Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹10.5 L+₹26,620 (2.61%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹11.4 L+₹1.2 L (11.7%)Rejected-AOC SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹11.5 L+₹1.3 L (12.7%)Rejected-AOC 37 B SAHEB KRUPA SOC JIVAN CHETAN SCHOOL SAMA ROAD VADODARA GUJARAT PIN 390 008 | VADODARA | GUJARAT | 390008 | L4 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
9 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2021_MES_480942_1
8632
Open Tender
Civil Works
Item Rate
150 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹24,000
Yes
23 Dec 2021
11 Oct 2021
16 Nov 2021
11 Oct 2021
9 Nov 2021
25 Oct 2021
11 Oct 2021 - 25 Oct 2021
60 days
Amount
Taking down carefully copper / Aluminium point wiring (light, fan, socket or power) including fittings and M&L for concealed point wiring with multistranded copper conductor (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code in conduit system of wiring, drawn in & including PVC conduit 25 mm dia with accessories concealed duly fixed with U-Clips, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable (FRLS) as earth wire to common earth and connected to earth dolly drawn in same conduit including cutting chases, finising of slote by means of using CM 1:3 & paint with existing colour and making good disturbed surfaces to match with existing complete. (Note: Fittings shall be measured and paid separately) for One light point controlled by one one/way switch.
All as per item No. 1 above but for One Fan point controlled by one way switch.
All as per item No. 1 above but for One 3 pin 5 Amps socket outlet on same board with other switch.
All as per item No. 1 above but for One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
All as per item No. 1 above but for One light point controlled by two way switches
All as per item No. 1 above but for One bell point controlled by one way switches
All as per item No. 1 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board
S&F switch piano flush type single pole one way 5 Amp 240 Volts complete.
S&F switch piano flush type single pole two way 5 Amp 240 Volts complete.
S&F switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt complete.
S&F switch socket combination 3 pin 5 and 15 Amp 2 in one flush with inbuilt indicating lamp complete.
S&F Bell switch including Bell ding dong type, one way, 240 volts, AC, ISI marked complete.
S&F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete.
M&L in replacement sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including drawn in & including PVC conduit 25 mm dia with accessories concealed duly fixed with U-Clipsaccessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete.
All as above item No. 14 but using 4 Sqmm cable single core copper.
Taking down U/S FTL and S&F 4' 18W LED Tube With Batten with system lumen output of 1800 lumens, System Efficacy should be > 115lm/ W. The Luminaire Should have Cool Day light Color temp of 6500K & CRI>80. Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV. All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accrediated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. The LED tube light conforms to applicable IS and Similar to Crompton LDSL 18-CDL with Master TLED 18W 1800 Lumens etc. complete.
M&L for opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200.1400mm sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 1.7/2.5mfd and making connection with fan capacitor and connector block,Including Painting fan and blade with super enamelled paint of two coats and marking of MES No, transoporting back after repair, assembling the blades and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after fully repair etc. complete. Note : Quoted rate deems to inclusive of rate of fan capacitor, fan bearing and transporatation charges.
S&F ceiling fan with blades, down rods, electronic Regulator and all other accessories 230V,1200mm sweep, min air delivery 210CFM with service value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC), complete. Note : Old fan shall be deposited to AGE E/M store yard through RV.
S&F in repairs TPN DBs Vertical type 4 way with provision for FP as incomer and SP as outgoing, IP 43-IK 09 with metal door and similar to CAT No. 6077 50 of Make Legrand complete.
S&F in repairs sheet metal enclosure for single pole and neutral 08 way 240 voilts, 100 Amp rated bus bar, IP 43 - IK -09 and similar to CAT No. 6077 11 of Make Legrand complete.
S&F in repairs sheet metal enclosure for single pole and neutral 12 way 240 voilts, 100 Amp rated bus bar. IP 43 - IK -09 and similar to CAT No. 6077 11 of Make Legrand complete.
S&F in repairs MCB TPN 63 Amps 35 KA rupturing capacity complete.
S&F in repairs MCB SPN 32 Amps 10 KA rupturing capacity complete
S&F in repairs MCB SP 5 to 32 Amps 240 volts 10 KA rupturing capacity complete
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket with one single MCB SP 20 Amps complete.
M&L in repairs for KAPITRODE Earthing with Cast Iron pipe electrode, 75mm bore, 3.15mm wall thickness , 2.9 metres length,with GI pipe & funnel, buried directly and preferably vertically in ground with top edge not less than 2.9 metres below ground level connected with earthing lead of 25x5mm dia galvanised iron strip all as specified including testing on completion including the material and labour of the following and similar to Make:Kapilansh Dhatu Udyog (P) Ltd : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1 of size 450 x 450 x 450mm with Cast iron cover with suitable handle. (c) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead. (d) Requisite quantity of BFC Compound (bentonide powder) and black cotton soil. (e) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction. .
S&F in replacement wall security light LED type complete with GI bend 1.2 mtr and fixing on wall/pole with clamp, nut & bolt and similar to CAT Part No. LSTO-25-CDL 25watt of Make CG complete
S&F in repairs 7W LED Bulb with system lumen output of 600 lumens, System Efficacy should be > 85lm/ W. The Lamp Should have Cool Day light Color temp of 6500K & supplied with E27 Holder and Similar to Philips Ace Saver complete
S&F in repairs 9 W LED Bulb with system lumen output of 600 lumens, System Efficacy should be > 85lm/ W. The Lamp Should have Cool Day light Color temp of 6500K and Similar to Philips Ace Saver complete.
S&F in repairs14 W LED Bulb with system lumen output of 600 lumens & System Efficacy should be > 85lm/ W. The Lamp Should have Cool Day light Color temp of 6500K and Similar to Philips Ace Saver complete.
S&F in replacement AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, basis current 10 A, Max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards etc. complete.
S&F in replacement 4' feet LED 1X20W LED tube rod on replacing existing 36/40watt fitting at side as per user requirement, with system lumen output of minimum 2000 lumens suitable for G13 holder with single side connection. The Luninaire should have cool daylight color temp 6500K, CRI >80, PF >0.95, Life class of 40,000 burning hrs with 70% lumen maintenance, Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection > 2 KV. LED to mounted on Rod and not directly on the surface of the tube. All the photometrical & electrical parameters must be supported by LM 79-08 test report from NABL accredited LAB or UL switching cycle of 50,000 times. The LED tube light conforms to applicable IS 10322/EN 60598 and similar to CG model No : LT8-20-865-2 complete.
S&F storage, vertical type water heater of capacity 25 ltrs including heating element, all accessories, fixing arrangement etc complete complete. Note : Old one shall be deposited to AGE E/M store yard through RV.
S&F Exhaust Fan Steel Body AC single Phase 230V of size 450mm sweep with blades and frame and louvers complete. Note : Old fan shall be deposited to AGE E/M store yard through RV.
S&F Exhaust Fan Steel Body AC single Phase 230V of size 380mm sweep with blades and frame and louvers complete. Note : Old fan shall be deposited to AGE E/M store yard through RV.
S&F Exhaust Fan Steel Body AC single Phase 230V of size 300mm sweep with blades and frame and louvers complete. Note : Old fan shall be deposited to AGE E/M store yard through RV.
CENTAUR ENGINEERS
M/s. RAMESH NARHARI VALEKAR
Pratik Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .