Loading…
Loading…
Tender Value
₹10.7 L
EMD Value
₹10,800
Closing Date
5 Oct 2026, 6:00 pm
Superintending Engineer [Electrical]
Providing & Erecting Water Cooler & R.O. Plant At Medical Girls Hostel (G+10) in GMERS Campus Dharpur Ta.& Dist :- Patan
348973
87/01 of 2026 2027
Open
Electrical
Works
Gandhinagar
9 documents required · 9 mandatory
₹900
PIU-General Fund A/c 11-114
₹10,800
25 Sept 2026
25 Sept 2026
25 Sept 2026
5 Oct 2026
25 Sept 2026
Name of Work :-
Ta.& Dist :- Patan.
Quantity Item Description Unit In Amount
No. 2026-27 In words
Replacing Old & Burnout by Providing following type of Modular
Type Accessories mounted with PVC / metallic/Wooden box,
single mounting base frame covered with textured / metallic/white Rupees One hundred
1 1-2-6. 11.00 front plate , modules erected with necessary connections as per Ea. 151.50 Fifty One Paise Fifty
site situation directed by Engineer In charge. Only
(1)One No. SP 6 Amp. Cat.III
Replacing Old & Burnout by Providing following type of Modular
Type Accessories mounted with PVC / metallic/Wooden box,
single mounting base frame covered with textured / metallic/white Rupees One hundred
2 1-2-6. 11.00 front plate , modules erected with necessary connections as per Ea. 151.50 Fifty One Paise Fifty
site situation directed by Engineer In charge. Only
(2) One No 5 pin plug Cat.III
Replacing Old & Burnout by Providing following type of Modular
Type Accessories mounted with PVC / metallic/Wooden box,
single mounting base frame covered with textured / metallic/white Rupees One hundred
3 1-2-6. 11.00 front plate , modules erected with necessary connections as per Ea. 180.79 Eighty Paise Seventy
site situation directed by Engineer In charge. Nine Only
(9) 16 Amp. SP one way switch Cat.III
Replacing Old & Burnout by Providing following type of Modular
Type Accessories mounted with PVC / metallic/Wooden box,
single mounting base frame covered with textured / metallic/white Rupees One hundred
4 1-2-6. 11.00 front plate , modules erected with necessary connections as per Ea. 199.98 Ninety Nine Paise Ninety
site situation directed by Engineer In charge. Eight Only
(10) 6/16Amp. Universal socket Cat.III
Providing and erecting ISI mark Medium class RIGID PVC PIPES
of following size complete to be erected on/in wall or ceiling
erected with necessary PVC fittings & Junction boxes fixed with Rupees Twenty Four
adhesive solution & Clamps with following dia of pipes, in Paise Twenty Four Only
approved manner as directed
Replacing Old & Burnout by Providing and erecting Mains with
1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed
Rupees Fifty Eight Paise
6 1-4-1. 390.00 in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor Mtr 58.58
Fifty Eight Only
FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (E) in existing pipe (a) 2 wire 1.5 sq.
Replacing Old & Burnout by Providing and erecting Mains with
1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed Rupees Seventy Eight
7 1-4-1. 420.00 in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor Mtr 78.78 Paise Seventy Eight
FRLS PVC insulated stranded wire of green colour for earth Only
continuity of following size (E) in existing pipe (b) 2 wire 2.5 sq.
Replacing Old With Shifted to another Place by Providing &
erecting water cooler having storage capacity 150 Ltr. & cooling
capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet
Rupees Sixty One
temp. of the water should drop by 15˚C within a hour, The water
Thousand Four hundred
8 8-13-2. 11.00 cooler should be comprising of hermetically sealed compressor, Ea. 61482.74
Eighty Two Paise
fan motor, condensing unit, water tank surrounded by
Seventy Four Only
evaporating, coil, thermostats, relay etc.complete with necessary
inlet & outlet connection. The body of water cooler will be made
from Stainless Steel.
Replacing Old With Shifted to another Place by Supplying &
erecting 5 stage single reverse osmosis water purification system
with M.S. powder coated frame, prefilter housing with 'O' ring
Rupees Twenty Nine
presediment filter GAC filter, carbon filter suitable buster DC
Thousand One hundred
9 8-13-6 11.00 pump capacity 80 psi, mention with 40 psi inline type post carbon Ea. 29187.99
Eighty Seven Paise
filter auto low & high pressure switches with following size of
Ninety Nine Only
storage tank & LPH capacity & erected as directed
[C] 50 Ltr / Hr with 150 psi 2 nos booster pump
Say Total Rs. (A)
In Words:- Rupees Ten Lakh Seventy thousand Seven hundred Seventy Two Only
Credit Value : Less value for Dismantling Electrification etc..Rs. 1,977/- (This item shall not quote less value than credit value in
tender i.e. Rs. 1,977/- (Upset value ob the salvaged items of Rs. 1,977/- the credit value to be quoted shall not be less than upset
value mentioned above the quoted amount shall be deducted from the contractor's first RA Bill) as per Dismantling.
Deputy Executive Engineer(Elect.) Executive Engineer(Elect.)
PIU, Patan PIU, Zone-3
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
0.SBD Book_ WC and RO.pdf
Dismantal.pdf
Make List Electrical -WC and RO.pdf
PQ CRITERIA (1).pdf
SCH-B.pdf
Tender Notice no-87.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .