Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC CHAKKALAKKAL H KOTTAT P O | L1 | Accepted-AOC FIRST LOWEST QUOTED BIDDER BELOW ER | |
| 2 | L2₹15.0 L+₹18,355.12 (1.24%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST QUOTED BIDDER BELOW ER | |
| 3 | L3₹15.3 L+₹51,430.67 (3.47%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST QUOTED BIDDER BELOW ER | |
| 4 | L4₹15.8 L+₹97,916.80 (6.60%)Rejected-AOC VELLAPLACKAL HOUSE VARANDARAPPILLY PO THRISSUR 680303 | THRISSUR | THRISSUR | KERALA | 680303 | L4 | Rejected-AOC FOURTH LOWEST QUOTED BIDDER BELOW ER |
| Sl No | Description | Qty | Unit | KOLAR MILL STORES L2 | BIJU JOSE L1 | BINSON JOSEPH L4 | AYKO TOOLS L3 |
|---|---|---|---|---|---|---|---|
| 1.00Electrical work | |||||||
| 1.00 | OD130385/2025-2026: Supply , conveyance and unloading of 45 KVA 415 V Three phase DG set with company made acoustic canopy conforming to CPCB4 norms as per technical details given below.
.
Diesel Generator set make Preferred- Cummins / caterpiller/ Ashok Leyland(OJUS BRAND)
Type of Engine - Diesel Engine
No. of Cylinders -In -line 4 suitable to develop the 56.5 BHP as per manufactures standards.
Liquid Cooled., - Turbo charged / natural
Design - suitable for generating set application
Standard accessories with Diesel Engine ,SELF Start,
Close coupling Weght: 1100kg,
Fuel Tank capacity -140Ltr.
Fuel pump
Mechanical governor
Lubricating oil ,
Residential type Exhaust silencer
Engine Instrument Panel
Starting switch with key or button
Lubricating oil pressure gauge
Water temperature gauge
RPM indicator with hour meter
Supply Control for engine
Battery control (trip) Trip for low lubricating oil pressure
Battery control (trip) Trip for high water temperature
providing necessary warning system and other safeties as contemplated in relevant ISS
Fuel pipes
Oil resistant hoses of 20 mm dia or nearest MS pipe as per manufactures requirement for fuel lines
Alternator Make Leroy -Somer or Eqivalent
Make - Leyroy somer.
Type self excited and self regulated
Capacity 45KVA / 32 KW @ 0.8 P.F lag
System Voltage Three phase 415 V AC 50 Hz
Speed 1500 RPM
Voltage regulation band 2.5% of rated voltage
Insulation class F/H
Alternator should confirm IS4722
The DG set should mount on a suitable size base frame with anti vibration mounting pad.
fuel tank integrated with acoustic enclosure complete with fuel provision for filling the diesel electric fuel gauge.
Battery
Required number of suitable rated fully charged battery with leads and terminals as required as per manufactures requirements.
Operation manual service manual list of spares etc. shall be submitted while the DG set is supplied.
Standard control panel integral with the acoustic enclosure comprising the following
125 A 25 KA 4 pole MCCB having adjustable setting having connection with statutory protective system like EFR and neutral CT etc.
Digital type meter with accuracy class 0.5 to read parameters such as KWH, wattage, current, frequency etc.
LED type phase indication type
Fuse protection shall be provided for the meters and indication lamps.
Cost of DG set with charges of conveyance and unloading at site. | 1 | set | 7,56,631 ₹7,56,631 Lowest | 7,60,000 ₹7,60,000 | 8,30,000 ₹8,30,000 | 7,88,000 ₹7,88,000 |
| 1.00 | 14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia | 6 | metre | 978 ₹5,868 | 978 ₹5,868 | 750 ₹4,500 Lowest | 990 ₹5,940 |
| 1.00 | OD130363/2025-2026:Installation, testing and commissioning of 45 KVA DG set on the newly constructed concrete basement after initial filling of oil and fuel, trial run etc. | 1 | set | 5,691.35 ₹5,691.35 Lowest | 5,700 ₹5,700 | 35,000 ₹35,000 | 5,700 ₹5,700 |
| 1.00 | OD130373/2025-2026:Supply and clamping 80 mm dia medium class GI pipe with clamps made from 25x3mm MS flat (for extension of exhaust pipe) on wall with required accessories including cutting and making good the wall painting the exposed portion etc. as required. | 6 | metre | 1,256.35 ₹7,538.1 | 1,256 ₹7,536 | 1,200 ₹7,200 Lowest | 1,300 ₹7,800 |
| 1.00 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 5 | set | 8,601.1 ₹43,005.5 | 8,600 ₹43,000 | 7,300 ₹36,500 Lowest | 8,700 ₹43,500 |
| 1.01 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 38 | metre | 165.25 ₹6,279.5 | 101 ₹3,838 Lowest | 220 ₹8,360 | 175 ₹6,650 |
| 1.01 | 6.12:Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. | 5 | each | 139 ₹695 Lowest | 139 ₹695 Lowest | 200 ₹1,000 | 139 ₹695 Lowest |
| 1.01 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. | 0.8 | metre | 1,337.15 ₹1,069.72 | 1,337 ₹1,069.6 Lowest | 2,000 ₹1,600 | 1,337.15 ₹1,069.72 |
| 1.01 | 90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) | 32 | metre | 181.3 ₹5,801.6 Lowest | 185 ₹5,920 | 300 ₹9,600 | 181.3 ₹5,801.6 Lowest |
Tender Value
₹15.0 L
EMD Value
₹37,523
Closing Date
13 Aug 2025, 6:00 pmClosed
ASSISTANT ENGINEER
O/o The Asst. Exe. Engineer, LID and EW Subdivision, Chalakudy BP P. O. Chalakudy
Electrical works
2025_LSGD_782827_1
07/AE/LID EW/CKDY/2025
Open Tender
Electrical Works
Item Rate
180 days
KODASSERY GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹37,523
Yes
25 Oct 2025
5 Aug 2025
16 Aug 2025
5 Aug 2025
13 Aug 2025
5 Aug 2025
Amount
Electrical work
OD130385/2025-2026: Supply , conveyance and unloading of 45 KVA 415 V Three phase DG set with company made acoustic canopy conforming to CPCB4 norms as per technical details given below. . Diesel Generator set make Preferred- Cummins / caterpiller/ Ashok Leyland(OJUS BRAND) Type of Engine - Diesel Engine No. of Cylinders -In -line 4 suitable to develop the 56.5 BHP as per manufactures standards. Liquid Cooled., - Turbo charged / natural Design - suitable for generating set application Standard accessories with Diesel Engine ,SELF Start, Close coupling Weght: 1100kg, Fuel Tank capacity -140Ltr. Fuel pump Mechanical governor Lubricating oil , Residential type Exhaust silencer Engine Instrument Panel Starting switch with key or button Lubricating oil pressure gauge Water temperature gauge RPM indicator with hour meter Supply Control for engine Battery control (trip) Trip for low lubricating oil pressure Battery control (trip) Trip for high water temperature providing necessary warning system and other safeties as contemplated in relevant ISS Fuel pipes Oil resistant hoses of 20 mm dia or nearest MS pipe as per manufactures requirement for fuel lines Alternator Make Leroy -Somer or Eqivalent Make - Leyroy somer. Type self excited and self regulated Capacity 45KVA / 32 KW @ 0.8 P.F lag System Voltage Three phase 415 V AC 50 Hz Speed 1500 RPM Voltage regulation band 2.5% of rated voltage Insulation class F/H Alternator should confirm IS4722 The DG set should mount on a suitable size base frame with anti vibration mounting pad. fuel tank integrated with acoustic enclosure complete with fuel provision for filling the diesel electric fuel gauge. Battery Required number of suitable rated fully charged battery with leads and terminals as required as per manufactures requirements. Operation manual service manual list of spares etc. shall be submitted while the DG set is supplied. Standard control panel integral with the acoustic enclosure comprising the following 125 A 25 KA 4 pole MCCB having adjustable setting having connection with statutory protective system like EFR and neutral CT etc. Digital type meter with accuracy class 0.5 to read parameters such as KWH, wattage, current, frequency etc. LED type phase indication type Fuse protection shall be provided for the meters and indication lamps. Cost of DG set with charges of conveyance and unloading at site.
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
OD130363/2025-2026:Installation, testing and commissioning of 45 KVA DG set on the newly constructed concrete basement after initial filling of oil and fuel, trial run etc.
OD130373/2025-2026:Supply and clamping 80 mm dia medium class GI pipe with clamps made from 25x3mm MS flat (for extension of exhaust pipe) on wall with required accessories including cutting and making good the wall painting the exposed portion etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
6.12:Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.6:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD130361/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x3mm brass nut and bolt .
OD130365/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt .
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.11.1:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 100A with CBCT.
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
90.14.11.14:MCCB AccessoriesSupply and fixing rotary handle, Direct type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
OD136207/2025-2026:Supply and fixing the following accessories in the existing panel board and giving connections etc(63A,10KA,frame S, Thermal magnetic release, adjustable over load release 80- 100% , MCCB, ref CSESK125FMU4P-A),
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.12.5.28:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
90.12.7.27:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
OD130364/2025-2026:Supply and installation of 63 A, 415V, 50Hz AC 23A 4 pole on load changeover switch in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement on existing angle iron frame work or directly to wall using necessary bolts and nuts, fixing the unit to wall making good the damages colour washing etc. including giving necessary connections as required.
OD165961/2025-2026:Additional electric work and panel board for Automation by procuring and fixing ATS.
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.20:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
OD130384/2025-2026:Supply and fixing up to 20A, 230/415 V, Bakelite fuse unit with fuse link.
OD130366/2025-2026:Supply and providing 2.00 mm thick 3.3 KV synthetic elastromeric fire retardant insulating sheet.
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD130372/2025-2026:Supply and installation of ABC Powder Type (Stored Pressure) Fire Extinguisher 4Kg. Capacity ISI Mark IS: 15683 consisting of M.S cylindrical body, squeeze leve,r discharge valve fitted with pressure indicating gauge, 30cm long, high pressure discharge hose, nozzle etc. with MAP Powder for 'A','B' & 'C' class fire, fixing on wall with wallhook etc as required.
OD130369/2025-2026:Painting letters or figures of the sizes 2.5 cm, 4 cm, 5cm height with enamel paint as identification mark to SB, DB, Panel board etc. as required
OD130359/2025-2026:S$F LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange colour
OD130367/2025-2026:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable and other dimensions noted along with each size of glands for the 25 sqmm with 12mm wide x 1 mm thick clip of cable as required.
90.16.3.3:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm GI strip
OD130374/2025-2026:Supply and providing GS-MB 3750 (inside 350X481X210 mm) meter box for fixing KSEB meter with hinged door and vision panel etc, fixed on wall and giving connections as required. (Sintex or equivalent make)
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
OD130382/2025-2026:Supply and providing 12 W, LED, out door bulk head fittings on wall/ceiling and giving connections with required length of 16/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire etc as required. ( LUKER eco LBKOVSL12 or equivalent make)
OD130370/2025-2026:Supply and providing multifunction meter to read V, A, f 3 phase accuracy class one.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD130371/2025-2026:Supply and fixing 63 A HRC fuse base with HRC fuse link in the existing meter board and giving connections etc.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
OD130381/2025-2026:Supply and providing 9L capacityGI fire bucket in post office RED with primer coat of red oxide and written with white paint FIRE mounted on MS angle frame work /wall bracket filled with fine sand painted the bracket/ floor stand including making good the damages colour washing etc. as required as per IS2546.
OD130380/2025-2026:Supply and providing LED phase indication lamps RYB in colour.
OD130383/2025-2026:Supply and laying bare earthing conductors of 3.15 mm copper conductor (10 SWG) laid 0.6 mtr below ground level including excavating trench of suitable size and refilling etc. as required ( in ordinary soil).
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD130378/2025-2026:Supply , installation of 200mm sweep light duty exhaust fan in plastic body with self opening lowers working on 230 V single phase AC in the existing opening, fixing necessary anchor bolts/ bolt and nuts etc. as required including giving connections with the supplied wire along with the exhaust fan.
OD130368/2025-2026:Charges for preparation of connected drawings for obtaining approval from electrical inspectorate.
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
OD130375/2025-2026:Provision for remitting statutory charges at Ele, Inspectorate.(On production of original Recei,is permitted. )
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
OD152022/2025-2026:Supply and providing 1200mm efficiencia DX BLDC Ceiling fan , 5star rated double ball bearing (w/o remote) preferred Havells or equivaient reputed make.
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD152020/2025-2026:Supply, Conveyance, Installing testing and commissioning 20W Flood light with Die cast aluminium housing
OD152021/2025-2026:Supply, Conveyance, Installing testing and commissioning 70W Flood light with Die cast aluminium housing and toughened glass > 110Lm/W ; potted driver, IP66; THD < 10% PF >0.95 , TFS- 504 - 70 - 57.
90.15.3.4:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters
OD152027/2025-2026:Dismantling the Defective DB and accessories From position and handed over to authorities
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD152028/2025-2026:Supply, and providing 0.5A to 2 A SP MCB and giving connection as required .
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD157097/2025-2026:Supply and providing tor steel for reinforced cement concrete including cutting bending and tying in shape as required.
OD130377/2025-2026:Charge for preparing test certificate and completion certificate for KSEB connection.
KOLAR MILL STORES (BID ID -2280505)
AYKO TOOLS (BID ID -2281772)
BINSON JOSEPH (BID ID -2286801)
Bidder Name
BIJU JOSE
BINSON JOSEPH
KOLAR MILL STORES
AYKO TOOLS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1284630.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .