Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.9 L+₹1.9 L (6.73%)Rejected-Finance BANKODI BANKODI BANKODI KALYANPUR JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹29.9 L+₹1.9 L (6.80%)Rejected-Finance VILL BHELOWATER PO BORJULI PS RANGAPARA DIST SONITPUR ASSAM 784504 | SONITPUR | ASSAM | 784504 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹30.1 L+₹2.1 L (7.55%)Rejected-Finance GARUBANDHA MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹31.5 L+₹3.5 L (12.5%)Rejected-Finance RANGAPARA TOWN WARD NO 1 PS PO RANGAPARA DIST SONITPUR ASSAM | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Sneh Construction Co L2 | Maa Mira Enterprise L1 | M/S Jiban Krishan Das and Co L6 | United Traders L5 | S M STORE L7 | S H ENTERPRISES L3 | M/s AKRITI ENTERPRISE L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Note:- Concealed conduit in RCC slab/beam shall not be not be taken. | 1,302 | Per Point | 5 ₹6,510 | 2 ₹2,604 Lowest | 18 ₹23,436 | 6 ₹7,812 | 10 ₹13,020 | 10 ₹13,020 | 10 ₹13,020 |
| 2.00 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. | 66 | Each | 5 ₹330 | 2 ₹132 Lowest | 40 ₹2,640 | 11 ₹726 | 50 ₹3,300 | 10 ₹660 | 8 ₹528 |
| 3.00 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed. | 1,020 | RM | 5 ₹5,100 | 2 ₹2,040 Lowest | 20 ₹20,400 | 4 ₹4,080 | 30 ₹30,600 | 10 ₹10,200 | 4 ₹4,080 |
| 4.00 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.
Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
(ii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted
(iii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. | 525 | Per Point | 570 ₹2,99,250 Lowest | 650 ₹3,41,250 | 570 ₹2,99,250 Lowest | 803 ₹4,21,575 | 600 ₹3,15,000 | 700 ₹3,67,500 | 610 ₹3,20,250 |
| 5.00 | All as per item No 4 here-in-above but One socket out let 5/6 amps point on the same board | 90 | Per Point | 80 ₹7,200 Lowest | 200 ₹18,000 | 180 ₹16,200 | 335 ₹30,150 | 580 ₹52,200 | 150 ₹13,500 | 180 ₹16,200 |
| 6.00 | All as per item No 4 here-in-above but One socket out let 5/6 amps point on the independent board | 225 | Per Point | 630 ₹1,41,750 | 650 ₹1,46,250 | 570 ₹1,28,250 Lowest | 803 ₹1,80,675 | 600 ₹1,35,000 | 750 ₹1,68,750 | 680 ₹1,53,000 |
| 7.00 | All as per item No 4 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. | 8 | Per Point | 750 ₹6,000 | 1,000 ₹8,000 | 700 ₹5,600 Lowest | 876 ₹7,008 | 700 ₹5,600 Lowest | 750 ₹6,000 | 730 ₹5,840 |
| 8.00 | M&L concealed point wiring for One one socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate fittings] concealed in walls, with and including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.
Notes:- (i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
(ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.
(iii) Cost of cutting chases in wall and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted. | 90 | Per Point | 830 ₹74,700 | 800 ₹72,000 | 660 ₹59,400 Lowest | 937 ₹84,330 | 700 ₹63,000 | 800 ₹72,000 | 740 ₹66,600 |
| 9.00 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.
Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. | 175 | Per Point | 470 ₹82,250 Lowest | 600 ₹1,05,000 | 550 ₹96,250 | 736 ₹1,28,800 | 600 ₹1,05,000 | 500 ₹87,500 | 525 ₹91,875 |
| 10.00 | All as per item No 9 here-in-above but One socket out let 5/6 amps point on the same board | 35 | Per Point | 80 ₹2,800 Lowest | 120 ₹4,200 | 150 ₹5,250 | 335 ₹11,725 | 600 ₹21,000 | 150 ₹5,250 | 105 ₹3,675 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
3 Jan 2026, 6:00 pmClosed
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIRS TO INTERNAL WIRING INCLUDING FITTINGS FIXTURES TO OFFRS MD ACCN UNDER GE MISSAMARI
2025_MES_744389_1
8603/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MISSAMARI
₹88,000
Yes
19 Feb 2026
13 Dec 2025
5 Jan 2026
13 Dec 2025
3 Jan 2026
27 Dec 2025
13 Dec 2025 - 20 Dec 2025
S&F in repair, MCCB 4P 100 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KA complete all as specified and as direct.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed.
S&F in repair, Cable jointing kit LT 1100 Volts cable End joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed.
All as per item No 4 here-in-above but One socket out let 5/6 amps point on the independent board
M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed
S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed.
S&F LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified.
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F Call Bell, AC, 230 volts, single pole complete all as specified and as directed.
S&F in repair, ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body complete all as specified and directed.
S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) 6500K, with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed.
Supply,laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Taking up the existing unservicable UG cable of any type/ description as existing at site complete all as directed Note :Earthwork will be measured and paid seperately.
M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
S&F in repair PVC square box 170mm x 100mm including refixing of old switch socket complete all as specified and as directed.
S&F in repair PVC square box 200mm x 150mm including refixing of old switch socket complete all as specified and as directed.
S&F in repair PVC square box 300mm x 250mm including refixing of old switch socket complete all as specified and as directed.
Relaying Serviceable LT UG XLPE cable of size 3.5 core x 16/25 sq mm obtained from item no. 53 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable all as specified and directed. Note:- Serviceable Cable obtained from Item No 54 here-in-before
S&F in repair 25x16mm, medium grade, PVC casing and capping duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced.
Taking down and Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/ connector to fan complete all as directed
S&F in repair PVC insulated sheathed multicore cable copper conductor 1.00 Sqmm, 2 Core complete all as specified and as directed
S&F in repair PVC insulated sheathed multicore cable copper conductor 1.50 Sqmm, 3 Core complete all as specified and as directed
M&L 40mm bore GI pipe light grade with all necessary fittings (ISI marked), clamps, nuts bolts etc as required as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed.
S&F Modular Switch 1 way 6 Amps, 1 module, complet
e all as specified and directed.
S&F Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed.
Per Point
S&F in repair, MCCB 4P 125 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KA complete all as specified and as direct.
S&F in repair, VTPN DB, 08 Way, double door,Metal door ,IP-43 IK 09, with MCCB as (upto 125 Amps) incomer, and MCB;s as Outgoing , 250 Amps rated copper bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces including complete all as specified and as direct. Note:- MCCB;s/MCB's required as Outgoing shall be measured and pair seperately under appropiate items
S&F Modular Switch two way 5/6 Amp, 1 module, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
PRICE SCHEDULE (a) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) (b) Estimated rate Column is for Department use only. (Note: Credit amount if any vide Credit schedule shall be deducted from the total quoted amount of Sch 'A' to arrive total contract sum.) (c) The Tenderers attention is drawn to the fact that the Work Order No 1 shall be placed after submission of performance security of requisite amount in favor of Accepting Officer.
M&L Concealed sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 2 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Four runs of PVC wire, Two run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
M&L Concealed sub-main wiring alongwith earth wire of size of 4 x 10.0 sq. mm + 2 x 10.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Four runs of PVC wire, Two run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
Tender8603.rar
Tender Documents • 0.67 MB
BOQ_833518.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .