Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹55,100 (0.51%)Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | ₹1.1 Cr+₹55,100 (0.51%) | L2 | Admitted-Finance |
| 3 | L3₹1.1 Cr+₹1.5 L (1.41%)Admitted-Finance | ₹1.1 Cr+₹1.5 L (1.41%) | L3 | Admitted-Finance |
| 4 | L4₹1.8 Cr+₹73.9 L (68.5%)Admitted-Finance D NO 39 12 27 1 3 MURALI NAGAR VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹1.8 Cr+₹73.9 L (68.5%) | L4 | Admitted-Finance |
| 5 | L5₹2.0 Cr+₹88.8 L (82.3%)Admitted-Finance | ₹2.0 Cr+₹88.8 L (82.3%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L2 | AARAV POWER CONTROLS L1 | aswitha engineering works L3 | UNITY PROJEKTZ L4 | M/s Jai Ganesh Engineering Solutions L5 | SANTOSH CONSTRUCTIONS L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix of LT cable end termination for cable sizes 400 Sq mm, 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends for the following sizes including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing/new all as specified and directed. | 80 | Each | 1,600 ₹1,28,000 Lowest | 2,400 ₹1,92,000 | 2,461.54 ₹1,96,923.08 | 3,500 ₹2,80,000 | 3,000 ₹2,40,000 | 2,800 ₹2,24,000 |
| 2.00 | Supply only copper bus bar links with PVC sleeves of rating 630 A to 2000 A complete all as specified and directed. | 290 | Kg | 1,200 ₹3,48,000 | 900 ₹2,61,000 Lowest | 950 ₹2,75,500 | 1,500 ₹4,35,000 | 2,000 ₹5,80,000 | 1,200 ₹3,48,000 |
| 3.00 | Supply and fix LT indoor junction box of size 2mtr length 01 mtr width 01 mtr height made out of 50x50x06mm angle and 75x40 mm base made in to two parts in removable condition fitted with bolt and nuts out side door of 3mm thick aluminium sheet FRP on the out side of the doors and painted with power coating in internal portion of doors and angular with copper bus bar of 2000 Amps capacity complete all as specified and directed by Eng-in-Charge.
(As per site suited, If any changes in dimensions, as built drawing to be submitted & work to be initiated after approval from concern only) | 2 | Each | 1,75,000 ₹3,50,000 | 30,000 ₹60,000 | 12,000 ₹24,000 Lowest | 2,35,000 ₹4,70,000 | 20,000 ₹40,000 | 1,85,000 ₹3,70,000 |
| 4.00 | Repair/ Mainteance of capacity 600 KVA Diesel generators for carrying out required Repairs and 6K Routine maintenance, removal and refixing of spare parts for the same after carrying out rapairs / servicing complete all as specified and as directed.
Notes: Supply only spare parts required shall be measured and paid separately under relevant items of Sch 'A'. | 1 | Each Job | 2,00,000 ₹2,00,000 | 2,50,000 ₹2,50,000 | 2,00,000 ₹2,00,000 | 3,50,000 ₹3,50,000 | 4,00,000 ₹4,00,000 | 25,000 ₹25,000 Lowest |
| 4.01 | Fuel System:
(a) Clean and calibrate injectors and record test pressures in service log. Also change injector inlet screen.
(b) Replace rocker cover gaskets
(c ) Adjust valve tappet clearances within limits and record in service log
(d) Replace fuel pump filter (screen and magnet)
(e) Calibrate PT fuel pump and record in service log | 1 | Each Job | 1,60,000 ₹1,60,000 | 1,45,000 ₹1,45,000 Lowest | 2,00,000 ₹2,00,000 | 1,95,000 ₹1,95,000 | 2,00,000 ₹2,00,000 | 1,55,000 ₹1,55,000 |
| 4.02 | Air System:
(a) Clean turbocharger, compressor wheel and diffuser
(b) Check turbo charger radial/ end bearing clearance in-situ.
Note: Renew O ring and Teflon gasket when turbocharger is opened for checking clearances | 1 | Each Job | 70,000 ₹70,000 | 58,000 ₹58,000 Lowest | 75,000 ₹75,000 | 68,000 ₹68,000 | 60,000 ₹60,000 | 60,000 ₹60,000 |
| 4.03 | Charge Air Cooler & Fresh Water Cooler:
(a) Clean the internal passages of charge air cooler and fresh water cooler coolant side using restore plus as laid down in operating manual
(b) Renew coolant in the system.
(c ) Inpsect charge air cooler air side and if required clean using hot water and pressure test upto 2kg/cm2. | 1 | Each Job | 2,00,000 ₹2,00,000 Lowest | 2,90,000 ₹2,90,000 | 2,75,000 ₹2,75,000 | 3,42,000 ₹3,42,000 | 3,00,000 ₹3,00,000 | 2,50,000 ₹2,50,000 |
| 4.04 | Damper System:
Check thickness of vibration damper at 0, 90, 180 and 270 degree positions.
(b) Replace damper if variation of the 4 readings exceeds 0.010 inch (0.25mm) or exceeds max allowable thickness.
(c ) Check to be undertaken in coupled condition. | 1 | Each Job | 50,000 ₹50,000 | 45,000 ₹45,000 Lowest | 81,290.77 ₹81,290.77 | 55,000 ₹55,000 | 45,000 ₹45,000 Lowest | 50,000 ₹50,000 |
| 4.05 | Safety Alarm:
Check all safety alarms and trips | 1 | Each Job | 50,000 ₹50,000 | 90,000 ₹90,000 | 1,08,387.69 ₹1,08,387.69 | 1,05,000 ₹1,05,000 | 15,000 ₹15,000 Lowest | 95,000 ₹95,000 |
| 4.06 | Cranking System:
Check crank end clearances with a dial indicator, attaching against damper Min of 0.13mm, Max of 0.51mm | 1 | Each Job | 9,000 ₹9,000 | 8,200 ₹8,200 | 14,937.69 ₹14,937.69 | 10,000 ₹10,000 | 12,000 ₹12,000 | 8,000 ₹8,000 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
9 Nov 2024, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT OF POWER SUPPLY SERVICE EQUIPMENT ALONG WITH SPARE PARTS AND ASSOCIATED ACCESSORIES OF PUMP HOUSE AND DRY DOCKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2024_MES_678258_1
8043/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE (I) DM, Visakhapatnam
₹2.2 L
Yes
12 Nov 2024
5 Oct 2024
11 Nov 2024
5 Oct 2024
9 Nov 2024
26 Oct 2024
Amount
Supply and fix of LT cable end termination for cable sizes 400 Sq mm, 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends for the following sizes including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing/new all as specified and directed.
Supply only copper bus bar links with PVC sleeves of rating 630 A to 2000 A complete all as specified and directed.
Supply and fix LT indoor junction box of size 2mtr length 01 mtr width 01 mtr height made out of 50x50x06mm angle and 75x40 mm base made in to two parts in removable condition fitted with bolt and nuts out side door of 3mm thick aluminium sheet FRP on the out side of the doors and painted with power coating in internal portion of doors and angular with copper bus bar of 2000 Amps capacity complete all as specified and directed by Eng-in-Charge. (As per site suited, If any changes in dimensions, as built drawing to be submitted & work to be initiated after approval from concern only)
Repair/ Mainteance of capacity 600 KVA Diesel generators for carrying out required Repairs and 6K Routine maintenance, removal and refixing of spare parts for the same after carrying out rapairs / servicing complete all as specified and as directed. Notes: Supply only spare parts required shall be measured and paid separately under relevant items of Sch 'A'.
Fuel System: (a) Clean and calibrate injectors and record test pressures in service log. Also change injector inlet screen. (b) Replace rocker cover gaskets (c ) Adjust valve tappet clearances within limits and record in service log (d) Replace fuel pump filter (screen and magnet) (e) Calibrate PT fuel pump and record in service log
Air System: (a) Clean turbocharger, compressor wheel and diffuser (b) Check turbo charger radial/ end bearing clearance in-situ. Note: Renew O ring and Teflon gasket when turbocharger is opened for checking clearances
Charge Air Cooler & Fresh Water Cooler: (a) Clean the internal passages of charge air cooler and fresh water cooler coolant side using restore plus as laid down in operating manual (b) Renew coolant in the system. (c ) Inpsect charge air cooler air side and if required clean using hot water and pressure test upto 2kg/cm2.
Damper System: Check thickness of vibration damper at 0, 90, 180 and 270 degree positions. (b) Replace damper if variation of the 4 readings exceeds 0.010 inch (0.25mm) or exceeds max allowable thickness. (c ) Check to be undertaken in coupled condition.
Safety Alarm: Check all safety alarms and trips
Cranking System: Check crank end clearances with a dial indicator, attaching against damper Min of 0.13mm, Max of 0.51mm
Piston Liner System: For 1710/28GC1 engines - Undertake inspection of two representative pistons liners and bearings of the engine. Inspection of balance liners and bearings is to be scheduled based on inspection report of the two sample liners
Supply only the following spare parts as required shall be measured and paid separately under relevant items of Sch'A' during 6K Routines and servicing of 02 in Nos Capacity of 600 KVA Diesel Generators all as specified and directed.
GASKET SETS:
KIT3240239 Gasket Set
3081076 Gasket, Exhaust Manifold
HOUSING THERMOSTAT:
135675 Thermostat
186780 Seal, Thermostat
3017278 Hose, Plain
4950440 Clamp, Hose
3033215 Gasket, Thermostat Housing
INJECTOR:
KIT2865767 KIT, Barrel Plunger & Cup
193736 Seal, O Ring
166009 Spring, Compression
167157 Ball, Check
173086 Gasket, Injector
174299 Retainer, Screen
203426 Pin, Roll
3054999 Screen, Filter
3045047 Plug, Injector Orifice
185138 Retainer, Injector cup
3031137 Clamp, Injector
3028279 Screw, Twelve point Cap
191916 Link, Injector plunger
173085 Plug, Threaded
TURBOCHARGER:
3545627 KIT, Repair HX50
3709749 Gasket, Turbocharger
3519763 Gasket, Turbocharger
3081053 Hose, Plain
3892347 Clamp, T Bolt
3042353 stud, Double End Plain
219138 Nut, Regular Hexagon
3002991 Clamp, V Band
LUB OIL COOLER:
3010617 Seal, O Ring
172723 Gasket, Lub Oil CLR HSG
3010157 Seal, O Ring
122981 Seal, O Ring
COOLING SYSTEM:
4926654 Inhibitor, Corrosion 10 Liter
AX1013359 Radiwash_3LTR
WATER PUMP:
4911528 Pump, Water
123078 Gasket, Water Pump
3011230 Gasket, Water Pump
3040377 Belt, V
FILTERS:
3238204 Element, Lub Oil Filter
3238493 KIT, Fuel filter and ring
3879488 KIT, Super Bypass Filter Elem
3010937 Seal, O Ring
4055279 Element, Air Cleaner
4055280 Element, Air cleaner
3231787 Separator, Fuel Water
3040817 Seal, O Ring
129859 Elbow, Male Union
3872813 Indicator, Restriction
BREATHER:
255180 Breather, Crankcase
FUEL PUMP:
KITBM68356 Gasket Governor Set
212601 Shaft, Fuel Pump Drive
129888 Seal, Rectangular Ring
3042542 Seal, O Ring
3865398 Seal, O Ring
3867393 Screen, Filter
3033740 Valve, Check
3006550 Carrier, Governor Weight
S 16052 Bearing, Ball
3017993 Valve, Shutoff
154087 Seal, Rectangular Ring
3046200 Spider, Jaw Coupling
INTERCOOLER:
3077201 Gasket, AFT Housing
195952 Seal, O Ring
3033215 Gasket, Thermostat Housing
CYLINDER BLOCK:
KIT3803471 Set Piston Ring
215090 Eal, Rectangular Ring
3032874 Seal, O Ring
200600 Bearing, Connecting Rod
Serving & fixing of Numeric based Electronic Digital Display for Local and Remote areas by providing Percentage Valve Position Indicating Instrument System to Butterfly Valve (BFV) of 1800mm dia at SDD Pump House by providing all the necessitate fasteners with proper base and holding provisions near by the Gear Box Assembly and Actuator unit without disturbing the existing System. Note: Supply only spare parts required shall be measured and paid separately under relevant items of Sch 'A'
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. mm 3½ core complete all as specified and directed by Eng-in-Charge.
Supply the following mandatory spares as required shall be measured and paid separately under relevant items of Sch 'A' during Installation of Numeric based Electronic Digital Display for Local and Remote areas by providing Percentage Valve Position Indicating Instrument System to Butter Fly Valve (BFV) of 1800mm dia at SDD Pump House for specified schedule
Set of 24V DC Proximity Sensors/ Potentio meter unit along with modified Printed Circuit Board accommodate on the existing 1800mm dia BFV valve Gear Box connected e-pack Actuator without effecting the existing operating parameter conditions
Compactable Panel Board of size (LxWxH) 400x300x200 mm or suited to site condition as directed by Engineer In-Charge/ User Department (As Built drawing approval to be taken prior commencing the work if the standard dimensions were changed)
A min of 4 to 7-inch Local Display unit along with all connected associated accessories includes Signal Isolators, control wirings, Raw Power provisions, insulated separators, cords, ferules etc. showing the Percentage Indication of Butterfly Valve position
For Remote Display, Suitable Analog/ Digital I/O modules with sufficient channel points to be catered and made provision to access the signal to SLAVE/ MASTER PLC panel to Display on SCADA System and proving in SCADA system is sole responsibility of user department and requisite technical support/ data backup is provisioned by firm itself
Power Supply MCB, 220 V along with Power cord and control wiring in Local Unit
Local Remote Display along with sufficient accessories suitable to existing site and to be fitted in existing compact panel if any available to seen by the Duty Watch In-Charge for the indication of the 1800mm dia Butterfly Valve's position in percentage values
Junction Box of 220V
CAT cable
Power Supply protection 220V, 50 Hz, MCB
8 Core, 0.5 sqmm Armoured control cable laying from SDD pump house to SCADA control room/ Duty watch room of SDD Office space
Programmed, calibrated Ethernet Switch along with all cable and connected accessories are to be provisioned on existing PLC/ SCADA panels if required. The physical value of existing 1800mm dia Butterfly Valve through Gear Box is to be proven by Local/ Local Remote/ Remote Numeric Instrument system in terms of Percentage Valve
M/S SRI VENKATA BHAVANI CONSTRUCTIONS (BID ID -3152835)
aswitha engineering works (BID ID -3156041)
UNITY PROJEKTZ (BID ID -3161313)
M/s Jai Ganesh Engineering Solutions (BID ID -3161669)
SANTOSH CONSTRUCTIONS (BID ID -3161682)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
8043tender.pdf
Tender Documents • 1.13 MB
BOQ_758667.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .