Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.6 CrAccepted-AOC | ₹7.6 Cr Quoted ₹7.9 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹8.1 Cr+₹25.5 L (3.24%)Rejected-Finance | ₹8.1 Cr+₹25.5 L (3.24%) | 2 | Rejected-Finance L2 |
Tender Value
₹6.4 Cr
EMD Value
₹6.4 L
Closing Date
3 Feb 2022, 5:00 pmClosed
Executive Engineer
JSV Division Kullu
Site development of pump house, C O RCC sump well cum storage tank, sector storage tanks at various locations, C O 3 Nos pump house and boundary wall for pump houses Stage-1,2and 3, wire crate protection, laying jointing testing of GMS pipe for tank
2022_HPIPH_55897_1
20136-235
Open Tender
Civil Works
Item Rate
Kullu
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,500
EE
₹6.4 L
Yes
11 May 2022
19 Jan 2022
4 Feb 2022
20 Jan 2022
3 Feb 2022
20 Jan 2022
Amount
Cutting in earth work and disposal of all excavated earth work upto lead of 20 metres in pick work , jumper work in leads and lifts as per the direction of Engineer-in-Charge.
Excavation in foundation and trenches up to all depths and in all classification of earth work such as pick work, jumper work, situated soil including bailing or pumping out water, blasting soft/ hard rock, chiseling /wedging of soft / hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking, timbering and dewatering wherever required. Stacking usable and unusable material /soil separately and after laying jointing and testing of pipes, returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed with in all leads/ lifts including restoration of un-metalled surfaces to its original conditions and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. Complete in all respects within all leads and lifts as per direction of the Engineer-in-Charge.
Stone/Boulders filling behind the R/walls, also under floor etc. in all lifts & leads complete in all respect
Wire Crates mate of G.I. wire filled with boulders with square cot face against the wire ( Boulder filling to be measured and paid separattely) GI wire 5mm thick corresponding to SWG-6(15cmx15cm Mesh) within all leads and lifts and as directed by the Engineer-in-Charge
Wire crates mate of G.I. wire filled with boulders with square cot face against the wire ( Wire crate to be measured and paid for separattely) within all leads and lifts and as directed by the Engineer-in-Charge
Providing and laying Cement concrete 1:3:6 ( 1 cement, 3 sand , 6 graded stone agg. 40 mm nominal size ) excluding cost of centring shuttering in plinth and foundation including curring complete as per direction and entire satisafaction of Engineer in Charge.
Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size )and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge.
Providing and laying cement concrete 1:6:12 (1cement: 6 sand: 12 graded crushed stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts .
Random rubble masonry/polygonal rubble masonry (uncoursed/brought to courses) with hard stones of approved quality in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level in Cement Mortar 1:6(1 cement:6 sand)
Providing and laying cement concrete work 1:1.5:3 (1cement :1.5 sand: 3 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in: - Foundation and plinth
Wall ( any thickness but not less than 0.10 mtrs. Thickness) including attached pillasters buttresses, plinth and string courses etc. from top of foundation level upto floor two level.
In suspended floor roofs landing shelves & their support balconies, beams, girders bressumers cantilevers upto floor two level with in all leads and lifts.
Column,pillars post and struts upto floor two level
Arches upto floor Two Level
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded crushed stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. in:-Foundation and plinth
In suspended floor roofs landing shelves & their support balconies, beams, girders bressumers cantilevers upto floor two level with in all leads and lifts.
In Column
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1cement:3Sand)
Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level i.c cost of binding wire with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and fifts:- Foundation, footings basis of columns etc. and mass concrete.
Columns, pillars, posts and struts up to floor two level (Square rectangular polygonal in plain)
Vertical surfaces such as wall(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like -
Flat surfaces such as soffits of suspended floors roofs landings and the like floors etc. up to 200 mm in thickness with in all leads and lifts.
Beam cantiliver girders and lintels Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floor.
Edges of slab and breaks in floors and walls under 20 cm wide with in all leads and lifts..
Sloped and battering surfaces
Providing form work of ordinary timber planking so as to give rough finish i/c centering, shuttering, strutting & propping etc. height of propping & centering below supporting floor to ceiling below supporting floor to ceiling not exceeding 4 mtrs & removal of the same for insitu-reinforced concrete & plain concrete in :- Arches beyond 6 mtrs span
Providing and fixing MS man hole cover of size 600 x 600 mm made up of 3.15 mm thick plain MS sheet fixed in angle iron frame frame of 50x50x5mm supported with MS flat of 50x5mm at center of sheet including fising hold fast ,hinges and locking arrangement and lock of medium size etc complete in all respects as per the direction of Engineer-in-Charge.
Providing and fixing MS man hole cover with frame having frame size 560 mm internal Dia (medium duty ) The weight of cover & frame should not be less than 100 kg with Locking arrangement etc complete in all respects as per the direction of Engineer-in-Charge.
Providing and fixing CI sluice valve (With hand wheel) as per IS 780-1984 class-I upto 300 mm dia (i/c brass spindle & as per 2906-1984 class-II for dia <300mm) complete in all leads and lifts as per the direction of Engineer-in-Charge. 150 mm
Providing wood work in frames of doors, windows, clerestory windows and other frames wrouhgt, frramed and fixed in position in 2nd class Deodar wood within all leads and lifts as per direction & satisfaction of Engineer-in-charge.
Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright finished black enammeled iron hinges with necessary screws: 2nd class deodar wood 40mm thick including entire carriage of material as per satisfaction of Engineer-in-charge.
Providing and fixing wire gauge shutters using galvanised M.S.wire gauge of I.S gauge designation 85 G with wire of dia 0.56mm for doors windows and clerestory windowsincluding bright finished black enamelled iron hinges with necessary screws 40mm thick Ist class deodar wood.
15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand) with in all leads and lifts
6mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) complete within all leads and lifts.
Cement pointing on brick work with cement mortar 1:4 (1cement:4sand) complete within all leads and lifts.
Providing and fixing M.S. grills of required pattern in MS frames of windows etc with MS flat welded with wire mash. complete within all leads and lifts.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade including thoroughly brooming the surface to remove all dust dirt & other foreign matter with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
Distempering (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on undecoratedwall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortor droppings and other foreign matter and also including preparing the surface even and sand papered smooth .priming coat with distemper primer details of cost for 10 Sqm.
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink with in all leads and lifts.
Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with readymade paint other than white with in all leads and lifts..
Supplying and fixing rolling shutter of approved make made of 80mmx1.25 mm M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with bracket side guides and arrangement for inside and outside locking with push pull operation complete but excluding the cost of the top cover and spring shutter having width below 3.5 meters within all leads and lifts.
Providing and fixing aluminium tower bolts(barrel type)anodized transparent or dyed to required shade and colour with screws etc.complete. 250 mm x 10 mm
150 mm x 10 mm
Providing and fixing aluminium handles anodized transparent or dyed to required colour or shade with necessary screws etc. complete with in all leads and lifts 125 mm
Providing and fixing anodized alumnium sliding door bolt anodized transparent or dyed torequired colour and shade with bolts and nuts and screw complete with in all leads and lift 250x16mm
Providing Stone soling properly hand packed under floor with in all leads and lifts
40mm thick cement concrete flooring 1:2:4(1cement 2sand 4 graded stone agg.20mm nominal size ) laid in a single layer finished with a floating coat of neat cement within all leads and lifts.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand: 6 graded stone aggregate 20mm nominal size). with in all leads and lifts
Providing under layer of plinth protection of 75mm thick uncosolidating bed dry brick/ stone aggregate 40 mm nominal size with rammed and consolidated and grouted with fine sand including prepartion of ground.
Providing 40x3mm flat iron hold fast 40cm long i.e fixing to from with 10mm dia bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm 1:3:6 ( 1cement 3 sand 6 graded stone agg. 40mm nominal size)
Brick work using common burnt clay building bricks in super structure above plinth level upto floor two level 2nd class bricks cement mortar 1:6(1cement:6sand) with in all leads and lifts.
Supplying , erection and installation of Elephant brand 2.0 Ton Capacity Electrically Operated Chain Electric Hoist having 5.0 Mtrs. Lift Chain Hoist conforming to I.S. 6547, Class of Duty: II with Electrically Operated Travelling Trolley Head Room 300 mm including all fittings Girders ISMB etc in all leads and lifts as per the direction of Engineer-in-Charge.
Half brick masonary in common burnt clay buildings bricks in cement mortar 1:4(1cement:4sand) 2nd class bricks with in all leads and lifts.
Providing ,supplying and fixing brick bat for soak pit with in all leads and lifts.
Providing and fixing Cera/Hindware make double symphonic “P” or “S” trap WC pan (two piece ) complete in all respect. With built in cistern 10 litr capacity of required shade (CRUSE 2018) WC-1with in all leads and lifts
Providing and fixing Cera/Hindware make double symphonic “P” or “S” trap WC pan (indian type ) complete in all respect. WC-2 with in all leads and lifts
Providing and fixing 10 litr vitreous china high level flushing cistern of Hindware/ Cera make with in all leads and lifts
Providing and fixing plastic seat cover solid type ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing vitreous china 55x40cm flat back wash basin ( White colour) with MS brackets duly painted (cornet-1008 of Cera/Hindware make.)with in all leads and lifts
Providing and fixing PVC waste pipe 32mm nominal dia for wash basin and sink ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing M.I. Union for wash basin or sink with in all leads and lifts
Providing and fixing 450x600mm bevelled edge mirror of reputed make mounted on AC sheet and fixed with brass screws with in all leads and lifts.
Providing chromium plated brass soap dish with brass bracket of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing 15mm angle valve ISI (Heavy duty) ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing PVC connection 15mm of superior quality within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing 100mm dia CP grating for floor traps of superior quality within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing & fixing CP 15mm dia short body bib tap ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing spray flushing jet ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.
Providing and fixing GMS tube (heavy class) ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge.including GI fitting of following dia:- 15mm dia
Providing and fixing PVC pipe ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge. 100 mm dia
75 mm dia
Providing and fixing PVC door bend ISI mark of reputed make within all leads and lifts and to entire satisfaction of Engineer-in-charge. Door bend
Plain Bend 100 mm
Plain Bend 75 mm
Providing and fixing PVC water tank 500 ltr capacity all leads and lifts and to entire satisfaction of Engineer-in-charge.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed Steel / PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable including dismantling of the existing wiring as required. ( including switch & bakelite sheet etc.)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. 2x1.5 Sq.mm
2x4.0 Sq.mm
2x6.0 Sq.mm
Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. S.P. 15/16 Amps one way switch, porcelain base/ piano type.
S.P. 15/16 Amps socket outlet, porcelain base/ piano type.
Bell push, piano type.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/ recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/ recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Double pole. Cat-A.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole. Cat-A. (Mr. Rate)
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-12 way
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way, 5/6 amps piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group A.
Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- i) Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Steel work i/c cutting, hoisting & fixing in position & applying a priming coat of red oxide paint in grating,frames, girder, bar , ledder , railing , brackets and similar works
Steel work in single section including cutting hoistig R.S. Joints channel angles iron 50x50x6mm thick angle iron for posts.
1.80 mtrs high fencing with 2.50 mtrs. M.S. angle iron of size 40x40x6mm minimum 2.50 mtrs. center to center with nine horizontal lines and two diagonal of galvanised steel barbed wire (IS-278-1962 type-1) weight of 9.38 Kg./100 mtrs.(minimum) storical and fixed to post complete cost of posts structs and straining bolts shal be paid for separately
Providing and fixing compound gate of size 1350x900mm fixing in IMAC channel of 75x75mm (1.96m over all) with hinges including gate made of angle iron 40x40x6mm for horizontal and vertical strips respectively welded within all respect including old strips size 300x16mm eith necessary accessories complete in all respect including fixing the gate with hold fast and MS plate 10x10x6mm.
Manufactuting ,supplying and fixing of fencing penal of size 1.20mx1.80m of Jali 25x25mm mesh welded to M.S black tube 32mm dia 14 gauge with M.S flat cover 20x3mm, M.S hold fast 7 nos made out of M.S flat 32x5 mm including cutting welding painting with red oxide paint complete in all respect as per direction of Engineer -in - Charge
Laying,jointing with Butt welding and testing to levelled grades, IS marked Galvanised Mild steel Tube of following dia mtr. specifications confirming IS:1239 ( with upto date amendments )having wall thickness as per IS code in rendom length of 4 to 7 mtrs,including carriage of material up to site ,flushing , cleaning and hydraulic testing complete in all respect as per the satisfaction of Engineer in charge. ( Earth work to be measured & paid for separately) Booster Stage 1 :- 100 mm dia (MC) ( 4.5 mm thickness)
Booster Stage 2:- 100 mm dia (MC) ( 4.5 mm thickness)
1st Stage :- 150 mm dia (HC) ( 5.4 mm thick)
150 mm dia (MC) ( 4.8 mm thick)
2nd Stage:- 150 mm dia (MC) ( 4.8 mm thick)
3rd Stage:- 80 mm dia (MC)
Laying,jointing and testing to levelled grades, IS marked Galvanised Mild steel Tube beveled ended of following dia mtr. specifications confirming IS:1239 ( with upto date amendments )having wall thickness as per IS code with bevelled/plain ends in rendom length of 4 to 7 mtrs, including manufacturing reducers/ tapers, all short pieces, bends, Tee etc from parental tube, providing and welding of MS flenges detailed below. The MS flange shall confime to BIS 6392-1971 ( with latest up to date amendments) duly welded in two layers ( Two inner and Two outer) with pipes at both ends as per relevent BIS standards along with nut, bolt of required size and 3mm thick compressed asbestos fiber?synthetic rubber gaskets confirming to relevant BIS standards . The bends be manufactured in three cut joints.The class of pipe as specified below including carriage of material up to site ,flushing , cleaning and hydraulic testing complete in all respect as per the satisfaction of Engineer in charge.The damaged portion of galvanization due to welding shall be provided with anticorrosive treatment by applying two coats of bituminous paint over priming coat as per AWWA specification C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. ( Earth work to be measured & paid for separately) Booster Stage 1 :- 100 mm dia (MC) with Flange Table 17
100 mm dia (MC) with Flange Table 5
Booster Stage 2:- 100 mm dia (MC) with Flange Table 17
100 mm dia (MC) with Flange Table 5
1st Stage:- 150 mm dia (HC) with Flange Table 28 ( 5.4 mm thick)
150 mm dia (MC) with Flange Table 28 (4.8 mm thickness)
2nd Stage:- 150 mm dia (MC) with Flange Table 28 ( 4.8 mm thickness)
3rd Stage:- 80 mm dia (MC) with Flange Table 28 ( 4 mm thickness)
80 mm dia (MC) with Flange Table 17 ( 4 mm thickness)
80 mm dia (MC) with Flange Table 5 ( 4 mm thickness)
Providing Butt welding, laying and testing to levelled grades, IS marked Galvanised MSERW Pipes beveled ended of following dia mtr. / specifications confirming ISO:3183 ( with upto date amendments ) of steel grades given below, jointing the pipes with butt welding at both and according to relevant BIS standards / approved specifications including manufacturing reducers/ tapers all short pieces , and bends as per site requirements and made from parent tubes ( to be measured and paid along with pipes ). Bends shall be manufactured in such a way that not more than 11-1/4 degree deflection is caused by a single cut and internal dia is not reduced including hydraulic testing to the entire satisfaction of Engineer-in -charge. The pipes and specials shall have in factory galvanized coating as per IS :4739 ( with latest amendments ) . The damaged portion of galvanization due to welding shall be provided with anticorrosive treatment by applying two coats of bituminous paint over priming coat as per AWWA specification C-203-1978 ( Earth work to be measured & paid for separately) 1st Stage:- MSERW Pipe L-360 X-52 150 mm dia. 6.4 mm thickness
MSERW Pipe L-360 X-52 150 mm dia.5.2 mm thickness
MSERW Pipe L-360 X-52 150 mm dia.4.4 mm thickness
2nd Stage:- MSERW Pipe L-360 X-52 150 mm dia.4.8 mm thickness
Providing , laying, fixing, jointing and testing in trenches MSERW pipe (ISO:3183) of following dia meters confirming steel grade given below (latest with upto date amendments) steel grade- A having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). 1st Stage:- MSERW Pipe L-360 X-52 150 mm dia. 6.4 mm thickness with Flange Table 38
MSERW Pipe L-360 X-52 150 mm dia. 5.2 mm thickness with Flange Table 34
MSERW Pipe L-360 X-52 150 mm dia. 4.4 mm thickness with Flange Table 34
2nd Stage:- MSERW Pipe L-360 X-52 150 mm dia. 4.8 mm thickness with Flange Table 34
MSERW Pipe L-360 X-52 150 mm dia. 4.8 mm thickness with Flange Table 28
Laying,jointing and testing to levelled grades, IS marked Screwed and socketed Galvanised Mild steel Tube of following dia mtr. specifications confirming IS:1239 ( with upto date amendments )having wall thickness as per IS code in rendom length of 4 to 7 mtrs, including all fitting the unions must be provided as per relavant code for laying of pipe, The class of pipe as specified below including carriage of material up to site ,flushing , cleaning and hydraulic testing complete in all respect as per the satisfaction of Engineer in charge. ( Earth work to be measured & paid for separately) GMS Tube 25 mm dia. Light Class Distribution Network
GMS Tube 32 mm dia. Light Class Distribution Network
GMS Tube 40 mm dia. Light Class Distribution Network
GMS Tube 50 mm dia. Light Class Distribution Network
GMS Tube 65 mm dia. Light Class Distribution Network
GMS Tube 80 mm dia. Light Class Distribution Network
GMS Tube 150 mm dia. Medium Class 4.85 mm thick Distribution Network
Booster Stage - 1 Providing suitable Clear water submersible pumpset type KRT capable of handling 50 PPM turbidity of KSB / Kirloskar / CALAMA/Johnston / Oswal/BS and other approved make conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible sq cage motor shaft conf to BIS 9238-1979 with up to date amendments of 1450 (N) RPM, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear,It should be fitted with device to take up expanion of water on heating of motor & suitable for operation on 415 +/- 10% volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- Discharge (Q) 5.96 LPS for each pump Total Dynamic head:- 83.73 meter a) LWL in sump well (h) 1070.00 meter b) Shaft level 1067.00 meter c) Level at discharge point 1140.00 meter d) Suction lift -ve meter e) Dynamic head 83.73 meter f) Static head 73.00 meter Rising main:- a) Length 360.00 meter b) Dia 100.00 mm Pumping hours 12.00 hours Altitude of installation above MS meter Characterstics of water Clear water with turbidity up to 50 PPM. a) Temperature 20 degree centigrade.
Providing control panel as per specifications and having protection of motor on occurance of faults { Triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, Single phasing, voltage imbalance, overload and short circuit } and indiation thereof by glowing fault lamp ; for motors above 30 KW another protection of Mechanical seal failure shall also be provided in addition to above protections; fitted with following components:-
a) Powder coated steel sheet fabricate enclosure of suitable size to accommodate the following accessories:-
b) Shnider /L&T/Havells/Standard and other approved make MCCB in MAINS on incomer side
c) Shnider/ Siemens and other approved make phase indicating lamps
d) Logestic or similar superior and other approved make 300VA transformer
f) AUTO/MANUAL switch Salzer/L&T/kaycee make
g) 3 Nos CONTACTORS of Spercher+ Schuh /L&T/Schnider /BCH/Siemens and other approved make, for star delta starting
h) Over load relay
i) STAR-DELTA TIMER ( for pumpset above 7.5HP)
J) SINGLE PHASING PREVENTOR
k) ON/TRIP INDICATING LIGHTS Schnider/ Siemens /L&T and other approved make
l) CONTROL MCB Schnider/ Havells/Standard/Siemens/ Legrand make
m) PUSH BT. Schnider/Siemens/L&T and other approved make
n) TERMINALS Phonix and other approved make
o) RCCB of Legrand/Siemens/Havells / L&T/ Standard and other approved make
p) Hour run meter of CE/Kaycee and other approved make
Providing Double flanged Leader / Pelican /Kirloskar and other approved make Cast iron Sluice Valve in delivery side conf. to Class IS 780 PN 1.0; one size higher than delivery outlet size of pump
Providing Double flanged Leader / Pelican /Kirloskar and other approved make Cast iron Swing check type Reflux Valve in delivery side conf. to Class IS 5312 PN 1.0; one size higher than delivery outlet size of pump
Prov. and laying PVC Insulated armoured copper conductor cable Havells/Gloster/Khaitan make of suitable size and suitable for motor offered under item No I complete with flexible pipe and couplers from HPSEB meter to Panel, switch, starter complete job, The type and size shall be subject to approval of Electrical authorities and in case of its non acceptance the same shall be replaced free of cost by the tenderer. Supply side : _25 mm^2 Motor side : _16_ mm^2
Prov. and laying PVC Insulated round copper conductor cable of suitable size suitable for motor offered under item No I complete having suitable cores to fulfill requirement of star delta starter and protection/ controls from panel to motor.
10 Mtr cable per set shall be supplied free of cost ( cost inclusive in cost of pumpset ) additional length shall be measured to and paid seperately. Cost to be quoted for additional length over and above free cable of 10 Mtr/ pumpset
Providing 100 mm dial pressure guage of Fiebig/Bourden and other approved make having range 0-7 Kg/cm^2 with copper tubing, stop cock and allied access.as per IS 3624 - 1987 latest with up to date amendments
Supply of cable for water level guard
Supply of supporting clamps
Supply of cable clips of required size
Erection of all equipments from Sr No 85 to 95 including cost of tee's bends, tappers and any other required fitting as per site condition and directions of engineer In charge.
Booster Stage - 2 Providing suitable Clear water submersible pumpset type KRT capable of handling 50 PPM turbidity of KSB / Kirloskar / CALAMA/Johnston / Oswal/BS and other approved make conforming to latest BIS code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible sq cage motor shaft conf to BIS 9238-1979 with up to date amendments of 1450 (N) RPM, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear,It should be fitted with device to take up expanion of water on heating of motor & suitable for operation on 415 +/- 10% volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- Discharge (Q) 5.96 LPS for each pump Total Dynamic head:- 85.86 meter a) LWL in sump well (h) 1069.00 meter b) Shaft level 1066.00 meter c) Level at discharge point 1140.00 meter d) Suction lift -ve meter e) Dynamic head 85.86 meter f) Static head 74.00 meter Rising main a) Length 450.00 meter b) Dia 100 mm Pumping hours 12.00 hours Altitude of installation above MS meter Characterstics of water Clear water with turbidity up to 50 PPM. a) Temperature 20 degree centigrade.
Providing control panel as per KSB specifications and having protection of motor on occurance of faults { Triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, Single phasing, voltage imbalance, overload and short circuit } and indiation thereof by glowing fault lamp ; for motors above 30 KW another protection of Mechanical seal failure shall also be provided in addition to above protections; fitted with following components:-
a) Powder coated steel sheet fabricate enclosure of suitable size to accommodate the following accessories:-
b) Shnider /L&T/Havells/Standard and other approved make MCCB in MAINS on incomer side
c) Shnider/ Siemens and other approved make phase indicating lamps
d) Logestic or similar superior and other approved make 300VA transformer
f) AUTO/MANUAL switch Salzer/L&T/kaycee and other approved make
g) 3 Nos CONTACTORS of Spercher+ Schuh /L&T/Schnider /BCH/Siemens and other approved make, for star delta starting
h) Over load relay
i) STAR-DELTA TIMER ( for pumpset above 7.5HP)
j) SINGLE PHASING PREVENTOR
k) ON/TRIP INDICATING LIGHTS Schnider/ Siemens /L&T and other approved make
l) CONTROL MCB Schnider/ Havells/Standard/Siemens/ Legrand and other approved make
m) PUSH BT. Schnider/Siemens/L&T and other approved make
n) TERMINALS Phonix and other approved make
o) RCCB of Legrand/Siemens/Havells / L&T/ Standard and other approved make
p) Hour run meter of CE/Kaycee and other approved make
Providing Double flanged Leader / Pelican /Kirloskar and other approved make Cast iron Sluice Valve in delivery side conf. to Class IS 780 PN 1.0; one size higher than delivery outlet size of pump
Providing Double flanged Leader / Pelican /Kirloskar and other approved make Cast iron Swing check type Reflux Valve in delivery side conf. to Class IS 5312 PN 1.0; one size higher than delivery outlet size of pump.
Prov. and laying PVC Insulated armoured copper conductor cable Havells/Gloster/Khaitan make of suitable size and suitable for motor offered under item No I complete with flexible pipe and couplers from HPSEB meter to Panel, switch, starter complete job, The type and size shall be subject to approval of Electrical authorities and in case of its non acceptance the same shall be replaced free of cost by the tenderer. Supply side : _25 mm^2 Motor side : _16_ mm^2
Prov. and laying PVC Insulated round copper conductor cable of suitable size suitable for motor offered under item No I complete having suitable cores to fulfill requirement of star delta starter and protection/ controls from panel to motor.
10 Mtr cable per set shall be supplied free of cost ( cost inclusive in cost of pumpset ) additional length shall be measured to and paid seperately. Cost to be quoted for additional length over and above free cable of 10 Mtr/ pumpset
Providing 100 mm dial pressure guage of Fiebig/Bourden and other approved make having range 0-7 Kg/cm^2 with copper tubing, stop cock and allied access.as per IS 3624 - 1987 latest with up to date amendments
Supply of cable for water level guard
Supply of supporting clamps
Supply of cable clips of required size
Erection of all equipments from Sr No 97 to 107 including cost of tee's bends, tappers and any other required fitting as per site condition and directions of engineer In charge.
Stage-1 (Lift-I) Supply of horizontal spindle horizontal/ redial split casing/end suction (Backpull out arrangement) Single/ double/ Multistage centrifugal pumps of combination of pumps in series/parellel of recommended make such as Mather and Platt/KSB/Beacon well/Kirloskar/BE/Jyoti as per BIS 1520-1980 with upto date amendments read with IS-9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze immellers/priming funnies casing ring and shaft sleeves of bronze shaft of steel grade 4508 FN8 with cast iron casing coupling directly through a flexible coupling and common MS/cast steel base plateform ( base plate to be from the manufacturer of the pumping unit only) to slip ring/screen protected drip proof induction motor/motors of standard make such as Kirloskar/BEL/Crompton/NGEF/GEC/Siemens/Jyoti ABB and suitable for operation on 400(+/-) 10% volts 50 cycles/ second 3 phase AC electric supply. The power of electric motor/motors should be designed +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor as per IS 325-1978 with up to date amendments read with IS 900-1972. It should include cost of bearing nuts bolts and painting etc and should meet the following requirement :- Discharge (Q) 17.51 LPS for each pump Total Dynamic head:- 732.64 meter a) LWL in sump well (h) 1137.00 meter b) Shaft level 1137.50 meter c) Level at discharge point 1810.00 meter d) Suction lift +ve meter f) Static head 672.50 meter Rising main a) Length 4420.00 meter b) Dia 150.00 mm Pumping hours 8.00 hours Altitude of installation above MS meter Characterstics of water Clear water with turbidity up to 50 PPM. a) Temperature 20 degree centigrade.
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells and other approved make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities
a) OCB/MCCB of MEI/Havels/ standard and other approved make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.
c) The voltage monitor relay of AE/MEI/L&T / Havells and other approved make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)
e) Digital Power factor meter of standard and other approved make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments or soft starter L&T Siemens/ABB/Allen bradley confirming to relevant ISO specifications with up to date ammendments for squirrel cage motor ( make to be specified by the tenderer ) mounted on pannel board with cage/Slipring motor.
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class ASA-300 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES make and of 125 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments
Installation of all the items apparing at serial No.1 to 13 as per the systematic drawing
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under: Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe
Common header : One dia higher then delivery of pump x 200 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor (a) Motor side (From switch to starter and starter to motor)
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.(For both phases).
Stage-2 (Lift-II) Supply of horizontal spindle horizontal/ redial split casing/end suction (Backpull out arrangement) Single/ double/ Multistage centrifugal pumps of combination of pumps in series/parellel of recommended make such as Mather and Platt/KSB/Beacon well/Kirloskar/BE/Jyoti as per BIS 1520-1980 with upto date amendments read with IS-9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze immellers/priming funnies casing ring and shaft sleeves of bronze shaft of steel grade 4508 FN8 with cast iron casing coupling directly through a flexible coupling and common MS/cast steel base plateform ( base plate to be from the manufacturer of the pumping unit only) to slip ring/screen protected drip proof induction motor/motors of standard make such as Kirloskar/BEL/Crompton/NGEF/GEC/Siemens/Jyoti ABB and suitable for operation on 400(+/-) 10% volts 50 cycles/ second 3 phase AC electric supply. The power of electric motor/motors should be designed +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor as per IS 325-1978 with up to date amendments read with IS 900-1972. It should include cost of bearing nuts bolts and painting etc and should meet the following requirementrequirements:- Discharge (Q) 13.82 LPS for each pump Total Dynamic head:- 513.27 meter a) LWL in sump well (h) 1807.00 meter b) Shaft level 1807.50 meter c) Level at discharge point 2300.00 meter d) Suction lift +ve meter e) Dynamic head 513.27 meter f) Static head 492.50 meter Rising main a) Length 2075.00 meter b) Dia 150.00 mm Pumping hours 8.00 hours Altitude of installation above MS meter a) Temperature 20 degree centigrade.
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells and other approved make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities
a) OCB/MCCB of MEI/Havels/ standard and other approved make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) and other approved make as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.
c) The voltage monitor relay of AE/MEI/L&T / Havells and other approved make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells and other approved make as per relevant IS code with upto dateammendments
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells and other approved make as per relvant IS code with uptodate ammendments
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells and other approved make and of suitable capacity as per IS:4064:1978 with upto date ammendments
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments or soft starter L&T Siemens/ABB/Allen and other approved make bradley confirming to relevant ISO specifications with up to date ammendments for squirrel cage motor ( make to be specified by the tenderer ) mounted on pannel board with cage/Slipring motor.
m) Providng Digital hour run meter of recommended and other approved make and suitable capacity as per IS:722(latest edition.)
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar and other approved make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses and other approved make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses and other approved make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class ASA-300 of Leader/BHEL/KILROSKER /Kartar /KILBURN/GLED/FOURSES and other approved make and of 125 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments
Installation of all the items apparing at serial No.1 to 13 as per the systematic drawing
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under: Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe
Common header : One dia higher then delivery of pump x 200 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor. (a) Motor side (From switch to starter and starter to motor)
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.(For both phases).
Stage-3 (Lift-III) Supply of horizontal spindle horizontal/ redial split casing/end suction (Backpull out arrangement) Single/ double/ Multistage centrifugal pumps of combination of pumps in series/parellel of recommended make such as Mather and Platt/KSB/Beacon well/Kirloskar/BE/Jyoti as per BIS 1520-1980 with upto date amendments read with IS-9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze immellers/priming funnies casing ring and shaft sleeves of bronze shaft of steel grade 4508 FN8 with cast iron casing coupling directly through a flexible coupling and common MS/cast steel base plateform ( base plate to be from the manufacturer of the pumping unit only) to slip ring/screen protected drip proof induction motor/motors of standard make such as oskar/BEL/Crompton/NGEF/GEC/Siemens/Jyoti ABB and suitable for operation on 400(+/-) 10% volts 50 cycles/ second 3 phase AC electric supply. The power of electric motor/motors should be designed +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor as per IS 325-1978 with up to date amendments read with IS 900-1972. It should include cost of bearing nuts bolts and painting etc and should meet the following requirement Discharge (Q) 4.50 LPS for each pump Total Dynamic head:- 279.20 meter a) LWL in sump well (h) 2297.00 meter b) Shaft level 2297.50 meter c) Level at discharge point 2520.00 meter d) Suction lift +ve meter e) Dynamic head 279.20 meter f) Static head 222.50 meter Rising main a) Length 2400.00 meter b) Dia 80.00 mm Pumping hours 8.00 hours Altitude of installation above MS meter Characterstics of water Clear water with turbidity up to 50 PPM.a) Temperature 20 degree centigrade.
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells and other approved make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities
a) OCB/MCCB of MEI/Havels/ standard and other approved make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC and other approved make) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.
c) The voltage monitor relay of AE/MEI/L&T / Havells and other approved make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells and other approved make as per relevant IS code with upto dateammendments
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells and other approved make and of suitable capacity as per IS:4064:1978 with upto date ammendments
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments
k) Capacitor of Mechneil/ BHEL/GEC and other approved make as per 15:2834:1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens and other approved make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments or soft starter L&T Siemens/ABB/Allen bradley confirming to relevant ISO specifications with up to date ammendments for squirrel cage motor ( make to be specified by the tenderer ) mounted on pannel board with cage/Slipring motor.
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar and other approved make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses and other approved make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses and other approved make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class ASA-300 of Leader/BHEL/KILROSKER/Kartar/KILBURN/GLED/FOURSES and other approved make and of 125 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments
Installation of all the items apparing at serial No.135 to 143 as per the systematic drawing
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under: Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe
Common header : One dia higher then delivery of pump x 200 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor (a) Motor side (From switch to starter and starter to motor)
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.(For both phases).
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .