| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.0 CrAccepted-AOC | ₹84.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹97.0 CrRejected-AOC 825 GANDHI CHOWK RANIKHET ALMORA | ₹97.0 Cr | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Does not fullfil the bidding capacity requirement as per tender. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Does not fullfil the bidding capacity requirement as per tender. |
Tender Value
₹65.2 Cr
EMD Value
₹1.3 Cr
Closing Date
19 Jan 2024, 5:00 pmClosed
SE, C and P, UPCL
C and P, Urja Bhawan, Kanwali Road,Dehradun
Loss Reduction Work under Revamped Distribution Sector Scheme EDC Karanprayag Package-E
2023_UPCLC_65679_5
CCP-I/41/2023-2024
Open Tender
Electrical Works
730 days
As per tender conditions
As per tender conditions
6 documents required · 6 mandatory
₹29,500
Executive Engineer (HQ), UPCL
₹1.3 Cr
Urja Bhawan, Kanwali Road,Dehradun
8 Aug 2024
18 Nov 2023
20 Jan 2024
18 Nov 2023
19 Jan 2024
28 Dec 2023
5 Dec 2023
Amount
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Panther Conductor
33 KV AL-59 ACS XLPE (240sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33 kV Composite Polymer Disc Insulator B & S type
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (240 sqmm MVCC to 240 sqmm MVCC)
IPC (Bare conductor to 240 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Panther Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Composite Polymer Disc Insulator B & S type
33kV Disc fitting for Panther conductor 90 KN B&S type
ACSR PANTHER Conductor for Phase with 3% sag.
Aluminum Binding wire & tape
Jointing Sleeve for PANTHER Conductor
PG clamp/Wedge type for Panther
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Replacement of LT Bare Conductor to AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x70+1x50 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (70 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x70+1x50 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 50 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x50+1x35 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (50 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x50+1x35 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 35 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 1x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 1x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed LT AB Cable
Reconductoring of LT AB Cable 3x70+1x50 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (70 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x70+1x50 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 50 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Description of Work / Item(s)
Amount
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Panther Conductor
33 KV AL-59 ACS XLPE (240sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33 kV Composite Polymer Disc Insulator B & S type
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (240 sqmm MVCC to 240 sqmm MVCC)
IPC (Bare conductor to 240 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Panther Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Composite Polymer Disc Insulator B & S type
33kV Disc fitting for Panther conductor 90 KN B&S type
ACSR PANTHER Conductor for Phase with 3% sag.
Aluminum Binding wire & tape
Jointing Sleeve for PANTHER Conductor
PG clamp/Wedge type for Panther
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Replacement of LT Bare Conductor to AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x70+1x50 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (70 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x70+1x50 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 50 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x50+1x35 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (50 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x50+1x35 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 35 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 1x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 1x16+1x25 Sq.mm.
1x16 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks/Street light.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed LT AB Cable
Reconductoring of LT AB Cable 3x70+1x50 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (70 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x70+1x50 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 50 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
M/s Kashmirilal Constructions Pvt. Ltd.
M/s Kashmirilal Constructions Pvt. Ltd.
T S Power Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid