| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.2 L+₹9.4 L (36.4%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical The firm is not enlisted in categary c(i) |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
15 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
COMPREHENSIVE MAINT/ REPAIR/ REPLACEMENT OF COOLING APPLIANCES AT AF STATION WADSAR
2023_MES_596916_1
8914/2023-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
WADSAR
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹48,000
Yes
10 Aug 2023
20 May 2023
17 Jun 2023
20 May 2023
15 Jun 2023
2 Jun 2023
20 May 2023 - 1 Jun 2023
Amount
Window / split type A/C (Section I)
Taking down old unsv sealed compressor of Window type Air Conditioner 1.5 / 2.0 Ton capacity of any make and S & F in replacement new sealed compressor of existing size, make and capacity, connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and including charging of Refrigerant gas, compressor oil, testing commissioning complete all as directed by Engineer-in-Charge.
All as per item No 1.01 here in before but 1.5/2.0 Ton split AC.
All as per item No 1.01 here in before but 3.0/3.5 TR Tower AC.
All as per item No 1.01 here in before but 5.5 TR suitable for 11 TR AC of existing size.
All as per item No 1.01 here in before but suitable for 15 TR AC of existing size.
S&F in replacement of running capacitor 36 mfd complete all as specified and directed.
S&F in replacement of starting capacitor 100-120 mfd complete all as specified and directed.
S&F in replacement of starting relay for 1.5 ton/2 ton ac complete all as specified and directed.
S&F in replacement of thermostat switch for window/split/tower type air conditioner any capacity complete all as specified and directed.
S&F in replacement of over load protector for window/split/tower type air conditioner any capacity complete all as specified and directed.
S&F in replacement of pvc air filter suitable for split/tower/package type air conditioner complete all as specified and directed.
S&F in replacement of blower PVC with motor suitable for 1.5 /2.0 Ton window/split type air conditioner complete all as specified and directed by Engineer-in-Charge.
All as per item No 1.12 here in before but 3.0/3.5 TR Tower AC of existing size.
All as per item No 1.12 here in before but suitable for 11 TR AC of existing size.
All as per item No 1.12 here in before but suitable for 15 TR AC of existing size.
S&F in replacement of condenser fan blade suitable for 1.5/2.0 Ton window/split type air conditioner complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of condenser fan motor 1/05 HP 230 volt AC single phase double shaft suitable for 1.5/2.0 ton window type AC complete all as specified and directed.
S&F in replacement of condenser fan motor single phase 230 volts suitable for split type AC 1.5/2.0 ton capacity of existing make complete all as specified and directed by Engineer-in-Charge.
All as per item No 1.18 here in before but 3.0/3.5 TR Tower AC of existing size.
All as per item No 1.18 here in before but suitable for 11 TR AC of existing size.
All as per item No 1.18 here in before but suitable for 15 TR AC of existing size.
S&F in repairs condenser of window/ split type air conditioner capacity 1.5/2.0 Ton as per existing complete all as specified and directed.
All as per item No 1.22 here in before but 3.0/3.5 TR Tower AC of existing size.
All as per item No 1.22 here in before but suitable for 11 TR AC of existing size.
All as per item No 1.22 here in before but suitable for 15 TR AC of existing size.
S&F in replacement of sheet metal enclosure PS-16 plugs and sockets, 20 Amps 240 volts grade, confirming to IEC 309 with IP-44 Protection, comprising of 20 Amps plug and socket box, flush mounting single pole and earth complete all as specified and directed.
S&F in replacement of copper cooling coil assembly suitable for window type air conditioner of existing make including charging of refrigerant gas R-22, testing, commissioning complete all as specified and as directed by Engineer-in-Charge.
M & L for servecing of spilt type air conditioner of any make /size /capacity at site, dismantling all electrical controls and components and cleaning the whole OD and ID unit with electric blower and spraying clean water with descaling agent in both side of cooling coil and condenser, brush cleaning with Nylon brush and washing with clean water complete, Refixing the covers and making electrical connection of all the controls and components, installing the same on site testing, commissioning complete all as specified and directed by Engineer-in-Charge. Note :- (i) Contractor will appoint technicians and helper for day to day complaint attending and servicing and cost of the same included in this item and nothing will be paid extra on this account . (ii) Any spare part required for repair of ACs will be measured and paid separateley under respective items of BOQ.
M&L for gas charging in window/ split type Air conditioner suitable for 1.5 /2.0 Ton of any make including pressure testing, leakage , rectification, vacuumising and testing commissioning complete all as specified and directed by Engineer-in-Charge.
All as per item No 1.29 here in before but suitable for 3.0/3.5 TR Tower AC.
All as per item No 1.29 here in before but suitable for 11 TR AC.
All as per item No 1.29 here in before but suitable for 15 TR AC.
M&L in replacement of revolving motor kit for louvers (for A/C Grill) in window type A/C 1.5 T complete all as specified and directed.
Supply and fix in replacement of PCB board suitable for split AC 1.5/2.0 ton of existing makes complete all as specified and directed.
All as per item No 1.34 here in before but suitable for 3.0/3.5 TR Tower AC.
All as per item No 1.34 here in before but suitable for 11 TR AC.
All as per item No 1.34 here in before but suitable for 15 TR AC.
M & L in repair for framed brackets of angle or tees with web and flanges out to shape drilled and counter sunk or screw including bending and welding angle as necessary riveting etc confirming to Fe 290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
S&F in replacement Drain pipe PVC for split type AC any capacity minimum 1.5 Mtr length (as per sample) complete all as specified and directed.
S&F in replacement Indoor unit complete suitable for 1.5/2.0Ton Split Type Air conditioner complete (as per sample) complete all as specified and directed.
S&F in replacement Invertor type PCB including remote control for remote sensing and operation suitable for 1.5/2.0Ton Split Type Air conditioner complete all as specified and directed.
S&F in replacement Universal Remote control suitable for Split type AC 1.5/2.0 ton complete all as specified and directed.
S&F in replacement Swing motor suitable for Split type AC 1.5/2.0 ton complete all as specified and directed.
S&F in replacement starting relay for 3.5 ton AC complete all as specified and directed.
S&F in replacement starting relay for 11 ton AC complete all as specified and directed.
S&F in replacement starting relay for 15 ton AC complete all as specified and directed.
S&F in replacement Copper tube 15 mm bore complete all as specified and directed.
All as per item No 1.47 here in before but 9.5 mm bore.
All as per item No 1.47 here in before but 12.7 mm bore.
All as per item No 1.47 here in before but 6.3 mm bore.
M&L for Foam armour for AC copper tubing alongwith taping complete all as specified and directed.
M & L for rewinding of outdoor fan motor of 11 TR AC with super enameled copper wire of suitable gauge, varnishing including replacement of copper bushing and testing after connecting as directed.
All as per item No 1.52 here in before but indoor fan motor.
S&F in repair 230V, AC, 50Hz, 25 Amp with cyclic timer 3-999 minute programmable interval between two AC (programmeable alternate operation of AC-01 and AC-02) AC ON indication for AC-01 and AC-02 power on indication single phase and two input terminal etc complete all as specified and directed.
S&F in replacement of old rusted AC mounting bracket with new 24 inch heavy duty wall mounted bracket load bearing capacity upto 50 kg all as per the direction of Engr-in-charge.
S&F in repair Display panel with microprocessor unit in replacement for Chiller Unit 80 TR complete all as specified and directed. Make - Voltas or equivalent as approved by GE.
M & L for Compressor Oil of AC Plant complete all as specified and directed.
S&F in repair complete Filter pad set for AHU complete all as specified and directed.
M & L for rewinding of induction motor 12.5/15 HP capacity, three phase, 50 Hz monoblock /coupled centrifugal pump with super enamel copper wire of existing guage with and refixing the same at site complete all as specified and directed.
M & L for taking out complete pump & motor unit of capacity 12.5/15 Hp from installed position overhauling the pump unit and replacement of bearings and refixing the same at site complete all as specified and directed.
S&F in replacement of butter fly valve PN 1.6 of size 150 mm dia complete all as specified and directed by Engr in Charge.
All as per item No 1.61 here in before but 100 mm dia
All as per item No 1.61 here in before but 200 mm dia
S&F in replacement of NRV PN 1.6 of size 150 mm dia complete all as specified and directed by Engr in Charge.
All as per item No 1.64 here in before but 100 mm dia.
All as per item No 1.64 here in before but 200 mm dia.
S&F in replacement of modulating/mixing valve of size 150 mm dia, complete all as specified and directed by Engr in Charge.
All as per item No 1.67 here in before but 100 mm dia.
M & L in repair for Compressor unit of compatible for 80 TR chiller unit complete all as specified and directed.
M & L in repair for type IPDS50 differential pressure swicth unit of AC Plant complete all as specified and directed.
M & L in repair for chill dp swict unit of AC Plant complete all as specified and directed.
M & L for replacement of humidity controll unit for AHU of size 8000 to 15000 CFM complete all as specified and directed.
M & L for replacment of pressure gauge meter of AC Plant complete all as specified and directed.
M & L for replacment of temperature meter of AC Plant complete all as specified and directed.
M&L for gas charging of 80 TR unit for AC Plant of any make including pressure testing, leakage, rectification, vacuumising and testing commissioning complete all as specified and directed by Engineer-in-Charge.
M & L for replacment of Descaling condensor/chiller of AC plant complete all as specified and directed.
S&F in repair louvers for cooling tower as per existing size complete all as specified and directed.
S&F in repair air washers unit for cooling tower as per existing size complete all as specified and directed.
S&F in repair cooling tower fills as per existing size complete all as specified and directed.
S&F in repair vent grill for AC duct as per existing size complete all as specified and directed.
M&L for painting of 100 to 200 mm pipe with synthetic enamal paint and arrow marking as per exsting color coding complete all as specified and directed.
M&L for insulation of chilled water pipe of 100mm to 150mm dia in AC plant with polyutherine foam and insulation foil cover of existing thickness complete all as specified and directed.
M&L for insulation of air duct with polyutherine foam and insulation foil cover of existing thickness complete all as specified and directed.
M&L for repairing of leakage in air duct with weilding, finishing and applying insulation after finishing job complete all as specified and directed.
S&F in repair canvas for AHU to duct connection of existing size and type complete all as specified and directed.
Comprehensive annual maintenance for (80 x 3 = 240 TR) Scroll type refrigeration Compressor with R407c refrigerant with Microprocessor panel and suction and Discharge valves, mono block pump for chilled water and condenser water any capacity, including draft type 160 TR cooling tower including all valves and pipes complete, Air handling unit of capacity from 8000 to 15 CFM, fresh air louvers with bird screen and heater bank of capacity from 3 to 18 KW , Pan humidifier of capacity from 1. 5 to 2.0 KW and complete power system supply of the AC Plant including sub panels complete all as specified and directed by the engineer in charge.
SCOPE COVER UNDER AMC:- (i) Check oil level in the compressor. (ii) Check liquid sight glasses to determine if there is a refrigerant shortage. (iii) Inspecting the unit for leaks with a soap solution. (iv) Inspect entire system for any unusual conditions such as noise, vibration, etc. (v) Check the system operating pressure and temperatures to ensure proper operating conditions. (vi) Check Evaporator and condenser approach. (vii) Check chilled water flow by checking pressure drop across the chiller. (viii) Compare the chilled water temperature at full load with the chilled water temperature control. (ix) Inspect all safety controls and adjust if required. (x) Inspect all operating control and sequence of operation. (xi) Review daily operating log maintained by Customers operating personnel and instruct operating engineer as required. (xii) Topping of Refrigerant and Oil if required under normal wear and tear. (xiii) Yearly health report of the chiller and suggestions for improvement. (xiv) Yearly Condenser water analysis. (xv) Motor Insulation Checks. (xvi) Yearly adjustments of controls if required.
AMC agency will arrange require tools for attend routine services/minor breakdown call like an adjustable spanner, clamp meter, pressure Gauge with charging line, Digital Temperature gun, leak detector,`ring/fix spanner set, Allen key set, screw driver set, motor insulation meter, software support if require. (Air blower & cotton waste provide by agency during routine service).AMC agency will also arrange require equipment’s for attend major breakdown call like as a vaccum pump, Digital Vaccum gauge, Refrigerant recovery unit, Empty refrigerant cylinders, dehydration tank, and require spanners.
Note:-(i) Refrizerant and Compressor Oil will be paid under respective item of BOQ (ii) AMC will covered all spares like as electrical, mechanical (motor), control, Hardware & software periodical inspection and service of the plant Water cooled scroll Chillers ( 80 x 3 = 240 TR, VOLTAS) once in a quarter as detailed below : (a )Inspect and check the machines performance once in three months. (b) Check refrigerant leakage of the machines. (c ) Rectify the system defect causing leakage. (d) Carry the proper functioning of microprocessor and take the control test (e) Check the electricla components , and terminals for proper tightness. (f) Clean electrical panel periodically. (g) Check functioning of water flow switch and interlock in the system. (h) Check all safety controls for proper functioning and replace if the same is defective (j) All the breakdowns including compressor failure will be attended. (k) Check refrigerant filter and drier core, replace the same , if found necessary. (l) Supply of electrical parts expect electrical spares for incoming panel. (Like fuses, incoming electrical controls , cables etc.)
Monthly inspection and service of the chilled water pump, condenser pump ( 10 x 3 = 30 Hp ) as detailed below : (a) Check the alignment and conditions of coupling to prevent damage to shaft and impeller. (b) Lubricate bearings with grease guns. (c ) Replace gland thread if required. (d) Check lubricant oil level and make up the oil if required. (e) Check packing and mechanical seals for leakage.
Half yearly inspection and service for pumps as detailed below. (a) Inspect shaft sleeves,shaft, bearings , bearing housing and overhauling of all pumps. (b) The impeller and shaft to be repaired and made functional. If they are found not repairable, then same will be replaced . (c) The packing, mechanical seal, bush, bearing, Shaft sleeves, coupling etc. If found faulty to be replaced by the contractor with out any extra cost.
Monthly inspection and service of the cooling tower. (a) Check cooling tower water being circulated for the suspended particals, algae formation, if find so refill the circuit with fresh water and cleaning of cooling tower for algae etc complete.
Periodical inspection and service of the plant Water cooled scroll Chillers ( 80 x 3 = 240 TR, VOLTAS) once in a quarter as detailed below : (a) Drain the water and clean the sump of cooling tower. (b) Clean pot stainer/ Y-stainer. (c) Check the condition of fills, if required, clean the fills with detergent. (d) Check for operation of shut off valves.
"Descaling of plant with descaling agent once in a year"
WATER COOLERS (SECTION-II)
Taking down water cooler of any capacity /make /size from site, transporting to work site and opening side covers of water cooler and disconnecting all components and controls and condenser fan motor, cleaning condenser with blower and washing with water and descaling with acid by spraying on both side of condenser. Cleaning with nylon brush and washing with clean water complete. Refixing condenser fan motor, making electrical connection of relay, over-load etc. Refixing side covers, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Taking down old unsv sealed compressor of Water Cooler of cap 40/80 ltrs of any make and S & F in replacement new sealed compressor of existing size, make and capacity ,connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and including charging of Refrigerant gas ,compressor oil, testing commissioning complete all as specified and directed by Engr-in-Charge.
All as per item No 3.02 here in before but water cooler of cap 60/120 ltrs.
All as per item No 3.02 here in before but water cooler of cap 150/180 ltrs.
Supply & fixing in replacement of starting capacitor 80-100 mfd complete all as specified and directed by Engr-in-Charge.
All as per item No 3.05 here in before but of cap 40-60 mfd.
All as per item No 3.05 here in before but of cap 60-80 mfd.
Supply & fixing in replacement of thermostat switch for water cooler complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of condenser fan motor 1/35 HP 250 Volts AC Single phase suitable for water cooler complete all as specified and directed by Engr-in-Charge.
All as per item No 3.09 here in before but of capacity 1/10 HP complete.
Supply & fixing in replacement of starting relay kit suitable for any make & capacity water cooler complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of condenser fan blade of following sizes suitable for water cooler of any make /capacity complete all as specified and directed by Engineer-in-Charge. (a) Fan motor 1/35 HP
All as per item No 3.12 here in before but Fan motor 1/10 HP
Supply & fixing in replacement push cock chromium plated 15 mm dia complete all as specified and directed.
M&L gas charging R-22 in water cooler of any capacity and make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of electric wiring kit suitable for water cooler of any make and capacity complete all as specified and as directed.
S&F in replacement of running capacitor 30.00 mfd complete all as specified and directed.
All as per item No 3.17 here in before but 25.00 mfd complete all as specified and directed.
All as per item No 3.17 here in before but 10.00 mfd complete all as specified and directed.
S&F in replacement of float valve assy complete suitable for water cooler of any size/cap non metallic body complete all as specified and directed.
Supply and fixing in replacement receptacle tray as per existing complete all as specified and directed.
Supply and fixing in replacement PVC wire three core copper multistranded and 40/0.0076, 1100 v grade complete all as specified and directed.
Supply and fixing in repair plug top 16 Amp, 3 pin AC complete all as specified and directed.
Supply and fixing in repair waste pipe 32 mm with complete fittings for water cooler of any make and capacity complete all as specified and directed.
M & L spray painting of outer surface of water cooler of any make of capacity 40/80 ltrs with two coats of deco paint of approved colour after preparation of surface including filling of cavities over existing paint complete all as specified and directed
REFRIGERATORS (SECTION-III)
Taking down old sealed unsv compressor of Refrigerator 165-185 ltrs capacity of any make and S & F in replacement new sealed compressor of same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including charging of refrigerant gas, testing commissioning complete all as directed by Engineer-in-Charge.
All as per item No 4.01 here in before but cap 190 To 220 ltrs .
All as per item No 4.01 here in before but cap 230 To 321 ltrs.
S & F in replacement of OS relay suitable for low/high speed refrigerator compressor of 165 to 321 ltrs refrigerator complete all as specified and directed.
S&F in replacement of thermostat suitable for upto 321 ltrs capacity refrigerator complete all as specified and directed.
S & F in replacement of refrigerator dryer made out of copper tube suitable for any cap Refrigerator complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Magnetic door gasket suitable for 165 to 185 ltrs refrigerator complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 4.07 here in before but for 230 to 321 ltrs refrigerator.
S&F in replacement of door handle for refrigerator of any make and capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of freezer with cooling coil for 165 to 220 ltrs refrigerator of any capacity complete all as specified and directed by Engr-in-Charge.
All as per item No 4.10 here in before but for 230 to 321 ltrs refrigerator complete all as specified and directed.
Note for Srl item No 4.06,4.10 & 4.11 :- Gas charging shall be measured and paid for separately.
S&F in replacement of freezer door suitable for 165 to 185 ltrs refrigerator of any capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 4.13 here in before but for 230 to 321 ltrs refrigerator.
S&F in replacement of chill tray suitable for refrigerator of any make and capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of ice tray suitable for refrigerator of any make and capacity complete all as specified and directed
S&F in replacement of lamp 15 watt screw / Pin type suitable for any make and capacity refrigerator complete all as specified and directed by Engineer-in-Charge.
M&L for charging of refrigerator gas A (134a) after vaccuming / pressure testing and leakage testing including flushing the system in the refrigerator of any make of 165-220 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No 4.18 here in before but 230 to 321 ltrs capacity.
S&F in replacement vegetable tray suitable for refrigerator of 165 to 220 ltrs capacity complete all as specified and directed.
All as per item No 4.20 here in before but capacity 230 to 321 ltrs capacity.
S&F in repair plug top 5 Amps 3 Pin complete all as specified and directed.
S&F in replacement of cable PVC insulated 3 core size 1.5 sqmm complete all as specified and directed.
DEEP FREEZER( SECTION-IV)
Taking down sealed unsv compressor of Deep freezer upto 320 ltrs capacity of any make and S&F in replacement new sealed compressor of same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and charging of refrigrant gas, testing commissioning complete all as directed by Engineer-in-Charge.
M&L gas charging Deep Freezer up to 320 ltrs capacity including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of OS relay suitable for Deep freezer unto cap 320 Ltrs complete all as specified and directed.
S&F in replacement of thermostat suitable for Deep freezer upto cap 320 Ltrs complete all as specified and directed.
S&F in replacement of fan motor suitable for Deep freezer upto cap 320 Ltrs complete all as specified and directed.
DESERT COOLERS ( SECTION-V)
S&F in replacement of desert cooler submersible pump, single phase, AC, 230 volt complete all as specified and directed.
S&F in replacement of desert cooler fan motor suitable for operation on 230 V single phase AC supply 3 speed 1400 RPM complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of electronic step type regulator capacity 300 watt complete all as specified and directed.
S&F in replacement of Grass pad/Khas pad for desert cooler of any size. (as per sample ordered) complete all as specified and directed.
S&F in replacement of cable PVC flexible 3 core size 23/0.0076 complete all as specified and directed.
S & F in replacement of capacitor 4.0 mfd complete all as specified and directed.
S & F in replacement of 3 Pin plug top 5 Amps complete all as specified and directed.
S & F in replacement of PVC Pipe 15 mm dia of superior quality complete all as specified and directed.
M&L for painting of desert cooler of any make /capacity with one coats of synthetic enamel paint of approved colour after the preparation of old painted surface complete all as specified and directed by Engineer-in-Charge.
M & L for rewinding of desert cooler fan motor 20 inch sweep with super enamelled copper winding wire and providing shellac varnish, testing commissioning complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC water distributor 3-way for desert cooler of superior quality complete all as specified and directed by Engineer-in-Charge.
S&F in repair Desert Cooler fan blade suitable for 18/20 inch sweep desert cooler motor complete all as specified and directed.
S&F in repair of commercial ply sheet 3 mm thick on windows complete all as specified and directed by Engineer-in-Charge.
VOLTAGE STABLIZER ( SECTION-VI)
Opening the cover of the automatic voltage stabilizer of any make and capacity, checking carefully, cleaning, servicing including tightening of loose connection /joints of all the controls components to make the voltage stabilizer in serviceable condition complete all as specified and directed by Engineer-in-Charge. (Note :- Any component /controls if replaced shall be measured & paid separately).
S&F in replacement of volt meter 0-300 volts, 2 ½” dia complete all as specified and directed.
S&F in replacement of new 2 way switch 5 Amps piano type complete all as specified and directed.
S&F in replacement of porcelain cut-out 5 Amps complete all as specified and directed.
All as per item No 7.04 here in before but 15 Amps complete all as specified and directed.
S&F in replacement of new main transformer for cap. 0.5 to 2.00 KVA voltage stabilizer completes all as specified and directed by Engineer-in-Charge.
All as per item No 7.06 here in before but 3.00 to 5.00 KVA.
S&F in replacement of electric wiring kit suitable for voltage Stabilizer of any make and capacity upto 5.00 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of relay 12/24 volts suitable for any make capacity 1.0 to 2.0 KVA voltage stabilizer complete all as specified and directed.
All as per item No 7.09 here in before but suitable for 3.0 to 5.0 KVA.
S&F in replacement of new electronic printed control card suitable for any make and capacity upto 5.0 KVA voltage stabilizer complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of new socket piano type 6 pin 15 Amps complete all as specified and directed.
All as per item No 7.13 here in before but 5 Pin 5 Amps.
S&F in replacement of indicating lamp, 230 volts complete all as specified and directed by Engineer-in-Charge.
Dighard Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .