Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.4 L+₹91,101.10 (2.25%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹44.3 L+₹3.8 L (9.32%)Rejected-AOC 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | L3 | Rejected-AOC L3 | |
| 4 | L4₹47.6 L+₹7.1 L (17.5%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹48.4 L+₹7.9 L (19.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Kuriako Mathai and company L8 | ZOOM ENTERPRISES L1 | Sreema Enterprises L6 | M/S AARJAY ASSOCIATES L4 | Bell Builders L5 | ROTECH ENGINEERS AND BUILDERS L7 | ELSOL ENGINEERS L2 | A2Z ENGINEERS AND PILE FOUNDATIONS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending internal/External electric complaints for maintenance/breakdown round the clock for maintenance, checking, fault finding ad rectification of fault in LT panels overhead HT/LT Lines, HT/LT underground cables, Transformers, switchgears internal electric faults, fans etc and carry out repairs and resume electric supply complete all as specified and directed
Notes:- (a) Day to day complaint rectified by the electrician shall be written in complaint register and complaint document slip, rectified complaints only shall be measured and paid. Complaint attender shall have minimum qulification of ITI Electrician cum pumber having 2 years experiance of same nature of work is to be employed.
(b) The spares required for rectification of faults shall be measured under relevent items. (c) All necessory tools shall be made available with the tecnician while executing the complaint.
(d) All consumeables other than mentioned in schedules are deemed to be included in the rate quoted. (e) All kind of transport for the complaint attender/materials and mobile/cell charges are deeme to be included in the rate quoted.
(f) All safety aspects are to be taken and if any accident/hazardous incidents happen during execution shall be the sole resposibility of the contractor.
(g) Penalty of Rs 1000/- per complaint will be recovered from contractor if the complaint will not rectified within 24 hours. | 920 | Each | 300 ₹2,76,000 | 200 ₹1,84,000 | 250 ₹2,30,000 | 210 ₹1,93,200 | 250.33 ₹2,30,303.6 | 260 ₹2,39,200 | 250 ₹2,30,000 | 195 ₹1,79,400 Lowest |
| 2.00 | Supply and fix in replacement switch piano, flush type single pole, one way 6 Amp, 230V complete all as specified and directed | 39 | Each | 45 ₹1,755 | 50 ₹1,950 | 45 ₹1,755 | 80 ₹3,120 | 60.3 ₹2,351.7 | 47 ₹1,833 | 25 ₹975 Lowest | 72 ₹2,808 |
| 3.00 | Supply and fix in replacement switch piano, flush type single pole, two way 6 Amp complete all as specified and directed | 10 | Each | 55 ₹550 | 50 ₹500 | 80 ₹800 | 47 ₹470 | 65 ₹650 | 86 ₹860 | 40 ₹400 Lowest | 75 ₹750 |
| 4.00 | Supply and fix in replacement Bell push, flush type, 6 amp complete all as specified and directed | 20 | Each | 40 ₹800 Lowest | 50 ₹1,000 | 45 ₹900 | 50 ₹1,000 | 60 ₹1,200 | 50 ₹1,000 | 50 ₹1,000 | 70 ₹1,400 |
| 5.00 | Supply and fix in replacement socket outlet flush type, 6 A complete all as specified and directed | 40 | Each | 47 ₹1,880 Lowest | 80 ₹3,200 | 90 ₹3,600 | 120 ₹4,800 | 100 ₹4,000 | 95 ₹3,800 | 50 ₹2,000 | 125 ₹5,000 |
| 6.00 | Supply and fix in replacement switch socket combination 2 in 1, 6 A flush type complete all as specified and directed | 40 | Each | 77 ₹3,080 Lowest | 120 ₹4,800 | 160 ₹6,400 | 100 ₹4,000 | 150 ₹6,000 | 175 ₹7,000 | 110 ₹4,400 | 145 ₹5,800 |
| 7.00 | All as per Item No 6 here-in-before but 6A/16A, 5 in 1 complete all as specified and directed | 30 | Each | 120 ₹3,600 Lowest | 150 ₹4,500 | 170 ₹5,100 | 180 ₹5,400 | 200 ₹6,000 | 175 ₹5,250 | 200 ₹6,000 | 260 ₹7,800 |
| 8.00 | Supply and fix plug top 3 pin 16 Amps, 240 volts, bakelite body, all as speified and directed. | 10 | Each | 88 ₹880 | 170 ₹1,700 | 250 ₹2,500 | 210 ₹2,100 | 230 ₹2,300 | 245 ₹2,450 | 60 ₹600 Lowest | 180 ₹1,800 |
| 9.00 | Supply and fix replacement bell musical (ding dong type) , AC, 230 volts, single pole complete all as specified and as directed | 20 | Each | 220 ₹4,400 | 350 ₹7,000 | 360 ₹7,200 | 410 ₹8,200 | 400 ₹8,000 | 350 ₹7,000 | 150 ₹3,000 Lowest | 600 ₹12,000 |
| 10.00 | Supply and fix in replacement stepped type electronic fan regulator flush type, hum proof, AC 240 V, 5 Step two module complete all as specified and directed. | 40 | Each | 300 ₹12,000 | 450 ₹18,000 | 530 ₹21,200 | 440 ₹17,600 | 430 ₹17,200 | 550 ₹22,000 | 225 ₹9,000 Lowest | 520 ₹20,800 |
Tender Value
Refer Docs
EMD Value
₹89,480
Closing Date
25 May 2026, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
DAY TO DAY MAINT OF INTERNAL E/M WORKS AND SUMMER APPLIANCES FOR OTM RESIDENTIAL BLDGS AT NAD, NTS(K), PERIYAR VIHAR NAE AREA UNDER AGE B/R ALWAYE AND REPAIR/REPLACEMENT OF STREET LIGHT, SECURITY LIGHT AND LT DISTRIBUTION SYSTEM AT NAD, TS(K)
2026_MES_763344_1
8653/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ALWAYE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NS KOCHI
₹89,480
Yes
1 Aug 2026
4 May 2026
27 May 2026
4 May 2026
25 May 2026
19 May 2026
4 May 2026 - 5 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending internal/External electric complaints for maintenance/breakdown round the clock for maintenance, checking, fault finding ad rectification of fault in LT panels overhead HT/LT Lines, HT/LT underground cables, Transformers, switchgears internal electric faults, fans etc and carry out repairs and resume electric supply complete all as specified and directed
Notes:- (a) Day to day complaint rectified by the electrician shall be written in complaint register and complaint document slip, rectified complaints only shall be measured and paid. Complaint attender shall have minimum qulification of ITI Electrician cum pumber having 2 years experiance of same nature of work is to be employed.
(b) The spares required for rectification of faults shall be measured under relevent items. (c) All necessory tools shall be made available with the tecnician while executing the complaint.
(d) All consumeables other than mentioned in schedules are deemed to be included in the rate quoted. (e) All kind of transport for the complaint attender/materials and mobile/cell charges are deeme to be included in the rate quoted.
(f) All safety aspects are to be taken and if any accident/hazardous incidents happen during execution shall be the sole resposibility of the contractor.
(g) Penalty of Rs 1000/- per complaint will be recovered from contractor if the complaint will not rectified within 24 hours. | 920 | Each | - | - |
| 2 | Supply and fix in replacement switch piano, flush type single pole, one way 6 Amp, 230V complete all as specified and directed | 39 | Each | - | - |
| 3 | Supply and fix in replacement switch piano, flush type single pole, two way 6 Amp complete all as specified and directed | 10 | Each | - | - |
| 4 | Supply and fix in replacement Bell push, flush type, 6 amp complete all as specified and directed | 20 | Each | - | - |
| 5 | Supply and fix in replacement socket outlet flush type, 6 A complete all as specified and directed | 40 | Each | - | - |
| 6 | Supply and fix in replacement switch socket combination 2 in 1, 6 A flush type complete all as specified and directed | 40 | Each | - | - |
| 7 | All as per Item No 6 here-in-before but 6A/16A, 5 in 1 complete all as specified and directed | 30 | Each | - | - |
| 8 | Supply and fix plug top 3 pin 16 Amps, 240 volts, bakelite body, all as speified and directed. | 10 | Each | - | - |
| 9 | Supply and fix replacement bell musical (ding dong type) , AC, 230 volts, single pole complete all as specified and as directed | 20 | Each | - | - |
| 10 | Supply and fix in replacement stepped type electronic fan regulator flush type, hum proof, AC 240 V, 5 Step two module complete all as specified and directed. | 40 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
COMMONPAGES8653.pdf
Tender Documents • 0.56 MB
PS8653.pdf
Tender Documents • 0.85 MB
BOQ_855041.xls
BOQ • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .