| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.5 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹88.3 L+₹23.8 L (36.9%)Admitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S HIGHLAND ENGINEERING L1 | BHAT ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing and Commissioning of Centralized Medical Gas Pipe Line System Under PM care funds to be installed at 200-Bed (Covid-19 Hospital) Kurbathang Kargil as per Annexure "D" of the NIT. OXYGEN SYSTEM | |||||
| 1.10 | Main Oxygen Manifold 6x 6 cylinders with NRV's, Tail pipes and Middle frame | 2 | set | 30,100 ₹60,200 Lowest | 50,000 ₹1,00,000 |
| 1.20 | Fully - automatic Oxygen Control Panel (indigenous) with automatic changeover from Running Bank to Reserve Bank of cylinders and having non-halogenated polymer in the high pressure side of the primary regulators and 40 micron inlet filter | 1 | No | 1,11,500 ₹1,11,500 Lowest | 1,45,000 ₹1,45,000 |
| 1.30 | 5-cylinder Emergency Oxygen Manifold complete with tail pipe, NRV and Pressure Reducung System having non- halogenated polymer materials in the high pressure side of the regulator | 1 | set | 17,400 ₹17,400 Lowest | 43,000 ₹43,000 |
| 2.00COMPRESSED AIR SYSTEM | |||||
| 2.10 | Triplex air plant system (Consisting of 3 nos Air Compressors), Tank Mounted, each Receiver Capacity 500 ltrs, common Air drier, Pressure Reducing Unit etc. 3-Stage Breathing Air Filter as per specifications, | 1 | job | 6,60,000 ₹6,60,000 Lowest | 13,45,000 ₹13,45,000 |
| 3.00VACCUM SYSTEM | |||||
| 3.10 | 3 nos. rotary vane vacuum pumps with Receiver, Filters, Electricals, etc. as specified in the spec | 1 | set | 6,65,000 ₹6,65,000 Lowest | 6,75,000 ₹6,75,000 |
| 4.00COPPER PIPING AS PER EN 13348 | |||||
| 4.10 | Copper Pipe for Medical use with 12 OD X 1.0 mm | 120 | Meter | 600 ₹72,000 Lowest | 780 ₹93,600 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
29 Jun 2021, 2:00 pmClosed
EXECUTIVE EINGINEER MECHANICAL DIVISION KARGIL
OFFICE OF EXECUTIVE EINGINEER MECHANICAL DIVISION KARGIL OPPOSITE IOCL DEPT KURBATHANG
Supply, Installation, Testing and Commissioning of Centralized Medical Gas Pipe Line System and other allied accessories Under PM care funds to be installed at 200-Bed (Covid-19 Hospital) Kurbathang Kargil
2021_PWD_3461_1
ENIT06
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
25 days
2OO BEDDED HOSPITAL KARGIL
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
₹1.5 L
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
8 Jul 2021
22 Jun 2021
30 Jun 2021
22 Jun 2021
29 Jun 2021
22 Jun 2021
25 Jun 2021
Amount
Supply, Installation, Testing and Commissioning of Centralized Medical Gas Pipe Line System Under PM care funds to be installed at 200-Bed (Covid-19 Hospital) Kurbathang Kargil as per Annexure "D" of the NIT. OXYGEN SYSTEM
Main Oxygen Manifold 6x 6 cylinders with NRV's, Tail pipes and Middle frame
Fully - automatic Oxygen Control Panel (indigenous) with automatic changeover from Running Bank to Reserve Bank of cylinders and having non-halogenated polymer in the high pressure side of the primary regulators and 40 micron inlet filter
5-cylinder Emergency Oxygen Manifold complete with tail pipe, NRV and Pressure Reducung System having non- halogenated polymer materials in the high pressure side of the regulator
COMPRESSED AIR SYSTEM
Triplex air plant system (Consisting of 3 nos Air Compressors), Tank Mounted, each Receiver Capacity 500 ltrs, common Air drier, Pressure Reducing Unit etc. 3-Stage Breathing Air Filter as per specifications,
VACCUM SYSTEM
3 nos. rotary vane vacuum pumps with Receiver, Filters, Electricals, etc. as specified in the spec
COPPER PIPING AS PER EN 13348
Copper Pipe for Medical use with 12 OD X 1.0 mm
Copper Pipe for Medical use with 15 OD X 1.0 mm
Copper Pipe for Medical use with 22 OD X 1.0 mm
Copper Pipe for Medical use with 28 OD X 1.0 mm
Copper Pipe for Medical use with 38 OD X 1.0 mm
FACTORY DEGREASED ISOLATION VALVES FOR MEDICAL USAGE WITH BRASS ADOPTERS
1. Isolation Valve for 15 mm Copper Pipe i.e (1/2")
2. Isolation Valve for 22 mm Copper Pipe i.e (3/4")
3. Isolation Valve for 28 mm Copper Pipe i.e (1")
VALVE BOX (WITHOUT VALVES) FOR MEDICAL USAGE
1. Valve Box - 4 Gas Service (size 15mm X 15mm X 22mm) with NIST Connection &S.S.Valve for O2
DIGITAL ALARM SYSTEMS
1. 4 Gas Microprocessor Controlled Alarm With Digital Display
GAS OUTLETS
Double Lock with probe - Oxygen
Double Lock with probe - AirMedical Air Set
Double Lock with probe - Vacuum Set
SUCTION AND OXYGEN THERAPY
PRODUCT
Oxygen Flowmeter BPC (0- 15 LPM) with 600ml bottle Humidifier Set
Ward Vacuum Unit with Regulator and 600ml polycarbonate jar Set
High Pressure Tubing
BED HEAD PANEL
SITC Fully Automatic Voltage Regulator Duly Filled With Recommended Oil Upto Full Capacity. Type = Fully Automatic Servo Voltage Regulator Rating = 250 KVA Input Voltage Range (Phase To Phase) =270-460 V Output Voltage Range (Phase To Phase) =415±1% Output Wave Form = True To Input Input Frequency = 45-55 Hz Response Time = 10 Msec Correction Speed = 25-65 V/Sec Correction Method = Stopless Correction Cooling = Oil Efficiency = Better Than 98% Control Circuit = Fully Automatic Ic Based Solid Stat, Operation = Fully Automatic Suitability = Suitable For 3-Phase Unbalanced Supply Unbalanced Load Operating Temperature Ambient = -15oc To 45oc Above ADDITIONAL FEATURES = i)High and low voltage cutoff system. ii)Over load and short circuit protection iii) Single phase prevention system. iv) Phase sequence change protection. v) Earth fault protection. vi) High grade CRGO lamination. vii) Simple rugged construction. viii) 99.9% pure copper. ix) High efficiency. x) Negligible wave form and power factor distortion
Maintenance free earthling:- S.I.T.C. of long life maintenance free electrolytic earthling system with 10 feet vertical k type copper not less than 2”( 50.8mm) ID and not less than 0.08” (2.03mm) wall thickness ,which does not require manual addition of water .The system should be corrosion resistant pre- filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. Rated for high fault currents bas bar rated for 10KA, fault current bus bar connection type as “Terraweld” to withhold temperature of 7000C.The earthling port shall be designed and supplied with poly plastic port cover non conductive, environment friendly and lockable. The job includes excavation of pit, disposal of earth, installation of rods refilling with suitable earth and leveling copper strip etc.
Installation ofMain Electrical Panel: The main electrical control panel should be of required Amp. The panel should have automatic starter, over load protection, single phase preventer, timer assemblies, emergency stop buttons and indication lamps etc for successful operation of all the components of oxygen plant. All the above equipment should be integrated and controlled through a single electrical control panel
P/Laying Power/Control Copper Cables in Solid Copper Conductor in Single Core XLPE Insulated, PVC inner sheathed, unarmoured including lugs/thimbles of respective size. 01. 2.5-Sqmm=350-M 02. 6-sqmm =500-M 03. 95-Sqmm =300-M 04. 185-Sqmm=400-M
BHAT ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .