Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹34.4 L+₹77,599 (2.30%)Rejected-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-AOC R | |
| 3 | L3₹34.5 L+₹85,169.50 (2.53%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC R | |
| 4 | L4₹35.2 L+₹1.5 L (4.54%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC R | |
| 5 | L5₹36.6 L+₹3.0 L (8.83%)Rejected-AOC | L5 | Rejected-AOC R |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Dec 2023, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION FITTING AND FIXTURES MD ACCN OF OFFICERS JCO OR AND CIV MD ACCN AT NORTH COMPLEX UNDER GE IMA DEHRADUN
2023_MES_628685_1
GE/IMA/T-63 of 2023-2024 9366/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹80,000
Yes
29 Dec 2023
17 Nov 2023
18 Dec 2023
18 Nov 2023
16 Dec 2023
2 Dec 2023
Amount
Material and labour for point wiring with PVC insulated and unsheathed electric able 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 Sq mm nominal cross sectional area drawn in and including concealed non metallic rigid PVC conduit not less than 25 mm dia with all fitting and fixing accessories and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6 mm thick, 60 mm deep of required size factory made for mounting switch, regulators etc with and including 3 mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following including taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, holders and making good the disturbed surfaces in cement 1:3 of walls, floors, ceiling by applying one coat of putty and two coat of distempering to match with existing surfaces. Make of wire: Anchor/SCI/Grandlay Make of conduit: AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab
One light point controlled by one, one way 6 Amp switch
One fan/exhaust fan point controlled by one, one way 6 Amp switch
One 5 pin 5/6 Amps socket outlet point on the same board .
One 5 pin 5/6 Amps socket outlet point on independent board.
One bell point controlled by one, one way 6 Amp button switch.
All as per item No 1 here-in-before but point wiring with 4 Sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 4 Sqmm PVC insulated multistranded copper conductor cable as continous earth wire.
All as per item No 1 here-in -Before but point wiring in casing caping /PVC Conduit as per site requirement complete all as specified and directed by Engr-In- Charge for the following :-
One light point controlled by one, one way 6 Amp switch
One fan/exhaust fan point controlled by one, one way 6 Amp switch
One 5 pin 5/6 Amps socket outlet point on the same board
One 5 pin 5/6 Amps socket outlet point on independent board
One bell point controlled by one, one way 6 Amp button switch.
All as per item No 1 here in before but point wiring casing caping /PVC Conduit as per site requirement with 2.5 Sq mm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 Sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
All as per item No 1 here-in -before but modular point wiring with in and including concealed non metallic rigid PVC conduit not less than 25 mm dia including modular inner and outer frame plate matching with surrounding with modular sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets,regulator etc complete for the following :- Note for item No :1,2,3,4,5 (i) The quoted rates shall be deemed to be inclusive for cutting chasing in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing by applying one coat of putty and two coat of Distemper to the surface to match with the existing surface.The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) 1 x 5 Amps Independent board in one circuit of 1.5 sqmm and 1 x 16 Amps Socket board in one circuit of 2.5 sqmm / 4 sqmm be made. (iv) Wiring insulation test result sheet after or before carryng out the internal wiring must be recorded by contractor and the rate for the same deemed to be inclusive in the quoted rate. (v) Inventory of accn for wiring and fitting and fixture shall be prepared by contractor and submited to the dept after completion of wiring work for check and record and the rate for the same deemed to be inclusive in the quoted rate.
One light point controlled by one, one way 6 Amp modular switch.
One fan/exhaust fan point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on the same board
One 5 pin 5/6 Amps socket outlet point on independent board
One bell point controlled by one, one way 6 Amp modular switch.
All as per item No.5 here-in-before but point wiring with 2.5 Sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 Sq mm PVC insulated multistranded copper conductor cable as continous earth wire.
S & F switch piano, flush type, single pole one way, 5/10Amp complete all as directed. Make : Anchor Penta PC, Havells (Reo)/SSK
S & F switch piano, flush type, single pole one way, 15/20 Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S & F socket outlet, multipurpose, 2 in 1 5 pin, 5/10 Amp complete all as directed. Make:Anchor Penta PC, Havells (Reo)/SSK
S & F socket outlet, multipurpose, 2-in-1 5 pin, 15 /20Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S & F for Electronic step type fan regulator 100 watt 230 volts AC 50 Hz complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S & F Bell AC 230 volts single pole complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S & F Bell push flush type, 5 Amps complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S & F Modular switch single pole one way 6 Amp fixed complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F for Modular switch single pole one way 16 Amp complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F Modular socket outlet 2/3 pin combined 6 Amp 240 volts fixed complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F Modular bell push flush type, 5 Amps complete all as directed. Make: Anchor, Legrand, Crabtree (Havells)
S & F fan regulator modular step type 120W 240 volts 2 module type complete all as directed. Make: Anchor, Bajaj, Crompton, Havells
S&F ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F Batten holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S & F sub main wiring with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including one run PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking sown old unsv submain wiring of following sizes complete all as specified and directed. Make of wire: Anchor/SCI/Grandlay Make of conduit: AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab Note:Two/Four run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. (iii) Phase sequence colour code must be follow i.e Phase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral.
2 x 10 Sqmm + 1 x 10 sqmm
2 x 6 Sqmm + 1 x 6 sqmm
2 x 4Sqmm + 1 x 4 sqmm
2 x 2.5Sqmm + 1 x 2.5 sqmm
2 x 1.5 Sqmm+ 1 x 1.5 sqmm
S & F in repairs 4 way Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt flush to wall including 01 Nos 160 Amps MCCB FP as incomer and 12/24 SP MCBs or 4 / 8 TP MCBs per per site requirement (or any combination of SP/TP MCBs) outgoings of following capacity including taking down old unsv MCCB DB,s complete all as directed. Make : Havells, Indo Asian, HPL
S & F in repairs MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 18 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations of following capacity complete all as directed. Make : Havells, Indo Asian, HPL
S & F in repairs MCB SP complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed of follwing capacity . Make : Havells, Indo Asian, HPL
MCB SP6 to 32 Amp.240 volts
MCB SP 40 to 63 AMPS 240 volts
MCB SPN 6 to 32 Amps 240 volts
MCB SPN 40 to 63 Amps 240 volts
S and F in repairs single pole and neutral enclosure with a two pin and earth, plug and socket complete with one single pole MCB 20 Amps all as specified and directed Make : Havells, Indo Asian, HPL
S & F in repairs MCB DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door Including 01 x 40 to 63 A SPN MCB as incoming and MCB SP 6 to 32A as out gooning as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity . Make : Havells, Indo Asian, HPL
4 way SPN DB.
8 way SPN DB.
12way SPN DB
16 way SPN DB
S& F modular fitting /fixture in repairs of following specification : Make: Anchor/Havells(Crabtree)/Legrand
Fan regulator modular step type 120W 240 volts 2 module.
Modular switch single pole one way 6/10 Amp 240 volts.
Modular switch single pole one way16/ 20 Amp 240 volts .
Modular socket outlet 2/3 pin combined 6/10 Amp 240 volts.
Modular socket outlet 2/3 pin combined 16/ 20 Amp 240 volts.
Modular bell push flush type, 6 Amps240Volts.
S&F in repairs white modular cover plate with frame of following module complete with frame all as directed. Make: Anchor/Havells(Crabtree)/Legrand
1Module
2Module
3Module
4Module
6Module
8 Module
12 Module
S&F in repairs modular metal flush box of following module complete all as directed. Make: Anchor/Havells(Crabtree)/Legrand
1Module
2Module
3Module
4Module
6Module
8 Module
12 Module
S&F in repairs Bell push flush type, 5 Amps complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs Bell AC 230 volts single pole complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs Electronic steppped socket type fan regulator 100 watt 230 volts AC 50 Hz complete all as directed. Make:Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs Batten holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs switch piano, flush type, single pole one way 6 Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs switch piano, flush type, single pole one way 16Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs socket out let, multipurpose, 2 in 1 5 pin, 6 Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo)/SSK
S&F in repairs socket out let, multipurpose, 2 in 1 5 pin, 16 Amp with fuse and neon indicator complete all as directed. Make:Anchor Penta PC, Havells (Reo)/SSK
S &F in repairs Bakelite sheet cover 3 mm thick cut as required shape and size including brass screws and cup washer off following size for mounting swich, socket fan regulator etc complete all as directed. Make: Hylam, Woodlite
Supply and fix in repairs Exhaust fan 300 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc complete all as specified and directed. Make : Orient/Crompton /Bajaj
S & F in repairs pressed steel sunken terminal boxes 1.6 mm thick, 60 mm including brass screws and cup washer of following size for mounting switch, socket fan regulator etc complete all as directed:-
Material and labour for Earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in cement mortar 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. Note: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted.
Supply and fix in repairs Rigid non metalic PVC conduit of , inclusive of boxes (junction/terminal)but inclusive of all tees,bend ,elbow reducers, bell mouth tube ends and fixing acessories such as couplers,lock,nut saddles,pipe hooks including taking down old unsv pvc conduit all as specified and directed. Make of conduit:AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab
40mm dia
32mm dia
25mm dia
20mm dia
Supply and fix in repairs PVC rectangular block white in colour for mounting Switch,Socket,fan regulator etc. with 3mm thick plastic laminated sheet cover of size all as directed.
100mmx100mm and 50mm deep
175mmx100mm and 50mm deep
Supply and fix in repairs PVC Casing Caping inclusive of all tees,bend ,elbow and fixing acessories including all as specified and directed:- Make of Casing Caping : AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab
50X20 mm dia
38 X 20mm dia
32X 16 mm dia
25 X 16 mm dia
S & F in repairs energy saving LED Bulb 14 W, E-27 base,220v- 240v ,50 HZ,including taking down old unsv led bulb all as specified and directed.
S & F in repairs three Phase electronic meter temper proof LCD display with polycarbonted cover 415 volt ,10 A to 60 Amps ,accuracy class-I, 50 Hz ,confirming to IS 13779,IP-54 with parameter to show data time ,current reading ,load PF ,voltage and KWH complete all as directed. Make: HPL, L&T, Secure.
Supply and fix in repairs Exhaust fan 250 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc complete all as specified and directed. Make : BAJAJ/Orient/CROMPTON
S & F in repairs wall mounted Fan 400mm sweep ,2100 RPM high speed and 105CMM Air Delivery,strudy base and thermal overload protection ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, etc including taking down old unsv wall mounted fan complete all as specified and directed. Make : Make : BAJAJ/Orient/CROMPTON
Supply and Fix in repairs LED batten light fitting 4 feet of lumens 2500 lumens, wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 125L/W ,polycarbonated diffuser,IP-20 ,high bright LED lamp, colour temp not less than 5700 Cool Day Light,colour rending index not less than 80 ,life not less than 20000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 10 % with operating voltage 140-270V AC, 50 Hz, surge protection minimum 2.5KV including,connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed . Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED batten light fitting 2 feet of 1000 lumens wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 100L/W,polycarbonated diffuser, IP-20 ,high bright LED lamp, colour temp not less than 5700 COOL DAY Light,colour rending index not less than 80 ,life not less than 20000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz, surge protection minimum 2KV including connected the same with using PVC sheathed, insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv Tube light fitting complete all as specified and directed . Make: - Philips(Ecolink)/Havells/Bajaj
Supply and fix in repairs LED Suspended Batten light fitting 4 feet of lumens 4000 lumens wall /Surface mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 100 L/W ,polycarbonated diffuser, IP-20 ,high bright LED lamp, colour temp not less than 6500 COOL DAY Light,colour rending index not less than 80 ,life not less than 35000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270V AC, 50 Hz, surge protection minimum 4 KV including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED Up Down twin glow 20W + 20W light fitting of lumens 2000 lumens wall mounted ,high pressure die cast alluminium, fully diffused ,polycarbonated diffuser,system efficacy 100L/W , IP-20 ,high bright LED lamp, colour temp not less than down 6500/ up 3000 Cool Day Light/warm light ,colour rending index not less than 80 ,life not less than 35000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 160-360V AC, 50 Hz, surge protection minimum 2.5 KV, including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED 1 x 1 feet Surface/recess mounted light fitting of lumens 1800 lumens ,CRCA housing, fully diffused ,polycarbonated diffuser, ,system efficacy 100L/W , IP-20 ,high bright LED lamp, colour temp not less than down 6500 Cool Day Ligh,colour rending index not less than 80 ,life not less than 25000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 2 KVincluding connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable, including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv Tube light fitting complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED street/Security wall mounted light fitting of lumens 2550 lm ,Single Piece High pressure die cast aluminium,system efficacy 110L/W,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish, fully diffused ,Polycarbonated Cover for More protection ,inbuilt electronic driver IP 66 ,High bright LED with Lens, colour temp Not less than 5700 Cool Day Light,colour rending index not less than 70 ,life not less than 50000 hrs,inbuilt electronic driver with 325V Auto Cut off Restart feature & 440V Phase to Phase protection till 8 hour, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz ,surge protection minimum 4 KV, including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED 2 x2 feet Surface/recess mounted light fitting of lumens 3600 lumens ,CRCA housing,Polycarbonated Cover for More protection , fully diffused ,system efficacy 100L/W,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish., IP-20 and IK-20,high bright LED lamp, colour temp not less than down 6500 Cool Day Ligh,colour rending index not less than 80 ,life not less than 25000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 2 KV, including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repair LED Round/Square ,Surface /Recess mounted light fitting of lumens 1800 lumens ,Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt Polycarbonated Cover for More protection , fully diffused ,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish.,high bright LED lamp, colour temp not less than down 6500 Cool Day Light,colour rending index not less than 80 ,life not less than 25000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 2.5 KV including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv light fitting complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix LED in repairs Round/Square ,Surface /Recess mounted light fitting of lumens 1500 lumens, Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt Polycarbonated Cover for More protection , fully diffused ,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish.,high bright LED lamp, colour temp not less than down 6500 Cool Day Light,colour rending index not less than 80 ,life not less than 25000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 2.5 KV including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED bulk head fitting wall mounted fitting of lumens 1000 lumens ,Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt Polycarbonated Cover for More protection , fully diffused ,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish, IP-66 and IK-08,high bright LED lamp, colour temp not less than 6500 Cool Day Light,colour rending index not less than 80 ,life not less than 50000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 2.5 KV including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED flood light fitting wall mounted fitting of lumens 5000 lumens ,Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt ,Toughened Glass Cover for More protection , fully diffused ,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish, IP-66 and IK-07,high bright LED lamp, colour temp not less than 6500 Cool Day Light,colour rending index not less than 70 <5 ,life not less than50000 hrs a 45 , inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 4 KV including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose light fitting complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED flood light fitting of lumens 13200 lumens ,Single Piece body Die cast lluminium ,System efficacy 110 Lm/Watt ,Toughened Glass Cover for More protection , diffused/Lens ,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. ,IP-66 and IK-07,high bright LED lamp, colour temp not less than 6500 Cool Day Light,colour rending index not less than 70 <5 ,life not less than 50000 hrs, Outcutt off @325V, 440V phase 2 phase protection, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz., surge protection minimum 4KV and 10 KV extended SPD, including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and Fix in repairs LED Post Top fittings of lumens 4000 lumens ,Single Piece body high pressure Die cast Alluminium ,System efficacy 100 Lm/Watt ,polycarbonated Cover for More protection ,Polycarbonate Diffuser,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish, IP-66 and IK-10,high bright LED lamp, colour temp not less than 5700 Cool Day Light,colour rending index not less than 70 <5 ,life not less than 20000 hrs, inbuilt electronic driver with 325V Auto Cutoff , 440V phase 2 phase protection, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz., surge protection minimum 2.5KV , including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and fix in repairs LED inverter bulb 9 watt retrofit type works on AC Normal mode and DC supply in inverter mode with inbuilt battery back up of up to 4 hours, high efficiency high lumens output ,including taking down old unsv led bulb complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and fix in repairs exhaust fan ,steel body AC single Phase 230 Volts of size 300 mm sweep with blades and frames and louvers complete all as specified. Make : BAJAJ/Orient/CROMPTON
S& F in repairs metal finished bed side lamp grey in colour 20 Watt /50 Lumens/3000K, base of the lamp should be E27 and dimension of fitting 470x67x28 mmand connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to wall complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
Supply and fix Metal finish wall light with maximum bulb wattage 12 watt, base of the lamp should be E27, colour of the fixture is white & silver wsith chrome finish and having rectanguar shape for aesthetic look. dimension of the fixture should be 100 x 125 x 200 mm and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to wall including taking down existing fitting complete all as specified and directed. Make: - Philips(Ecolink)/ Havells/Bajaj
Supply and fix Metal finish wall light with maximum bulb wattage 12 watt, base of the lamp should be E27, colour of the fixture is white & silver wsith chrome finish and having rectanguar shape for aesthetic look. dimension of the fixture should be 125 x 150 x 240 mm and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to wall including taking down existing fitting complete all as specified and directed. Make: - Philips(Ecolink)/Havells/Bajaj
S & F in repairs MCB TPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 63A to 100A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable including connection with suitable size copper lugs complete all as directed of following capacity :- Make : Havells, Indo Asian, HPL
MCB TPN 63 Amps, 415 volts
MCB TPN 100 Amps, 415 volts
M &L for preventive maint of Accn by checking loos connection by opening MCCB DB, MCB DB,Switch board,Sheet metal Enclosure and refresh all connection of switch board,MCB DBs tightining the MCB,s and and refix the same position all as specified and directed.
Taking down carefully existing surface /conceled light fitting from any height of any wattage /description by disconnecting the wire and set aside insafe custody for reuse and refixing in same postion after completion of work all as specified and directed.
Supply and fix in repairs Aluminum strip 25mm x 3 mm with porceilain saddles & fixing screw etc for roof conductors and down conductors above gorund level including taking down old unsv strip of any description . Note : (i) Aluminium strip shall not be fixed in direct contact to wall & shall be provided all as specified and directed (ii) Rate for Scafolding required to fix strip on the roof of gymnesium building shall demed to be inclusive in quoted rate.
Supply and fix in repairs Air termination , single pointed aluninium rod 12 mm dia ,300mm long fixed to angle iron 40mmX40mmX 6mm with flat iron clamp made of 25mm X3mm channel and embedded in PCC block of size 200mm X200mm X300mm including taking down old unsv air termination rod of any description all as specified and directed. Note: In case of Temporary Buildings where roofs are of Steel Sheet, GI strip needs to be fixed GI strip .
A ONE BUILDERS AND ENGINEERS
Deven Associates
Bedi Refrigeration Works
Balraj and Co
JS CONSTRUCTION COMPANY
M/s Anamika Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .