Loading…
Loading…
Tender ID
Tender Value
₹21.4 Cr
EMD Value
₹21.4 L
Closing Date
30 Apr 2026, 5:00 pmClosed
Deputy Municipal Commissioner
SALVAV WATER SUPPLY PROJECT: VAPI MUNICIPAL CORPORATION PHASE 2.
275989
09/WSS/2025-26
Open
Civil Works - Water Works
Works
Vapi
16 documents required · 16 mandatory
₹21,240
Municipal Corporation City of Vapi
₹21.4 L
31 Mar 2026
31 Mar 2026
31 Mar 2026
30 Apr 2026
31 Mar 2026
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
BID DOCUMENTS FOR
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN &
CONSTRUCTION OF ELEVATED SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION
NETWORK, PROVIDING, SUPPLING, ERECTING & TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF
HOUSE CONNECTION & RCC ROAD REINSTATEMENT & SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK
LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR VAPI MUNICIPAL CORPORATION, DISTRICT: VALSAD.”
SR NO SCHEDULES NAME OF WORK AMOUNT (RS.)
1) SALVAV WATER SUPPLY SCHEME
1 SCHEDULE - B1 GRAVITY MAIN PIPELINE
2 SCHEDULE - B2 DESIGNING & CONSTRUCTING RCC ELEVATED SERVICE RESERVOIRS (Capacity :10 LL & 24 mt Height)
3 SCHEDULE - B3 SUPPLYING, ERECTING, TESTING & COMMISSIONING OF PUMPING MACHINERIES
4 SCHEDULE - B4 HEADWORK DEVELOPMENT
5 SCHEDULE - B5 CONSTRUCTION OF HOUSE CONNECTION- 2367 Nos.
SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK
6 SCHEDULE - B6
LOCATION FOR SALVAV WATER SUPPLY
7 SCHEDULE - C Operation & Maintenance (For 5 Years)
Total Amount in Rs.
Total Amount in Rs.
I / We am / are willing to carry out the work at…………………………………… % above / below percent/at par (should be written in figures and words) of the
estimated rates mentioned above . Amount of my/ our tender works out as under.
* Estimated amount * Estimated amount
Put to tender Rs …… Put to tender Rs ……
Deduct :....... % below Rs……… Add :....... % above Rs………
Total Rs…………. Total Rs………….
* ( Please strike out whichever is not applicable ).
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF ELEVATED
SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING, SUPPLING, ERECTING &
TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD REINSTATEMENT & SITC WORK OF
INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR VAPI MUNICIPAL
CORPORATION, DISTRICT: VALSAD.”
SCHEDULE - B1: GRAVITY MAIN PIPELINES
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.1: Providing and supplying D. I. K-7 grade pipes for following nominal bore diameter with internal cement mortar
lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance
1 to departmental stores, stacking etc. complete. (IS 8329-2000).
Item No.2: Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as
per BS-EN-545/1995 Class-A series K12 suitable for use with DI pipes manufactured as per IS:8329/1994 delivery of specials is to
be made to VPMC store or site of works any where in Gujarat including all taxes, loading, unloading, carting, stacking,
2 insurance, inspection charges, octroi etc. complete. (With external bitumen & zinc coating & internal cement mortar lining)
Up to 300 mm Dia.
2a Above 300 mm Dia. 5318.91 Kg 158.00
Item No.2: Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as
per BS-EN-545/1995 Class-A series K12 suitable for use with DI pipes manufactured as per IS:8329/1994 delivery of specials is to
be made to VPMC store or site of works any where in Gujarat including all taxes, loading, unloading, carting, stacking,
2 insurance, inspection charges, octroi etc. complete. (With external bitumen & zinc coating & internal cement mortar lining)
Socket & Spigot Type Up to 300 mm Dia.
2a Above 300 mm Dia. 9036.38 Kg 151.00
Item No.3: Providing and supplying ISI mark CI D/F Sluice Valves as per IS : 14846 (Latest Edition )of following class and
diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading,
3 conveyance to departmental stores, stacking etc. complete.
PN-1 With hand/wheel cap operated (Alt-1 type long body)
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.4: Providing and supplying C. I. Temper proof Air valves with ss 304 Float gun metal- nozzle of approved make &
quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection
4 charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
Air Valves Double Acting (DS2)
Item No.5: Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and strutting if
required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up
to all required lead cleaning the site etc. complete for all lifts and strata as specified.
5 For 0 to 1.5 m :
In all sorts of soil and soft murrum
5a In hard murrum,boulders,incl. Macadam road 9674.75 Cu.m 155.25
5b Soft rock 9673.75 Cu.m 187.45
5c In Hard rock 5804.25 Cu.m 427.80
For 1.5 to 3.0 m :
In all sorts of soil and soft murrum 437.25 Cu.m 112.70
5e In hard murrum,boulders,incl. Macadam road 524.70 Cu.m 170.20
5f Soft rock 437.25 Cu.m 205.85
5g In Hard rock 349.80 Cu.m 446.20
Item No.6: Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various
classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge
6 including hydraulic testing etc. comp.
6i 600 mm dia 83.00 Rmt 464.60
Item No.7: Lowering, laying and jointing in position following C. I. / D/F Sluice valves including cost of all labour, jointing
material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.
Item No.8:Lowering, laying and jointing in position following C. I. / D/F Air valves including cost of all labour, jointing
material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.
(double ball Flanged )
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.9: Construction of valves chambers in brick or bela stone masonry, locally available in CM 1:6. Foundation concrete
150 mm thick in CC 1:4:8 of trap metal size 25 mm to 40mm thick, inside cement plaster in CM 1:3 and cement pointing outside
in CM 1:3 and top cover of precast RCC slab 100 mm thick (with key hole in two parts, each with handles or MS bar etc.
9 complete as given size) up to 1 mt. depth from GL to pipe invert level incl. complete civil works with 23 mm thick brick
masonry wall in CM 1:6 With precast slab in two parts 15 mm-
SV & ScV. Chamber - 0.6 x 0.6 x 1.0 m (For valves of 50, 65, 80, 100, 125 & 150 mm dia.)
9a Air Valve Chamber - 1.3 x 1.3 x 1.0 m (For 40 to 200 mm dia.) 81.00 No. 13053.65
Item No.10: Extra depth of Valve chamber beyond 1.00 mt. depth.
SV & ScV. Chamber - 0.6 x 0.6 x 1.0 m (For valves of 50, 65, 80, 100, 125 & 150 mm dia.) 1.10 mt. 3767.40
10a Air Valve Chamber - 1.3 x 1.3 x 1.0 m (For 40 to 200 mm dia.) 39.15 mt. 6996.60
Item No.11: Thurst Block : Providing and Casting in situ C.C. for Thrust Block in grade M-20 (Proportions as per mix design or as
per table 9 of IS456 2000 in masses by weight batching) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC
11 work, including scaffolding centring, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height
etc. complete for Thrust Block work. (excluding cost of reinforcement)
Footing for column or foundation ( with form work)
Item No.12: Reinforcement for Thrust Block : Supplying cutting, bending, binding and placing in position steel as per plan and
design and as per ISS 2502 including cost of steel and binding wire for structures only including lift up to 6 meter height or
depth below G.L., Do-Thermo mechanically treated (TMT) bars Fe-415 grade for all diameters.
Item No.13: Refilling the pipeline trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a
radius of 3 km. 38117.00 Cu.m 25.30
Item No.14: RCC Road Reinstatement : Reinstatement of roads with RCC where pipe crossing the asphalt road / RCC road /
industrial area / residential area. the Work including excavation, dressing, formwork, curing etc. completed and making a base
14 for road, 100 mm thick PCC in M10 grade of concrete, and Providing and laying 150 mm thick RCC M15 grade concrete,
Providing TMT bars FE-415 reinforcement for RCC work including bending, binding and placing in position complete.
Asphalt Road Reinstatement : of asphalt roads with 150 mm sand, 200 mm spools, 150 mm black trap metal (25-40 mm size),
150 mm aggregate (6-12 mm), quarry dust as inert material, watering, ramming with roller, tack coat 1 kg/ sqm, pre-mix
14a carpet 50 mm and seal coat 6 mm of bitumen 80/100 over refilled soil of at least 200-300 mm on top of pipe (depending upon
minimum cover of 0.9 m to 1 m depending upon topography) 8153.00 Sq.m 704.78
Item No.15: Culvert crossing.- Construction of RCC support for culvert crossing at various location on pipeline route. Work
including excavation of pits in all type of strata, 100 mm thick PCC in M10 grade concrete, Providing and casting RCC Column
and Footing in situ mass cement concrete in grade M-15 ( proportions as per mix design or as per table 9 of IS:456-2000 ) RCC
work, including scaffolding centring, formwork, needle vibrated consolidation, curing complete up to 6 m depth or height with
15 centring and shuttering etc. complete. Supplying cutting, bending, binding and placing in position steel as per plan and design
and as per ISS 2502 including cost of steel and binding wires for reservoirs / structures only including lift up to 6 m height or
depth below GL for all diameters. Supply, and installation of 8 mm thick MS clamp for pipe anchorage with required nut bolts
and 3 mm sacrificing plate at RCC column and bottom of pipe etc. completed as per drawing and minimum BoQ.- RCC Support
Total for Schedule-B1(Rs.) =
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF ELEVATED SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING
DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING, SUPPLING, ERECTING & TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD REINSTATEMENT & SITC
WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR VAPI MUNICIPAL CORPORATION, DISTRICT: VALSAD.”
SCHEDULE - B2: DESIGNING & CONSTRUCTING RCC ELEVATED SERVICE RESERVOIRS
10 LL ESR (Zone - 2), 24 mt. Staging Height at Salvav (Near Shree Bhavani Mata Mandir)
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.1: Designing structurally (and aesthetically) complying provisions of relevant Indian standards and constructing RCC Elevated service Reservoir of the following capacity and height , using latest Soil Investigation Report
of proposed site , Seismic zone, Wind speed Zone. Including (1)Container shape any suitable type(or as specified), (2) Staging consisting of column brace trestle / shaft / combination column- brace trestle and shaft as
appropriate(or as specified) and (3) Appropriate foundation system. This includes excavation in all types of soil strata(including hard rock) including dewatering if required, Filling with the selected excavated earth (excluding
rock), Providing & filling rubbles and pano send 300mm thick below PCC, casting 100 mm thick P.C.C. levelling course in M-15 , Refilling the pit with proper soil and disposing of the surplus stuff at all required lead. (4)This will
also include 20mm thick cement plaster in CM 1:2 with approved water proofing compound all over inside container (i.e. walls, base, top slab/dome bottom etc. all), 150 mm wide PVC water stopper of approved quality shall
be used, 10 cm x 10 cm size quarter round vata in cement mortar 1:1 including shall be provided (5) All types of labour & material charges of lowering , laying, erecting / hoisting & joining of pipe assembly of Inlet, Outlet,
overflow, washout and bye pass arrangement as per hydraulic design are including. (6) Providing and fixing of any accessories(specified), CI Manhole frame and covers, water level indicator , lightening conductor, GI Pipe railing
around walk way, at roof level, at gallery and around landing of inside shaft, Adequate cowl type ventilators or lantern type ventilator with stainless steel jali. (7) Scope of work includes constructing RCC spiral staircase with
adequate tie beams, staircase footing ,Rcc chambers for valves. ventilating shaft and ventilators as well as door in shaft, SS grating to be provided to outlet pipe (inside container) for safety.(8) including Providing and applying
2 coats of Epoxy paint of approved make to concrete surface for RCC ESR (inside the container) (as specified) and Providing & applying two coats of weather shield max paint for outside to the whole structure. (9) Providing,
mixing, laying 40mm thick IPS topping (1:1.5:3 - 1 cement : 1.5 sand : 3 stone aggregate 4.75mm and below) by volume on bottom dome of container, above top dome slab and on precast steps as per IS: 2581 with mixing of
water proofing compound (10) Painting letters with enamelled paint for capacity of reservoir with size of letters 45 cm. height and 75 mm width etc. On top of ESR (11) It also includes satisfactory water tightness test as per
relevant I.S. Code and painting name of scheme & capacity on the tank as per direction of engineer in charge. List of Indian Standards for design of ESR: The structural design of GSR shall be in accordance with provisions
relevant I.S standards: (1) I.S. 3370 part I & II 2009 or Its latest revision. (1.1) I.S. 3370 part III & IV 1965 or Its latest revision. (2) IS 456-2000 or Its latest revision. (3) IS 11682- 1985 or Its latest revision. (4) IS 1893-2002 part I to
V or Its latest revision. (5) IS 13920-1993, or Its latest revision. (6) IS 875 part I to III,1987 or Its latest revision. (7) IS 11089- 1987 or Its latest revision. General specifications: (1)The Min. concrete grade for RCC shall be M :30.
Proportion of concrete ingredients shall be as per Mix design using weigh batching. (2)CRS Fe-500 bars conforming to IS1786 (latest revision) and mild steel reinforcement (yield strength 2600kg/cm2) confirming to IS:226 shall
be used as per detailed specification. (3)In case of column –brace trestle type staging having more than 6 columns internal horizontal bracing is obligatory. One bracing shall be at foundation level in case of Individual footings.
(4)Min. size/ thickness of various components shall be provided as per design criteria/specifications/IS Code ( or as per std. practice). Capacity of the ESR shall be considered excluding free board. (5)Minimum dimensions
specified for various components in tender data /specifications should be provided. (6)The Safe bearing capacity (SBC) /allowable pressure on soil shall be referred from latest SBC test report or tender datasheet. During
1 execution If poor soil strata or ground water table is encountered, the SBC shall have to be re ascertained and the design should be revised accordingly. (7) Maximum spacing between horizontal bracings shall be 5 m (storey
height). (8)The BB Masonry cabin with MS door shall be constructed when spiral staircase is outside the staging.
(9) RCC Staircase/ MS Staircase shall be provided and fixed for access to roof when height of roof from G.L. is up to 10 m. For ESR having more than 10 m height proper RCC staircase or suitable RCC spiral staircase shall be
constructed. Railing should be provided through out the staircase and around the top ring beam. Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 at staircase shaft
platform and plinth area. 10) For ESR-having staging height more than 15 m the spiral staircase shall be provided inside the staging with effective tie beams in more than one direction. providing and construction of Brick work
using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 at outer side of esr and panel cum staff room at bottom of ESR. and providing shutter and door as per specified
in dwg. (11) Water level indictor shall be provided and fixed, Ultra Sonic Level Transmitter level indicator (as specified). (12)The rate shall include providing and fixing MS pipes with epoxy coating to inside pipe line and
Providing and applying outer coating of approved brand non toxic anticorrosive Epoxy paint with zinc rich primer, specials, and Providing and supplying and fixing of CI D/F Electric actuator operated Butterfly Valves with tail
piece as per IS:13095 (Latest Edition) for inlet, outlet , wash out, over flow and bye pass arrangement. The scope of work includes constructing supporting RC pillars, erecting, laying ,fixing and joining pipes and specials etc up
to 5m length from face of staging (outer most column). (13) DI pipes/MS & specials shall only be used. (14) The rate shall include cost of dewatering during execution making all arrangement with any dewatering technique.
(15) The structure shall be designed properly for uplift due to Ground water table specified in data or GWT encountered during execution. No extra payment shall be paid for the same. (16) Effective curing shall be carried out
as per specifications. Providing and supplying safety hanging net of appropriate capacity / dia. of rope and of suitable nylon quality which can withstand any impact of human being etc. (17) Agency shall engage qualified (at
least graduate)consulting engineer for designing the structure and he/she shall visit the site for guidance of work at all levels (i.e. below foundation, up to GL, above GL for all lifts up to container).Taking photograph of work in
progress and submit with each R.A.Bill. Photograph shall cover detail of location of the activity of work in progress. (18) 75 % part rate shall be payable for Concrete, Reinforcement and Plastering items of container until
satisfactory hydraulic testing for water tightness is performed as per tender condition. Till then the work shall be treated as incomplete. Above conditions / general specifications Sr. No. 1 to 18 are part and parcel of tender
(contract) and prevail over other provisions in tender. To be designed as per Seismic Zone
10 LL ESR (Zone - 2), 24 mt. Staging Height at Salvav
Total for Schedule-B2(Rs.) =
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF ELEVATED
SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING, SUPPLING, ERECTING &
TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD REINSTATEMENT & SITC WORK OF
INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR VAPI MUNICIPAL
CORPORATION, DISTRICT: VALSAD.”
SCHEDULE - B3: SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF PUMP SET WITH PIPING, ACCESSORIES & ELECTRICAL EQUIPMENT
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.1: SUBMERSIBLE TYPE PUMPSET
Supply, installation, testing & commissioning of Submerged Submersible pump sets with suitable for working on three phase,
Hz±3%,415V±10% AC supply, suitable RPM with 3 core flat copper cable from pump to starter panel with cable end terminations,
all supports, clamp, pipe fittings, mechanical seal, bearing bush, strainer, pump sensors and other protection, pump control
unit etc. suitable construction of foundation/ installation device with cable length from pumps to panels & of following Material
1 of Construction:
M.O.C :- Casing : CI, Impeller : SS CF8M, Wearing ring & bearing bush : Bronze, TC Mechanical seal, CS/SS bearing, SS shaft with
sleeve, SS strainer & MS motor body, Fasteners : SS 316L, Guide Rail : SS 316, Lifting Chain : SS
Capacity of pump - 17358 lpm & 17 m. head (75 kW/ 100 HP) - 2 working + 2 standby - 1. Ex 50 LL CWS at Salvav to Ex 75 LL CWS
Capacity of pump - 5517 lpm & 40.5 m. head (55 kW/ 75 HP) - 2 working + 2 standby - 2. Ex 50 LL CWS at Salvav WTP to JN A
(For Zone 1 & 2 Proposed ESR, 20 & 10 LL) 4.00 Set 1148527.00
Item No.2: Manufacture, Supply & Delivery of Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm)
M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/ amendment for following thickness
outside diameter at VpMC store or site anywhere in Gujarat State including Lowering, laying, jointing & welding in correct
position to correct line & level M.S.Pipe with outside & Inside lining/Epoxy paint on pedestal or chairs upon prepared or
2 prepared bedding in trenches the rates include conveyance from store to site of work loading, unloading conveyance to
Department stores, stacking etc. complete including all taxes, insurance, transportation, freight charges, octroi, inspection
charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete.
406.4 mm Dia. (6.3 mm Thick)
2a 1016 mm Dia. (8.8 mm Thick) 12.00 Rmt. 16504.00
2b 219.1 mm Dia. (4.5 mm Thick) 40.00 Rmt. 1932.40
2c 610 mm Dia. (6.3 mm Thick) 12.00 Rmt. 7211.05
Item No.3: Butter Fly Valve : SITC of Electrically Gear operated ISI mark CI D/F Butterfly Valve as per IS 13095, PN 1.0 with
sleeve of EPDM & disc, shaft & internal parts of SS 410 along with gaskets and all other necessary hardware etc. of
3 following diameter including all taxes, insurance, transportation, freight charges, Inspection Charges loading unloading,
conveyance to pump house stacking, security etc. complete as per IS and Specification.
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.4: Reflux Valve : Providing and supplying ISI mark CI D/F Reflux Valves as per IS:5312 (Latest Edition) of following class
and diameter including Lowering, laying & jointing in position following Reflux Valve including cost of all labour, jointing
material, including nut bolts and giving satisfactory hydraulic testing etc. complete. including all taxes, insurance,
4 transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc.
Item No.5: Air Cushion Valve with Cast Iron Body : Providing, supplying, lowering & laying C. I. Air cushion valves of approved
make & quality of following class and diameter including Lowering, laying & jointing in position following Air Valve including
cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. including all
5 taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental
stores, stacking and including cost of all labour, jointing material including nut bolts and giving satisfactory hydraulic testing
Item No.6: Supply, installation, testing & commissioning of flange ends Expansion Bellow as per EJMA standards of overall length
of minimum 300 mm, designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC &
pressure ratings.
6 MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS
1538 / IS 6392 ) & Limit Rods & Nuts: CS - IS
400 mm Dia. : PN 1.0 - On Delivery 4.00 No. 16500.00
Item No.7: MS Specials - Manufacturing, Supply, Delivery of M.S. Specials from MS plate of 5.6 mm thick confirming to relevant
IS including all taxes, duties, insurance, transformation, freight, octroi, inspection, loading, unloading, convey to site, stacking
7 etc. compete.
Flanged Ended - 1. Ex 50 LL CWS at Salvav to Ex 75 LL CWS at Chharwada 3960.00 Kg. 98.00
7a Flanged Ended - 2. Ex 50 LL CWS at Salvav WTP to JN A (For Zone 1 & 2 Proposed ESR, 20 & 10 LL) 1220.00 Kg. 98.00
Item No.8: Design , Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Guage, +1& accuracy, Direct bottom
1/2" NPT (M) process connection, IP 67, Glycerine filled, SS304 case with Bayonet Type Bezel, SS316 L Bourdon Tube, SS316
8 movement material, Aluminium dial with black graduation on white background, Micro Zero adjustable pointer, neoprene
gasket, Blow out disc, shatter proof glass, SS tag plate as per IS 3624. - 0 to 1 Kg/cm2.
150 mm dia. - 1. Ex 50 LL CWS at Salvav to Ex 75 LL CWS at Chharwada No. 1727.00
8a 100 mm dia. - 2. Ex 50 LL CWS at Salvav WTP to JN A (For Zone 1 & 2 Proposed ESR, 20 & 10 LL) 5.00 No. 1686.00
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.9: Full Bore Electromagnetic Flow Meter- Regular Power operated: Design, Supply, Installation, Testing, Commissioning
of Full Bore Electromagnetic flow meter with factory calibrated, Regular Power Operated, flanged connection, Flow sensor,
Indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardware's, etc
complete as per following specifications:
1. Flow Meter / Sensor : DC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard,
SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding
Electrode, Neoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive
Paint Coil Housing with Junction Box, CS flanges.
2. Flow Transmitter / Converter (Remote Field Mounted) : Microprocessor based, Modular design, 2 line LCD for indication of
actual flow rate, forward, reverse, sum totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity, 4 to 20 mA with
HART/Modbus output, one scalable pulse, one status output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with
Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor
to transmitter communication etc. along with wall mounted/ stand mounted cabinet.
On Header Pipe - 700 mm NB
9a On Header Pipe - 350 mm NB 1.00 No. 185900.00
Item No.10: EOT Crane : Providing & erecting single girder type fully electrically operated E.O.T crane with electrically
operated hoist, class II duty, geared travelling trolly with seven mts. Lift complete with long travel rail track (40 mm sq. Bar),
moving or cross girder, all three motions electrically operated by suitable rating motor IP 54, control panel & down control
block, brake, safety device, cables from motor to starter panel & other required accessories & tested as per IS Specifications. -
Span - 9.00 m, travel - 12 m. & Lift - 10 m.
3 Tonnes capacity 1.00 No. 534187.50
11 Item No.11: Nuts and Bolts MOC: SS 55.00 Kg. 300.00
12 Item No.12: Slab Cutting: Slab to be cut by diamond cutter blade 8.00 Job 20000.00
Item No.13: 11 kV Two Pole Structure Assembly:
SITC of 11 kV double pole 9 meter high structure made of 6" X 3" 'I" section girder, 4" X 2" channels, clamps, nuts, bolts, stay
wires including earthing system with following accessories duly connected with ACSR conductors as per approved drawing & in
with requirement of IEC.
(a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP) tubes: 1 Set (01 piece per phase).
13 (b) 11 kV, 400 A G.O.D. switch complete with earth switch, insulators, operating handle with galvanised pipe, square bar: 1 Set.
(c) 11 kV lightning arrestor with clamps: 3 Nos.
(d) 11 kV Disc Insulators (70KN): 3 Nos.
(e) 11 kV Pin Insulators (5KN): 3 Nos.
(f) 20 mm dia. GI Stay Sets Complete: 2 Set.
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.14: Transformer : SITC of outdoor type, three phase, oil immersed, distribution transformer of required KVA & voltage
ratio, copper double wound, vector group - Dyn11, HV delta connected & LV star connected with neutral brought out connected
to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct
as per requirement with standard fittings, conforming to IS: 1180 (Part-1) / 2014 with its latest amendment including first fill of
transformer oil & following accessories.
(a) Oil conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating breather charged with
silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e) Lifting Eyes / Hooks / Lugs (f) Two earthing terminal
(g) Diagram and rating plate (h) Air release plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-
directional plain roller with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit externally
14 operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature indicator (For rating < 500 kVA) (o)
Bucholtz relay with shut off valve (For rating ≥ 500 KVA) (p) 150 mm dial type oil temperature indicator with Alarm / Trip
contact (For rating ≥ 500 kVA) (q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating ≥
kVA) (r) Marshalling box (For rating ≥ 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating ≥ 1600 kVA) (t) Inspection
cover & Jacking lugs (For rating ≥ 1600 kVA)
For transformer having oil storage capacity for 2000 litters and higher, nitrogen injection fire protection system (NIFPS) is to be
provided. With off circuit tap changer +10% to -10% in steps of 2.5%
400 KVA Capacity Transformer - Eff. Level-2
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.15: Transformer Foundation : Casting of transformer plinth/foundation including oil soak pit (where required) in
reinforced cement in M 20 using granite, quartzite trap metal of size 6 mm for RCC work including providing of 53 grade cement
15 & Fe 415 grade TMT bars, scaffolding, centring, form work, curing etc. complete.
Transformer Rating (kVA): 400 kVA
Plinth Dimensions (L x W x H): 1500x1500x 1500 2.00 Set. 35000.00
Item No.16: Construction of wire fencing for 11 KV switch yard : Providing and fixing 1.20 Metre high fencing with 2.0 Metre
long M.S. Angle posts 40mm x 40 mm x6 mm and oil painting 3 coats fixed at 2.5 Mt,C/c. with five Horizontal lines and two
diagonals of galvanised steel barbed wire weighting 9.38 Kg. per 100 Metre, strained and fixed to posts with G.I,staples
including fixing the posts in ground with 0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10 etc complete. 24.00 Rmt. 389.26
17 Item No.17: Providing and Laying best quality gravel bed inside the wire fencing compound as per requirement. 4.90 Cum. 2029.00
Item No.18: Providing, Fabricating, Fixing / Installing Mild Steel Wicket Gates of 2 m x 2 m size as per design with operating
18 handle etc. complete
size 2m x 2m: 1 No. 1.00 LS 28661.00
Item No.19: HT INDOOR SWITCH GEAR PANEL: Supply, installation, testing & commissioning both side extensible, indoor type
HV switchgear panel confirming to IS-3427, IS-2516(Part-I & II.sec.1) & IEC-62271-100/200 for use o 3 phase, 50 hz, unearthed AC
supply system and having breaking/ rupturing capacity of 500 MVA (26.3 kA for 3sec) complete with spring charged mechanism,
ON-OFF mechanical push button, operation counters, Breaker TNC switch, Breaker L/R switch, necessary auxiliary switches,
closing coil, shunt trip, protection relays & indicators etc. complete.
The panel shall comprise of air insulated busbars provided with heat shrinkable PVC sleeves. The VBC trolley shall comprise of
three vacuumed interrupters with epoxy support insulator and self aligning finger type isolating contacts and necessary
mechanical interlocks, safety and shutters, isolating plugs. Enclosure shall be openable from front as well as rear end.
The breaker shall be manual cum motorised mechanism with following accessories.
a) 96x96 mm square flush mounting type ammeter & volt meter with selector switches., b) Multi function meter., c)Double
core, cast resin type current transformer having ratio as per requirement. one core for metering & one core for protection
19 having required class of accuracy., d) Instantaneous under voltage relay & Temperature rise tripping Relay., e) Triple pole
IDMTL two over current and one earth fault relay with current and one earth fault relay with current setting range 50-200% and
10-40%, f) Electrical closing. coil & shunt trip coil & shunt trip coil operating on 110V DC., g) Auxiliary relay for anti pumping
device., h)Three limb, draw out type, feeder connected. cast resin insulted, three phase potential transformer having ratio &
burden as per requirement & class 0.5 accuracy., i) Annunciator windows, command hooter/ Alarm bell operating on 230AC/110
V DC., j)Cable boxes suitable to terminal 3 core XLPE cable of required size(As per design).
k)230 V AC to 110 V DC power pack for closing & tripping circuit common., l) Breaker ON-OFF, Auto trip and spring charged
indicators. m) Phase indicating & panel illumination lamps with plug socket. n) Space Heater with thermostat.
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.20: 415V LVDB (Low Voltage Distribution Board):
S.I.T.C of LVDB (Indoor) totally enclosed, dust & vermin proof, Indoor type, fabricated from CRCA sheet steel with min thickness
of 3 mm for base frame/ channel/ gland plate , 2 33 for load bearing members/ load and 1.6 mm for internal partition, Min
degree of protection IP-52 as per IS 2147, suitable for operation on 3 phase, 4 wire, 415 volt , 50 Hz, neutral effectively
grounded with instrumentation compartments accommodating meters, auxiliary/ protectives relays, LED type indicating lamps &
control MCBs as per IS: 13947. Current & Voltage transformers as per IS per IS: 2705, air insulated electrolytic grade Aluminium/
Copper busbar for three phase & neutral system. GI earth Bus for entire length, power/ control wiring using 1100 V grade, FRLS
insulated copper conductor wires confirming IS 694 & 8130, equipment, fitting & horizontally running Busbar, compartment
height of Min 300 mm, Incoming & outgoing cable connection for 1100 V grade, Al/ Cu conductor XLPE/ PVC insulated & PVC
sheathed armoured cable. LVDB shall have required incoming / Bus coupler/ outgoing modulus of following types & ratings.
(a) PANEL ENCLOSURE:
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from engineer in charge made from 14 SWG thick CRC M.S. Sheet for
outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accessories , supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper
wire / copper-aluminium strips, rubber grommets, rib, Bakelite control fuses/MCB for measuring instruments, earth bus & earth
bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber
gasket, heavy duty end terminal connection, danger notice board, necessary ventilation, earthing strip complete. The Panel
shall be painted with epoxy powder coating. (The rates excludes the cost of switchgears, bus bars, inter connecting mains &
Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size. The standard companies switch gear shall be used and only
manufacturers as per IEC 61439 for beneficial use.- Single door and 750 mm depth
2000 A, 3 & 4 Pole, ACB (Draw-out Type) with Thermal Magnetic / Microprocessor release (O / C, S / C & E / F) having breaking
capacity Icu of 50 kA at 415V with 6NO+6NC potential fee auxiliary contacts, secondary isolating contacts with all necessary
20a Electro-Mechanical protections & interlocks etc. ACB Module shall have enclosure dimension: 2000 (H) x 900 (W) x 1100 (D) &
following technical features: Enclosure dimension: 2000(H) x 900(W) x 1100 (D)
- Supplying & erecting triple pole & neutral 440 V/ 500 V panel mounting Aluminium Bus bar with 4 equal numbers of Bus having
current density not more than 0.8A/sq.mm (rated current/cross section area) dult raped with colour insulating tape for phase
20b sequence of following current caring capacity, erected with necessary Bus-Bar, Supports/ Insulators, Main cable sockets to each
Bus-Bars, erected in Existing Cubical Panel with necessary connections.
Horizontal Bus Bar : 630 Amp. 8.00 Rmt. 3032.49
20c Vertical Bus Bar : 200 Amp. 8.00 Rmt. 1027.77
1. 800 A, 4 Pole, ACB (Draw-out Type) with Microprocessor release (O / C, S / C & E / F) having breaking capacity Icu of 50 kA at
20d 415V with 6NO+6NC potential free auxiliary contacts, secondary isolating contacts with all necessary Electro Mechanical
protections & interlocks etc. 4 pole, EDO with Microprocessor Release- For Pump Motor, APFCR Panels
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
2. above 80A, up to & including 250A, 4 Pole , Air Break Fixed MCCB conforms to IS/ IEC 60947-2 with trip free mechanism,
current limiting type with thermal Magnetic release ( (O/C, S/C & E/F) with adjustable setting & having minimum 2 NO + 2 NC
20e potential free auxiliary contacts with all necessary Electro-Mechanical Protections & interlocks etc. 4 Pole, MCCB with Breaking
Capacity of Icu=50 KA at 415V (Ics =100% of Icu), TM release - For LDB, PDB, Crane etc.
Item No.21: SITC of LV MCC Panel totally enclosed, dust & bermin proof, indoor type, minimum degree of protection - IP 52 as
per IS: 2147, operation on 3-Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with instrumentation compartments
accommodating LED type indicating lamps, control contactors as per IS: 13947, CT of accuracy class- I as per IS: 2705, relays,
meters & control MCBs, air insulated electrolytic grade Aluminium bus bar for three phase & neutral system with incoming
breaker- microprocessor based Air Circuit Breakers (electrically operated draw out type)/ air break fixed type MCCB with trip
free mechanism, current limiting type as per IS: 8828, Motor Contractor (as per type -2 coordination), Overload Relay with built-
in single phasing prevention feature & auxiliary feeders as per SLD drawings, momentary contact type push buttons, equipment
fittings, bus bars, cable boxes, cable gland, incoming & outgoing cable connection for 1100V grade, Aluminium/ Copper
conductor XLPE / PVC insulated & PVC sheathed armoured cable, 10% spare terminals, power wiring using 1100V grade, FRLS
21 insulated copper conductor wires conforming to IS: 694 & 8130, cable compartments / alleys of minimum 300 mm size, GI / Al
earth bus bar for entire length. MCC shall be fabricated from cold rolled, cooled annealed (CRCA) sheet steel & minimum
thickness of various members shall be as follows: Base Frame / Channel / Gland Plate: 3 mm, Load Bearing Members / Doors:
mm and Internal Partitions: 1.6 mm.
Microprocessor Based LV Soft Starter:
Microprocessor Based Soft Starter with built-in / External by pass contactor, Semiconductor Fuses, Harmonic Filters, cast resin
type CT, Digital MFM, Analog Ammeter & minimum 10 Channel Temperature Scanner with RS 485 communication port. - 75 KW
each outer feeder for (2W + 2SB feeder)
Auto Transformer Starter with MCCB, Contactor, O/L relay, cast resin type CT, Digital MFM, Analogue Ammeter, SPP, Timer
21a etc. - 55 KW each outer feeder for (2W + 2SB feeder)
21b Extra charges for ammeter, voltmeter, wiring etc. 1.00 LS 98066.83
Item No.22: SITC of Local Control Station with pendant type Open_Stop_Close pushbutton set and with Open, Close, Trip &
Local / Remote Indicating Lamps complete with Enclosure, necessary mounting/ fixing arrangement on wall / pipe support etc.
22 to be installed near motors for remote operation, etc. as per IS and specifications (including structural steel) - (For 4 nos. 75 kW
Pump & 4 nos. 55 KW Pump) 8.00 No. 6924.00
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.23: LV APFC PANEL: Supply, installation, testing & commissioning LV APFC panel consisting of required capacitor banks
for continuous duty to improve P.F. 0.85 to 0.99 in required steps enclosed in dust & vermin proof compartment, indoor type,
fabricated from CRCA sheet steel with minimum thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load
bearing members / doors & 1.6 mm for internal partitions, minimum degree of protection - IP 42, busbar chamber, required size
of Al bus bar / terminals, minimum 10 stage APFC relay, metering, indicating lamps, push buttons complete as per IS: 16636-
2017 with latest amendment & detailed technical specification and data sheet as under.
Above 50 & up to 100 KVAR capacity: APFC panel consisting following items.
a) 250 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-250 A range analogue ammeter of
x 96 mm size with selector switch c) 3nos. 250 / 5A, 10 VA CL-1.0 cast resin type current transformer d) Suitable rating of MCCB
/MCB & Contactors for each capacitor bank e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB /
non toxic oil, internally delta connected with built in internal fuses complete with discharge resistances & terminal cover) of
approved make in required steps with well suited detuned reactor is placed in series with each capacitor step. ( e.g. 100 KVAR
capacity will be provided in steps of 2 no's x 5 KVAR, 2 no's x 10KVAR, 2 no's x 15 KVAR & 2 no's x 20 KVAR) f) Encloser
dimensions: 2100 (H) x 1150 (W) x 600 (D)
Item No.24: 11kV(Earthed /Unearthed) Grade Cable- Aluminium Conductor: Supply, laying, testing & commissioning 11 /
kV (UE) grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC
type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays /
24 conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-2) & IEC: 60502(Part-2), of
following sizes:
3 Core 300 sq. mm - For 11 KV DP structure to Transformer 125.00 m 1445.00
Item No.25: Cable Terminations / Jointing Kits for 11 kV (UE) grade XLPE Cable: Providing & fitting heat shrink cable
termination / jointing kits for 11 kV (UE) grade XLPE insulated cable including necessary
earth connectivity connection, material & consumables making the termination/ joint complete ensuring the joint resistance is
the permissible limit as per IS, of following types & sizes:
Outdoor termination kit for 11 kV (E) XLPE screened 3 core cable 2.00 Each 11487.00
25a Indoor termination kit for 11 kV (E) XLPE screened 3 core cable 2.00 Each 7384.00
Item No.26: 1.1k Grade cable-Aluminium/Copper Conductor:
Supply, laying , testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat
strip/ round wire armoured, extruded PVC type ST2 sheathed, heavy duty (to be lad on wall surface with necessary clamps/in
existing cable trench / cable trays/ conduit/ pipe sleeve at road crossing or floor as per site requirement) conforming to IS:
7098(part-1) & IEC: 60502(part-1):
2 Run 3.5 Core 500 sq. mm - For Transformer 100.00 m 1634.00
26a 2 Run 3.5 Core 150 sq. mm - For APFCR Panel 100.00 m 503.00
26b 1 Run 3 Core 120 sq. mm - Motor Side -1. Ex 50 LL CWS at Salvav to Ex 75 LL CWS at Chharwada 80.00 m 355.00
26c 1 Run 3 Core 70 sq. mm - Motor Side -2. Ex 50 LL CWS at Salvav WTP to JN A (For Zone 1 & 2 Proposed ESR, 20 & 10 LL) 80.00 m 244.00
26d 1 Run 4 Core 6 sq. mm - For Crane & Misc. 50.00 m 78.00
26e 1 Run 4 Core 4 sq. mm - For LDB 25.00 m 70.00
26f 1 Run 4 Core 4 sq. mm - For PDB 25.00 m 70.00
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.27: Cable Glands: Providing & fitting heavy duty brass cable glands (nickel-plated) with washers & rubber ring
conforming to IS, suitable for 3, 3½ & 4 core cables of following type & sizes:
Double Compression Brass Cable Glands:
27d 3 Core 70 sq. mm 2.00 No. 270.00
27e 4 Core 6 sq. mm 2.00 No. 107.00
27f 4 Core 4 sq. mm 4.00 No. 107.00
Item No.28: Cable Terminals (Lugs): Providing and fitting crimping type cable termination (Lugs) conforming to IS of following
types and sizes:
Aluminium Tubular Terminals (Long Barrel)
Item No.29: Earthing: Supplying & erecting Funnel type earthing having earth plate of following size burred in specifically
prepared earth pit 3 m below ground with 40 kg charcoal & slot with alternate layers of charcoal & slot , 20 mm dia GI pipe with
funnel with a wire mesh for watering & brick masonry block CI cover complete as per para 7.3 of IS 3043 with necessary length
29 of double GI/copper earth wire No.6 SWG bolted with lug to the plate & covered in 12 mm dia GI pipe 2.5 mt. long complete
connected to the nearest switch gear with ends socket as per direction & duly tested by earth tester conforming to IS (As per
Drawing) with following specifications.
With 45 X 45 X 0.35 cms CI earth plate
29a With 60 X 60 X 0.315 cms Copper earth plate - For Transformer Body, Neutral & 11 KV DP Structure 6.00 Each 7803.78
Item No.30: Cable Tray & Accessories: Supply & laying GI ladder type cable trays with side channels of size - 75 x 15 x 15 mm /
100 x 15 x 15 mm & rungs of size - 35 x15 x 15 mm spaced at 250 mm apart, fabricated from 2 mm thick sheet steel in standard
length of 2.5 meter, duly hot dipped galvanized after fabrication as per IS 2629-1989/ IS 4759-1984 including accessories such as
coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing
support as per specification and instruction of Engineer-in-charge.
Item No.31: Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
-for earthing of Transformer, LT Pannel board, Motors, etc. using necessary clamps. 900.00 Kg. 77.17
Item No.32: Supplying rubber matting of following thicknesses per IS:15652/IEC
4 mm Thickness. 24.00 Sq.mm. 1017.00
(R&B Electrical SoR 2025-26,Ch.10, I.No-10.2.3)
Item No.33: Providing and erecting metallic vitrified danger notice board as per language suggested by engineer in charge for
MEDIUM VOLTAGE installation to be erected as per IS-2551. 4.00 No. 69.13
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.34: Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for
treatment of person suffering from Electric shock with minimum 50" diagonally size. 4.00 No. 129.06
Item No.35: Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge
bandage, medicated ready to use bandage (Band-aid adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or
similar) etc. (All above contents shall be of standard makes)
Item No.36: Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at
36 bottom duly painted white in side and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or
hung on wall hook. 4.00 No. 212.00
Item No.37: Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length,
37 900 mm height frame made out of 30 mm X 30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly
painted with one coat of red lead an two coats of approved enamelled silver paint. 1.00 No. 933.43
38 Item No.38: Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. 1.00 No. 212.00
Item No.39: CCTV Camera System
Supply of high quality images in low light condition IP based PTZ Dome Camera with smart auto tracking ,Optical Zoom, digital
zoom, HD CMOS, 120db WDR, camera shall be with 200 Mt IR, seven alarm inputs, 2 outputs, Smart tracking modes: Manual/
Panorama/ Intrusion trigger/ Line crossing trigger/ Region entrance trigger/ Region rectified with Installation of necessary
accessories with High End Professional Display for 24x7 Operation - 400/500 nits Brightness
Item No.40: Ultrasonic type level transmitter with remote display:
Design, Supply, Installation, Testing and Commissioning of Non Contact Ultrasonic Type Level Transmitter with Remote Display.
The sensor should be non contact type, field mounting type, housing shall have minimum IP65 protection, PP/ PVC Sensor MOC,
with sensor to transmitter cable.
40 Remote Indicator cum Transmitter:
Microprocessor based indicator with LED / LCD digital display, panel/ wall mounting type, power supply shall be 110-240 Vac or
Accessories: Mounting bracket, nut, bolts etc as per system requirement and Hook up diagram of the Instruments.
Size: 0 to 10 Meter
Item No.41: Supply, installation, testing and commissioning of Pressure Transmitter with Micro-processor based integral LED/
LCD display along with, manifold valve, required fittings, tubing (all valves, fittings, tubing's, etc. shall be in SS 316 only) all
41 accessories, hardware, etc. complete in all respects as per specifications and having following measurement ranges:
Range : 0 to 10 or o to 20 Kg/cm2 (On Main Header)
Item No.42: Float/ Displacer Type Level Switch
Design, Supply, Installation, Testing and Commissioning of Top mounted Displacer Type level switches with 2 no's SPDT contacts
of Micro switch rated 5 A, potential free power supply, Material of wetted parts shall be SS 316 and the material of accessories
shall be SS. IP 65 or equivalent degree of protection for enclosure, suitable for sump, ESR, tank, vessels and underground
42 reservoirs. The top mounted level switches shall be supplied with still tubes to suit the requirement. . Accessories like name
plate, mating flange, gaskets, fasteners, bolts & nuts, etc. shall be supplied with the Level Switch.
Range: 0 to 5 Meter
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.43: PLC/RTU Panel for Field Location
Supply, Installation, Testing & Commissioning of PLC/RTU panel including PLC, Gateway with SIM Card for remote operation and
monitoring of Flow, Pressure and Valve parameters.
Minimum 8DI, 4 DO, 1RS485 communication shall be considered.
43 Real time communication with central SCADA shall be considered for operation and monitoring from central SCADA.
Panel Shall be IP65 with Local indication and push button for Local operations of valve. UPS with battery backup of 30 minutes
shall be provided in the panel.
20 meter Power Cable from 415 supply nearby shall be considered up to PLC/RTU panel.
Item No.44: INSTRUMENT CABLE & ACCESSORIES
Supply, Laying, Installation, Connection, Termination, Testing & Commissioning of Instrument Cables, along with cable glands,
lugs, cable trays, required junction boxes, fittings and accessors as per specs.
The unit rate shall include
a. Supply, loading & unloading of the cable at site from store.
44 B. Shifting of cable from site store to place of installation.
c. Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely.
d. Excavation, back filling and levelling of ground along with laying of fine sand, protection bricks and other necessary civil
material for laying cables outside the building.
e. Testing and submission of sketches & reports of all the cables laid.
POWER CABLE- 3C x 4 sq.mm.
44a CONTROL CABLE- 8C x 1.5sq.mm. 60.00 Mtr. 145.00
44b SIGNAL CABLE- 1P x 1.5sq.mm. 60.00 Mtr. 127.00
Item No.45: CABLE END TERMINATION AND CONNECTION
'Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetallic
lugs / sockets with necessary tools and equipment's as specified in specifications and IS complete in all respects. The glands and
45 lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour
of the cable with common earth bar or flexible copper mesh as applicable.
Power Cable -3C x 4 sq.mm. 35.00 Nos. 145.00
45a Control Cable -8C x 1.5 sq.mm. 35.00 Nos. 135.00
45b Signal Cable - 1P x 1.5 sq.mm. 35.00 Nos. 115.00
Item No.46: Instrument Cable Tray: Providing and fixing approved make Perforated C type cable tray. Made from sheet steel.
The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and
46 washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge.
50 X 50 X 1.6 mm Thick
Item No.47: Providing and casting in situ C.C. in grade M-20 (proportions as per mix design or as per table9 of IS456 2000 in
masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding
47 centring, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centring and shuttering/DE shuttering etc. complete for structure other than water
retaining (Below G.L) 7795.85
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.48: Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS
48 including cost of steel and binding wire for reservoirs/structures only including lift up to 6 meter height or depth below G.L. for
all diameters 900.00 Kg. 84.19
Total for Schedule-B3(Rs.) =
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF
ELEVATED SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING,
SUPPLING, ERECTING & TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD
REINSTATEMENT & SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY
SCHEME (PHASE-2) FOR VAPI MUNICIPAL CORPORATION, DISTRICT: VALSAD.”
SCHEDULE - B4 : HEADWORK DEVLOPMENT WORK
(COMPOUND WALL, RCC ROAD/APPROACH ROAD, SECURITY ROOM, MS GATE, ELECTRICAL WORK)
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.1: Construction of compound wall of brick masonry including all civil works with labour and material cost as per
rate analysis and as shown in drawing. Work including excavation for column footing in all type of strata. Providing and laying
of 100 mm thick PCC in M10 grade of concrete and 750x750x200 mm thick RCC column footing,230x230x2.85 mt. height RCC
column in M20 grade of concrete. 100 mm thick PCC providing and laying for ground level beam in M10 grade, 230x350 mm
RCC Ground level beam and 100 mm thick RCC coping at top on the compound wall in M20 grade of concrete. all RCC work
including formwork, curing, steel cutting, binding etc completed. 230 mm thick x 1.5 mt. height from top of ground level
beam in 1:6 cement mortar Brick wall constructing by using common burnt building bricks having crushing strength not less
1 that 35 Kg/Cm2. 20 mm thick sand faced cement plaster on walls up to height 1.5 metres above ground level consisting of
mm thick backing coat of C.M. 1:3 (1 cement : 3 sand ) and 8 mm thick finishing coat of C.M. 1:1 (1Cement : 1 Sand ) etc.
complete. water proofing cement paint of on wall surfaces (Three coats) to give an approved brand etc. completed.
Providing and fixing 1.20 Metre high fencing with 2.0 Metre long M.S. Angle posts 40mm x 40 mm x6 mm and oil painting
coats fixed at 2.5 Mt, C/c. with five Horizontal lines and two diagonals of galvanised steel barbed wire weighting 9.38 Kg. per
100 Meter etc. completed as per minimum BoQ and tender drawings.
Item No.2: Construction of RCC roads / approach Road Reinstatement of roads with RCC where pipe crossing the asphalt road
/ RCC road / industrial area / residential area. the Work including excavation, dressing, formwork, curing etc. completed and
2 making a base for road, 100 mm thick PCC in M10 grade of concrete, and Providing and laying 150 mm thick RCC M15 grade
concrete, Providing TMT bars FE-415 reinforcement for RCC work including bending, binding and placing in position complete.
Item No.4: Providing and Fixing of 4 mt. x 2 mt. height MS Gate with 1 mt. width wicket gate made from 50 mm X 4 mm thk
MS Pipe,50 mm x 5 mm MS flats, Channels and Flats including all Material & labour for fabrication, welding, cutting, hoisting,
4 fixing of position and Painting two coats (excluding priming coat ) on new steel and other metal surface with synthetic
enamel paint and fixing at site of work including carting, loading, unloading etc. complete. - 2 no's
Item No.5: Electrical Item like wiring, points, lighting arrangements, fans, street lights etc. for pump house/security
5 room/material safety room/staff quarter room/ street light at Rcc road etc.
Total for Schedule-B4(Rs.) =
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF
ELEVATED SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING, SUPPLING,
ERECTING & TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD REINSTATEMENT &
SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR
VAPI MUNICIPAL CORPORATION, DISTRICT: VALSAD.”
SCHEDULE - B5: CONSTRUCTION OF HOUSEHOLD CONNECTIVITY(2367 Nos.)
SR. RATE TOTAL AMOUNT
SR. RATE TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT
Item No.1: Providing and supplying in true line and level 15mm dia. U.P.V.C. Pipe (SCH-40) for cold water including fittings
1 make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge.
Item No.2: Providing and supplying in standard length ISI mark rigid unplasticized PVC pipe suitable for portable water with
ring fit joint incl cost of ring, as per IS specification no 4985/1988 incl all local and central taxes, transportation, freight
2 charges, octroi, inspection charges, loading, unloading, conveyance to the departmental store and incl cost of jointing material
etc comp - 6kg/cm2
Item No.3: PVC fittings : Purchasing and supplying at store or site of work G.I./P.V.C. Specials as per requirement incl. Railway
freight, loading, unloading, stacking, and carting from store to site. Sales tax, insurance, octroi, GST & all taxes etc. complete.
3 UPVC Couplers 15 mm dia.
3a UPVC Couplers 90 mm dia. 135.00 No. 78.00
3b Bib Tap 15 mm dia. 2232.00 No. 25.00
3c PVC Flange with pail pieces 90 mm dia 135.00 No. 236.00
3d Service Saddle 15 mm dia. (110/90/75/63/50 mm × 15 mm dia.) 2232.00 No. 50.00
3e Nut bolt 540.00 No. 40.00
3f UPVC Tee (Moulded) 2232.00 No. 20.00
3g UPVC Elbow 15 mm dia. 8928.00 No. 6.00
3h UPVC Elbow 90 mm dia. 135.00 No. 216.00
3i UPVC Clamp 2232.00 No. 10.00
Item No.4: Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and strutting if
required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up
4 to all required lead cleaning the site etc. complete for all lifts and strata as specified.
Upton 0 to 1.5 Mt. Depth
In all sorts of soil and soft murrum 803.52 Cu.m 102.35
4a In hard murrum, boulders incl. macadam road. 3215.70 Cu.m 155.25
Item No.5: Lowering, laying, fixing and jointing PVC/UPVC/CPVC pipes and specials of following class and diameter including
cost of conveyance from stores to site of works including cost of labour, material, cement solvent, giving satisfactory hydraulic
testing as per ISI code. Rate is taken for 63 mm and prorated for 15 mm
5a 90 mm Dia 675.00 Rmt 19.55
Item No.6: Refilling the pipeline trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a
radius of 3 km. 3937.59 Cu.m 25.30
7 Item No.7: Cutting of Road : C.C 1:2:4 or RCC 211.41 Cu.m 427.80
7a IPS Cutting 100.44 Cu.m 427.80
Item No.8: Providing and casting in situ mass cement concrete in 1:4:8 proportion using granite quartzite trap metal of size
8 mm to 40 mm including consolidation curing etc. complete. 311.85 Cu.m 3901.95
Item No.9: Making hole for Fitting saddle in to Existing pipe (110/90/63/50 mm) or New laying pipe. Lowering, laying and
9 jointing 110/90/63/50 mm × 15 mm dia. Service Saddle including cost of labour, material, with cement solvent, giving
satisfactory hydraulic testing as per ISI code. 2232.00 No. 100.00
Total for Schedule-B5(Rs.)
SUMMARY (SCHEDULE-B)
SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF
ELEVATED SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING, SUPPLING,
ERECTING & TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD REINSTATEMENT &
SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR
VAPI MUNICIPAL CORPORATION, DISTRICT: VALSAD.”
SCHEDULE - B6 : SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION FOR SALVAV WATER SUPPLY
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.1: Supply, Installation, Testing and Commissioning of ISI mark CI D/F Sluice Valve as per IS 14846 PN 1.0 with
Electrically / Manually operated including non-modulating type (ON/OFF operation only), Motorised valve shall be suitable for
underwater operation in case of flooding in the chamber(Min IP68 rated).Type of valve, pressure of water, location and
interface to be provided for correct valve operation. valves can be modulating also, you can use for flow control. Non -
modulating are ON / OFF type only (Open / Close type) of following sizes with Integral Starter, SS 304 seat rings, SS rising
1 spindle with all hot dipped galvanised hardware's, bolts, nuts & washers, gaskets and handwheel including all taxes, insurance,
transportation, freight charges, Inspection Charges, loading unloading, conveyance to pump house, stacking, security etc.
complete as per IS and Specification.
Lowering, laying and jointing C.I./D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour,
jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.
200 mm NB (Electrically Operated)
1a 250 mm NB (Electrically Operated) 3.00 No. 472212.90
1b 300 mm NB (Electrically Operated) 4.00 No. 478348.15
1c 350 mm NB (Electrically Operated) 2.00 No. 491601.30
1d 450 mm NB (Electrically Operated) 5.00 No. 522710.00
1e 500 mm NB (Electrically Operated) 1.00 No. 570394.75
1f 600 mm NB (Electrically Operated) 1.00 No. 614500.05
Item No.2: Electromagnetic Flow Meter- Regular Power Operated- PN 10 :
Supply, installation, testing and commissioning of remote type Full Bore Electromagnetic flow meter comprising of IP-68 Sensor
SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding
Electrode, Neoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive
Paint Coil Housing with Junction Box, CS flanges.
Flow Transmitter: Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate, forward, reverse, sum
totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity, 4 to 20 mA with HART/Modbus output, one scalable pulse, one
2a status output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window
enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to transmitter communication etc. along with wall
mounted/ stand mounted cabinet.
Panel mounted flow indicator cum Totalizer along with all mounting accessories, hardware, etc. complete in all respect and as
per specs and shall have following size measurement range. The scope also includes necessary connection with header pipe.
200 mm Nominal Bore
2b 250 mm Nominal Bore 3.00 No. 117201.00
2c 300 mm Nominal Bore 4.00 No. 134422.00
2d 350 mm Nominal Bore 2.00 No. 185900.00
2e 450 mm Nominal Bore 5.00 No. 226181.00
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
2f 500 mm Nominal Bore 1.00 No. 263124.00
2g 600 mm Nominal Bore 1.00 No. 303222.00
Item No.3: Design , Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Guage, +1& accuracy, Direct bottom
1/2" NPT (M) process connection, IP 67, Glycerine filled, SS304 case with Bayonet Type Bezel, SS316 L Bourdon Tube, SS316
movement material, Aluminium dial with black graduation on white background, Micro Zero adjustable pointer, neoprene
3 gasket, Blow out disc, shatter proof glass, SS tag plate as per IS 3624. - 0 to 10 Kg/cm2.
100 mm Dial Size
Item No.4: Supply, installation, testing and commissioning of Pressure Transmitter with Micro-processor based integral LED/
LCD display along with, manifold valve, required fittings, tubing (all valves, fittings, tubing's, etc. shall be in SS 316 only) all
4 accessories, hardware, etc. complete in all respects as per specifications and having following measurement ranges:
Range : 0 to 10 or o to 20 Kg/cm2
Item No.5: Construction of RCC Valve Chamber including dewatering required. Damage to existing pipe shall be made good as
per original. Slope of chamber shall be such that excess water shall be drained and taken to a local drain. Space for
5 maintenance shall be provided. (Chamber can be bigger. ensure rung ladders or similar is provided for person to access the
Item No.6: Providing and casting in situ C.C. in grade M-15 (approx. corresp. to prop. 1:2:4) (proportions as per mix design or as
per Table 9 of IS456 2000 in masses by weigh batching) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work,
including scaffolding centring, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding
6 cost of reinforcement and neat finishing) with centring and shuttering/DE shuttering etc. comp. for structure for other than
water retaining. Footing for column or foundation (with form work)
Panel Foundation for Field PLC/RTU Panel
Size : 1.8 m L X 0.8 m W X 0.5 m H (79 Locations)
Item No.7: PLC SCADA SYSTEM
PLC SCADA SYSTEM
Supply, Installation, Testing & Commissioning of PLC Based Instrument control Panel with Local SCADA system comprising of
min. 21” PC, CPU:
i7, 16 GB RAM, 1 TB SSD and monitor to display all the valves in the network and their positions with colour coding. Console with
A4 size laser jet printer for report / alarm printing, SCADA run time display software, 4G / 5G GSM modem, provision of future
connectivity at VpMC office SCADA, creation of software to poll between the 17 nos. Salvav locations to SCADA Server, get
exact position details, send command for changing position, received command for position achieved and shutoff etc.
Instrument Control Panel (PLC Enclosure / Panel ) with necessary PLC based logic and wiring , Min 1 nos. flow
7 indicator/totalizer, Min. 1 no. process Indicator, Min 2 no. analogy signal multiplier, Min. 1 kVA UPS (with 30 min backup along
with filter for harmonic, suitable rating SMF batteries along with battery charger, cabling between UPS and battery and all
other accessories as per standard), etc. complete in all respects and as per specs IO list shall include - power supply availability,
motor healthy, starter operating, position of the valve etc. A network switch is required at each of 17 nos. Salvav location. This
will ensure that the signal communication from the remote SCADA System can be done using wireless communication between
central SCADA/PLC to field RTU having gateway with SIM card. Enclosure shall be IP 54 or better and shall be placed at central
location proposed by Department. The PC shall also have back up software for PLC. All licenced software to be provided. All
work shall be carried out complete in all respects and as per tender specifications.
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
PLC/RTU Panel for Field Location
Supply, Installation, Testing & Commissioning of PLC/RTU panel including PLC, Gateway with SIM Card for remote operation and
monitoring of Flow, Pressure and Valve parameters.
Minimum 8DI, 4 DO, 2AI, 1RS485 communication shall be considered.
7a Real time communication with central SCADA shall be considered for operation and monitoring from central SCADA.
Panel Shall be IP65 with Local indication and push button for Local operations of valve. UPS with battery backup of 30 minutes
shall be provided in the panel.
20 meter Power Cable from 415 supply nearby shall be considered up to PLC/RTU panel.
Item No.8: POWER AND INSTRUMENT CABLE & ACCESSORIES
Supply, Laying, Installation, Connection, Termination, Testing & Commissioning of Instrument Cables, along with cable glands,
lugs, cable trays, required junction boxes, fittings and accessors as per specs.
The unit rate shall include
a. Supply, loading & unloading of the cable at site from store.
8 b. Shifting of cable from site store to place of installation.
c. Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely.
d. Excavation, back filling and levelling of ground along with laying of fine sand, protection bricks and other necessary civil
material for laying cables outside the building.
e. Testing and submission of sketches & reports of all the cables laid.
Power Cable -3C x 4 sq.mm. 850.00 m 184.00
8a Control Cable -8C x 1.5 sq.mm. 850.00 m 145.00
8b Signal Cable - 1P x 1.5 sq.mm. 1020.00 m 127.00
Item No.9: CABLE END TERMINATION AND CONNECTION
'Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetallic
lugs / sockets with necessary tools and equipment's as specified in specifications and IS complete in all respects. The glands and
9 lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour
of the cable with common earth bar or flexible copper mesh as applicable.
Power Cable -3C x 4 sq.mm. 170.00 No. 145.00
9a Control Cable -8C x 1.5 sq.mm. 170.00 No. 135.00
9b Signal Cable - 1P x 1.5 sq.mm. 255.00 No. 115.00
Item No.10: Instrument Cable Tray
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or
double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with
10 max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary
support (included) as per Specification and as per instruction of engineer in charge.
50 X 50 X 1.6 mm Thick
Item No.11: Earthing: Supplying & erecting Funnel type earthing having earth plate of following size burred in specifically
prepared earth pit 3 m below ground with 40 kg charcoal & slot with alternate layers of charcoal & slot , 20 mm dia GI pipe with
funnel with a wire mesh for watering & brick masonry block CI cover complete as per para 7.3 of IS 3043 with necessary length
11 of double GI/copper earth wire No.6 SWG bolted with lug to the plate & covered in 12 mm dia GI pipe 2.5 mt. long complete
connected to the nearest switch gear with ends socket as per direction & duly tested by earth tester conforming to IS (As per
Drawing) with following specifications.
With 30 x 30 x 0.35 cms: C.I. earth plate.
SR. TOTAL AMOUNT
SR. TOTAL AMOUNT
ITEM DESCRIPTION QTY. UNIT RATE (RS.)
Item No.12: Supply, erection, testing & commissioning of Cast Alu. Junction Boxes along with all required hardware in GI,
12 supporting structure, etc. complete in all respects as per following:
10 Terminal Junction box (suitable for cable) 36.00 No. 3500.00
12a 25 Terminal Junction box (suitable for cable) 36.00 No. 5000.00
Item No.13: Cable Trench, Laying & Installation of Cable; Making cable trench in soft soil of suitable width of 90cms deep for
laying cable all over the run and back filling the same and making the surface as normal ground as per IS & Specification.
13 (For laying cable in ground)
Item No.14: Cable Covering in Trench: Cable Covering with second class bricks or cement tiles laid cover the cable crosswise &
also on both side with covering of 7.5cms. Layer of sand above & below cable (16 bricks per meter.) as per IS & Specification.
14 (For cable in ground)
Item No.15: Supplying rubber matting of following thicknesses per IS:15652/IEC
4 mm Thickness. 34.00 Sq.m 1017.00
Item No.16: Providing and erecting metallic vitrified danger notice board as per language suggested by engineer in charge for
MEDIUM VOLTAGE installation to be erected as per IS-2551. 17.00 No. 69.13
Item No.17: Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for
treatment of person suffering from Electric shock with minimum 50" diagonally size. 17.00 No. 129.06
Item No.18: Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge
18 bandage, medicated ready to use bandage (Band-aid adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or
similar) etc. (All above contents shall be of standard makes) 5.00 No. 297.00
Item No.19: Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap
19 gram CO2 gas cartridge, powder and brackets confirming to IS 2171 1985 and complete erected with necessary clamps made
from 50 x 6 mm M S Flat with nuts and bolts grouted in wall complete. [A] For 5 Kg Capacity 18.00 No. 1696.26
Total for Schedule-B6(Rs.) =
SUMMARY (SCHEDULE-B)SALVAV WATER SUPPLY PROJECT (PHASE-2)
1) SALVAV WATER SUPPLY SCHEME: WORKING SURVEY, SOIL INVESTIGATION,DESIGN OF WATER SUPPLY SCHEME.WORK INCLUDING DESIGN & CONSTRUCTION OF
ELEVATED SERVICE RESERVOIR, PROVIDING, SUPPLYING, LOWERING, LAYING AND JOINTING DI PIPELINE FOR GRAVITY DISTRIBUTION NETWORK, PROVIDING, SUPPLING,
ERECTING & TESTING OF PUMPING MACHINERIES, HEADWORK DEVELOPMENT AT VARIOUS ZONE, CONSTRUCTION OF HOUSE CONNECTION & RCC ROAD REINSTATEMENT &
SITC WORK OF INSTRUMENTATION WORK & SCADA SYSTEM AT GRAVITY DISTRIBUTION NETWORK LOCATION ETC. FOR SALVAV WATER SUPPLY SCHEME (PHASE-2) FOR
VAPI MUNICIPAL CORPORATION, DISTRICT: VALSAD.”
SCHEDULE-C: OPERATION & MAINTANANCE (FOR 5 YEARS)
Description Qty Unit Rate Amount
ITEM NO.1: Comprehensive Operation and Maintenance of Rising Main and Gravity Main distribution
pipeline network. This system includes Elevated Storage Reservoirs, Headwork Development, House
Connectivity, SITC work of Instrumentation work & Scada System at Gravity Distribution Network to ensure
reliable water distribution and other allied works. This also involves the integration of essential
mechanical, instrumentation, and electrical components, alongside headwork to enhance water
management efficiency including
1) Breakdown Maintenance or Emergency Maintenance,
1 2) Day to day Maintenance 1 Per Year 21,65,710.28
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including Training to O & M staff of Municipality.
The rate shall also include all consumables and deployment of Manpower but excluding electric power (The
electrical bill for power shall be paid by the municipality) . The O & M work shall be carried out as per
detailed specifications in the tender & maintaining the record for the same.
Comprehensive Operation and Maintenance of Rising Main and Gravity Main distribution pipeline network.
This system includes Elevated Storage Reservoirs, Headwork Development, House Connectivity, SITC work
of Instrumentation work & Scada System at Gravity Distribution Network to ensure reliable water
distribution and other allied works. This also involves the integration of essential mechanical,
instrumentation, and electrical components, alongside headwork to enhance water management efficiency
1) Breakdown Maintenance or Emergency Maintenance,
2) Day to day Maintenance
1a 1 Per Year 25,98,852.33
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including Training to O & M staff of Municipality.
The rate shall also include all consumables and deployment of Manpower but excluding electric power (The
electrical bill for power shall be paid by the municipality) . The O & M work shall be carried out as per
detailed specifications in the tender & maintaining the record for the same.
SCHEDULE-C: OPERATION & MAINTANANCE (FOR 5 YEARS)
Description Qty Unit Rate Amount
Comprehensive Operation and Maintenance of Rising Main and Gravity Main distribution pipeline network.
This system includes Elevated Storage Reservoirs, Headwork Development, House Connectivity, SITC work
of Instrumentation work & Scada System at Gravity Distribution Network to ensure reliable water
distribution and other allied works. This also involves the integration of essential mechanical,
instrumentation, and electrical components, alongside headwork to enhance water management efficiency
1) Breakdown Maintenance or Emergency Maintenance,
1b 2) Day to day Maintenance 1 Per Year 28,87,613.70
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including Training to O & M staff of Municipality.
The rate shall also include all consumables and deployment of Manpower but excluding electric power (The
electrical bill for power shall be paid by the municipality) . The O & M work shall be carried out as per
detailed specifications in the tender & maintaining the record for the same.
Comprehensive Operation and Maintenance of Rising Main and Gravity Main distribution pipeline network.
This system includes Elevated Storage Reservoirs, Headwork Development, House Connectivity, SITC work
of Instrumentation work & Scada System at Gravity Distribution Network to ensure reliable water
distribution and other allied works. This also involves the integration of essential mechanical,
instrumentation, and electrical components, alongside headwork to enhance water management efficiency
1) Breakdown Maintenance or Emergency Maintenance,
1c 2) Day to day Maintenance 1 Per Year 31,76,375.07
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including Training to O & M staff of Municipality.
The rate shall also include all consumables and deployment of Manpower but excluding electric power (The
electrical bill for power shall be paid by the municipality) . The O & M work shall be carried out as per
detailed specifications in the tender & maintaining the record for the same.
SCHEDULE-C: OPERATION & MAINTANANCE (FOR 5 YEARS)
Description Qty Unit Rate Amount
Comprehensive Operation and Maintenance of Rising Main and Gravity Main distribution pipeline network.
This system includes Elevated Storage Reservoirs, Headwork Development, House Connectivity, SITC work
of Instrumentation work & Scada System at Gravity Distribution Network to ensure reliable water
distribution and other allied works. This also involves the integration of essential mechanical,
instrumentation, and electrical components, alongside headwork to enhance water management efficiency
1) Breakdown Maintenance or Emergency Maintenance,
1d 2) Day to day Maintenance 1 Per Year 36,09,517.13
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including Training to O & M staff of Municipality.
The rate shall also include all consumables and deployment of Manpower but excluding electric power (The
electrical bill for power shall be paid by the municipality) . The O & M work shall be carried out as per
detailed specifications in the tender & maintaining the record for the same.
Total for Schedule-C (Rs.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
004 Annexure -2 (Schedule B) Salvav WS-Without Refx.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .