| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.4 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹16.6 L+₹92,151 (5.86%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | NTR | ANDHRA PRADESH | 520001 | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹16.9 L+₹1.2 L (7.54%)Rejected-Finance A1 49 35 1 GOWTHAM RESIDENCY NGO S COLONY AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530016 | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹17.2 L+₹1.5 L (9.56%)Rejected-Finance | 4 | Rejected-Finance Not L-1 |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
3 Jun 2020, 6:00 pmClosed
Lt Col Vijay Singh GE ND
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
SPECIAL REPAIRS TO TOILETS IN BUILDING NO TB1 TB2 T36 AND T43L AT OLD MOV SITE AND PROVISION OF TOILET FOR SAILORS AT P25 ATC GARAGE AT INS DEGA UNDER AGE BR II OF GE ND VISAKHAPATNAM
2020_MES_320767_3
8877
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE ND Visakhapatnam
₹35,000
Yes
10 Jul 2020
5 May 2020
6 Jun 2020
5 May 2020
3 Jun 2020
6 May 2020
Amount
Surface dressing not exc 15cm deep and getting out in soft / loose soil
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M & L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in foundations, rafts, footings, plinth beams, basement slabs etc complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for TMT bars 5mm dia and over upto 10mm dia as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia as in stirrups, spacers, binders complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of plinth beams and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, columns and similar work for fair finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed.
Use and waste of formwork to to soffits of uspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, lintels and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 using old size bricks complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:4 duly mixed with and including cement water proofing compound @ 2% finished even and smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces finished even and smooth with out using extra cement complete all as directed.
M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection laid to slope in panels including joints filled with mastic filling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M & L for 75mm thick, PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in sub base complete all as specified and directed.
S & F coloured Glazed ceramic tiles of size 450x350x7mm thick as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:3 complete all as specified and directed.
S & F solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening as specified complete all as directed.
S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as specified and as directed.
S & F aluminium anodised barrel tower bolt of size 150mm long of extruded section complete all as specified
S & F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 of size 100mm complete all as specified and directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 100mm complete all as directed.
S & F 200mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as directed.
S & F 15 mm bore fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, complete all as specified and directed.
S & F 15mm dia fancy type, CP Stop valve, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all as directed
S & F PVC connection 15mm size with PTMT nuts of length 600mm complete all as directed.
S & F PVC valveless, syphonic action type, flushing cistern, 10 lit capacity, low level, white, with inlet, ball valve, float and handle including brackets and 32mm bore PVC flush pipe complete all as specified and directed.
S & F Vitreous China Semi-Pedestal pattern Anglo-indian type water closet, white (excluding fixing bolts, flushing cistern and flush pipe)complete all as specified and directed.
S & F 15mm dia Pillar tap, fancy type chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F Vitreous china wash basin, white flat back size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand including 32mm bore PTMT waste coupling, PVC waste pipe complete all as specified and directed.
S & F Vitreous China urinal flat back, of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing Urinal spreader of PTMT complete all as specified and directed.
S & F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified
S & F 110mm bore PVC (SWR) soil, waste and rain water pipes, Single socketed in any length with rubber ring joints fixed to walls laid in trenches / floors complete all as specified and directed.
S & F 75mm bore PVC (SWR) soil, waste and rain water pipes, Single socketed in any length with rubber ring joints fixed to walls laid in trenches / floors complete all as specified and directed.
M & L for 75mm bore PVC (SWR) vent cowl complete all as specified.
M & L for 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified.
Supplying and fixing of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on walls / ceiling or laying in floors complete all as specified and directed.
Supplying and fixing of 25mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on walls / ceiling or laying in floors complete all as specified and directed.
S & F PVC Ventilators frame work with multiple chamber hollow PVC section comprising of DWUF 405 sections with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube, the two vatted profiles are to be reinforced with 19 x 19mm MS square tube, 50% of bottom portion is fixed with 4mm thick pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass louvers and covered with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars complete all as specified and directed by the Engineer-in-Charge
M & L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directetd.
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directetd.
S & F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litres capacity, triple layered, hoisted and fixed in position including 20mm dia PTMT ball valve including dismantling existing water tank complete all as specified and directed.
M & L for Precast RCC 1:2:4, type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for manholes), shelves including necessary formwork, and the like and set in CM 1:4 including demolition of existing reinforced cement concrete of any description complete all as specified and directed.
M & L for TMT bars 6 to 8mm dia, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for salt glazed stone ware drain pipes 150mm dia grade 'A' laid in trenches and jointed complete all as specified and directed.
M & L for cement concrete 1:3:6 type C2 using 40 mm graded stone aggrerate as in bed concrete to drain pipes 150 mm bore including packing under & haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for internal dia of pipe 150mm complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
M & L for Anodised aluminium powder coated (Thickness of powder coating 50 micron) window and ventilator frame and shutters, side hung type without sash bars, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, etc complete all as specified and directed.
S & F 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 150mm complete all as directed.
S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated / 'Z' profile steel sheet of 0.50mm thick, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling existing asbestos cement sheets complete all as specified and directed.
Taking down old PVC flushing cistern
S & F in repairs Vitreous China urinal, half stall type white, with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S & F in repairs Vitreous china Squatting Pan, white, 'Orissa' pattern, of size 580 x 440mm, with integral foot rests including cast iron 'P' or 'S' trap and provision of cement concrete bedding and making good the disturbed surfaces to match with existing flooring complete all as directed.
S & F in repairs Wash down water closet (Pedestal pattern), Vitreous China white, plastic water closet seat of same colour closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repairs Health faucet with 1.0m Long flexible Stainless steel connecting pipe including necessary wall hook for EWC complete all as directed.
S & F glass shelf assembly consisting 5.5mm thick sheet glass of 60cm long, 12mm wide with and including suitable chromium plated bracket guard and railing complete all as directed.
S & F soap dish, vitreous china white of approximate size 160x160x90mm complete all as specified.
Taking down old wash hand basin
S & F PVC connection 15mm size with PTMT nuts of length 450mm complete all as directed.
S & F in repairs gun metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed including dismantling old gate valve complete all as specified and as directed.
Taking down old bib tap / stop cock / pillar tap of ant description
S & F in repairs 75mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as directed.
S & F Grating round 140mm dia of PTMT (Minimum weight 50gms) complete all as specified
S & F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litres capacity, triple layered, hoisted and fixed in position including 20mm dia PTMT ball valve including dismantling existing water tank complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish of the premises complete all as directed
Demolition of unreinforced cement concrete in any position of any description complete all as directed.
M & L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as directed.
M & L for 100mm thick, PCC 1:42:4, type D-2, using 40mm graded stone aggregate as in road / path / hard standing complete all as specified and directed.
S & F glass dividing strips 3mm thick, 38mm wide complete all as directed
M & L for Machine pressed precast cement conctete coloured interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade over and including 50mm thick sand complete all as specified and directed.
M & L for PCC 1:3:6, type C-1, using 20mm graded stone aggregate as in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
Taking down rain water pipes with all fittings complete all as specified
M & L for 110mm bore PVC (SWR) bends any radius with oval access door complete all as specified.
M & L for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified.
S & F GI tubing 15mm bore, medium grade with all fittings and fixtures fixed to walls and ceilings or laid in floors including taking down old GI pipe complete all as specified and directed.
S & F GI tubing 20mm bore, medium grade with all fittings and fixtures fixed to walls and ceilings or laid in floors including taking down old GI pipe complete all as specified and directed.
Taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directetd.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Dismantling reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as directed
M & L for salt glazed stone ware drain pipes 100mm dia grade 'A' laid in trenches and jointed complete including demolition and breaking up existing drain pipes set in cement mortar complete all as specified and directed.
M & L for cement concrete 1:3:6 type C2 using 40 mm graded stone aggrerate as in bed concrete to drain pipes 100 mm bore including packing under & haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of 20mm dia medium grade including concealed terminal boxes made of 2mm thick MS sheet duly covered with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan / bell point / 5 Amps socket point controlled by one switch complete all as specified and directed. [Note: Quoted rate is inclusive for cutting grooves / chases, pinning and making good disturbed surfaces complete]
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of 20mm dia medium grade including concealed terminal boxes made of 2mm thick MS sheet duly covered with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for Power socket point on independent board complete all as specified and directed. [Note: Quoted rate is inclusive for cutting grooves / chases, pinning and making good disturbed surfaces complete]
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F LED tube light fittings, 4 feet long, wall mounted LED batten WH 5700K to 6200K and 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F LED tube light fittings, 2 feet long of 900 to 1000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light 2500 Lumens LED Pressure die cast aluminium housing IP 65 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe not less than 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
S & F exhaust fan, AC, single phase, 230Volts of size 300mm sweep with louvers, heavy duty, suitable for 50Hz, free air flow complete including provision of 3 core flexible copper cable of suitable size from ceiling rose to fan complete all as specified and directed by the Engineer-in-Charge.
S & F MCB DB, SPN, 8 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F RCCB, Double Pole, 30mA, 40 Amps
S & F MCB SP 6 to 32 Amps, 240 Volts
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls complete all as specified and directed.
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
Supplying and laying unreinforced precast concrete cable cover, factory made class LV, Type-1 flat, size 250mmx150mmx40mm for protection of cable complete all as specified and as directed.
S & F GI pipe 50mm dia light grade for cable protection fixed in any position complete all as directed
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc complete all as directed
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of 20mm dia medium grade including terminal boxes made of 2mm thick MS sheet duly covered with 3mm thick hylem sheet top cover including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan / bell point / 5 Amps socket point controlled by one switch complete all as specified and directed.
S & F in repairs MCB DB, SPN, 4 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
Taking down existing LED light fittings from any position and refixing the same in original position complete all as directed
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
sai ganesh enterprises
MOUNIKA ENTERPRISES
N V S S K N SIVA PRASAD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .