Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.2 CrAccepted-AOC 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹67.2 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹70.5 CrRejected-Finance | ₹70.5 Cr | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹71.6 CrRejected-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹71.6 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹72.0 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹72.0 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹79.3 CrRejected-Finance | ₹79.3 Cr | L5 | Rejected-Finance Not being lowest |
Tender Value
₹67.9 Cr
EMD Value
₹15 L
Closing Date
17 Feb 2025, 6:00 pmClosed
CE NW KOCHI
CHIEF ENGINEER NAVAL WORKS KOCHI MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI-682004
PROVISION OF DEFICIENT MD ACCN FOR OFFICERS (LT CDR AND ABOVE) AT KATARIBAGH, NAVAL BASE KOCHI
2024_MES_677544_2
891062
Open Tender
Civil Works
900 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) KOCHI
₹15 L
Yes
17 Mar 2025
16 Jan 2025
20 Feb 2025
16 Jan 2025
17 Feb 2025
30 Jan 2025
16 Jan 2025 - 23 Jan 2025
Amount
Total amount of Sch 'A' Part-I : (Buildings/ Structures )
Total amount of Sch 'A' Part-II : (Excavation, earthwork, site clearance and site development)
Total amount of Sch 'A' Part-III : (Internal Water Supply)
Total amount of Sch 'A' Part-IV : (Internal Electric Supply)
Total amount of Sch 'A' Part- V : (External Water Supply )
Total amount of Sch 'A' Part-VI : (External Electric Supply)
Total amount of Sch 'A' Part-VII : (Lightning Protection)
Total amount of Sch 'A' Part-VIII : (Fire Fighting System)
Total amount of Sch 'A' Part-IX : (Area Drainage)
Total amount of Sch 'A' Part-X : (Sewage Disposal)
Total amount of Sch 'A' Part-XI (Road/ Path/ Hardstanding )
Total amount of Sch 'A' Part-XII : (Lift)
Sch 'A' Part- XIII : (Miscellaneous B/R & E/M Items (BOQ) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
PILE FOUNDATION
RCC with ready mix concrete (RMC) M30 grade with min 400Kg cement per cum in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV.Note:-(i) Reinforcement will be measured and paid separately under relevant items (ii) The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity tests.
RCC with Ready Mix Concrete(RMC) M30 grade in pile cap , grade beam / tie beam of any length/section complete all as specified and shown on drg. Note :- Reinforcement will be measured and paid for separately under relevant items of this Schedule.
CRS/HSCRS/HCRM TMT bars with epoxy coated 10 mm and above as in main reinforcement conforming to IS 1786 as in piles including cutting, bending, welding, tying, assembling, placing, maintaining in position the reinforcement cages complete all specified and as directed.
CRS/HSCRS/HCRM TMT bars with epoxy coated as in reinforcement 10mm dia and over for grade beams/tie beams and pile caps all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
CRS/HSCRS/HCRM TMT bars with epoxy coated in reinforcement 5 mm dia and over up to and including 16mm dia conforming to IS-1786 as in Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding .
CRS/HSCRS/HCRM TMT bars with epoxy coated 5mm dia and over upto and including 10mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in stirrups of grade beams and pile caps.
Plain Cement Concrete 1:4:8 (type-D2) using 40mm graded stone aggregate for concrete layer below grade beams complete all as specified and shown on drgs.
Plain Cement Concrete 1:3:6 ( type-C2) using 40mm graded stone aggregate for concrete layer below pile caps, ramp wall, grade beam and foundation complete all as specified and shown on drgs.
Formwork to sides of pile caps concrete foundation grade beams /plinth beam/tie beams/ base columns fair finished flat concrete surfaces all as specified .
Initial Load testing (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Initial Load testing (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Initial Load testing (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Initial Load testing (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Routine Load testing (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Routine Load testing (Vertical Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Routine Load testing (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600 mm dia cast in situ pile.
Routine Load testing (Lateral Load Test) of piles as per IS including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in situ pile.
Excavation over areas not exceeding 1.5m deep in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Excavating in trenches not exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exe 1.5M in depth and getting out in soft/ loose soil complete all as specified
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removal of surplus soil to a distance exceeding 1.5 Km and not exc. 5 Km deposited as directed.
Removing excavated soil to a distance n exc 50m depositing where directed at a level n exc 1.5m about the starting point
INTERNAL ELECTRIC SUPPLY Starter switch of capacity 20A,including socket and plug top working on 240 Volts AC supply and suitable for Air conditioners .Make : Crabtree cat part No.ACAO202504/Anchor /Legrand or equivalent make.
Ceiling fan 1200mm sweep copper wound having Min air delivery 210 CFM with service value not less that 4.50 with brushless direct current motor (BLDC) as per IS 374:2019 including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from connector to fan complete all as specified
Exhaust fan made of sturdy engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200 of sweep 250mm complete including making necessary provisions for mounting on walls all as specified and directed.
Exhaust fan made of sturdy engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200 of sweep 300mm complete including making necessary provisions for mounting on walls all as specified and directed.
LED Tube light 1X20 Watt 4' universal battern type with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site
LED Tube light 1X20 Watt 4' inverter LED batten square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours including 3 core 1sqmm PVC insulated multi stranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- LHEXACP7FN1W020 of Havells or equivalent in Philips/Wipro/Crompton
LED Light fittings mirror type with high output diffuser 2 feet 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with 3 core multi stranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- Havells or equivalent in Philips/Wipro
LED Light fittings decorative type wall mounting 1x9 watt 220 V AC with driver LED luminaire complete including connecting up with 3 core multi stranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- Havells or equivalent in Philips/Wipro
LED light 1X10 Watt 2' with and including connecting 3 core 1.0 Sqmm PVC insulated multi stranded copper conductor colour of sleeve matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- Crompton or equivalent in Philips/Wipro
Round shape 15 watts 220 Volts AC surface ceiling fitting including connecting 3 core 1.0 Sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting up complete all as specified and directed at site of Make/Model:- Crompton or equivalent in Philips/Wipro
Building LED security light 1x35W new generation energy saving and environmental friendly long life made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1sqmm PVC insulated multistranded copper conductor wire connecting pvc terminal to fitting. Make/Model:- Crompton or equivalent in Philips/Wipro
RCBOs for earth leakage, overload and short circuit protection double pole 30mA 16 A. Make Legrand or equivalent of Schneider/L&T.
RCBOs for earth leakage, overload and short circuit protection four pole 30mA 40- 63 A. Make Legrand or equivalent of Schneider/L&T.
Sub main wiring with 2 runs of 2.5 Sqmm PVC insulated unsheathed copper conductor multi stranded FRLS cable drawn in and including heavy duty steel conduit and its accessories laid concealed in wall/roof/floor etc including one run of 2.5 Sqmm multi stranded copper conductor cable for earth continuity wire including cutting chases complete all as specified and as directed. (Note: 03 runs of 2.5 sqmm and one run of concealed steel conduit will be measured as one unit length only)
Sub main wiring with 2 runs of 4 Sqmm PVC insulated unsheathed copper conductor multi stranded FRLS cable drawn in and including heavy duty steel conduit and its accessories laid concealed in wall/roof/floor etc including one run of 4 Sqmm multi stranded copper conductor cable for earth continuity wire including cutting chases complete all as specified and as directed. (Note: 03 runs of 4.0 sqmm and one run of concealed steel conduit will be measured as one unit length only)
Sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed copper conductor multi stranded FRLS cable drawn in and including heavy duty steel conduit and its accessories laid in concealed in wall/roof/floor etc including one run of 10 Sqmm multi stranded copper conductor cable for earth continuity wire complete including cutting chases all as specified and as directed. (Note: 05 runs of 10 sqmm and one run of concealed steel conduit will be measured as one unit length only)
Earth continuity conductor GI wire 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 V grade cross sectional area 10 Sqmm 4 core fixing wall/ground all as specified and directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 V grade cross sectional area 16 Sqmm 4 core fixing wall/ground all as specified and directed.
LED bulb 7 W, polycarbonate body 700 lumen all as specified and directed
TELE/TV SOCKET Rigid non-metallic PVC conduit 20 mm dia cocealed in wall inclusive of boxes junction/ terminal all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified
Rigid non-metallic PVC conduit 25mm dia cocealed in wall inclusive of boxes junction/ terminal all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified
TV socket 1 module complete with GI metal flush box 1 or 2 module, inner & outer modular cover plate suitable for 1 module complete all as specified
Tele socket 1 module complete with GI metal flush box 1 or 2 module, inner & outer modular cover plate suitable for 1 module complete all as specified
EXTERNAL WATER SUPPLY Cutting the existing DI water mains up to 250 mm or any dia and inserting Tee 250 x 250 x 100 mm or suitable size for taking up branch connection with and including DI fittings and jointing material as required and necessary excavation/earth work complete all as specified and as directed
Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 Nos steel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed
EXTERNAL ELECTRIC SUPPLY Feeder pillar box out door type, double door made out of CRCA sheet 3 mm thick duly grouted in earth incl PCC 1:3:6 type C-1 with locking arrangement and painting with following accessories suitable for incoming/out going arrangments:- (G+9) (MAIN INCOMER) (a) ACB 630 Amp 4 pole 36KA Adjustable type (microprocessor release) - 01 No (Bldg Incomer) (b) MCCB 250 Amp 25 KA 4 pole - Adjustable type 05 Nos (Meter Rm1 , 2, 3, 4 +1 spare) (d) Aluminium bus bar 800 Amp TPN - 01 set (e) Multi function digital meter (VAF & PF) - 01 No (f) Indicating lamp - 01 No (Set of three)
Design,fabrication, supply installation testing and commissioning of LT panel indoor type suitable to be mounted on PCC foundation/floor/duct all as per site requirement with cable entry from bottom with removable gland plates with required knockouts for incoming and outgoing cables. Panel shall be fabricated out of 2 mm thick CRCA sheet folded and brazed as necessary to provide rigid support for all components totally enclosed and degree of protection shall be IP-54 with front hinged lockable doors for the individual feeders / components treated by seven tank process & powder coated with approved colour. Doors and covers shall be fully gasket using good quality EPDM gasket and/or rubber strips, locking arrangement durable door opening and closing mechanism, Aluminium bus bar for three phases and nuetral busbar insulators, heat shrinkable Pvc sleeves etc. with necessary interconnection as specified comprising of the following switch gear. Note : Contractor shall submit GA drg for approval of GE before placing order (ii) Each switch gear shall be in separate cubicle.(iii) Cable alley shall be provided at side panel with adequate size width (iv) Each outgoing shall have Amp meter, CTs` ON /OFF indicator lamp. (For G+9 Block)
Item No. 66 (Contd....) INCOMER (a) MCCB 200 Amp 4 pole 36KA Adjustable type - 01 No. (b) Aluminium bus bar 300 Amp - 01 set (c) Multi function digital meter (VAF & PF) - 01 No OUT GOINGS (a) MCB 40 Amp 4 pole 10KA - 10 No.(KWH Meter- 9Nos +1No Spare) (b) Smart Meter , 3 phase, 415V, 10- 60 Amp as IS 16444-2015- (reafirmed 2020) and technical specification given in particular specification- 09 Nos. (c) Multi function digital meter (VAF & PF) - 01 No
All as per Item No.66 here -in- before but meter panel indoor type with CRCA sheet 2mm thick, IP -42 with and including the following for Bldg_(G+4) INCOMER (a) MCCB 160 Amp 4 pole 36KA Adjustable type - 01 No. (b) Aluminium bus bar 300 Amp - 01 set (c) Multi function digital meter (VAF & PF) - 01 No OUT GOINGS (a) MCB TPN 40 Amp 4 pole 10KA - 05 No.(KWH Meter- 4Nos +1No Spare) (b) Smart Meter 3 phase 415V, 10- 60 Amp as IS 16444-2015- (reafirmed 2020) and technical specification given in particular specification.-04 Nos
Supply & install feeder pillar box out door type made out of CRCA sheet 3 mm thick welded duly grouted in earth incl PCC 1:3:6 type C-1 with locking arrangement and painting with following accessories suitable for incoming/out going arrangments:- ( G+4 ) Main incomer (a) MCCB 320 Amp 25 KA_Adjustable type- 4 pole - 01 No (Incomer) (b) MCCB 160 Amp 25 KA -Adjustable type- 4 pole - 05 Nos (Meter Rm 1,2,3&4 +1 spare) (c) Aluminium bus bar 1000 Amp TPN - 01 set (d) Multi function digital meter (VAF & PF) - 01 No (e) Indicating lamp - 01 No (Set of three)
Supply and install hot dip octagonal poles of height 7.0 M with 1M single arm ( 40mm dia for fixing of street light fittings with pole top dia shall be 70mm and bottom dia 130mm, sheet thichness 3mm and base plate dimension 225x225x12mm including foundation bolt, pole earth connection all as specifgied and as directed.
LED street light fitting 1x35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including nuts, bolts & washers complete all as specified and as directed
Thermo plastic junction boxes IP 55 with metric knockouts for cable entry and four terminals suitable for LT cable upto the size of 2 core 25 Sqmm and the size of the box is 167mm x 125 mm 82 mm include 6Amp MCB one No. complete all as specified and as directed
Astronomical time switches astro type (having longitude and latitutude of indian cities in memory ) 230V single phase of 32 Amp 3 pole rating with contactor and control wiring fitted inside steel enclosure for switching on/off security lights. (Make same or eqvalent as : Havells, L&T / GIC, Indo asian-TL032AS0).
Supply and spread riddled soil in trenches for cable cushioning by using IS sieve to seperate the composite particle and refilling in trenches as cushining and rammed down to form a solid bed all as specified and directed. Note : Punned thickness shall be measured for payment purpose.The mesh of the screen through which the soil is riddled shall not exceed 12.5 mm IS sieve.
Cast iron ovel shaped LT Cable route indicator of size 130mmx100mmx6mm thick with letters embossed and fixed with 500mm long MS angle iron 25x25x5mm including earth work excavation as in post hole in any type of soil providing PCC 1:3:6, type C-1 using 20mm graded stone aggregate to hold the angle iron (by putting the split end of Angle iron in to the concrete) up to ground level and painting the exposed iron surface with grey colour over a coat of primer complete all as specified and as directed.
Supply installation testing LT panel ,factory made and outdoor ,floor mounted type suitable for 415 volts,3 phase 4 wire ,50Hz AC supply system having bus bar with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 160 Amps for phases & neutral mounted on porcelain insulators.The panel shall be weather proof ,dust and vermin proof IP65 class protection and fabricated out of 3mm CRCA sheet duly powder coated after seven tank process.The panel shall be front openable type adequate space allaround for accessories including internal wiring in the panel with FRLS non- flammable insulated multistranded /solid copper conductor cable 1100 volt grade IS 694 marked for PVC sleeved copper strips of appropriate size and comprising of following accessories.Panel shall be mounted on medium channel 75x4mm base frame duly painted with approved colour(G+4 bldg)
Item No. 76 (Contd....) (i)Incoming (a) 4 pole MCCB 100Amp (adjustable type),50Hz ,415 volt 25Ka-01 No ’ (b)Digital multifunction meter(V,A,Hz,Pf) with and including resin cast CTs-01Set (c )Phase indicating lamp (set of 3) (ii)Outgoings (a)4Pole MCCB 40 Amp,50Hz ,415 volt 25KA -02Nos (Fire panel,Lift-01) (b)4 pole MCCB 63 Amp 50Hz ,415 volt 25KA-01 (spare) (c )4 pole MCCB 32 Amp 50Hz ,415 volt 25KA-01 (spare) (d) MCB SPN 16-32 A -02 No
Supply installation testing LT panel, factory msade and outdoor, floor mounted type suitable for 415 volts,3 phase 4 wire , 50Hz AC supply system having bus bar with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 300 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof , dust and vermin proof IP65 class protection and fabricated out of 3mm CRCA sheet duly powder coated after seven tank process .The panel shall be front openable type adequate space all around for accessories including internal wiring in the panel with FRLS non- flammable insulated multi stranded /solid copper conductor cable 1100 volt grade IS 694 marked for PVC sleeved copper strips of appropriate size and comprising of following accessories.Panel shall be mounted on medium channel 75x4mm base frame duly painted with approved colour (G+9 bldg)
Item No. 78 (Contd....) (i)Incoming (a)4 pole MCCB 200Amp (Adjustable type),50Hz ,415 volt 25Ka-01 No’ (b)Digital multifunction meter(V,A,Hz,Pf) with and including resin cast CTs-01Set (c) Phase indicating lamp (set of 3) (ii)Outgoing (a)4Pole MCCB 40 Amp,50Hz ,415 volt 25KA -01 No (common light at ground floor/parking) (b)4 pole MCCB 63 Amp 50Hz ,415 volt 25KA-02 (lift-01&02) (c )4 pole MCCB 32 Amp 50Hz ,415 volt 10KA-01 (street light)) (d) MCB SPN 16-32 A -03No(spare) (d) Tome switches Astro type (having longitude and latitude of Indian cities in memory) 230V, single phase of 20Amp ratings with contactor and cotrol wiring for switching ON/OFF security light. Make:- Havells/L&T/GIC/IndoAsian
FIRE FIGHTING Supply, laying and testing of Flanged type Ductile Iron pipes 150 mm dia centrifugally cast (spun), Class K-9, with flanged ends conforming to IS 8329, in any lengths including necessary connection/joint material (rubber gasget, nut & Bolts etc) complete all as specified and as directed.
DI fittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable upto 150 mm dia, class K-12 complete all as specified and directed
Automatic gunmetal air release valve 25 mm dia complete all as specified and directed
Supply installation testing & commissioning CPRI approved Factory made and outdoor type wall mounted on wall brackets. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases & neutral mounted on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-65 class protection and fabricated out of 3 mm CRCA sheet duly powder coated after nine tank process. The panel shall be front openable type adequate space all around cessories such as LT switchgear and metering instruments including internal wiring in the panel with FRLS non flamable insulated multi stranded/ solid copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories. Panel shall be mounted on 40x40x6mm angle iron frame and painted with fire red colour. (i) INCOMING (a) MCCB 415 Volts,32-63 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 25 kA 1 Nos. (b) Digital multi function meter (V,A,Hz,Pf) with and including resin cast CTs - 01 Set. (c) Phase indicating lamp(set of 3).
Supply,lay ,testing and commisioning of flexible FRLS 2 core 1.5 sqmm copper conductor ,pvc insulaed ,cross laid up,overall aluminium Mylar tape shielded along with ATC drain wire PVC Outer sheated cable fixed on surface of wall/ceiling complete as required and as directed (for MCP) all as specified and directed . Note:- Layout of fire alarm system along with flexible FRLS 2-core copper cable on wall/ceiling connected to MCPs , alarm com strobe and fire alarm panel shalll be submitted to Engr-in -charge for approval before execution as per site condition.
Wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours all as specified and directed.
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM all as specified and directed .
AVIATION OBSTRUCTION LIGHT Avaition obstruction light LED type comprising of aluminium housing with polycarbonate enclosure (Make Bajaj Cat No BGAV 302 LED) or equivalent in other approved makes as specified
Sheet metal enclosure for MCB DB SPN 2 way, single door, 240 volts without bus bar complete all as specified
MCB SPN 10 Amps, 10 KA, 'C' curve complete all as specified
Supply, laying/ fixing on wall and testing cable XLPE insulated , screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified
Item No.93 (Contd....) alarm push button, built in floor annoucing system with 2 nos hand set at grounf floor and machine room and intercom mike unit in car cabin, etc with and including automatic rescue device (ARD) battery operated with and including maintenance free battery of suitable capacity and battery charger with to perform minimum 3 continue rescue operationoptimum direction section in start operation requiring no human intervention ,pit ladder, rescues during power/system failure with latest IGBT power devises, 3D infra red sensor in full length of doors andinvertor operated emergency light, over load indicator with suitable for three phase,415 Volts,50 Hz AC Supply for passenger lift including all connected civil works like RCC / PCC foundation, supports, Grutings, MS channels, Brackets etc complete all as specified and recommended by OEM.
Item No.95 (Contd....) alarm push button, built in floor annoucing system with 2 nos hand set at grounf floor and machine room and intercom mike unit in car cabin, etc with and including automatic rescue device (ARD) battery operated with and including maintenance free battery of suitable capacity and battery charger with to perform minimum 3 continue rescue operationoptimum direction section in start operation requiring no human intervention ,pit ladder, rescues during power/system failure with latest IGBT power devises, 3D infra red sensor in full length of doors andinvertor operated emergency light, over load indicator with suitable for three phase,415 Volts,50 Hz AC Supply for passenger lift including all connected civil works like RCC / PCC foundation, supports, Grutings, MS channels, Brackets etc complete all as specified and recommended by OEM.
HOT WATER SUPPLY Supply and fix electric water heater , storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
SEWAGE DISPOSAL Supply and laying of DWCPE (SN8)(OD)/163(ID) mm diameter pipes laid on 200mm thick bed with excavation in any type of soil, including earth work excavation ,PCC bed and haunching of pipe,return filling and removal of surplus soil 1.5 Km to 5.0 Km inside the defence land line functional for depth complete all as specified
MODULAR ELECTRIC CHIMNEY Modular electric chimney of size not less than 60cm ,max air flow less than 1200(M3/H),oil filter ,3 speed motion control ,LED light lamp ,good colour finish,heat auto clean technology ,easy to clean ,touch controls ,max noise level 55-68 db complete including aluminum flexible pipe ,ducting and chimney insulation all as specified and directed.
ARBORICULTURE: Supply and planting of Bermuda grass( by dibbling method @ 7.5 cm apart) over prepared surface with adequately devoleped root after providing antitermite treatment including preparation of surfaces , earth work excavation, removing surplus soil, filling od approved earth suitable for grassing 20cm thick after mixing of fertilizer/organic manure and regular maintenance of developed grass for one year
COMPREHENSIVE MAINTENANCE OF LIFTS AFTER DEFECT LIABILITY PERIOD
Note :- (a) Replacement of sheeve and steel ropes, if required during this period, will be carried out by the contractor but material shall be provided by the department for fixing only. (b) :- The comprehensive maintenance shall be done through OEM of the lift. (c) :- The Contractor shall enter into an MOU (Memorandum of Understanding) with the OEM or their authorised agency for maintenance of the lift. The above comprehensive AMC certificate shall be provided by the Contractor in favour of GE (NW) before commencement of work, after acceptance of CA. (d) :- The parts shall be genuine and shall be from original equipment manufacturer (OEM) and shall be approved by GE. (e) :- All stainless steel parts such as lift car enclosure, opening doors, jamps, cills etc shall be thoroughly cleaned to remove rust, stains etc with suitable solution. The Contrator shall also be clean and properly maintain machine rooms, machineries and lift well as directed by EIC. The rates quoted for respective items shall be deemed to include for the same. (f) :- No spare parts and consumables shall be supplied by the Department. (g) :- The rate of maintenance, service and repair including all the material and labour for the satisfactory functioning of the lifts.
All as per Item No.103 to 105 here -in- before but for the second year after completion of defect liability period
All as per Item No.103 to 105 here -in- before but for the third year after completion of defect liability period
All as per Item No.103 to 105 here -in- before passenger lift (G+9) having capacity (884Kg)/13 passengers at BoQ item Sl No.95 & 96, the first year after completion of defect liability period
All as per Item No.108 here -in- before but for the second year after completion of defect liability period
All as per Item No.108 here -in- before but for the third year after completion of defect liability period.
All as per Item No.103 to 105 here -in- before passenger lift (G+9) having capacity (544Kgs)/08 passengers at BoQ item Sl No.97, the first year after completion of defect liability period
All as per Item No.111 here -in- before but for the second year after completion of defect liability period
All as per Item No.111 here -in- before but for the second year after completion of defect liability period
INTERNAL WATER SUPPLY Brass butter fly valve 75mm dia complete all as specified
Bib tap, cast copper alloy chromium plated fancy type of size 15mm dia, long bodt with CP cup . Make Jaquar Cat No. CON-CHR-107KN or equivalent in other approved makes as specified and as directed.
Concealed stop cock chromium plated , fancy type with long shank and cup 15mm dia. Make Jaquar Cat No LYR-CHR- 38083K or equivalent in other approved makes as specified
Concealed stop cock chromium plated , fancy type with long shank and cup 20mm dia. Make Jaquar Cat No LYR-CHR- 38083K or equivalent in other approved makes as specified
Angular stop cock chromium plated, cast copper alloy screwed down, screwed for iron pipe 15mm dia bore. Make Jaquar Cat No CON-059KN or equivalent in other approved makes as specified
Brass CP mixer with hand shower 3 in 1. Make Jaquar Cat No COT-23281UPR with hand shower HSH-CHR-49537 or equivalent in other approved makes as specified
USHA CONSTRUCTIONS (BID ID -3240781)
FUTURE ONE FACILITY MANAGEMENT (BID ID -3241585)
JAIN BUILDER (BID ID -3233837)
S.N. Constructions (BID ID -3230572)
VIJAY CONSTRUCTIONS (BID ID -3233324)
SRICO PROJECTS PVT LTD (BID ID -3233272)
CHERIAN VARKEY CONSTRUCTION CO PVT LTD (BID ID -3239933)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid