Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soils.
Removing excavated material to a distance not exc 50mtr and depositing where directed at level n exc1.5 mtr above the starting point.
Taking down old unserviceable GI/PPR tubing connections including disconnection of fittings from tubing Including DI/CI Fitting complete as directed by Engr-in-Charge of following sizes :-
Old GI 20 mm bore
Old GI 25 mm bore
Old GI 40 mm bore
Old GI 50 mm bore
Taking down old unserviceable GI/PPR tubing connection including disconnection of fittings from tubing Including DI/CI/GI Fitting complete as directed by Engr-in-Charge of following sizes :-
Old GI 80 mm dia
Taking down old unserviceable CI/DI tubing connection including disconnection of fittings from tubing Including DI/CI Fitting complete as directed by Engr-in-Charge of following sizes :-
Old DI/CI 200 mm dia
Old DI/CI 80 mm dia
Old DI/CI 100 mm dia
Old CI/DI 150 mm dia
Relaying of old DI/GI/CI tubing and connections with new fittings in with new fitting new or old position including new tightening rubber complete all as directed by Engr-in-Charge.
GI pipe of 80 mm bore
Supply & laying of water pipe lines of the following sizes and Med grade complete with fittings (such as bends, elbows, tees, short pieces, connectors, caps, plugs, unions and screwed socket joints etc) laid in trenches complete as directed by Engr-in-Charge, of following sizes (Note when pipe laid in straight line then the 3rd length is required to be connected by appropriate size of union. :- Note: (i) During laying pipe line cutting existing road/path/culvert/pcc tile and floor will be repair by the contractor without any extra cost and make surface as previous. (ii) After Laying of pipe line routin/running water supply will be check by the contractor.
GI pipe, 20 mm dia
GI pipe, 25 mm dia
GI pipe, 40 mm dia
GI pipe, 50 mm dia
GI pipe, 80 mm dia
Supplying, laying, jointing & testing Ductile iron Pipes ,special class – K 7 ISI marked (IS-8329-2000 Reaffirmed -2005 Eddition 4.1) suitable for push on joints supplied with rubber gaskets , with sockets and cement mortar lining and metallic zinc coating inside and with finishing layer of bitumenous paint outside , without polyethelene sleeves but including Push on joint supplied with EDPM rubber gasket conforming to IS 5382-1985(reaffirmed-2003) with dual hardness of type 2 (bulb) and type-5 (Heel) quality , laid in trenches all as specified and as directed complete of following size:Note: After laying u/m pipe line the contractor should check proper water supply through the Pipe line.Note: (i) During laying pipe line cutting existing road/path/culvert/pcc tile and floor will be repair by the contractor without any extra cost and make surface as previous.
DI pipe of 200 mm bore
DI Pipe 150 mm bore
DI pipe of 100 mm bore
DI pipe of 80 mm bore
S&F in replacement of old damaged / unserviceable gate valve non rising spindle heavy duty with iron wheel head, screwed both end for connection GI pipes complete all as specified for the following sizes of pipe (ISI marked).
GI tubing 50mm dia bore
GI tubing 40mm dia bore
GI tubing 25mm dia bore
GI tubing 20mm dia bore
GI tubing 15mm dia bore
Supply and fix in repalcement of Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe of following size and make compatable connection with existing.
PVC pipes 20mm
PVC pipes 25mm
Supply and fixing in repair of Gi union
15 mm dia
20mm dia
25 mm dia
40mm dia
50 mm dia
Supply and fixing in repair of GI elbow
15 mm dia
20mm dia
25 mm dia
40mm dia
50 mm dia
Supply and fixing in repair of GI Tee
20mm dia
25 mm dia
40mm dia
50 mm dia
Supply and fixing in repair of GI Socket
15 mm dia
20mm dia
25 mm dia
40mm dia
50 mm dia
Supply and fixing in repair of GI Nipple
15 mm dia
20mm dia
25 mm dia
Supply and fixing in repair of MS dead Plug.
20mm dia
25 mm dia
50 mm dia
Supply and fixing in repair of Socket Reducer.
25mmx20mm dia
20 mmx 25mm dia
S&F in repair of Rotational moulded polye thylene water storage tanks of capacity 500 Ltrs with closed top hoisted conforming to IS- 12701(1989) and fixed in position cylindrical vertical type complete with inlet, outlet, overflow, and wash out connection, closed top cover complete including hoisting in position including S&F 25 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) etc all as specified and directed by Engineer-in-Charge.
S&F in repair 20 mm ball valve high pressure of PTMT with epoxy coate brass rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) etc all as specified and directed by Engineer-in-Charge.
S&F in repair 25 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) etc all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of ISI Marked, of approved quality, cast iron non return valve 100 mm bore , PN 1.0 both ends flanged jointed and tested including taking down of old one and arrangement of flanged on existing Pipe making compatable complete all as specified and directed by Engr-in-charge.
M & L for caulking of lead joint of spigot and socket cast iron/Ductile iron pipes and joints incl providing lead wool and making joint leak proof including necessay earth work/excavation and making good disturbed site, T & P and draining out water etc of following complete as directed by Engr-in-Charge (Note :- (i) If any CI/DI special is used, then it will be paid in respective item) (ii) If more than1leakage found in one job like in coller,tee, bend,socket reducer etc will consider as1 each job.(iii) Same leakage found in previous place then contractor will re-done it in Contract laibility period without any extra cost.
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F, for CI/DI special bends (any type radius & angle), tappers any type (straight bend increasing or decreasing or double socket etc) tee pieces single branch ‘Y’ junction double branch cross (all sockets or socket & spigot) collars caps plug etc up to 150 mm bore for spigot & socket and socket pipes complete as directed by Engr-in-Charge
Cutting GI/CI/DI pipes and reducing to required length in position for insertion of tees, branches etc complete as directed by Engr-in-Charge
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F in repalcement of sluice valve cast iron both ends flanged class PN-1.6 conforming to IS-14846 with stainless steel spindle including joints & jointing materials (Rubber gasket, nut, bolts,washers etc) complete as directed by Engr-in-Charge following sizes.
200 mm bore
150 mm bore
100 mm bore
80 mm bore
100 mm bore
80 mm bore
S&F in repalcement of Air Relase valve Ductile iron/stainless steel/plastic pressure rating PN-25 or to match system requirment conforming to IS-14845 including connection (threaded or flanged) as site requirment joints & jointing materials to continuously relases air under pressure during pipeline operationcomplete as directed by Engr-in-Charge.
Material and labour for painting of water supply tubing upto 150 mm after preparation of old painted surface by proper cleaning and then applying two coat of synthetic enamelled paint by spray machine as per existing colour code as directed by Engineer-in-Charge
Material and labour for painting of water supply Centrifugel pump alongwith motor upto 40 HP capacity after prepation of old painted surface by proper cleaning and then applying two coat of synthetic enamelled paint spray machine as per existing colour code or marking MES No on it as directed by Engineer-in-Charge
Pipe fitter and Labour only for attending day to day external water supply compliants of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply, including Holiday and sunday complete all as directed by Engineer - in - Charge. Note: (a) Any material required for complaints shall be measured & paid separately under respectvie item hereinafter) (b) In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Cocern JE is satisfied with contractors view, no recovery will be made. C)All T&P required for attending the Complaints shall be provided by the contractor. (d) Pipe fitter and Labour shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and suitable ladders for reach the roof tank etc ,as required at site.
S&F in replacement of water pressure gauge of Bourden’s type upto 150 mm dia with pressure range of 0 to 10 Kg/Sqcm on rising main water supply line including fixing arrangement , GI tubing nipple stop cock making holes by drilling and welding of socket complete all as specified.
M & L incl dismantlling for construction of brick masonry valve pit of size 100 x100x100 cm (internal dimension)of sub class 'B' brick built in cement mortar ( 1:4 ) on 200 mm thick PCC 1:4:8 type D2 using 40 nn graded aggregate as in foundation including PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in bedding and coping, 15 cm thick cement plastering in cm (1:4) internally and externally upto 15 cm below ground level and providing valve pit cover with 3 mm thick MS sheet welded with 40 X 40 mm X 6 mm angle iron frame fixed on top surface of pit wall on edge of the cover and hinged in one side and providing locking arrangement including complete painting of the corner with two coats of synthetic enamel over one coat of red oxide primer complete all as specified and directed.
M & L incl dismantlling for construction of brick masonry valve pit of size 90x90x90 cm (internal dimension)of sub class 'B' brick built in cement mortar ( 1:4 ) on 200 mm thick PCC 1:4:8 type D2 using 40 nn graded aggregate as in foundation including PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in bedding and coping, 15 cm thick cement plastering in cm (1:4) internally and externally upto 15 cm below ground level and providing valve pit cover with 3 mm thick MS sheet welded with 40 X 40 mm X 6 mm angle iron frame fixed on top surface of pit wall on edge of the cover and hinged in one side and providing locking arrangement including complete painting of the corner with two coats of synthetic enamel over one coat of red oxide primer complete all as specified and directed.
M & L for taking up and down and refixing the same including excavation in any type of soil for cleaning detection of leakage and blockage of GI Pipe any size including breaking of PCC floor/ tiled surface of required area or removing PCC interlocking tiles or any type of flooring complete including returning filling in and removal of surplus mud / soil after taking out leaked water from pit not more than 1.5 m deep and making it dry and making good surface as previous complete all as specified and directed. Note : (i)Upto 12 Rm digging will consider as 1 Each Job (ii)Rate is including earth works and all type of GI fitting like bends, elbows, union, sockets, reducer and short length of GI pipe with suitable flanged if required etc. as per site requirement.
M & L for taking up and down and refixing the same including excavation in any type of soil for cleaning and detection of leakage of CI/DI Pipe any size including breaking of PCC floor/ tiled surface of required area or removing PCC interlocking tiles or any type of flooring complete including returning filling in and removal of surplus mud / soil after taking out leaked water from pit not more than 1.5 m deep and making it dry and making good surface as previous complete all as specified and directed. Note : (i) Upto 5 Rm digging will consider as 1 Each Job (ii) Rate is including earth works.(iii) DI/CI Fitting Shall be measured and paid seperately in respective items.
Disconnecting and taking out existing centrifugal pump set of any capacity, electric driven 3 phase 415 volt including transporting to workshop and Re-fixing in the same position after repair all as directed by Engineer-in-Charge. Note Spare parts shall be measured and paid seperetlyas per relevent items.
M&L, for Rewinding of 3 phase squirrel cage induction motor after disconnecting motor from pump and dismantling the motor, taking down burnt winding wire of field coil and rewinding of field coil for suitable size of super enameled copper winding wire with necessary insulation materials including and necessary connection etc all as specified and directed of the following sizes:-
Supply and fix in repair of following parts for existing centrifugal pump set electric driven 3 phase 415 volt 40/25/15/10/7.5 HP having discharge. Note:(i) arrangement of stand by Centrifugal Pump/Monoblock with Motor as existing pump during the breakdown of any existing Monoblock/ Centrifugal Pump as per site including transportation, installation and taking out existing Centrifugal Pump and lowiring the stand by pump with necessory T&P items as required at site complete all as specified and directed.
Replacement of ball bearing of size as per sample given
Pump motor MS coupling (pump/motor for repair as per ser no 39.00)
Replacement of gland coller set complete
Cover bolts & washers, neck ring
CI impellar suitable for existing 40 HP centrifugal pump set.
CI impellar suitable for existing 30 HP centrifugal pump set.
CI impellar suitable for existing 10 HP centrifugal pump set.
CI Gland packing chaplla
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body upto10 HP
Supply and fix in repair fully automatic star delta starter complete of following capacity with all as directed by engineer-in-charge(A) motor protection circuit.
For 40 HP motor
For 7.5/10 HP motor
Supply only calcium based high strength chlorination chemical for water disinfection in granular form in factory sealed HDPE container (45/50 Kg Each) having chlorine concentration level 70%.
Lifting from borewell and Disconnecting the existing non functional submersible pump set from supply, dismantling existing CI/GI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, alongwith existing column pipe and existing submersible cable of any size from the bore well (approximately 50 mtr depth of pump set from GL) complete all as specified and directed by Engineer-in-Charge. NOTE: - Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost
Dismantling and strip opening of submersible pump & motor of any description and in any position for servicing /overhauling, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective/unserviceable parts with new parts, reassembling the Pump & motor, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities pumps & motors :-(a) 20 to 25 HP, three phase, 415 Volts, 50 Hz, AC supply Note :- Speare parts will paid seperately under relivent items
Supply and replaceing the following U/S items/parts upper & lower rubber housing bush, stainless steel rotor sleeve and thurst bearing complete of AC submersible motor of any description & any capacity, all as specified and directed by the Engineer-in-Charge
Machining, grinding balancing and reconditioning work for the Rotor, stator item & capacities of the submersible motors of any description, complete all as specified and directed by the Engineer-in-Charge.
Supply and replaceing the following U/S items/parts Gun metal bush, neck ring, impleller, spacer and pump key for multistage submersible pump of any description, 7.5 to 25 HP capacity, all as specified and directed by the Engineer-in-Charge
Taking out & removing old burnt out windings of the submersible electric motors of following capacity and rewinding of submersible electric motors with existing size PVC insulated, copper conductor as approved by the engineer-in-charge including cleaning the slots with carbon- tetra-chloride solution before rewinding ,transportation to site, fixing etc complete all as specified and directed by Engineer-in-Charge:-(a) 10 to 25 HP, three phase, 415 Volts, 50 Hz, AC supply
Lowering down in borewell of the submersible pump set after repair of any description and any capacity & in any position, in bore well alongwith column pipe and submersible cable of any size (approximately 50mtr depth of pump set from GL) complete all as specified and directed by Engineer-in-Charge including making necessary electric connections & testing the pump set after lowering. NOTE:- Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost.
S&F in repair 6 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, 1100 Volt grade, complete all as specified and directed by Engineer-in-Charge.
Taking Down of FPC type Solar water heating system,complete with heat exchanger of any capacity ,with electrical heating back up,complete all as specified and directed. Note: During Taking down any type of damages repair will be done by the contractor without any extra cost.
Supply and Installation in replacement of solar hot water tank of capacity upto 500 Ltrs made of 1 mm SS304Fins of Solar water heating system ,Flat plate collector type ,with heat exchanger of upto 500 litre per day capacity ,with electrical heating back up,complete all as specified and directed.
M&L for solar water heater of existing capacity including checking serviceability of FPC and ETC panel choking cleaning and adding heat transfer, chemical( glycol) suitable grade with top up of suitable capacity ,replacement of defective items such evacuted tube, flat plate, nuts, washer, gasket, end bracket, insulation, reflectro of any size, complete all as specified and directed. Note: Flate plate collector and Evacuted tube collector measured and paid seprately.
Supply and laying in replacement of fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC or tape and overall PVC sheathed 2x6 sq. mm nominal cross section in service connections,complete all as specified and directed.
Supply and Laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage upto 11kv for Centrifugal electrical pump purpose aas per IS 15652-2006 (Superseding IS 5424) suitable for electric shock safety 2mx1m complete all as specified and directed.
Supply of drinking of water through tanker /bouser for domestic use including transportation from source to U/G sump / MD Accn / OTM as per site required in Sector 'A' (Fathegunj Area) under GE (Army) Baroda. The water should have th following main factors :- (a) Water should be clear and from all suspended matters both Hyganic & inorganic matter. (b) Water should be free from taste and odour. (c) Water should be colour less and no vegetable stain should be present. (d) water should be soft that it should not contain dissolved impurties like calcium or magnesium bacarbonate and Sulphates. (e) Water shoud be soft and shuold be free from all pathogenic organism causing diseases. (f) Copy of gate entry at guard room with vehicle No date and time shall be submitted duly defaced by Engr-in-Charge in charge before claiming payment . (g) Water will be supplied within triple story through motor with pipe is responsiblity of the contractor. Note :- Portable Water will be supplied by supplier.
M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris all as directed by the Engineer-in-Charge.
Material and labour for bacteriological and chemical analysis of water sample at govt approved lab (Iso 9001:2008) including collecting sample from different pumphouse using labed owned sample jar all directed and specfied by Enginner-in-charge. Note: (i) Water sample report shall be submitted to Concern Engr-in-Charge.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of upto 450 mm dia suitable for 0.4 mpa working pressure.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tenderpages8972.pdf
Tender Documents • 0.47 MB
BOQ_867504.xls
BOQ • 11.03 MB
Download all tender documents and submit your bid