Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 CrAccepted-AOC DOOR NO 5 155B KOTHARATHU BUILDING NEAR ALPHA PALIATIVE CARE VENGANELLUR CHEKKAKKARA THRISSUR KERALA 680586 | THRISSUR | KERALA | 680586 | ₹8.2 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹9.0 Cr+₹82.7 L (10.1%)Rejected-Finance KADAYIL DEW 1ST FLOOR DOOR NO 1888 NH ROAD SREEKARYAM PO TRIVANDRUM 695017 | THIRUVANANTHAPURAM | KERALA | 695017 | ₹9.0 Cr+₹82.7 L (10.1%) | L2 | Rejected-Finance Second Lowest |
Tender Value
₹9.6 Cr
EMD Value
₹19.1 L
Closing Date
16 Jan 2023, 5:00 pmClosed
Chief Engineer, Transmission (North)
O/o Chief Engineer, Transmission (North), Vydyuthi bhavanam, Kozhikode
Loss Reduction Transmission works under KASARGODE district - Reconductoring of 33 kV Mulleria - Badiyadkka Single circuit line from 110 kV Substation, Mulleria to 33 kV Substation, Badiyadkka using Covered conductor on Turn Key contract basis
2022_KSEB_535343_1
CE/TRN/AEE2/16/2022-23 dated 01.12.2022
Open Tender
Electrical Works
Turn-key
730 days
Ele circle, Kasargode under Kasargode district
As specified in Bid document
8 documents required · 8 mandatory
₹11,800
₹19.1 L
Yes
Vydyuthi bhavanam, Kozhikode
30 May 2023
6 Dec 2022
18 Jan 2023
6 Dec 2022
16 Jan 2023
7 Dec 2022
7 Dec 2022 - 15 Dec 2022
16 Dec 2022
Amount
Description of materials
33kV AAAC, 120 sqmm, Covered Conductor with water blocking component, stranded circular size (circuit length × 3% sag & maintenace× 3)
Supply of 33kV Grade, 120 sq mm Joining Kit ( Full Tension Mid- Span Joint along with Heat Shrinkable Type)
Polymeric surge arrestors 33 kV class, 10 kA, Class 1
Insulating piercing connectors for 120 sqmm cable branching/tracking Surge Arrestors
Supply of Heat shrinkable outdoor termination kit ( bolted /crimped lug type) (1 set = 3 Nos)
33 kV Class Polymeric Tension Insulator with special string hardware and accesories for 120 sq mm covered conductor
Pre formed plastic cable ties suitable to bind Covered conductor with Pin insulators
Special channel Crossarm
A type 14m pole for 33 kv line
Lattice B type 14m pole for 33 kv line
Lattice C type 14m pole for 33 kv line
33 kV Class Polymeric Pin Insulator
V cross arm for 33 kV line with clamp b&N
Stay insulator 33kV
Stay tightner HT
HT stay rod
HT Stay wire
GI wie 8 SWG 4mm
GI Earth pipe , 40mm dia 2.5Mtrs length
4 line cross arm (for strut and AB)
Bolt and Nut
Channel cross arm (3m)
ACSR Racoon
ACSR Rabbit
Description of Work / Item(s)
Amount
33 kV Reconductoring using Covered conductor
Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared
Transporting lattice tower parts and connected accessories including loading and unloading charges etc as directed by Board staff to an average distance of 5 Km by lorry.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge - All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge - Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge - Hard rock (blasting prohibited)
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials - All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials - Ordinary or hard rock
Stub setting in lines and levels using template in concrete foundation for 14 m A,B,C type lattice towers,etc as per specification and as directed by the departmental staff at site.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stoneaggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo - Mechanically Treated bars of grade Fe-500D or more
Erection of tower superstructures above the ground level including erection of normal and special hill side members, wherever necessary, providing insulators, cross arms tower accessories etc for 14 m A,B,C type lattice towers etc as per approved drawing and direction of the departmental staff at site.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Loading 14 m 'A' type pole from the stacking place and unloading the same at work site (transport by vehicle).
Transporting 14 m A poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading
Transporting 14 m A pole by headload
Fitting and erecting one 33kV 'A' type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing)
Additional rate for excavation of 33kV 'A' pole in hard laterite
Fitting and erecting one HT DP using 14 m 'A' type pole in position including fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
Fitting and providing one 33kV stay including digging & back filling pit.
Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite.
Fitting and providing one Fly stay for 33 kV pole using 14 m 'A' type pole including digging & back filling pits.
Fitting and providing one Strut using 14 m 'A' type pole including digging & back filling pit.
Providing one earthing using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling.
Additional rate for excavation of one Earth Pit (2.5m depth) in Laterite.
Fitting one Additional Channel cross arm (100x50x6mm), in existing A Pole/Lattice including conveyance of materials.
Fitting one set AB switch and giving connection
Drilling hole of various sizes on existing Channel/Cross Arm.
Cutting of GI channel, ISMBs, ISMC 100 GI angle as per specification including conveyence of materials and machinery to the site, etc. as per approved drawings and as directed by departmental staff at site.
Stringing of 33kV, 120sqmm AAAC Covered Conductor including fitting of all accessories, providing end terminations, midspan joints, installing insulated piercing connectors etc.(inclusive of 3 conductors of 3 phases and 3% for Sag and maintenance.
Dismantling 3 line ACSR DOG conductor including pin insulator string on the tower cross arm and pilot wire . Hire charges for tools, all hire and labour protection trestle and labour for providing suitable back stays at the time of dismantling etc complete.
Dismantling (without damage) one 11 kV 'A' type pole after disconnecting stays, strut etc. and stacking the same.
Dismantling (without damage) one No. 11 kV TW/RSJ/Rail pole after disconnecting stays, strut etc. and stacking the same.
Dismantling (without damage) one 11 kV PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Dismantling (without damage) one AB switch from existing structure and bringing back to section store
Dismantling (without damage) one HT PSC/RCC Strut pole including removal of clamps and stacking.
Dismantling (without damage) one HT stay incl. back filling, and bringing back to section store.
Dismantling one Channel cross arm from existing DP structure, and bringing back to section store.
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Dismantling (without damage) LT stay including digging pit in all classes of soil and backfilling
Dismantling (without damage) one km 11 kV line (3 conductors), cross arm, insulators, disc, rolling the conductor and stacking.
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Stringing of one km 11 kV line with ACSR Raccoon (3 conductors) including cutting and removing tree branches wherever necessary.
Stringing one km LT 3ph 4 wire line (Rabbit for Ph, Weasel for N) including fitting cross arm etc. removing touchings and conveyance of materials.
Providing Stay for LT poles including digging & back filling pit.
Dismantling and reconnecting Sph service connection from the OH line including lowering down the WP portion.
Dismantling and reconnecting 3ph service connection from the OH line including lowering down the WP portion.
Description of Work / Item(s)
Amount
Covered conductor - Spares
33kV AAAC, 120 sqmm, Covered Conductor with water blocking component, stranded circular size (circuit length × 3% sag & maintenace× 3)
Supply of 33kV Grade, 120 sq mm Joining Kit ( Full Tension Mid- Span Joint along with Heat Shrinkable Type)
Insulating piercing connectors for 120 sqmm cable branching/tracking Surge Arrestors
Supply of Heat shrinkable outdoor termination kit ( bolted /crimped lug type) (1 set = 3 Nos)
33 kV Class Polymeric Tension Insulator with special string hardware and accesories for 120 sq mm covered conductor
Description of Work / Item(s)
Total Amount excluding GST of BoQ1 (Plant and Equipment)
Total Amount excluding GST of BoQ2( Installation /Erection charges)
Total Amount excluding GST of BoQ3(Plant and Equipment Spares)
Total Amount excluding GST of BoQ1 +BoQ2 + BoQ3
Unconditional Discount Offered by the Bidder (if any) in Rs
Grand TOTAL (Sl.No.3-Sl.No.4)
Genisys Engineers and Contractors
Genisys Engineers and Contractors
Genisys Engineers and Contractors
Genisys Engineers and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .