MLA-SDF-MUKESH MLA sDF 2023-2024 DtV 51 THANKASSERI CONSTRUCTION OF BUS WAITING SHED AT ANCHU(ALLUMMOODU JNCTION-DlV 5 1 -General Electrical work
2025_LSGD_763020_9
PC4/16546/25
Open Tender
Electrical Works
Item Rate
120 days
KOLLAM MUNICIPAL CORPORATION
Please refer Tender documents.
7 documents required · 7 mandatory
₹300
Yes
₹1,170
Yes
30 Jun 2025
19 Jun 2025
30 Jun 2025
19 Jun 2025
27 Jun 2025
19 Jun 2025
19 Jun 2025 - 27 Jun 2025
Amount
Electrification
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD465237/2024-2025:Supply, conveyance, installation, testing and commissioning of recess mounting 18W down light fittings of all types on ceiling including cutting holes, giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. (LCDEP-12CDL of M/s Crompton / equivalent make)
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
OD462353/2024-2025:supply and providing 24 Hours digital timer for automatic ON/OFF operation of light and giving connection etc
OD462361/2024-2025:32 A 2 Way neutral link mounted on DMC/SMC base.
OD462364/2024-2025:Supply and fixing of HRC fuse holders and fuse base suitable to Cylindrical / DIN fuse link 32 A
OD462370/2024-2025:Supply and providing 32A 3pole ACI rated power contactor including giving connection etc as required
OD462372/2024-2025:Supply, installation, testing and commissioning of syntex make panel suitable to install meter for electricity supply and other accessories made out of sheet moulding compound (560x280x150mm) surface mounted or recess in wall ( indoor/outdoor use) one piece moulded SMC base and SMC door with internal hinges. knockout for wire entry, earthing bolt. includes contactor, MCB, connector, digital timer, RCCB, HRC fuse base with HRC fuse link,, earth wire, banana Al. socket, 2.5 sqmm ISI marked, FRLS PVC insulated single core copper conductor cable.
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Bidder Name
Kailas Electricals & Power Solutions
stage.html
html • 0.02 MB
finance_1257372.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .