Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.9 LAccepted-AOC D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹29.0 L+₹5,862 (0.20%)Rejected-Finance 00 BALAJI ENTERPRISES NEW ROAD NEW ROAD RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹29.2 L+₹30,295 (1.05%)Rejected-Finance | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹32.4 L+₹3.4 L (11.8%)Rejected-Finance | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹32.7 L+₹3.8 L (13.0%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | 5 | Rejected-Finance Not L-1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Jun 2021, 6:00 pmClosed
Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR REPLACEMENT OF INTERNAL WIRING FITTINGS FIXTURES AT NAD TECHNICAL AREA UNDER AGE EM OF GE ND VISAKHAPATNAM
2021_MES_443241_1
8957/GEND
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE ND Visakhapatnam
₹80,000
Yes
31 Jul 2021
17 May 2021
15 Jun 2021
17 May 2021
9 Jun 2021
2 Jun 2021
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of suitable size including accessories fixed on wall/floor/roof, etc including provision of pressed mild steel terminal box with (surface/concealed) white modular cover plate and frame of suitable size for fixing modular switches, sockets, etc including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fittings & fixtures and making good disturbed sufaces complete all as specified and directed.
All as per item No. 2 above but suitable for one 5 Amps socket point on the same board
All as per item No. 2 above but point wiring with 2.5 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.
All as per item No. 2 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including Concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of pressed mild steel terminal box with (surface/concealed) white modular cover plate and frame of suitable size for fixing modular switches, sockets, etc including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for necessary cutting chases in walls / floors / ceiling of any description, pinning in making good to disturbed surfaces where required and pointing in cement mortar 1:3 and finished to match with existing finishes complete]
All as per item No. 6 above but suitable for one 5 Amps socket point on the same board
All as per item No. 6 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn in existing concealed / surface PVC conduit including provision of MS terminal box (surface/concealed) with white modular cover plate and frame including provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan / bell point / 5 Amps socket point controlled by one switch including taking down old point wiring with fittings & fixtures and making good disturbed surfaces to match with existing complete all as specified and directed.
All as per item No. 9 above but suitable for one 5 Amps socket point controlled by one switch on independent board
All as per item No. 9 above but suitable for one 5 Amps socket point on the same board
All as per item No. 9 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.
M & L for Point wiring with FRLS grade PVC insulated unsheathed multistranded copper conductor cable 1.5 Sqmm (nominal area) 1100V grade drawn through and including ERW steel conduit of size not less than 20mm dia including accessories fixed on wall/floor/roof, etc with MS terminal boxes made out of 2.0mm thick mild steel sheet including provision of FRLS grade insulated, unsheathed multistranded copper conductor of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for flame proof switches/sockets of any type for One light / fan point / Bell / 5A socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures and making good to the disturbed surfaces of wall / ceiling to match with existing finishes complete all as specified and directed.
All as per item No. 13 above but point wiring with 4.0 Sqmm (nominal area) suitable for one flame proof 15/16 Amps switch socket point on independent board complete all as specified and directed.
S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified
S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified
S & F switch socket combination multipurpose 3 pin, 5 Amps controlled by one 5 Amps switch complete all as specified and directed.
S & F switch socket combination, multipurpose, 2 in 1, 3 Pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 volts, complete all as specified and directed
S & F Switch Piano, flush type, single pole, One way, 5 Amps, 230 Volt complete all as specified.
S & F Switch Piano, flush type, single pole, One way, 15 Amps, 230 Volt complete all as specified.
S & F bell push piano flush type 6 Amps, 230V complete all as directed
S & F electronic fan regulator, socket type, upto 300 Watts complete all as directed
S & F modular switch 1 way, 6 Amps, 1 module
S & F modular switch 1 way, 16 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, omplete all as specified and directed.
S & F modular bell push flush type 6 Amps
S & F Calling bell, AC, 230 Volts, single pole
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
M & L for sub main wiring with 4 runs of single core 1100 volts grade, 10.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including Stove enamelled steel conduit of size 32/40mm dia and conduit accessories including provision of 1 run of 10.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 5 runs of 10.0 Sqmm cable and 1 run of steel conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, 6.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including Stove enamelled steel conduit of size 25mm dia and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm cable and 1 run of steel conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, 6.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, 4.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, 2.5 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 5 runs of single core 1100 volts grade, 10.0 Sqmm, PVC insulated, unsheathed, FRLS copper conductor cable drawn through and including suitable size surface PVC conduit and conduit accessories including provision of 1 run of 10.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring and making good disturbed surfaces complete all as specified and directed. [NOTE: 6 runs of 10.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
S & F in repairs GI powder coated louvers suitable for exhaust fans upto 600mm sweep complete all as directed. [Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height]
S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 4 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 8 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
S & F in repairs factory made sheet metal enclosure double door SPN MCB DBs (fixed flush to the wall), 12 way, 240 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
S & F in repairs factory made sheet metal enclosure double door VTPN DBs (fixed flush to the wall) with provision for MCCB, four Pole as incomer and outgoing as TPN, 6 way, 415 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed. [Note: MCCB shall be measured and paid seperately]
S & F in repairs factory made sheet metal enclosure double door TPN MCB DBs (fixed flush to the wall), 4 way, 415 Volts, IP-42 protection with 200 Amps rated bus bar with suitable size copper PVC sheathed cable for earth continuity and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
S & F in repairs Isolator, TPN, 100 Amps, 415 Volt, 125 KA, 50 Hz complete all as directed
S & F in repairs MCB, TPN, 63 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs MCB, TP, 63 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs MCB, TPN, 40 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs MCB, TP, 40 Amps, 415 Volt, rupturing capacity 16 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs MCB, SPN, 40 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs MCB, SPN, 63 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs MCB, SP, 6 to 32 Amps, 240 Volt, rupturing capacity 10 KA, 50 Hz, 'B' curve complete all as directed
S & F in repairs RCCB for earth leakage over load & short circuit protection DP, 40 Amps, 100mA, 240 Volts, AC supply complete all as directed
S & F in repairs RCCB for earth leakage over load & short circuit protection FP, 40 Amps, 100mA, 240 Volts, AC supply complete all as directed
S F in repairs MCCB, FP, 100 Amps, 415 Volts fixed type breaking capacity 16 KA complete all as directed
S F in repairs MCCB, FP, 200 Amps, 415 Volts fixed type breaking capacity 35 KA complete all as directed
S F in repairs MCCB, FP, 250 Amps, 415 Volts fixed type breaking capacity 35 KA complete all as directed
Taking down existing light fittings of any type LED light / security lights from any position and refixing the same in new/old location with new clamps, nuts, washers and PVC copper cable as required at site complete all as specified and directed by the Engineer-in-Charge.
Taking down existing ceiling fan of any type and sweep from any position and refixing the same in original / new location after necessary servicing, cleaning for dust, grease including replacement of minor spares such as bushes, bearings, canopy, capacitors, etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler and writing MES Nos on the fans complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
M & L for removing defective / burnt out winding of ceiling fans of any capacity and rewinding with super enamelled copper winding wire of suitable size complete all as specified and directed by the Engineer-in-Charge.
Taking down existing Exhaust fan / Air circulator / Pedestal fan / wall mounted fan of any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease including replacement of minor spares such as bushes, bearings, capacitors, etc as required at site and applying two coats of synthetic enamel paint (spray painting) including filling the cavities with filler including replacement of defective spares complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
M & L for removing defective / burnt out winding of Exhaust fan / Air circulator / Pedestal fan / wall mounted fan of any capacity and rewinding with super enamelled copper winding wire of suitable size complete all as specified and directed by the Engineer-in-Charge.
S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and minimum 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED tube light fittings, 2 feet long of 900 to 1000 lumens of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED Mirror light fitting of 7 Watt with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down existing light fittings of any type and making good to the disturbed surafces to match with existing complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED bulb 9 watts with pin type holder (PVC / Polycarbonate insulated body) with back plate complete all as directed
S & F Building Security light LED type of minimum 15000 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size fixed to walls/ceiling with necessary fixing arrangement including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Post top lantern for 360 degree indirect light with IP-65 protection, 40 Watts with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs weather proof IP-65 distribution board 4 modules of size 126x228x111mm suitable for fixing on any surface complete all as specified.
S & F Building Security light LED type of minimum 4500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F CMRI certified flame proof Weather proof LED tube light fittings of not less than 4000 lumens output, 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughened glass cover, electronic driver with all accessories internally prewired connecting with flexible copper conductor of size 1.5 Sqmm including taking down existing light fittings complete all as directed.
S & F CMRI certified flame proof Weather proof LED bulk head fittings of not less than 1500 lumens output, 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughened glass cover, electronic driver with all accessories internally prewired connecting with flexible copper conductor of size 1.5 Sqmm including taking down existing light fittings complete all as directed.
S & F CMRI certified flame proof Weather proof LED bulk head fittings of not less than 4000 lumens output, 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughened glass cover, electronic driver with all accessories internally prewired connecting with flexible copper conductor of size 1.5 Sqmm including taking down existing light fittings complete all as directed.
S & F CMRI certified flame proof Weather proof LED highbay fittings of not less than 6000 lumens output, 5700K, PF>0.95 with pressure die cast aluminium housing IP-65 protection heat resistance toughened glass cover, electronic driver with all accessories internally prewired connecting with flexible copper conductor of size 1.5 Sqmm including taking down existing light fittings complete all as directed.
S & F in repairs batten suitable for LED T8 lamps
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and dismantling old unserviceable earthing complete all as directed by the Engineer-in-Charge. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, Precast RCC 1:2:4, Type B-1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and dismantling old unserviceable earthing complete all as directed by the Engineer-in-Charge. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, Precast RCC 1:2:4, Type B-1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and dismantling old unserviceable earthing complete all as directed by the Engineer-in-Charge. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, Precast RCC 1:2:4, Type B-1 cover 40mm thick reinforced with 8mm dia CTD bars @ 75mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
S & F Earth continuity conductor or main earthing lead of 20x3mm copper strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified and directed.
S & F Earth continuity conductor or main earthing lead of 25x4mm GI earth strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified and directed.
S & F Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified and directed.
M & L for removing the old rusted steel DB (SPN/TPN) of any type and description including metering arrangements complete after dressing the incoming and outgoing cable and securing it properly and filling the cavity / blank space with brick masonry in CM 1:6 and rendering with CM 1:4 and finishing the surfaces with two coats of distemper over a coat of primer over thick layer of putty and refixing the DBs so as to flush with the wall complete all as directed by the Engineer-in-Charge
M & L for Servicing of rolling shutter / hanger door motor of 7.5 HP capacity by opening, cleaning, and rewinding the motor with appropriate gauge super enameled copper wire, varnishing with golden colour varinish, drying, greasing, replacement of insulating materials, sleeves, worn out shaft bush, condenser, bearings, chain link and sprocket, nuts & bolts, split pins and refixing the motor in original position, painting (two coats of existing colour) including testing and commissioning complete all as specified directed by the Engineer-in-Charge
S & F Starter for shutter motor of capacity 7.5HP DOL type suitable for rolling shuuter / hanger door motor two way revolving type (clockwise and anticlockwise both type) including taking down defective starter complete all as directed by Engineer-in-Charge.
S & F limit switch 10A-125, 250 or 480 Volts, AC suitable for rolling shutter / hanger door for 3 phase supply including taking down defective limit switch complete all as directed by Engineer-in-Charge.
S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified.
S & F in repairs Aluminium strip 25x3mm as roof conductors and down conductors buried in ground / fixed on wall with means of hylam sheet with epoxy based insulator and screws, bolts, nuts and lead washers complete all as specified and directed.
S & F in repairs Test point terminal box of size 200x100x100mm made of 2mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with test point terminal block made of gun metal or Phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws and secured to wall complete all as specified and directed.
Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 4 core 25 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
Supply, laying and testing LT XLPE insulated, PVC sheathed, bedded, armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Returning filling in, including spreading, levelling,watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
S & F GI tubing 40mm bore, light grade for cable protection laid in trenches / walls complete all as specified and directed.
M & L for cutting of road / hard standing for laying of cables / cable protection pipe and making good the disturbed portion in PCC 1:3:6, type C-1 using 20mm graded stone aggregate including removal of debris to a distance not exc 50m complete all as specified and directed.
S & F in repairs factory made flame proof IP 65 protection MCB TPN 8 way distribution board including one 63 Amps MCB as incomer and 12 Nos MCB SP 10 to 16 Amps with suitable size copper PVC sheathed cable for earth continuity, cable glands, mounting and fixing arrangements and making good disturbed surfaces in PCC / Brick work including plastering and finishes to match with adjoining wall surfaces complete all as specified and directed.
Balaji Enterprises
SAI ENGINEERING WORKS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
MVV Prasad
K APPAJI KUMAR AND CONSTRUCTIONS
Mavee Syndicate
S R CONSTRUCTIONS
BHARGAVI ENGINEERING CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .