GEMC-511687731593328
Awarded to ELECTROTEK ENGINEERS PRIVATE LIMITED
₹13.5 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Dismantling and removal of existing 500KVA, 22kVor430V Transformer | - | HSN not specified by seller | 1 Each | 31,270 | 31,270 |
| Leading of 500kVA 22kVor433V transformer and accessories from unloaded location to new transformer location | - | HSN not specified by seller | 1 Each | 47,200 | 47,200 |
| Fixingtheradiators,conservators,HVandLV cable boxes and other accessories | - | HSN not specified by seller | 1 Each | 17,110 | 17,110 |
| Filteration of transformer oil using high vaccum oil filteration unit. | - | HSN not specified by seller | 1 Each | 7,670 | 7,670 |
| To and Fro transportation costs of FilterMachineor Tools, Equipments etc to site. | - | HSN not specified by seller | 1 Each | 5,310 | 5,310 |
| Erection of RTCC panel at MCC room, and providing connection between OLTC and RTCC panel including earthing of panel. | - | HSN not specified by seller | 1 Each | 5,900 | 5,900 |
| Supply and topping up of transformer oil | - | HSN not specified by seller | 100 Litre | 191.16 | 19,116 |
| Charges for oil Leak arresting from LV Bushings by Replacing the Gaskets | - | HSN not specified by seller | 1 Each | 13,865 | 13,865 |
| Supply and laying 19C by 2.5Sqmm Armoured Copper UG cable.1 from RTCC panel to OLTC. 2 Marshalling bo by to 22kV VCB panel | - | HSN not specified by seller | 50 Metre | 1,150.5 | 57,525 |
| Supply and laying 4C by 10Sqmm Armoured Al. UG cable from LT panel incomer to new Transformer DB | - | HSN not specified by seller | 15 Metre | 383.5 | 5,752.5 |
| Supply and laying 3C by 2.5Sqmm armoured Copper cable | - | HSN not specified by seller | 95 Metre | 304.44 | 28,921.8 |
| Supply and laying 4C by 2.5Sqmm Armoured Copper UG cable from transformer DB to OLTC | - | HSN not specified by seller | 30 Metre | 336.3 | 10,089 |
| Supply and laying 3R by 3.5C by 300Sqmm Armoured aluminium UG cable from transformer to MSB 25M by 3Run | - | HSN not specified by seller | 75 Metre | 2,271.5 | 170,362.5 |
| Single compression glanding and termination of 3.5C by 300Sqmm armoured Al. cable | - | HSN not specified by seller | 6 Each | 3,127 | 18,762 |
| Single compression glanding and termination of 4Cor3C by 2.5Sqmm armoured copper. cable | - | HSN not specified by seller | 12 Each | 442.5 | 5,310 |
| Single compression glanding and termination of 19C by 2.5Sqmm armoured copper. cable | - | HSN not specified by seller | 4 Each | 1,475 | 5,900 |
| Supply and providing 22kV, 185or300 Sqmm HT heat shrinkable indoor end termination kit | - | HSN not specified by seller | 1 Each | 20,060 | 20,060 |
| Double Earthing of transformer body, radiator, OLTC using 50 by 6mm Hot dip GI strip | - | HSN not specified by seller | 50 Each | 601.8 | 30,090 |
| Double Earthing of transformer neutral using 25 by 6mm copper strip, including cost of hardware, excavation of earth , backfilling etc. | - | HSN not specified by seller | 40 Each | 2,950 | 118,000 |
| MS fabrication for transformer supports, OLTC support, HTorLT cable support etc | - | HSN not specified by seller | 100 KG | 162.84 | 16,284 |
| Removal and refixing of chain link fence including MS supports, gate supports, removal of roofing sheet for easy movement of transformer | - | HSN not specified by seller | 1 Each | 10,915 | 10,915 |
| Transformer DB Supply and fixing of 4way TPN MCB DB with 40A 4P 100mA ELCBplusIsolator as incomer and 3Nos 16A DP MCB , 16A 3P MCB, 16A SP MCB, 10A SP MCB, earthing of DB etc. | - | HSN not specified by seller | 1 Each | 21,535 | 21,535 |
| Supply, fixing , wiring , testing and commisioning of Over voltage relay at the incomer ACB panel of MSB | - | HSN not specified by seller | 1 Each | 19,470 | 19,470 |
| Re-wiring and connetion of trip circuit in 22kV VCB panel, testing and commisioning | - | HSN not specified by seller | 1 Each | 2,950 | 2,950 |
| Supply and laying 2mm thick LT electromat for RTCC panelor transformer marshalling box | - | HSN not specified by seller | 4 Metre | 1,333.4 | 5,333.6 |
| Supply and fixing of 4P 25A MCB at incomer compartment of MSB including connection using 4Sqmm copper flexible wire | - | HSN not specified by seller | 1 Each | 2,950 | 2,950 |
| Excavation of soil for taking out the HT cable loop, pulling the cable from trench, backfilling after completion of job etc. | - | HSN not specified by seller | 1 Each | 3,540 | 3,540 |
| Excavation of cable trench for laying cable, providing one layer of bric and sand protection, backfilling etc. | - | HSN not specified by seller | 30 Metre | 1,121 | 33,630 |
| Construction of plint for 500kVA Transformer of size 1.2M by 1.2M by 1M L by W by H . Height of plinth form FFL is 30Cm. The work includes excavation, shuttering | - | HSN not specified by seller | 1 Each | 38,350 | 38,350 |
| CEA formalities including preparation of drawing, submission, arranging inspection, obtaining energisation order. The cost includes all incidental expenses. | - | HSN not specified by seller | 1 Each | 106,200 | 106,200 |
| All statutory feesor payments to KSEBL Paid on actual basis | - | HSN not specified by seller | 1 Each | 23,600 | 23,600 |
| Precommisioning testing of transformer | - | HSN not specified by seller | 1 Each | 29,500 | 29,500 |
| Supply, installation, testing , commissioning of LandT make 1000 A, 4P ACB 50kA with Microprocessor based release, UV and Shunt trip, | - | HSN not specified by seller | 1 Each | 306,800 | 306,800 |
| Replacement of Analog voltmeter in MCC panel-1 with digital VAFplusPF meter including panel door modification , control wiring connection etc | - | HSN not specified by seller | 1 Each | 4,307 | 4,307 |
| Replacement of Analog KWorKWHorPf meter in MCC panel-1 and Main lighting panel with digital MFM including panel door modification , control wiring connection etc | - | HSN not specified by seller | 2 Each | 6,490 | 12,980 |
| Retofitting of 630A TP MCCB in spare feeder for APFC panel including panel door modification, busbar connection, fixing Rotary operating handle mechanism fixing etc | - | HSN not specified by seller | 1 Each | 56,935 | 56,935 |
| Supply and laying of 1R by 3.5C by 300Sqmm Armoured Al. Ugh cable from newly installed 630A MCCB to APFC panel | - | HSN not specified by seller | 15 Metre | 2,271.5 | 34,072.5 |
| Single compression glanding and termination of 3.5C by 300Sqmm armoured Al. cable at APFC and MCC panel side | - | HSN not specified by seller | 1 Each | 3,127 | 3,127 |