| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹11.8 L+₹1.3 L (12.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
30 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT- 133001
PREVENTIVE MAINT TO BOOSTER HL CWL REGT TANK BABYAL AND BOOSTER NO 15 WITH CONNECTED ITEMS IN SECTOR B UNDER GE UTILITY AMBALA CANTT
2021_MES_444019_1
GE(U)/AMB-13/2021-22
Open Tender
Civil Works
Item Rate
240 days
AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹24,000
Yes
17 Aug 2021
2 Jun 2021
2 Jul 2021
2 Jun 2021
30 Jun 2021
16 Jun 2021
2 Jun 2021 - 15 Jun 2021
60 days
Amount
M&L dismantling centrifugal induction motor from foundation and transport to work shop for rewinding after taking out burnt winding wire from motor of capacity 40/50 HP three phase , rewinding with copper wire of suitable gauge or as per existing gauge complete including all required insulation material and transport back to site after testing and commisioning complete all as specified and directed by Engineer in charge. Note : a) The Motor testing will be done before installation on No load for any unbalance load and should be free from vibration and if found unsatisfactory no payment will be done to contractor for defected motor. b) Necessary thimbles, lugs, insulation tape, nut bolts and all items required for installation of motor at site will be included in the rate quoted by the contractor. No extra payment will be done to contractor. c) After dismantling of induction motor repair of PCC foundation work will be executed with replacement of base frame of angle iron of existing size of angle if found damaged or deformed. PCC and base frame angle iron will be measured and paid separately under respective items.
Description all as per srl item No 1.00 here in before but of capacity 30 HP
Description all as per srl item No 1.00 here in before but of capacity upto 20 HP
M & L PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate for foundation of suitable size or as per site requirement including demolition of old PCC foundation complete all as specified and directed by Engr-in-Charge. Note : The debris after demolition of PCC should be removed complete and spread to area where directed by incharge.
Material and labour nut-bolts any size all as specified and directed by the Engr-in-Charge.
M&L in replacement of old wornout/deformed base frame of centifugal pump set made out of angle iron of size ISA 5050, 50x50x6mm or medium channels of size MC-100 including cutting, drilling hole or welding work required to make desired shape or existing size duly paint with one coat of primer red oxide and two coat of enamel paint all as specified and directed by the Engr-in-Charge. Note: The base frame should be grouted complete in PCC foundation and should be taken necessary bearing strength before the installation of induction motor.
Material & labour in replacement for ball bearing of the induction motor of size/No. 6215 or as per existing/suitable size complete. Note: a) The rate of dismantling and refixing of motor from pump with complete accessories are quoted in the same item. b) The alingnment of shaft should be checked during installation of motor with pump in all respect. The contractor will be bear the cost of repair in case of failure of motor occurs due to misalingment and no extra payment will be paid to contractor.
Description all as per srl item No 7.00 here in before but of size/No. 6310ZZ or as per existing/suitable size complete.
Supply and fix in replacement Cast iron sluice valve 150 mm dia, flanged ends, stem (spindle) of SS (forged) and check nut of gun Metal, PN rating 1.6, working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valve complete all as specified and directed by Engr-in-Charge.
Description all as per srl item No 9.00 here in before but of size 100 mm dia.
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size 80 to 150mm bore size all as specified and directed by the Engr-in-Charge.
Taking out sluice valves refacing, regrinding and refixing including replacement of spindle, check nut complete assembly and make serviceable of size 80 to 150mm bore size all as specified and directed by the Engr-in-Charge.
Supply and fix in replacement NRV with flanged ends with nut-bolts and rubber gasket suitable for pipe of size 150 mm including taking out the unserviceable non return valve from the pipe complete all as specified and directed by Eng-in-Charge.
Description all as per srl item No 13.00 here in before but of size 100 mm dia.
Supply and fix in replacement Foot valve with flanged ends with nut-bolts and rubber gasket suitable for pipe of size 100 mm including taking out the unserviceable foot valve from the pipe complete all as specified and directed by Eng-in-Charge.
M& L in replacement of the unserviceable contactor 3 pole of AC3 rating upto 50 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screws all as specified by Engr-in-charge.
M& L in replacement of the unserviceable contactor 3 pole of AC3 rating upto 32 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screws all as specified by Engr-in-charge.
M& L in replacement of the unserviceable contactor 3 pole of AC3 rating upto 70 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screws all as specified by Engr-in-charge.
M&L in replacement of the unserviceable timer switch suitable for 240/415 Volts 3-30 Sec, 50 Hz complete all as specified by Engr-in-charge.
Material and labour against replacement of worn out / defective thermal overload relay with range 45-75 Amps 415 V, 50 Hz,complete all as specified and directed by Engr-in-Charge.
Material and labour against replacement of worn out / defective thermal overload relay with range 30-50 Amps 415 V, 50 Hz,complete all as specified and directed by Engr-in-Charge.
S&F in replacement of centrifugal pump of horizontal split casing type, of discharge 70-90cum/hr and 30-45m head, 1460 rpm with suction and delivery size of 100/80 mm with new coupling and key suitable with exisitng electric motor shaft including alignment and nut-bolts, washers testing commissioning complete all as specified and directed by the Engr-in-Charge. Note: Old centrifugal pump dismantled at site will be deposited in MES store by contractor.
S&F in replacement of PVC float valve 20mm dia high pressure with polythene float and fly nut and with one GI socket 20mm and conncetd items complete incl taking down old u/s one complete all as specified and directed by the Engr-in-Charge.
Maintenance and repair to water supply services of leakage/blockage for GI pipe line of 15mm to 80mm dia including dewatering and necessary excavation returning / filling or cutting, chasing and making of disturbed surfaces as per existing surface and replacing worn out GI pipe max upto 2 mtrs long including cutting threading and replacement of requisite fittings as socket, union, tees, long screwes nipple, hexa nipple , reducer etc complete all as specified and directed by Engr-in-Charge.
Maintenance and repair to leakage/blockage of water supply CI/DI pipe line of 80 mm to 300 dia size including necessary excavation required for taking out burning out lead joint or damaged rubber ring/hole from position and making the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or Tyton joint or necessary fitting required as per site properly and making the pipe line leak proof completly and complete all as specified and directed by Engr-in-charge.
M&L attending any type pump/motor/LT panels/Starters complaint at Boosters and rectify the same, rates are also included for replacement of suitable thimbles any type and any size with nut-bolts, Al/Cu busbar of existing/suitable size, cable jointing with tap and multistranded copper cable piece upto size 35 sqmm upto 2mtr length , gland packing, greasing in pumps/valves with all connected items all as specified by the Engr-in-Charge. Note: Complaint should be rectify within 06 Hrs otherwise a penalty of 500 Rs per day will be imposed.
M&L in replacement of MCCB 4P , 25 KA breaking capacity, 160 Amp, 50 Hz adjustable upto 80% of load thermal and magnectic type with thimbles and nut-bolts, spreaders terminals and rubber seperators complete all as specified and directed.
Description all as per srl item No 29.00 here in before but of size 200A.
Description all as per srl item No 29.00 here in before but of 50 KA breaking capacity, size 400A.
Supply and fix in replacement Aluminium thimbles of size 35-120 sqmm.
Supply and fix in replacement copper thimbles of size 35-95 sqmm.
Complete removal of the wild grass/ vegetation from surrounding area of OHTs, Tubeswells/Boosters and installations area and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified. Note- T&P will be provided by the contractor.
Supply, Install, testing & commissioning factory made outdoor type dust and vermin proof LT panel board cubical double door hinged type compartmentlised of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3.15 mm and internal sheet of 2mm thick machine pressed and angle iron frame 40 mm x 40mm x6mm grouted in PCC 1:2:4 type B1 (20mm graded stone aggregated) powder coated inside and outside complete including 4 pole copper busbar of capacity 600 Amps mounted on porcelain insulators and enclosed in chamber and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with openable shutters on both side and one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter with complete wiring including taking out with the followings:- Note: Contractor will provide LT Panel drawing for approval of Engr-in-charge before placing order.
(a) INCOMING:- (i) MCCB 400A, 4 pole, 415 V , 50 Hz AC, 36 KA adjustable - 02 Nos
OUTGOING:- (i) MCCB 4 pole 415 volts 36 KA breaking capacity rating, 320 Amp adjustable type - 01 No
(ii) TPN 240 volts 10 KA breaking capacity rating , 20 Amp -02 Nos
(iii) Changeover of rating 400A; two incomer and one outgoing terminals- 01 No
Supply, Install, testing & commissioning factory made outdoor type dust and vermin proof LT panel board cubical double door hinged type compartmentlised of suitable size 415 volts, AC 50 Hz fabricated of CRCA sheet 3.15 mm and internal sheet of 2mm thick machine pressed and angle iron frame 40 mm x 40mm x6mm grouted in PCC 1:2:4 type B1 (20mm graded stone aggregated) powder coated inside and outside complete including 4 pole copper busbar of capacity 300 Amps mounted on porcelain insulators and enclosed in chamber and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with openable shutters on both side and one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter with complete wiring including taking ou with the followings:- Note: Contractor will provide LT Panel drawing for approval of Engr-in-charge before placing order.
INCOMING:- (a) MCCB 200A, 4 pole, 415 V , 50 Hz AC, 36 KA adjustable - 02 Nos
OUTGOING:- (i) MCCB 4 pole 415 volts 36 KA breaking capacity rating, 160 Amp adjustable type - 01 No
(ii) TPN 240 volts 10 KA breaking capacity rating , 20 Amp -02 Nos
(iii) Changeover of rating 200A; two incomer and one outgoing terminals-01 No
Notes for item Sr No. 35.00 & 36.00 (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panles through gland. (vi) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
Supply and laying GI pipe light grade of size 50mm with necessary exacavtion and fitting required as in protection pipe for cable to pass under road, trench to the panels by taking down the cable connection properly and making the sutface good after laying the pipe and reconnecting the eletric connections complete all as specified and directed.
Supply and fixing perforated MS cable tray including horizontal and vertical bends, reducer tees, cross member and other accessories as required and duly suspended from ceiling with MS suspenders and including painting etc suitable to accommodate at least 04 runs of upto 25 sqmm three core PVC insulated cables with fasteners 5mm thick 50mm wide or of suitable size complete all as specified and directed.
Supplying, laying, jointing and testing in replacement of existing size with pre-insulated multi standard copper conductor flat of size 25 sqmm, 3 core submersible cable and connected with suitable and required thimbles and nut bolts to panels and Booster pump complete all as directed.
Material & Labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level, filled around with layer of char coal dust and salt and connected to GI earth strip 32 x 6 mm by means of bolt, nut and check nuts and washers of galvanzied iron or steel and other end of the earth strip, connected to test point/equipment/panel and protected by galvanized iron pipe light grade 50mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1:3:6 in chambers, RCC 1:2:4 in pit cover reinforced with 6mm dia deformed bars @ 15cm centre to centre both way including necessary excavation & earth work as directed complete all as shown in electric plate No. 5 of SSR Pt-I. PCC chambers shall be constructed at leasts 1.5 mtr away from the earth electrode and pipe for watering. Note : (i) The test result of earthing should be within standard parameters otherwise no payment shall be done to the contractor. (ii) The cost of re earthing if required shall be beared by contractor.
Demolition of Cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) or under the over head tank/road cutting etc complete all as specified and directed.
M&L broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all specified and directed.
M & L 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in path,paving etc finished even and smooth using extra cement complete all as specified and directed by Engr-in-charge.
Taking down the unserviceable water level indicator with complete accessories like wire rope etc from the over head reservoir complete all as specified.
Material and labour for fabrication of the water level indicator frame made out of MS sheet 2 mm thick of size 1'x12' and hollow ms bar/angle iron 50x50x6 mm including all fixing arrangement incl painting two coat of synthetic enamelled paint over a coat of red oxide primer incl level marking and fixing complete all as specified and directed.
Supply and fixing steel wire rope of size 6 mm dia of best quality(20 mtr length) for fixing of water level indicator, pulley and complete fixing arrangement and 350 mm steel float valve incl testing of valve complete all as specified and directed. Note: (i) All tools and plant, scaffoldingshall be made available by the contractor and nothing extra shall be paid. (ii) The contractor sj\hall submit the certificate of insurance of staff working on OHT before starting the work. The department will not be liable for any mishappeningor accedent occurs during the course of work.
Supply, installation, commissioning in replacement of Busbar panel outdoor type with locking arrangement MS sheet covering 3.15 mm thick pedestal mounted vermin and weatherproof including four legs of 60 cm long of angle iron 40x40x6mm, front openable door having canopy for protection all surfaces painted with powder coated painting, embedding and including 250 Amp rated aluminium bus bars 6 Nos in vertical position duly drilled for making connection with nut bolts of suitable size with colour code tape complete with PCC 1:3:6 type C1 using 20 mm graded aggregate for foundation for legs and dry 63mm aggregate of 75mm thickness around the panel upto 6 sqft after make good electrical connection as specified by EIC. Note: The rate are included with thimbles lugs, nut bolts,PCC foundation and aggregate.
Note :- Amount of credit of Rs. 109750.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
LAKHANPAL ELECTRIC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .