Loading…
Loading…
Tender Value
₹7.7 L
EMD Value
₹19,200
Closing Date
28 Sept 2026, 5:00 pmDue tomorrow
Executive Engineer,PMU ,Kattakada.
O/o Executive Engineer,PMU,Kattakada
Reconductoring 11kV OH line Using Covered Conductor at Various Locations under Electrical Section, Kanjiramkulam of Electrical Division, Neyyattinkara under Electrical Circle, Kattakada
2026_KSEB_867246_1
EE/PMU(KTDA)/ET-20/2026-27 dated 01.09.2026
Open Tender
Electrical Works
Percentage
120 days
Kanjiramkulam
6 documents required · 6 mandatory
₹1,888
₹19,200
28 Sept 2026
2 Sept 2026
1 Oct 2026
2 Sept 2026
28 Sept 2026
2 Sept 2026
2 Sept 2026 - 8 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Stringing of one km 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalant (3 conductors) after fitting insulators, binding conductors to pin insulators using suitable tie and anchoring with wedge type anchoring clamps including cutting and removing tree branches wherever necessary excluding cut point works. | 3,500 | m | 43.49 | ₹1,52,215 |
| 2 | Dismantling (without damage) one km 11kV line (three conductors) including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials. | - | km | 13,827.18 | - |
| 3 | Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point. | 27 | No | 158.91 | ₹4,290.57 |
| 4 | Providing bridging at Cut points for 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalent (1 conductors) using IPC and respective conductors | 168 | E | 173.36 | ₹29,124.48 |
| 5 | Fitting one set (3No.) 11kV LA and giving connections excluding earthing. | 7 | No | 481.95 | ₹3,373.65 |
| 6 | Renewal of existing damaged/old 11kV Stay with new stay in place including excavation & backfilling of pit, dismantling, refitting of all items and conveyance of all materials. | 30 | No | 1,843.14 | ₹55,294.2 |
| 7 | Renewal of existing damaged/broken old 11kV Stay to the existing stay rod. | 30 | No | 564.55 | ₹16,936.5 |
| 8 | Renewing one 1.8m Channel cross arm on the 11kV Pole including dismantling and conveyance. | 16 | No | 813.36 | ₹13,013.76 |
| 9 | Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing. | 4 | No | 2,795.55 | ₹11,182.2 |
| 10 | Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials. | 8 | No | 564.55 | ₹4,516.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1468453.xls
BOQ • 0.36 MB
BID20.pdf
Tender Documents • 0.35 MB
Corrigendum2.pdf
PDF • 0.03 MB
Corrigendum1.pdf
PDF • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .