Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹9.0 Laccepted-aoc | accepted-aoc |
Tender Value
₹14.3 L
EMD Value
₹14,250
Closing Date
24 Feb 2026, 10:30 amClosed
EXECUTIVE OFFICER
OFFICE OF THE EO SVVSSD ANNAVARAM KAKINADA DSIT
Water leakage Treament and Minor Repair works at Hari hara sadan Satyagiri Uphill
897333
WATER LEAKAGE HARIHARASADAN
OPEN - NCB
Civil Engineering Works
KAKINADA, ANDHRA PRADESH
9 documents required · 9 mandatory
₹505
₹14,250
11 Mar 2026
9 Feb 2026
9 Feb 2026
Supply& Application for Epoxy for Ceramic floor tiles joints i.e, application process 1. Drilling of holes with power drilling machine to required depth 12mm to 14mm dia holes . 2.Fixing of Rubber nozzles with Render plug settings 3. Grooving of holes with 140 Pieger grout pump with cement and SBR , Conplast , SBEX -100 , Mixing after completion of grouting . 4.And then after ONE hour tiles joint cutting and water wash for 4mm grooving . 5. after 3Hrs applying epoxy for total grooves . 6. Finally cleaning total surface tiles floor area with using sponge finishing and chemical contents use NITOBOND SBR , CONPLAST , CEBEX-100 ,Render plug , MYK LATICRETE SP-100 epoxy . Finished item of work
Supply& Application for Epoxy for Bathrooms i.e, application process 1. Firstly cleaning all the area . 2. dry the area for 2 hours . 3.after ONE hour Corner joint cutting and water wash for 4mm grooving . 4. after 3Hrs applying epoxy for total grooves . 5. Finally cleaning total surface area with using sponge finishing and chemical contents use MYK LATICRETE SP-100 epoxy . Finished item of work
SPECIALISED POLYSULPHIDE / POLYURETHANE / HIGHBRED ACRYLIC /SEALANT TREATMENT TO THE OLD / EXISTING EXPANSION JOINT IN THE TERRACE, COLUMN, BEAM 1. Cut and remove the existing expansion joint in the screed for a minimum width of 200 mm and a depth of screed ( up to the mother slab) by using diamond disc cutting machine and dispose the debris as per the department instruction. All elevated kerb wall both sides of the expansion joint along with the top free laying slab, cover etc as per the site conditions under the scope of the main contractor / client.2. Remove the existing filling for a minimum depth of 40 mm using sharp knife (approximate size 25 x 40 mm) as per the site condition.3. If the site condition allows to insert backer rod, remove the existing filling for a minimum depth of 70 mm from the top ( the clear filling of sealant should be 40 mm) and insert inside the joint. 4. Clean the surface with air blower up to receive a dust free surface and make sure the surface is sound dry or the moisture content is less than 5 %. 5. Apply one coat of PenetrativePrimer and allow touching dry. 6. Fill the joint by using a sealant gun / notch trowel as per site condition up to the required depth and width and allow to dry for a minimum period of 1 day as per the climatic condition.7. Apply two coat of penetrative sealer coat site mixed primer - mix with portable water and OP Cement in the ratio of 2:1:3 cement by using slow speed mixer machine with paddle for a period of 2 to 3 minutes up to receive a homogeneous mix) @ 1.000 Liter per SQM in the entire screed removed portion ( vertical and horizontal faces) of 200 mm along with saturated ( saturated with MixPRIME AC100: Water: OP Cement in the ratio of 2:1:1) in between the two coats and allow to cure for a period of 6 hours. 8. Do the necessary levelling plastering with cement sand mortar 1:2:4 (6 mm aggregate) screed along with the addition of MixBOND SBR Super and PLAST FIBER 3S as per the following for a minimum thickness of removal.a. Mix the MixBOND SBR Super @ 2 Liter / Bag Cement in the ratio of 1:4 Mortar ( Pre mix the admixture in the portable water for preparing the mortar)b Add 100 Gram PLASTFIBRE 3S in the above liquid and stirred well with a slow speed drill with paddle.c. Prepare the cement sand screed in the ratio of 1:2:4 with above prepared liquid for the suitable consistency.d. Necessary curing and drying for a minimum period of 4 days. 9. In wet condition, provide a dummy expansion joint on the top of the screed for a minimum size of 10 x 10 mm by using sharp trowel10. Apply one coat of Penetrative in the entire surface of the dummy joint and allow to touch dry for a period of 30 minutes. Fill the in the joint by using a sealant gun / notch trowel as per site condition up to the required depth and width
Cost & Supply 110 mm dia 3 M Single Socket PVC/SWR pipe - 6 Kg/sq.cm BMW-G.35
Cost & Supply 75 mm dia 3 M Single Socket PVC/SWR pipe - 6 Kg/sq.cm BMW-G.33
Cost & Supply 90 mm dia 3 M single Socket PVC/SWR pipe - 6 Kg/sq.cm BMW-G.34
Supply & Fixing 75 mm dia - Door Bend 87.5 Degree - UPVC/SWR Pipe fittingBMW-G.58
Supply & Fixing 90 mm dia - Door Bend 87.5 Degree - UPVC/SWR Pipe fittingsBMW-G.59
Supply & Fixing 110 mm dia - Door Bend 87.5 Degree - UPVC/SWR Pipe fittingBMW-G.60
Supply & Fixing 75 mm dia - Single Tee with Door - UPVC/SWR Pipe fittingBMW-G.70
Supply & Fixing 110 mm dia - Single Tee with Door - UPVC/SWR Pipe fittingsBMW-G.72
Supply & Fixing 90 x 75 mm dia - Reducer - UPVC/SWR Pipe fittings BMW-G.94
Supply &Fixing 75 mm dia - Pipe Clip - UPVC/SWR Pipe fittingsBMW- G.104
Supply &fixing 90 mm dia - Pipe Clip - UPVC/SWR Pipe fittingsBMW- G.105
Supply & Fixing 110 mm - Pipe Clip - UPVC/SWR Pipe fittings BMW- G.106
Supply & Fixing 75 mm dia - Coupler - UPVC/SWR Pipe fittingsBMW-G.91
Supply & Fixing 90 mm dia - Coupler - UPVC/SWR Pipe fittingsBMW-G.92
Supply & Fixing 110 mm dia - Coupler - UPVC/SWR Pipe fittingsBMW-G.93
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice
Providing and fixing 28 -30 MM thick solid Wood Polymer Composite(WPC) single extruded door shutter with 3MM top and bottom rigid layer with an overall density of 750kg/Cum. It will be fixed to the frame using 3 inch /4 inch hinges. A minimum of 4 hinges will be required for fixing the door with the frame. BMT-N.92, MAT-05443
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
1 Boq - Water Leakage treatment Hari hara sadan.xlsx
TENDER_DOCUMENT • 0.02 MB
Bid Emptry.doc
TENDER_DOCUMENT • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .