Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 Cr+₹58.8 L (40.7%)Admitted-Finance 10 BRIJ VATIKA LAXMIPURA JAIPUR RAJASTHAN 302022 | JAIPUR | JAIPUR | RAJASTHAN | 302022 | ₹2.0 Cr+₹58.8 L (40.7%) | L2 | Admitted-Finance |
| 3 | L3₹2.2 Cr+₹79.8 L (55.2%)Admitted-Finance | ₹2.2 Cr+₹79.8 L (55.2%) | L3 | Admitted-Finance |
| 4 | L4₹2.6 Cr+₹1.1 Cr (76.9%)Admitted-Finance NEAR LIONS CLUB KOTHAMANGALAM ERNAKULAM KERALA 686691 | ERNAKULAM | KERALA | 686691 | ₹2.6 Cr+₹1.1 Cr (76.9%) | L4 | Admitted-Finance |
| 5 | L5₹2.7 Cr+₹1.3 Cr (89.2%)Admitted-Finance | ₹2.7 Cr+₹1.3 Cr (89.2%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CORROSION MATTERS L7 | SHOW AND SONS ENTERPRISE L3 | Silverline Integrity Services L6 | SARK EPC Projects Pvt.Ltd. L8 | Technocorr Engineering Pvt Ltd L4 | R K ENTERPRISES L2 | UHS HIGHTECH SYSTEM PVT LTD L1 | SM CORROSION SERVICES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & Installation of Manual Test Station complete with lower bend and with PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC. | 10 | EA | 29,000 ₹3,42,200 | 17,300 ₹2,04,140 | 18,942 ₹2,23,515.6 | 28,000 ₹3,30,400 | 21,000 ₹2,47,800 | 6,500 ₹76,700 Lowest | 14,800 ₹1,74,640 | 16,000 ₹1,88,800 |
| 2.00 | Supply & Installation of Manual Test Station with out lower bend & with out PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC. | 10 | EA | 24,000 ₹2,83,200 | 13,650 ₹1,61,070 | 10,942 ₹1,29,115.6 | 23,000 ₹2,71,400 | 15,000 ₹1,77,000 | 6,500 ₹76,700 | 5,000 ₹59,000 Lowest | 10,000 ₹1,18,000 |
| 3.00 | Shifting of Manual Test Station along with foundation and cable to suitable location as per instruction of EIC. (Excluding additional Cable if required). | 15 | EA | 20,000 ₹3,54,000 | 5,800 ₹1,02,660 | 8,642 ₹1,52,963.4 | 19,000 ₹3,36,300 | 12,000 ₹2,12,400 | 6,000 ₹1,06,200 | 3,000 ₹53,100 Lowest | 3,500 ₹61,950 |
| 4.00 | Repairing of Manual Test Stations foundation with supply and replacement of foundation bolts and nuts including labour,tools,tackles consumeables like cement,sand aggregates etc complete in all respect as per scope of work, specifications and direction of EIC. | 10 | EA | 20,000 ₹2,36,000 | 2,880 ₹33,984 | 3,200 ₹37,760 | 10,000 ₹1,18,000 | 4,000 ₹47,200 | 1,200 ₹14,160 Lowest | 3,000 ₹35,400 | 4,500 ₹53,100 |
| 5.00 | Repairing of Manual Test Stations including supply and replacement of damaged door, door locks,terminal plate ,diagram plate,neoprene gasket, brass links cable identification ferrules etc in Manual Test Station with proper cable termination, cable jointing,lugs with numbering of Test Station complete in all respect including labour,tools,tackles,consumeables like MS /brass bolts, nuts, washers,insulation tape etc.as per scope of work, specifications and the direction of EIC. | 10 | EA | 16,000 ₹1,88,800 | 3,550 ₹41,890 | 3,442 ₹40,615.6 | 12,000 ₹1,41,600 | 4,000 ₹47,200 | 2,200 ₹25,960 Lowest | 3,000 ₹35,400 | 3,500 ₹41,300 |
| 6.00 | Supply & replacement of damaged/missing locks in Manual Test Station including labor, consumables, tools & tackles as per drawings, specifications & instructions of EIC. | 15 | EA | 6,000 ₹1,06,200 | 750 ₹13,275 Lowest | 1,600 ₹28,320 | 8,500 ₹1,50,450 | 1,000 ₹17,700 | 1,300 ₹23,010 | 3,000 ₹53,100 | 1,200 ₹21,240 |
| 7.00 | Supply & replacement of damaged/missing doors in Manual Test Station including lock,neoprene gasket, diagram plate labor, consumables , tools & tackles as per drawings, specifications and instructions of EIC. | 15 | EA | 6,000 ₹1,06,200 | 3,550 ₹62,835 | 3,442 ₹60,923.4 | 8,500 ₹1,50,450 | 4,000 ₹70,800 | 2,100 ₹37,170 | 2,500 ₹44,250 | 1,200 ₹21,240 Lowest |
| 8.00 | Supply & installation of damaged/missing terminal plates (all types) with M10 brass studs, washers, links, lugs & nuts, tools & tackles and consumables including labor as per instruction of EIC. | 15 | EA | 4,000 ₹70,800 | 550 ₹9,735 | 2,912 ₹51,542.4 | 8,500 ₹1,50,450 | 1,000 ₹17,700 | 220 ₹3,894 Lowest | 2,500 ₹44,250 | 900 ₹15,930 |
| 9.00 | Supply and Fixing of diagram plate in the existing test station of all types complete in all respect including labour,tools,tackles ,consumeables etc. as per scope of work specifications and the direction of EIC. | 15 | EA | 4,000 ₹70,800 | 250 ₹4,425 Lowest | 550 ₹9,735 | 2,500 ₹44,250 | 500 ₹8,850 | 650 ₹11,505 | 500 ₹8,850 | 850 ₹15,045 |
| 10.00 | Supply, installation, testing and commissioning of Anode Lead Junction Box (ALJB) including required backelite plate brass nut bolts, port type resistor & shunt arrangement, civil works with materials as per EIC. | 1 | EA | 34,000 ₹40,120 | 23,800 ₹28,084 | 28,400 ₹33,512 | 32,000 ₹37,760 | 45,000 ₹53,100 | 10,500 ₹12,390 Lowest | 15,000 ₹17,700 | 45,000 ₹53,100 |
Tender Value
Refer Docs
EMD Value
₹3.8 L
Closing Date
20 Jul 2026, 3:00 pmClosed
Renuka Gudhe
GAIL GAS LTD
ANNUAL RATE CONTRACT (ARC) FOR MAINTENANCE OF CATHODIC PROTECTION (CP) AND ASSOCIATE SYSTEM FOR SONIPAT, MEERUT AND DEWAS FOR 2 YEARS
2026_GAILG_281719_1
GAIL GAS/NOIDA/RU/8716/26-27/24
Open Tender
Miscellaneous Services
Item Rate
730 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹3.8 L
Yes
THROUGH VC
7 Sept 2026
29 Jun 2026
21 Jul 2026
29 Jun 2026
20 Jul 2026
8 Jul 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1 | Supply & Installation of Manual Test Station complete with lower bend and with PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC. | 10 | EA | - | - | 0.18% |
| 2 | Supply & Installation of Manual Test Station with out lower bend & with out PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC. | 10 | EA | - | - | 0.18% |
| 3 | Shifting of Manual Test Station along with foundation and cable to suitable location as per instruction of EIC. (Excluding additional Cable if required). | 15 | EA | - | - | 0.18% |
| 4 | Repairing of Manual Test Stations foundation with supply and replacement of foundation bolts and nuts including labour,tools,tackles consumeables like cement,sand aggregates etc complete in all respect as per scope of work, specifications and direction of EIC. | 10 | EA | - | - | 0.18% |
| 5 | Repairing of Manual Test Stations including supply and replacement of damaged door, door locks,terminal plate ,diagram plate,neoprene gasket, brass links cable identification ferrules etc in Manual Test Station with proper cable termination, cable jointing,lugs with numbering of Test Station complete in all respect including labour,tools,tackles,consumeables like MS /brass bolts, nuts, washers,insulation tape etc.as per scope of work, specifications and the direction of EIC. | 10 | EA | - | - | 0.18% |
| 6 | Supply & replacement of damaged/missing locks in Manual Test Station including labor, consumables, tools & tackles as per drawings, specifications & instructions of EIC. | 15 | EA | - | - | 0.18% |
| 7 | Supply & replacement of damaged/missing doors in Manual Test Station including lock,neoprene gasket, diagram plate labor, consumables , tools & tackles as per drawings, specifications and instructions of EIC. | 15 | EA | - | - | 0.18% |
| 8 | Supply & installation of damaged/missing terminal plates (all types) with M10 brass studs, washers, links, lugs & nuts, tools & tackles and consumables including labor as per instruction of EIC. | 15 | EA | - | - | 0.18% |
| 9 | Supply and Fixing of diagram plate in the existing test station of all types complete in all respect including labour,tools,tackles ,consumeables etc. as per scope of work specifications and the direction of EIC. | 15 | EA | - | - | 0.18% |
| 10 | Supply, installation, testing and commissioning of Anode Lead Junction Box (ALJB) including required backelite plate brass nut bolts, port type resistor & shunt arrangement, civil works with materials as per EIC. | 1 | EA | - | - | 0.18% |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
vol_II.pdf
Tender Documents • 4.65 MB
vol_I.pdf
Tender Documents • 4.24 MB
BOQ_329391.xls
BOQ • 0.61 MB
Corrigendum01.pdf
PDF • 12.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .