The Deputy Executive Engineer Electrical R and B Sub Division PWD Campus Panvadi Bhavnagar
PROVIDING & ERECTING SOLAR ROOFTOP PLANT AT M.J. COMMERCE COLLEGE,VIDHYANAGAR -BHAVNAGAR,TA. & DIST.:- BHAVNAGAR.
367873
E Tender 14 of 2026-27
Open
Electrical Works
Works
Bhavnagar
1 document required · 1 mandatory
₹900
The Executive Engineer, Electrical R&B Division, Bhavnagar
₹8,000
20 Nov 2026
20 Nov 2026
20 Nov 2026
5 Dec 2026
20 Nov 2026
90 days
OF PROVIDING & ERECTING SOLAR ROOFTOP PLANT AT M.J. COMMERCE COLLEGE,VIDHYANAGAR -BHAVNAGAR,TA. & DIST.:-
WORK BHAVNAGAR.
SR NO ITEM QTY. UNIT IN WORDS Amout
1 Supply, Installation, Testing & Commissioning of following size of 18 PER KW 42455.35 Rupees Forty Two
Grid Tied Solar Power Plant with Thousand Four
Solar Panels (ALMM approved): Frame Material : Anodized Hundred Fifty Five
Aluminum alloy Frame With Twin Wall Profile, Front Cover : High And Paise Thirty Five
Transmission Low-Iron Tempered Glass (AR Coated), High Only
efficency and positive power tolerance Pmax: 0/+5, Module
Efficiency should be approx. 19.5%-22%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep. temp.
co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to be
used. Unit Production:- More than 4.5 Unit /kw /day (Actual)(1Year
Avg) With 10 year Product warranty. Modules must be complied to
the DCR(Domestic content requirements). The Ration of AC to DC
is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max
efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating
Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Integrated protection of
Inverter are Anti-islanding Protection, Input Reverse Polarity
Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection,
Output Short Circuit Protection, Output Over Voltage Protection, PV
array string fault Protection. Protection Degree: IP65, User Interface
LCD & APP, Datalogger & Communication: GPRS / Wi-Fi.
0 Integrated, Input Reverse Polarity Protection Integrated, Insulation
Resistor Detection Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection Integrated, Output Short
Circuit Protection Integrated, Output Over Voltage Protection
Integrated, Protection Degree: IP65, User Interface LCD &
APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting
Structure: The mounting (Rectangular pipe / square pipe / circular
pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep
galvanized with minimum 80micron coating. The Rectangular /
square /circular hollow pipe section used for the structure should
have a minimum thickness of 2.0 mm. other than above, the
material thickness should be minimum 2.5 mm. A certificate of a
structural engineer certifying the strength and stability of the
mounting structure to withstand the weight and wind speed of
km/hour , shall be submitted by the vendors. Hot Dipped Galvanized
steel coils. suitable arrangement for base plate for foundation , solar
panel mounting, the structure should be suitable for carry the load of
solar panel,wiring, sprinkler system etc. with necessary foundation
work/wall mount, j bolt, anchor fastner etc. the nut bolt used for
installtion of stucture should be (SS 304) quality.The ground
clearance of the bottom most edge of solar panel shall not be less
than 300 mm to 1200 mm or as per site’s technical/feasibility
a. Column –The minimum section (thickness) should be
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM
Balane of System with necessary Swichgears (Suitabel size and
protection of ACDB & DCDB), inter connecting wiring, earthing
system as per the CEIG drawing approval, lightining arrester
system as per the CEIG drawing approval, all liasoning work with
various gov. dipartment like state nodal agency,DISCOM & CEIG is
included in agency scope (Excluding All charges namely GEDA
Application fees, Solar connectivity Charges, Meter connectivity
Charges, Meter testing Charges and system stability/strenthning
charges.) (C ) Grid Tied Solar Power System: 11 - 25 kW (3 -
AMOUNT PUT TO TENDER FOR RS.
Rupees Seven Lakh(s) Sixty Four Thousand One Hundred Ninety Six And Paise Thirty Only
(A) Total Tendered Amount Rs..…..……………….…………...…………….
(B) Rebate on above tendered amount (if any)………………..…..%(in Figure) Rs….………………….………………………...
(C) Net tendered amount (A-B) Rs……………………………………………….
All work shall be carried out as per Public Works Department Handbook and other specification of Division or as directed
Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under all
conditions, site, moisture, weather etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
nivida-14.pdf
tender details SOLAR M J COM.pdf
sch-a M J COM.pdf
SCH-B M J COM.pdf
SBD M J COMM.pdf
Additional Instruction (3).pdf
Eligibility Criteria for solar work (1) (2).pdf
general condition and performa M J COM.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .