Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC VILL NIMOO LEH LADAKH 194101 | NIMOO | LEH | LADAKH | 194101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.8 L+₹68,562 (9.65%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹7.8 L+₹69,515 (9.78%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹8.2 L+₹1.1 L (15.4%)Rejected-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹8.9 L+₹1.8 L (25.3%)Rejected-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹19,900
Closing Date
21 Dec 2020, 6:00 pmClosed
AGE (I) NIMU
AGE (I) NIMU, LEH
Repair / Replacement of LT Panels and connected works at Nimu Military Station
2020_MES_398307_1
AGE(I)/NIT-27/2020-21
Open Tender
Civil Works
Item Rate
180 days
Nimu
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) NIMU
₹19,900
Yes
19 Feb 2021
25 Nov 2020
22 Dec 2020
25 Nov 2020
21 Dec 2020
9 Dec 2020
Amount
Dismantling and Taking down U/S Changeover, MCCBs, Voltmeter/ Ampmeter, phase indicator, all outgoing and incoming connections and making good the disturbed area from site all as specified and directed by Engineer-in-Charge.
M&L for in replacment of on Load Changeover four pole with advance neutral of capacity 630 A in existing panel complete including doing connections with bus bar and outgoing cables, nuts bolts washers, thimbles complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No - HCNFO0630 and equivalent in L&T/Hager
M&L for in replacment of MCCB 630 A, breaking capacity 36 KA at 415 V, four pole adjustable thermal and adjustable magnetic settings confirming to IEC:60947-2 with extended terminals and separator links complete including doing connections with bus bar and outgoing cables, nuts bolts washers complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No - IHLLSEBF0630 # and equivalent in L&T/Hager
M&L for in replacment of MCCB 400 A, breaking capacity 36 KA at 415 V, four pole adjustable thermal and adjustable magnetic settings confirming to IEC:60947-2 with extended terminals and separator links complete including doing connections with bus bar and outgoing cables, nuts bolts washers complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No - IHLLSEBF0400 # and equivalent in L&T/Hager
M&L for in replacment of MCCB 250 A, breaking capacity 35 KA at 415 V, four pole adjustable thermal and adjustable magnetic settings confirming to IEC:60947-2 with extended terminals and separator links complete including doing connections with bus bar and outgoing cables, nuts bolts washers complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No - IHLFNF0250 # and equivalent in L&T/Hager
M&L for in replacment of MCCB 100 A, breaking capacity 25 KA at 415 V, four pole adjustable thermal and adjustable magnetic settings confirming to IEC:60947-2 with extended terminals and separator links complete including doing connections with bus bar and outgoing cables, nuts bolts washers complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No - IHLASDCF0100 # and equivalent in L&T/Hager
M&L for in replacment of Digital Volt Meter 0 - 500 volts, 96mm x96 mm complete for LT Panel all as specified and directed by Engineer-in-Charge. Make : AE
M&L for in replacment of Digital Amp Meter CT 0- 300 Amps, 96mm x96 mm complete for LT Panel all as specified and directed by Engineer-in-Charge. Make : AE
M&L for in replacment of Digital Frequency Meters 96mm x96 mm complete for LT Panel all as specified and directed by Engineer-in-Charge. Make : AE
M&L for in replacement of R Y B phase indicating lamp LED type complete for LT Panel all as specified and directed by Engineer -in- Charge. Make: Esbee
Supply only Aluminium Thimble of size 10/16/35/50/70/95 sqmm, complete all as specified and directed by Engineer - in - Charge.
Supply only Aluminium Thimble of size 120/150/185/240/300 sqmm, complete all as specified and directed by Engineer - in - Charge.
M&L for cable jointing kit for LT UG cable with 1100 volts straight through joints kit epoxy type of size 50 sqmm 3.5 core, complete all as specified and directed by Engineer - in - Charge.
Description all as per item No. 15 here-in-before but size 70 to 120 sqmm.
Description all as per item No. 15 here-in-before but size 150 to 185 sqmm.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm
Description all as per item No. 18 here-in-before but size 120 to 185 sqmm.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sqmm 3 Core, including taking out old cable. Make : Havells/Polycab
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sqmm 3 Core. including taking out old cable. Make : Havells/Polycab
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole/ stay and laying of UG cable and getting out in any type of loose/rocky/hard soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as directed.
S&F DWC tubing of size 90/75 mm dia for laid in trenches/along the pole/wall for protection of cable complete all as specificifide and directed.
S&F DWC tubing of size 120/103 mm dia for laid in trenches/along the pole/wall for protection of cable complete all as specificifide and directed.
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sqmm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sqmm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
Laying only XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300/400 sq. mm 3.5 core. including taking out old cable. (Note : Cable will be issued under Sch 'B' free for laying.)
M&L for welding of doors of Panels at various locations.
M&L for Busbar chambers with 4 aluminium busbar strip of rating 100 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm complete all as specified and directed by Engineer in Charge. Make : Havells Cat Part No. : HBC010006
M&L for Busbar chambers with 4 aluminium busbar strip of rating 250 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm complete all as specified and directed by Engineer in Charge. Make : Havells Cat Part No. : IHBC025006
M & L and Replacement of earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less'than 1.5m below normal ground level, connected to galvanised iron strip 32 x 6mm ( incl upto 7.5m) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion with charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) , all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge.
SUMEET TRADING CORPORATION
M/S MOHD KARIM
M/S BALI CONSTRUCTIONS
M/S TRADE LINK
SINGH CONST CO
darshan kumar gandhi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .