Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | ₹22.1 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹30.9 L+₹8.8 L (40.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹30.9 L+₹8.8 L (40.0%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹31.0 L+₹8.9 L (40.5%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹31.0 L+₹8.9 L (40.5%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹34.9 L+₹12.8 L (58.1%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹34.9 L+₹12.8 L (58.1%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹35.5 L+₹13.4 L (60.8%)Rejected-Finance | ₹35.5 L+₹13.4 L (60.8%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
7 Mar 2024, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/ MAINT/REPLACEMENT/SERVICING OF LT PANELS, FEEDER PILLAR BOX, MCCBS AND CONNECTED ALLIED ITEMS IN TECH AREA AT (AF) STN AMBALA UNDER GE (AF) AMBALA
2024_MES_641595_1
GE AF/AMB-T-71/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹92,000
Yes
5 Apr 2024
9 Feb 2024
9 Mar 2024
9 Feb 2024
7 Mar 2024
23 Feb 2024
Amount
S&F in replacement Bus Bar Chamber of size 60 x 60 x45 cm suitable of 3 phase 433 Volts outdoor type made out of 3.15 mm thick M S Sheet with 200 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and angle iron stand of size 40 x 40 x 6mm frame grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded mechanically crushed stone aggregate alongwith all necesary cable connections,lugs and cable gland including 2 coat of paint over a coat of red oxide primer complete all as specified and directed.
All as per BOQ srl item No.1.00 here in above but of busbar size 400 Amps complete all as specified and directed.
Supply, installation, testing & commissioning of powder coated compartmentalized LT feeder pillar box / panel, of suitable size, symmetrical with overload, short circuit and earth fault protection, having bus bar chambers with rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz, 3 phase, 4 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in ground with PCC 1:3:6 type C1 painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned and connecting up complete all as specified and as directed
Panel with the following: (i) 1000A rated aluminium bus bar 04 Nos (three phase & Neutral) (ii) MCCB three phase adjustable type with thermal magnetic release 630A 50kA four pole - 1No. (Incoming) (iii) MCCB three phase adjustable type with thermal magnetic release 400A 36kA four pole - 1Nos.(Outgoing) (iv) MCCB three phase adjustable type with thermal magnetic release 315A 36kA four pole - 2Nos.(Outgoing) (v) MCB 240 Volts 40 amps 10KA,SPN-01 Nos (vi) Digital ampere meter and voltmeter
Panel with the following: (i) 600A rated aluminium bus bar 04 Nos (three phase & Neutral) (ii) MCCB three phase adjustable type with thermal magnetic release 400A 36kA four pole - 1No.(Incoming) (iii) MCCB three phase adjustable type with thermal magnetic release 160A 36kA four pole - 3Nos.(Outgoing) (iv) MCCB three phase adjustable type with thermal magnetic release 63A 16kA four pole - 1Nos.(Outgoing) (v) Digital ampere meter and voltmeter
Panel with the following: (i) 400A rated aluminium bus bar 04Nos. (three phase and neutral) (ii) MCCB 3 phase adjustable type with thermal magnetic release 250A 36kA four pole -01No. (Incoming) (iii) MCCB 3 phase adjustable type with thermal magnetic release 125A 25kA four pole -03Nos.(Outgoing) (iv) Digital Ammeter and voltmeter- 01No. (v) LED Indicator lamp in three colour RYB - 01set of 3 (vi) Spare chamber -01No.
S & F in replacement MCCB 100 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S & F in replacement MCCB 125 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S & F in replacement MCCB 160 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S & F in replacement MCCB 200 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S & F in replacement MCCB 250 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S & F in replacement MCCB 400 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S & F in replacement MCCB 630 Amp, 4 pole 50 KA with adjustable thermal release fixed magnetic protection complete all as specified and directed.
S&F in replacement off load change over switch 415 Volt 630 Amp 4 Pole in sheet metal enclosure side handle operated complete all as specified and directed.
S&F in replacement off load change over switch 415 Volt 400 Amp 4 Pole in sheet metal enclosure side handle operated complete all as specified and directed.
Disconnecting and taking out defective UG cable from trench/pole/pipe/floor/wall etc locate the fault, rectify the defects and relaying the XLPE cable UG PVC insulated and overall sheathed aluminium conductor heavy duty LT/HT 1.1/11 KV grade, connecting and testing for any size of cable complete all specified and as directed by Engr-in-Charge. Note: Excavation/earth work shall be measured and paid separaterly under relevant items of schedule.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of cables etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm in soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point as in soil complete all as specified and directed.
M&L for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushioning after punning down ie 18cm only shall be measured for payment.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
S&F GI tubing 80 mm bore light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position complete all as specified and directed.
All as per BOQ srl item No.19.00 here-in-above but of size 50mm dia bore complete all as specified and directed.
All as per BOQ srl item No.19.00 here-in-above but of size 40mm dia bore complete all as specified and directed.
M&L for making bore to road/cement path/hard standing for providing GI pipe 40/50/80mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed.
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 240 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 185 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 150 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 95 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 70 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 50 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 35 Sq mm including taking down old unserviceable cable complete all as specified and directed .
Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 4 core 16 Sq mm including taking down old unserviceable cable complete all as specified and directed .
M&L for locating the fault in LT cable of any size by any method or by manual as per the direction of Engr-in-charge and repair the same by providing straight through or end joints . Note: The joint work and earth work will be measured and paid separately.
Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & F end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm complete all as specified and directed.
All as BOQ Srl Item No.32.00 here-in-above but of size 70 to 150 Sqmm complete all as specified and directed.
All as per BOQ srl item No.32.00 above but of size 25 to 50 Sqmm complete all as specified and directed.
Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & F joint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sq mm complete all as specified and directed.
All as per BOQ srl item No.35.00 here-in-above but of size 70 to 150Sqmm complete all as specified and directed.
All as per BOQ srl item No.35.00 here-in-above but of size 25 to 50Sqmm complete all as specified and directed.
S&F in replacement automatic street light switch for automatic switching of street lights, 8kW equally distributed over 1 phase (7kW/phase) based on LUX level of natural light, infrared sensor based on nature switch along with contactor 60A/phase, MCB SP for input and output 63A, wiring for main load with 3 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to steel poles 9/11m high/long with two coats of synthetic enamel paint over a coat of red oxide primer, in blue & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
S&F in replacement flame proof weather proof energy efficient LED light fitting, 150W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-79, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and directed.
S&F in replacement flame proof weather proof energy efficient LED flood light fitting 60W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-79, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate as in blocks to hold GI extension pipe for Air termination rod and for pole coping complete including necessary use and waste of form work required, complete all as specified and directed.
Repair/Maintenance of any type any size LT panel by opening all incoming and outgoing LT cable connection and reconnecting the LT cable in proper manner by changing all burnt lugs and proper insulation of all nacked cable incl cleaning of panel with blower from inside and removing all grass and bushes around the panel up to 2 mtr distance incl Painting of panel one coat of synthetic enamel paint of grey colour, welding work for repair of broken hinges, doors, complete all as specified and directed.
M&L for copper strip 20x3mm with saddles on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each joint complete all as specified and directed.
Supplying, laying & fixing in replacement copper conductor FRLS PVC insulated unsheathed cable 6.0 sqmm, 3 core, single phase, neutral with earth wire complete all as specified and directed.
All as per BOQ srl item No.45.00 here-in-above but of 10.00 sqmm, 3 core complete all as specified and directed.
Supply Installation Testing and Commissioning of a set of maintenance free tripod earthing system consisting of 3 No. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x50x6mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriter laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed , Resisitivity of the earth enhancing compond should be less than 0.05 ohm meter - an international standard for Earth Enhancement Compound by NABL accredit Lab., complete all as specified and directed. Note : The rate for interconnection of tripod earth with Copper strip of size 20x3 mm and poly carbonate earth pit cover -03 Nos shall deemed to be included in the quoted rates. The Earth result should be less than 1 ohm and the result will be checkedin presence of user rep & MES Rep complete all as specified and directed. If the desired earth resistance is not achieved then entire earthing shall be re-done by contractor without accruing any extra cost to the government.
M&L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead strip 32 x 6 mm size upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc alongwith old unserviceable earthing complete all as specified and directed. Note:- (i) cost of earth strip and GI pipe for protection of earth strip deemed to be included in unit rate up to 7.5 meter. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor till desired earth resistance is not obtained without accruing any extra cost to the Department.
R D Bansal
sanjeev enterprises
Raman Electric Trading Co
M/s Prakash Enterprises
SHARMA ELECTRICAL ENGINEERS
Esha Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .