Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71,548Accepted-AOC | L1 | Accepted-AOC L1 ACCEPTED | |
| 2 | Rejected-Technical KADAVATH PUVANITHI VEEDU B P ANGADI TIRUR 676102 | TIRUR | MALAPPURAM | KERALA | 676102 | - | Rejected-Technical L1 accepted |
Tender Value
₹78,980
EMD Value
₹1,975
Closing Date
24 Dec 2024, 5:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer, LID EW Section, Tirur Municipality
Retender - Annual Plan-Electrification and Providing Starters for Kunnummal Drinking Water Supply Scheme
2024_LSGD_716810_4
04/Etender/2024-25/Percentage
Open Tender
Electrical Works
Percentage
150 days
Tirur Minicipality
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹1,975
Yes
15 Mar 2025
17 Dec 2024
27 Dec 2024
17 Dec 2024
24 Dec 2024
17 Dec 2024
Amount
Electrical
OD91546/2024-2025:Supply, Installation, Testing and Commissioning of DOL Starter Panel for 10HP Submersible motor comprising of Relay, LED Indicator, Voltmeter, Ammeter, Contactor, Capacitor etc as required. MUG-15, L&T make
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD91630/2024-2025:Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TPN MCB complete with connections, testing and commissioning etc. as required.
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
OD91554/2024-2025:Supply and installation of dust and vermin proof Three-phase sintex motherboard (GS MB?6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required
OD91555/2024-2025:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
OD91556/2024-2025:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
OD91561/2024-2025:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system
OD91562/2024-2025:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD91634/2024-2025:Supply and fixing of 20W LED Bulb, as required
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
OD91563/2024-2025:Charges for preparation of KSEB or KSELB test Report, drawings and other related documents etc as required by the contractor as per the instruction from the Assistant Engineer and submit it to the concerned KSEB section office or KSELB including application fee. Copy of application fee and related documents are to be submitted to the concerned Assistant Engineer.
KP ABDUL RASHEED (BID ID -2033464)
Bidder Name
KP ABDUL RASHEED
MUNEER M
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1131375.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .