Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
7 Sept 2022, 6:00 pmClosed
GE (ARMY) CENTRAL JODHPUR
GE (ARMY) CENTRAL MULTAN LINES ARMY AREA JODHPUR
SPL REPAIR TO OR LINE BATHROOM TOILETS IN BLDG NO P 352 OF ARMD REGT AND HARDSTANDING IN FRONT OF BLDG NO P 16 FRESH SHED AT COY ASC AT AGE B R II AREA UNDER GE ARMY CENTRAL JODHPUR
2022_MES_544375_1
GE/J/A OF 2022-23 (9127/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹1 L
29 Sept 2022
10 Aug 2022
10 Sept 2022
10 Aug 2022
7 Sept 2022
24 Aug 2022
Amount
Note:- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are requested to quote their rates accordingly. (ii) Makes of materials will be approved by GE in writing before commencement of work.
S&F in repair 1000 ltrs capacity rotational moulded polythene water storage tanks white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, including dismantling of old U/S PVC/RCC water tank & removing to store or outside MD land or credit to contractor, complete all as specified and as directed by Engg.-in-charge. Make:- Sintex / Rotex as approved by GE
Taking up or down 15mm bore GI tubing and connections including cleaning for refixing or credited to contractor, complete all as specified and as directed by Engg.-in-charge.
All as per item No. 3.00 above, but of size 20 mm bore, complete all as specified and as directed by Engg.-in-charge.
All as per item No. 3.00 above, but of size 25 mm bore, complete all as specified and as directed by Engg.-in-charge.
S&F GI tubing, 25 mm bore, medium grade, galvanized, with all fittings fixed to wall, ceilings or laid in floors, complete all as specified and as directed.
All as per Item No. 6.00 here-in-above, but of size 20 mm bore, complete all as specified and as directed by Engg.-in-charge.
All as per Item No. 6.00 here-in-above, but size 15 mm bore including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE, overall thickness not exceeding 200 mm, including demolition of existing cement concrete, taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removal of demolished/unserviceable materials, debris & rubbish to outside MD land, complete all as specified and as directed by Engr-in-Charge.
M&L for carring out water proofing treatment for roof in following stages :- (1) M&L for rendering 10mm thick in 1:4 mixed with integral water proofing liquid all as per mfr inst over conc surfaces finished even and smooth w/o using extra cement. (2) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/Sqm over plastered surafces (3)Second layer of 3 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcement & having weight 3 Kg/sqm with mineral gravel finish on top complete laid over Roof slab/padding surfaces over a coat of Bitumen 85/25 applied @ 1.20 kg/Sqm complete all as specified & directed at site. NOTE :- (i) WPC shall be measured and paid separately under respective item. (ii) This work shall be carried out by engaging authorized applicator of the manufacturer of APP membrane.
M&L for plain cement concrete 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate), as in sub base of roof treatment work, over roof for making good depression / undulation to make the existing as filling in depression of roof slab, complete all as specified & directed by Engineer-in-charge.
M&L Mild steel sections like angle, channel, flat, square etc as in framed work such as, guard bars, brackets & supports for sunshade roof slab, for jacketting around coluns, grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, barred iron doors; ladders ;framed balusters walk ways, MS plates & bolts railings framed work of water tanks, including necessary welding in position & etc. and similar work conforming to Fe-290Gde E-165 complete all as specified and as directed by Engg.-in-charge.
Taking down carefully cement conc /spalled out concrete from RCC roof projections, ceiling ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scaffolding etc, complete all as directed by Engr-in-Charge.
M&L for cleaning the existing reinforcement of slabs, chajjas etc., & applying a coat of SIKA RUSTOFF 11 to remove the loose rust particles etc & throughly cleaning the surface, complete all as specified and as directed by Engr-in-Charge.
M&L for 15-20 mm thick rendering in CM 1:1:2 using1 part of cement 1 part 2-3 mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & rough to receive final rendering coat, complete all as specified and as directed by Engr-in-Charge.
M&L for 5 mm thick rendering in CM 1:3 & finishing the surface even & smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
S&F MS Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt,include for straightening, raking or circular cutting and waste, complete all as specified and as directed by Engr-in-Charge.
M&L for 10-15 mm thick rendering in CM 1:3 over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & smooth, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of chiken wire mesh/netting of stainless steel wire of 0.71 mm dia,12 mm mesh size, around RCC chajjas/facias etc., fixed with tinned tacks of stainless steel wire staples for covering UG sump air vent, when fixed in panels of joinery the rates include for fixing with beads supplied with joinery., complete all as specified and as directed .
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and as directed.
Racking out joints/ pointing to to squared rubble masonry Jodhpur type, regular coursed, masonry built in cement mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered surface wet for two days prior to re-pointing or plastering complete all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth with out using extra cement, complete all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick in cement mortar1:4 on stone masonry surfaces finished fair and even with out using extra cement including mixing with integral water proofing compound ( WPC) as per manufacturer instructions, complete all as specified & directed by Engineer-in-charge. Note :- WPC will be measured and paid separately as supply only.
Rendering 10mm thick in cement mortar 1:4 on concrete ceiling surfaces / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed.
Complete removal of existing treatment of any description on walls, obtain even surface all as directed by Engg.-in-charge.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.
Preparation of old surfaces of ceiling including cornices, beams, etc (plastered or unplastered) by brooming or steel wire brushing, scrapping down smoke spot moulds, moss efflorescent salts and trading oil greasy spot and applying one coat of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
Preparation of old surfaces of wall including cornices, pillar, etc (plastered or unplastered) by brooming or steel wire brushing, scrapping down smoke spot moulds, moss efflorescent salts and trading oil greasy spot and applying one coat of white wash on wall complete all as specified and directed by Engineer-in-Charge.
Preparation of old/newly plastered surface of walls and applying two coats of wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of acrylic distemper, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or un-plastered surfaces of wall by Brooming down or steel wire brushing, scrapping down mass and efflorescent salts and trading oil & greasy spots, washing rubbing down and stopping surfaces and applying two coats of cement base paint approved quality & tint, including & over one coat of primer, complete all as specified and directed by Engineer-in-Charge.
Preparation of old painted external surfaces of walls and applying one coat of cement base paint, complete all as specified and as directed.
M&L for carrying out texture paint, finishes exterior grade on wall surface, RCC chajjas, fascias, roof projection & etc, of approved pattern and to obtain the desired finish all as per sample, including preparing the old/new surfaces making good to depressions etc with a coat of putty etc, complete all as per specified & directed by Engg.-in-charge.
Demolition of cement concrete in ground floor or pavings n exc 15 cm in depth, as in flooring / plinth protection, below or above ground level,and removing rubbish to out side MD land complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as directed.
M&L for 16-18mm thick Udaipur green marble machine cut in cooking platform, stone slab size, shape & shade as approved by GE, including & over 15mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including rubbing, polishing and rounding the edges as required, complete all as specified and as directed by Engr-in-Charge.
M&L for 18-20 mm thick telephone black shade granite stone, machine cut, mirror polished best quality as per sample, as in floor, cooking plateforms, counter slab for oval shape wash basin, including & over 15 mm thick screeding in CM1:4, including rounding of the edges & providing suitable dia hole in the slab for the gas/water supply pipe, complete all as specified and as directed.
Joint free, non skid ceramic tiles (premium quality), coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular], size, shape, colour/shade of tile as approved by Engg.-in-charge, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including & over screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Johnson as approved by GE.
Joint free, non skid ceramic tiles (premium quality), coloured, of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular], size, shape, colour/shade of tile as approved by Engg.-in-charge, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including 15 mm thick screed bed or bedding layer of cement mortar 1:4, complete all as specified and as directed. Make : Kajaria/ Somany/ Johnson as approved by GE.
All as per item No. 38.00 here-in-above, but as on verticle surface such as skirting, dados and risers to step etc., including & over 10 mm thick backing coat of cement motar 1:4, complete all as specified and as directed. Make : Kajaria/ Somany/ Johnson as approved by GE.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete complete all as specified and as directed.
M&L 50mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) laid in alternative bays as in plinth protection including finishing the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight, complete all as specified and directed.
M&L 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate , as in sub base of flooring etc., incl finishing the surface even & rough to receive tile, complete all as specified and as directed.
Joint free coloured glazed ceramic tiles (premium quality) of size 300mm x 450mm x 7mm / 350 x 250 x 7 mm thick on vertical surface of wall, size, shape, colour/shade of tile as approved by Engg.-in-charge, including and over 10mm thick backing coat in CM 1:4 set and jointed in neat cement slurry and pointed in white cement / coloured cement to match the tiles (Highlighter pattern) complete all as specified and as directed. Note:- Tile shall be in one or more patterns including highlighters. Make : Kajaria/ Somany/ Johnson as approved by GE.
S&F in repair bib cock with wall flange, chromium plated, cast copper alloy, fancy type quarter turn suitable for 15mm bore pipe, complete all as specified and as directed. Make : Jaquar Cat No. OPP-15037 or equivalent in Kohler/ Cera as approved by GE
S&F in repair angular stop cock with wall flange, chromium plated cast copper alloy, fancy type quarter turn, suitable for 15mm bore, complete all as specified and as directed. Make : Jaquar Cat No. KUP-35053PM or or equivalent in Kohler/ Cera as approved by GE.
Demolition of existing WC floor including PCC/ tile flooring ,traps attached to WC , lean concrete ,plaster and removing all debrises off the site and removing rubbish to out side MD land complete all as specified and as directed.
M/L for rendering 15mm thick in cement mortar (1:4) on wall/floor surfaces of sunken floor finished even and smooth with using WPC as per manufacturing instruction including Cleaning the surfaces of sunken floor using wire brush , brooming down and washing down with water to remove dust etc., complete all as specified and directed .
M&L a layer of 50 micron polythene film pasted with the help of suitable adhesive, as in sunken floor, complete all as specified and directed.
M & L for PCC 1:5:10 type E2 ( using 40 mm graded stone aggregates), as in sunken floor bedding/mass filling work, connecting to drain pipe and flushing pipe etc., complete .
S & F superior class vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm with integral foot rests andPVC 'P' or 'S' trap, flush pipe of 32mm dia HDPE pipe etc., complete all as specified and as directed. Make:- Cera Cat No. CABLE S3020105 (Ivory) or equivalent in Hindware / Parryware as approved by GE
S&F in repair of 20 mm bore gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe & fixed, complete complete all as specified and directed.
S & F in repair over head shower rose 150X150mm square shape single flow ,body and face plate brass with CP ,arm 300mm long joiting to pipe complete all as specified and as directed. Make : Jaquar Cat No. OHS-1757 or equivalent in Kohler/ Cera as approved by GE
S&F Cast iron nahani trap with CP grating out let diameter 75mm including jointing to waste pipe fixed in cement mortar 1:1, complete all as specified and as directed.
S&F in repair Vitreous China wash basin, (Ivory / Superior colors), Oval type (Under counter basin) size not less than 500x385x150mm size as per trade pattern, fixed to stone slabs, complete including CP waste coupling & flexible waste pipe and CP, fancy type, cast copper alloy pillar tap, complete all as specified & directed by Engg.in-charge. Make:-Cera Cat. No. S2030104 or equivalent model in Hindware / Parryware as approved by GE
S&F 9/10 ltrs capacity PVC valve less(Super special colors), (ISI Marked) syphonic action type, flushing cistern, low level, with Anti Bacterial Knob, with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia and PVC connection 15mm size, 450 mm long with PTMT nuts, cistern colour shall be match WC colour, complete all as specified and as directed. Make:- Cera cat. No. B1010102 CIENA PREMIUM or its equivalent model in Parryware / Jhonson as approved by GE
S&F viterous china bowl urinal flat back, of size 375 x 390 x 590 mm Ivory, (Minimum) with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement etc complete all as specified and as directed. Make:- Cera cat. No. S4020112 CAPRIANA or its equivalent model in Hindware / Parryware as approved by GE
Corner Glass shelf, superior quality with CP tubular framing & brackets complete all as per sample. Make:- Jaquar cat. No. CAN-1173 or its equivalent model in Kohler / Cera as approved by GE
S&F in repairs of 5 - 6 mm thick bevelled edges high quality looking mirror fancy type fixed to wall with chromium plated screw with cup washers etc complete all as specified and as directed. Make:- Cera Cat. No. B3510149 or its equivalent model in Hindware / Parryware as approved by GE
S&F in repairs of single towel rail 600mm long fixed with chormium plated brass screws, complete all as specified and as directed. Make : Jaquar Cat No. AKP-35711P or equivalent in Kohler/ Cera as approved by GE.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors of suitable size complete all as specified and as directed .
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors of suitable size complete all as specified and as directed .
S&F 75 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and as directed.
S&F 110 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and as directed.
S& F in repairs stainless steel decorative type curtain rods of 22 to 25mm dia, complete all as specified and directed.
S& F in repairs stainless steel decorative type brackets suitable for holding 22 to 25 mm dia CP stainless steel curtain rod, purpose made trade pattern complete all as specified and directed.
S&F of stainless steel decorative finials (round type with mirror optic finish) trade pattern for decorative type curtain rods suitable for 22 to 25 mm dia curtain rods as per sample as in repairs with all fitting, complete all as specified and as directed by Engr-in-charge
Taking down chowkhats or frames with shutters (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Taking down steel window/ventilator, complete all as directed by Engg-in-charge.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F factory made box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete without glazing bars, complete all as specified and as directed by Engr-in-Charge.
S&F rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars barred iron doors; chowkhat, doors with MS sheet, ladders ;framed balusters walk ways railings framed work of water tanks and similar work conforming to Fe-290Gde E-165, complete all as specified & directed by Engineer-in-charge
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified & directed by Engineer-in-charge
S&F of 3mm thick ordinary quality sheet glass panes, fixed glazing with oil putty in square size not exc 0.5 Sqm in each pane, complete all as specified and as directed.
S&F of 3mm thick figured glass pin headed type, fixed glazing with oil putty in square size not exc 0.5 Sqm in each pane, complete all as specified and as directed.
S&F 35 mm thick second class hard wood factory made plain, framed, panelled shutters, with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and Style as per IS:1003 (Part-1), kiln seasoned and chemically pressure treated, including sand papering to obtain even and smooth surface/texture, complete all as specified and as directed.
S&F 30mm thick factory made 2nd class hardwood glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and as directed.
Refixing of shutters with chowkat in same opening exceeding 1.0 Sqm but not exceeding 2 Sqm each, including taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc. complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC ‘C’ channel having a wood grain printed PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing., complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick wood grain PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed.
S&F of aluminium anodized,tower bolt extruded section of size 150 mm long, including screws or bolts, nuts and washers to match the article, complete all as specified and as directed.
S&F of stainless steel butt hinges 100mm size, including screws or bolts, nuts and washers to match the article, complete all as specified and as directed.
S&F aluminum anodised handle extruded section of size 150mm long, including screws or bolts, nuts and washers to match the article, complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm with necessary fitting on aluminium window,ventilator & door shutter, complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth, including & over a coat of red oxide primer including preparation of surfaces, complete all as specified and as directed.
Preparation of old painted wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as directed.
M&L for 75 mm thick, PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in flooring, path, sub base & other similar work, complete all as specified and as directed.
S&F Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with gray cement & pigment, including & over 15 mm thick screed bed in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in kerb stone etc., (of any section as approved) with plain faces, including rounded or chamfered angles, weathering, throating etc., and setting in cement mortar 1:4 complete with joints to match, complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and as directed .
Returning filling in excavated soil, including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.50 mtr above the starting point, complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested suitable for 150 mm bore pipe, complete all as specified and as directed.
M&L for salt glazed stoneware drain pipes 150mm bore, grade 'A' laid in trenches and jointed in CM(1:1) including taking down old UNSV pipe, complete all as specified and as directed by Engr-in-Charge.
Demolition of stone / boulder masonry walling, built in cement mortar or cement lime motar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed, well bonded, bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed.
Extra over square rubble stone walling, Jodhpur type, regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and as directed.
M&L 5 cm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings cover stones templates etc not exc 2m in length punched dressed on face and along exposed edges self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and as directed.
Cutting chases in stone wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engg.-in-charge.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed
M&L for applying two coats of synthetic enamel paint on new concrete surfaces of any description over 10 cm width or girth, including preparation of surfaces, complete all as specified and as directed.
E/M ITEMS Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces, complete all as directed.
M&L point wiring using approved colour coding (Red , Black and Green for single phase circuits) as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 Volts grade, ISI marked, in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet (ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & sheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and as directed.
All as per serial Item No.108.00 above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and as directed.
All as per serial Item No.108.00 above but for one 3 pin socket outlet 5/6 Amps on the independent board, complete all as specified and as directed.
All as per serial Item No.108.00 above but for 16 Amps 3 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLS multi-stranded copper conductor with 2.50 Sqmm PVC insulated & FRLS multi-stranded copper conductor as earth wire complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 Volts, (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 Volts, (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, flush type, single pole, 2 in 1, 3 Pin, 5/6 Amps, 230 Volts, (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, flush type, single pole, 3 Pin 15/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F Electronic fan regulator, 120W, modular type, 2 module and connecting electrically, ISI Marked, complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated body, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, as in repairs, including taking down old u/s material complete all as specified and as directed. Make : Bajaj Cat No. BCLSB 20 WH or Equivalent in Philips/ Havells as approved by GE.
S&F lamp holder insulated body polycarbonate type with back plate, complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
Supply, fixing, testing & commissioning of LED street light fitting 45 Watt 230 V AC, IP-65 protection, single piece pressure die cast aluminium alloy housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and contror gear compartment with high voltage surge protection device upto 4.5 KV, Prewired including 1.6 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable, as in repairs, including taking down old u/s material complete all as specified Make : Philips/ Bajaj/ Havells
S&F in repair sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 6.00 Sqmm and one run of 4.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 6.00 sqmm cable with one run of 4.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
S&F Prewired distribution board (sheet metal enclosures) with suitable rated 200 Amps bus bar for Double door DB's of apporved gauge conforming to IS relevant, IP-43 protection, SPN 4 way, 240 volt, as in repairs, including taking down old u/s material, complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
S&F Vertical Distribution Board, double Door, suitable for 'A' Frame, 4 Pole MCCB 160A, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, as in repairs, including taking down old u/s material, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider Note : MCCB & MCB shall be measured and paid for separately.
S&F MCCB, 'A' Frame, thermal adjustable magnectic setting, Ics = 75% 36 kA, 415V, 160 Amp, 4 Pole with over load and short circuit protection, suiatble for item No.124.00, (ISI marked), as in repairs, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB single pole 240 volts rating from 5 to 30 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in repairs, including taking down old u/s materialcomplete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F RCBOs, 4 Pole, 300mA, 63 Amps, for earth leakage, overload & short- circuit protection, (ISI marked), as in repairs, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB single pole 240 volts rating from 63 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection,as in repairs, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
M&L in repairs for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron earth lead wire of size 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and fix exhaust fan, steel body, heavy duty, AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, including fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan, & making good to disturbed portion to match the existing surface etc., as in repairs, including taking down old u/s material, complete all as specified and as directed. Make : Havells/ Bajaj/ CG
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor, stranded conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Core 16 Sqmm nominal cross section in service connections, as in repairs, including taking down old u/s cable, complete all as specified and as directed.
Note:- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
SNEH CORPORATION
M/S KAUTILYA GARG
M/s Ajay kumar Garge
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .