Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC AT SAYAL SAYAL DISTT RAMGARH JH | NA | NA | 825101 | L1 | Accepted-AOC WITHOUT GST | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
Refer Docs
EMD Value
₹36,200
Closing Date
5 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PE(ENM) BIRSA PROJECT
OFFICE OF PE(ENM) BIRSA PROJECT
ERECTION AND DISMANTLING OF 3.3 KV OVER-HEAD LINE FOR SUPPLYING POWER TO HEMM,PUMPS AND TRANSFORMERS ON AS AND WHEN REQUIRED BASIS FOR THE PERIOD OF ONE YEAR IN BIRSA PROJECT
2023_CCL_277719_1
PE(EnM)/BIRSA/e Tender/23-24/06 Dated 23.04.2023
Open Tender
Electrical and Maintenance Works
Item Wise
365 days
BIRSA PROJECT BARKASAYAL AREA
Please refer Tender documents.
2 documents required · 2 mandatory
₹36,200
OFFICE OF PE(ENM) BIRSA PROJECT
5 Oct 2024
24 Apr 2023
6 May 2023
24 Apr 2023
5 May 2023
24 Apr 2023
25 Apr 2023
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 10.00 metre and upto 12.00 metre
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required (3 KM X 03 WIRE X 342 KG/KM = 3078 KG)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
ERECTION OF CROSS BRACING SET
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Erection of disc/ pin insulator for 11 KV over head lines as required
Erection of G.I. Wire No. 8 SWG including binding etc. as required (3 KM X 192 KG/KM = 576 KG)
SUPPLY OF 6/8 SWG GI WIRE FOR CONTINUOUS EARTHING AND CRADLING 3 KM FOR CRADLING = 576 KG 1.96 KM FOR CRADLING = 376.32 KG TOTAL = 952.32 KG
Erection of cradle guard as required 10 SPAN X 48 NO/SPAN = 480 Nos
SUPPLY AND ERECTION OF MS ANGLE RON 50 mm X 50 mm X 06 mm(4.71 kg/mtr) CROSS ARM FOR CRADLING
CONNECTING/DISCONNECTING 3.3 KV 3 PHASE POWER CABLE FROM OH LINE AS REQUIRED
CONNECTING/DISCONNECTING 3.3 KV 3 PHASE POWER CABLE FROM OH LINE AS REQUIRED
DISMANTLING/INSTALLATION OF GANG OPERATING ISOLATOR 400 AMP FOR 3.3 KV OH LINES AS REQUIRED
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
SUPPLY OF 16 mm X 125 mm bolts and nuts with washers
LOADING,TRANSPORTING AND UNLOADING OF POLES (TRUCK WILL BE PROVIDED BY CCL)
LOADING,TRANSPORTING AND UNLOADING OF DISMANTLED OH ACCESSORIES (TRUCK WILL BE PROVIDED BY CCL)
Total impact of GST for the purpose of CTC
M/S KUMAR GAURAV
techsummary_287487.pdf
PDF • 0.04 MB
finsummary_287487.pdf
PDF • 0.04 MB
boqcomparativechart.pdf
PDF • 0.06 MB
finance_287487.pdf
PDF • 0.03 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .