| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.1 LQualified Make: EXIDE
Model: EXIDE SMF EP-100AH,12V , WITH BUY BACK SCRAP OLD BATTERY R 9 263 RAJ NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | Make: EXIDE
Model: EXIDE SMF EP-100AH,12V , WITH BUY BACK SCRAP OLD BATTERY | L1 | Qualified | |
| 2 | L2₹2.2 L+₹3,870 (1.82%)Qualified Make: AMARON QUANTA
Model: Amara Raja 12AL100 CIDCO NASHIK MAHARASHTRA 422009 INDIA | NASHIK | MAHARASHTRA | 422009 | Make: AMARON QUANTA
Model: Amara Raja 12AL100 | L2 | Qualified | |
| 3 | L3₹2.3 L+₹16,170 (7.59%)Qualified Make: AMARON
Model: AMARON QUANTA | Make: AMARON
Model: AMARON QUANTA | L3 | Qualified | |
| 4 | Disqualified Make: EXIDE
Model: EXIDE SMF 12V-100AH BATTERY 118 WARD 5 NASEEB VIHAR COLONY 118 NASEEB VIHAR GHARAUNDA KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | Make: EXIDE
Model: EXIDE SMF 12V-100AH BATTERY | - | Disqualified | |
| 5 | Disqualified Make: Okaya
Model: Okaya 100Ah SMF Lead Acid Battery MAIN BUS STAND NEAR SYNDICATE BANK DHAULANA GHAZIABAD UTTAR PRADESH 245301 | HAPUR | UTTAR PRADESH | 245301 | Make: Okaya
Model: Okaya 100Ah SMF Lead Acid Battery | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
6 Jul 2018, 10:00 amClosed
lead acid battery Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 5 Year (s) Lead Acid Battery ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 100 100 Warranty (Years) 2 Years 2 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 992 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab BANGALURU - Name of the Lab CENTRAL POWER RESEARCH INSTITUTE - Test Report No. 372EATDBT14S0047 - Test Report Date 21/10/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajneesh Singh 176052
GS IS BRANCH Headquarters 9 Corps YOL Cantt 30 30 EMD Required No ePBG Required No
237633
GEM/2018/B/33804
lead acid battery
30 days
Himachal Pradesh; Kangra
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 5 Year (s) Lead Acid Battery ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 100 100 Warranty (Years) 2 Years 2 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 992 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab BANGALURU - Name of the Lab CENTRAL POWER RESEARCH INSTITUTE - Test Report No. 372EATDBT14S0047 - Test Report Date 21/10/2014 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajneesh Singh 176052 | - | - | - |
| GS IS BRANCH Headquarters 9 Corps YOL Cantt 30 30 EMD Required No ePBG Required No | - | - | - |
Exempted
6 Jul 2018
21 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_237633.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .