item Rate
270 days
GE Dehu Road, Pune
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Dehu Road, Pune
₹76,000
Yes
16 Aug 2022
1 Jul 2022
29 Jul 2022
1 Jul 2022
26 Jul 2022
14 Jul 2022
75 days
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
Dismanteling MS works of any desc. not otherwise provided for complete all as specified.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
All as per item no 3 above but fix in valley gutter / ridge,plain/corrugated.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.. conf to Fe-410-w(gdeE-250 quality-A)
-Ditto- item no 5 above but fixing only
Dismantling wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness incl. cover fillets and alum snip grid.
S & F Anodised Alu. snap grid (605x605)mm frame wk for false ceiling , providing M&L 9mm thick Acoustical board/tiles for insulation and accoustic purposes, (60x60) cm in size, fixed in celing with screws to frame work or with staples on snap grid, hangers 6 mm dia G.I. ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat (40 X 3) mm size 60 mm long complete all as specied and as directed.
Taking down cement or cement lime plaster on brick or stone walls , etc including raking out joints, hacking for key, scrubbing down with eater etc,complete all as specified.
Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plain exc. 6m mean radius built in CM 1:6
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces finished even and smooth in cement mortar 1:6, complete all as specified
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces finished even and smooth in cement mortar 1:4, complete all as specified
M & L for Preparation of new previously plastered or unplastered surfaces of walls and applying two coats of oil bound distemper in approved colour/ shade over a coat of chalk whiting primer after preparation of surfaces complete.
M & L for Preparation of old previously plastered or unplastered surfaces of walls and applying one coats of oil bound distemper in approved colour/ shade over a coat of chalk whiting primer after preparation of surfaces complete.
M&L for preparation of surfaces of new plaster surface of wall and applying two coat of cement base paint complete all as specified and directed.
M&L for preparation of surfaces of old plaster surface of wall and applying one coat of cement base paint complete all as specified and directed.
Taking down Chowkat/frame exc 1.5 sq.m & n.exc 4 sq.m including removing to store,complete all as specified.
Taking down Shutters of any description exc 1 Sqm and n exc 2 sq. m each and removing to store,complete all as specified.
Taking down Chowkat/frame n.exc 1.5 sq.m each complete all as specified.
S&F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 125 X 60mm.
M & L for 35 mm thick second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified.
S & F factory made 35 mm thick glazed & skeleton shutter of 2nd class hard wood open rebated and prepared to receive gauge (divided into squares with sash bars) edges of framing plain chamfered or rounded, fitted without & fitted beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I Sec-8 clause 8.23 (a) and fitted to chowkhats complete all as specified.
S & F Butt hinges 100 mm size medium weight cold rolled mild steel and fixed, complete all as specified
S & F Extruded Aluminium alloy handles, fabricated type, anodised 125 mm size, complete all as specified
S & F 150 mm mild steel tower bolt, ISI marks, stone enameled black with bright bolt and fixed, complete all as specified
S & F 250 mm aluminum anodized sliding door bolts, ISI marked, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed
S and F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete
S & F Galvanized mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples
M&L for one coats synthetic enamelled paint incl preparation of old steel surfaces of any description over 10cm width or girth complete all as specifed and as directed
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protections, finished even and smooth w/o using extra cement
S & F powder coated aluminum frame for doors, windows & ventilators with one or more rebate inlcuding jointing cleats and alike for fixing complete
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, srews with powder coating of any colour (Thickness or powder coating not less than 50 micron) including stainless steel wirecloth 0.36 mm nominal dia of wire and average aperture 1.40 mm and fixed with stanless steel wire staples. and 3.0 mm th sheet glass ordinary quality plain and glazing Complete all as specified and directed.
Supply & Fixing PVC door frame (50x47) mm made out of plain colour 5 mm thich PVC Sheet re in forced with MS Square Tube, supplying & fixing in opening as per specification & drawing all as specified.
S&F factory made solid panel PVC door shutter 30 mm thick ( Style ) consisting of frame made out of MS Tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC ' C 'Channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC Sheets for top rail , lock rail & bottomrail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC Sheet to be fitted in the MS Frame welded / sealed to stiles & rails with suitable PVC Sheet beading, jointed together with solvent cement,supplying & fixing in the frame at site as per specification & drawing all as specified.
Demolition of concrete ( un reinforced ) in ground floors and paving n.exc 15 cm thk (below or above ground level)
S&F in repairs 25mm chromium plated aluminium alloy anodised curtain rod fixed to brackets complete all as specified and directed.
M & L 25mm thick PCC 1:2:4 type B1 (20 mm Graded Agg ) as in sub base complete all as specified.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed.
All as per item No 41 above but on skirtings incl 10 mm th rendering in CM (1:4) complete.
M & L 75mm thick PCC type D2 1:4:8 (40 mm Gr. Agg ) as in sub base complete all as specified.
M& L Chequared Cement Concrete Tiles 20 CM x 20 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over & including screed bed 15 mm thk in cm (1:6) complete all as specified.
M &L for MS work as in wind tie or any other work including cutting, drilling holes etc.
Dismantling floor hearth or wall tiling incl cement mortar bedding/plaster (but not backing) and removing rubbish off the premises etc complete all as directed.
M&L for glazed coloured ceramic tiles 350 mm x 250mm/450mmx350x7 to 7 mm thick as in vertical surfces set & jointed in neat cement slurry & pointed in coloured cement incl backing coat 10mm thick in CM 1:4 all as direced.
S & F in Repair rotational moulded polyethylene water storage tank of 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
M&L for Non-skid coloured Ceramic tiles of size 300 x 450 mm or 300 x 350 mm 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over & including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified.
S&F 10 litre as in repairs PVC low/high level flushing cistern white incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl bracats fixed in repairs all as directed. (Note:- Removing existing fluhing system of CI or any other quality incl brackets).
S & F Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms)
S & F for PVC connections 15mm size with PTMT nuts of length 450 mm
S/F in repairs Vitreous china wash basin white flat back size 550 x 400mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and PVC waste pipe complete all as directed.
S&F vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistern & fush pipe fixed in repairs completed as directed.
S&F 15mm dia in repairs bib taps cast copper alloy with capstan heads screwed down, screwed for iron pipe or for brass furrule and fixed all as directed.
S&F 15 mm dia in repairs pillar taps fancy type ,chromium plated with capstan heads screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as directed.
S&F 125mm dia in repairs Brass cromium plated with capstan heads shower rose of dia complete all as specified & directed.
S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S & F Push taps 15 mm dia of any colour of PTMT for urinals and fixed in repair.
S & F for 15 mm dia Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms
Taking up or down steel tubes and connections including cleaning for refixing or removal to stones bore of pipe 15mm dia.
All as per item No. 62 above but bore of pipe 20mm
M&L 15 mm dia GI tubes, medium grade with all fittings and fixed complete to walls, ceiling or laid in floors, complete & all as derected.
All as per item No. 64 above but bore of pipe 20mm dia pipe all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm dia bore PVC (SWR) bends with access door any radius
S & F 110mm bore PVC (SWR) 110 mm bore vent cowel complete.
Demolition and breaking up drain pipes (salt glazed ware) 100 mm dia set in cement mortor complete all as specified.
Demolition and breaking up drain pipes (salt glazed ware) 150 mm dia set in cement mortor complete all as specified.
Demolition of and breaking up drain pipes (salt glazed ware) 200 mm dia set in cement mortor complete all as specified.
Excavation over areas, n exc 1.5 m deep and getting out Soft /Loose soil
item No 72 above but each additional 1.5 m or part thereof in depth beyond the first 1.5m depth in hard dense soil.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in Soft / loose soil complete all as specified and directed. Note :- Excavation & Earth work will paid under respective items.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
M&L for Hardcore (Broken stone or boulders) of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to true surface as specified and as directed by Engineer-in-Charge.
M&L for Brick work with subclass 'B' brick straight or curved on plan 6m mean radius built in CM (1:6) etc as directed .
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces finished even and smooth in cement mortar 1:4, ( using Integral waterproofing compound ) complete all as specified
Supply only Integral water proofing compound
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling in mass concrete complete all as specified and directed by Engr-in-Charge.
Demolition of Re-inforced Cement Concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M&L for providing reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone agg) as in cover slab for manholes & septic tanks with plane face set in CM (1:6) complete all as directed by Engr-in-charge.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for 100 mm internal dia salt glazed stone ware pipe Grade 'A' laid in trenches and jointed all as specified.
M & L for cement concrete (1:3:6) type C-2 stone aggregate as in bed to drain pipes of 100 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M&L for 150 mm internal dia salt glazed stone ware pipe Grade 'A' laid in trenches and jointed all as specified.
M& L for PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in bed of drain for 150mm bore pipe incl packing under and completely surrounding pipes with concrete after they are laid and tested for 150mm dia pipes complete all as specified and directed by Engr-in-Charge.
M&L for 200 mm internal dia salt glazed stone ware pipe Grade 'A' laid in trenches and jointed all as specified.
M& L for PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in bed of drain for 200mm bore pipe incl packing under and completely surrounding pipes with concrete after they are laid and tested for 200mm dia pipes complete all as specified and directed by Engr-in-Charge.
M & L for plain cement concrete (1:2:4 ) Type B-2 (using 40 mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed by Engr-in-Charge.
M & L for MS work as in plate (plain or chequred) square cut or notched forming holes without any attachment complete allas specified and as directed.
S&F framed work such as grill , grating etc with ends of bar shoulder and /or rivated or fored into spilkes, framed guard bar conforming to FE-410-W (GdeE 250 ) quality A complete all as specified and as directed
M&L for expanded metal, n.exc 4kg kper sqm, cut to length, bent to shape required and typing with and including annealed mild steeel wire not less than 0.9mm dai or fixing with galvanised steel staples supplied and fixed complete to wood or steel members.
M&L applying two coats of oil bound distemper over one coat of primer and putty (Approved quality) including preparation of newly plastered surfaces of walls complete all as specified and as directed.
M&L cement concrete (1:2:4) type B-1, (20mm graded agg) 75mm thickness complete all as specified and as directed
M&L for water proofing treatment using polymerised membrane to roof slab. Water proofing treatment shall be as under :- (a) The roof surface shall be thoroughly wire brushed, washed, dried up & cleaned to remove all foreign materials & dust to receive primer. (b) Top surface shall be applied with 0.15 Kg/Sqm bitumenous aluminium 2 coats of paint. (c) Rendering 10mm thick in CM 1:4 on concrete surfaces / slabs with admixture of incl admixature of as per manufacture recommendation(WPC to be measured seperately) finished even and smooth. (d) Taking out existing water proofing treatment including cement plaster(any no of layers) on roof surfaces, cleaning the surfaces removing the debris outside MOD land. (e) 3mm thick applying cold bitumenous oil based primer IS No 3383 @ 250 Gms/Sqm and laying APP Modified membrane with non woven polymer reinforcement / mat core (Centre core) not less than 3.60kg/sqm the overlap shall be 100 mm on length side and 100 mm on width side and all as per manufacturer instruction complete.
M&L for laying machine pressed precast concrete interlocking coloured pavers block any shape and size confirming to IS 15658-2006 of 60mm thick, M-35 Grade over 50mm thick sand layer watering and ramming all as specified.
S & F in repair for Steeledge M3 1 Ton 3m single fall alloy steel manual chain pullay block including complete accessories all as specified.
E&M PORTION
M&L for point wiring with 1.5 sqmm multistranded copper conductor cable of PVC insulated and unsheahed type alongwith 1.5sqmm PVC insulated unsheathed single stranded copper conductor cable for continous earthing in & incl casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/(MS steel strips if required) including hard PVC boards of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator setc for Note:- Screws used for fixing PVC boards, casing & caping ceilling rose square blocks etc should be nickel cadmium screws :-
(a) One light point controlled by one switch
(b) One fan point controlled by one switch & regulators
(f) One socket 5 pin 5 Amps flush type on independent board
(f) One socket 5 pin 5 Amps flush type on same board
M&L for point wiring with 2.5 sqmm single core multistranded copper conductor cable of PVC insulated and unsheathed type alongwith 2.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc for Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing
S & F in repair submain wiring with cable insulated single core multistranded copper conductor cable 1100 volts 2x 4 sqmm drawn through & incl PVC casing caping / PVC conduit of suitable size alongwith 2.5 sqmm copper conductor cable for earth continuity. (Note : 2 runs of 4.0 sqmm cable, one run of 2.5 sqmm cable and one run of PVC casing capping will be measured as one RM).
S&F switch piano flush type single pole one way 5 Amps
S&F switch socket combination 2 in 1, 5 Amps flush type
S&F switch socket combination 2 in 1, 15 Amps flush type
S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block
S&F regulator electronic step type for ceiling fans suitable for AC 230 volts 50 Hz 1200 / 1400mm sweep
MCB DB SPN sheet metal enclosure double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 8 way
S&F MCB SP 240 volts 6-32 Amps
S&F isolator SPN 40 Amps 240 volts
Supply and fix in repair LED Fitting 18 Watts LED MODEL:LHEXBQP71NWO18 MAKE :Havells or Equivalent
S&F in repair LED Security Light fitting of 30 W, Die cast Aluminium extruded housing with reflector and enclosed with toughened glass IP 65 for 1Wx18 Nos LEDs and Driver all as specified & Directed. Make : ENDURAPEARLS25WLED757SASYTOPC of Havells or equivalent inPhilips/ Bajaj/ CG/Luker
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louversn all as specified and directed.
Supply and fix in repair LED Fitting 9 Watts LED including provision of connections cable pvc unsheathed stranded copper conductor and pvc square block of size 80mmX80mm MODEL:LHEXBLP7IN1W009 MAKE :Havells or Equivalent in Philips/Bajaj/HPL
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick burried burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plare No 3,connected to earthing test point all as specified or indicated including testing on completion including excavation and earth work in any strata,PCC Chamber with cover,Charcoal and Salt as required & 15 mm Light Grade GI pipe from steel plate to DB in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge.
Supply,laying,jointing , testing and commisioning XLPE cable 1100 volts grade PVC insulated armoured & PVC sheathed with stranded aluminium conductor heavy duty ISI marked incl cable glands lugs bolts nuts washers etc to suit the cable size to be laid in trenches fixed along pole, LT pannel floor bore or through GI pipe laid under floors, Fixed, concealed in wall encased in GI pipe etc complete of following sizes including taking down old unserviceable over head conductors and insulators channels carefully as directeed by engineer in charge
25 Sqmm x 3.5 Core
10 Sqmm x 2 Core
M & L for HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia 40mm. Make:-Infra/Supreme/Prince
M&L for road cutting and making good with PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) complete all as directed by Enger -in- charge.
M & L of new Gl steel tube Light grade galvanized of size 80 mm dia with all fitting laid in trenches complete and all as specified and directed by Engr in charge. Make : Jindal/ Tata/ Prakash Surya/ Ravindra./Swastik
Supply and Lay pipe galvanised Medium class including fitting complete 25 mm dia
Supply and Lay pipe galvanised Medium class including fitting complete 20 mm dia
Supply and fix gate valve stop screwed 20 mm
M&L for MS Work i:e includes material,cutting,welding,other process for shaping of material to get into required shape as per site requirment and fixing on site. Note: Earthwork will be measured and paid separately
H S TAKHI
Dinesh Constructions
M/S B T DONGARE CONSTRUCTION CO.
AVS CONSTRUCTION
Santhi Enterprises
DR J S CHADHA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .