Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.1 L+₹1.0 L (3.61%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹29.2 L+₹1.2 L (4.15%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹31.3 L+₹3.2 L (11.5%)Rejected-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | L4 | Rejected-Finance L4 | |
| 5 | L5₹38.3 L+₹10.2 L (36.5%)Rejected-Finance DOOR NO 32 939C 1ST FLOOR CITY SCAPE BUILDING CHANGAMPUZHA NAGAR P O SOUTH KALAMASSERY ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | L5 | Rejected-Finance L5 |
Tender Value
₹30 L
EMD Value
₹40,000
Closing Date
27 Sept 2021, 3:00 pmClosed
Deputy Vice President (HCD)
HLL Lifecare Limited, HCD Projects, HLL Bhavan, 6th Floor, Golden Jubilee Block, Poojapura, Thiruvananthapuram - 695012, Kerala, Ph 0471-2775651
Supply, Installation, Testing and Commissioning of Fire Safety System For Dialysis Unit at General Hospital Iringalakuda, Thrissur
2021_HLL_439953_1
HLL/CHO/HCD/GH/IRKLD/FS
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
General Hospital Iringalakuda
Please refer Tender documents.
13 documents required · 13 mandatory
₹2,800
₹40,000
Yes
25 Jul 2023
16 Sept 2021
28 Sept 2021
16 Sept 2021
27 Sept 2021
16 Sept 2021
Amount
1 FIRE PROTECTION WORKS
AUTHORITY APPROVALS AND COORDINATION: Preparation of all drawings, submitting and getting approval from fire department, submitting of completion certificates and arranging inspection, getting sanction, etc. for commissioning of the whole installation in the premises.(All statutory payments will be reimbursed with original receipts.)
25mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications. The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
32mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications.<br>The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
40mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications. The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
50mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications.<br>The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
65mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications.<br>The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
80mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications.<br>The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
100mmdia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications. The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
150mm dia: Supply, installation, testing and commissioning of fire fighting system pipe work for Fire Brigade Inlet, Wet Risers , sprinklers etc with MS C class pipe as per IS:1239 with all fittings like bends tees, flanges, nuts bolts, washers etc. Supports for the underground pipes with anchor blocks, angular supports for above ground pipes not less than every three meter intervals or as required by the consultant/client. The welding should be as per the functional requirement of the System, and the welded pipes should withstand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications.<br>The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
Supply, installation, testing and commissioning of 50mm dia sprinkler drain pipe work for sprinkler system with MS C class pipe as per IS:1239 with all fittings like bends, tees, flanges, nuts bolts, washers etc. The welding should be as per the functional requirement of the System, and the welded pipes should with stand 20Kg/cm.sq for 24 hours. The welding accessories should be in accordance with the IS specifications.<br>The above ground pipe are to be applied with two coats of zinchromate primer and two coats of enamel paint of approved colour.
Supply, erection, testing & commissioning of single headed gunmetal oblique type landing/hydrant valve (as per IS:5290) with 63mm outlet gunmetal instantaneous male/female coupling with rubber/Plastic cap duly binded with stainless steel wire and 15m long flexible hose (as per IS:636-type A) etc. complete as specifie
Supply, erection, testing & commissioning of Fire hose real cabinet (16Guage fire hose cabinet 750x750x300mm with double door and in kept of two nos with fully powder coated.) including automatic swinging type 25mm (nominal internal) dia & 30m long first aid flexible hose reel with all necessary fittings & ball valve (IS:12585 & IS:884), standard SS branch pipe with nozzle of 20mm (IS:903) suitable to fit with standard instantaneous type 63mm coupling, 4Kg dry powder fire extinguisher and 4.5 Kg CO2 extinguisher all as specified and as shown on drawings and complying to authority regulations and relevant standards (Refer FHRC)
Supply, erection, testing & commissioning of (Pendant Type) sprinkler heads with all supports, fixings and fittings all as specified and as shown on drawings and complying to authority regulations and relevant standards
Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in accordance with the drawings and specifications. 4 kg ABC Dry chemical powder extinguisher
Supply, erection, testing & commissioning of Fire extinguishers & Accessories all in accordance with the drawings and specifications.CO2 fire extinguisher 4.5kg
MULTI SENSORS: Supply, Installation, Testing and Commissioning of Intelligent Addresable Multi Sensor with optical smoke element and thermal element. The detector shall have facility to mount in different comprehensive environment like Hostile environment, Parking Garage, HVAC Ducts, Precious storage, Transformer rooms, Warehouse, Dormitory and normal working environments
MANUAL PULL STATION: Supply, Installation, Testing and Commissioning of analogue addressable type Manual pull station at indicated locations with necessary termination as per acceptable specifications and full ready for operation.
SHORT CIRCUIT ISOLATOR MODULE: Supply, Installation, Testing and Commissioning of Short Circuit Isolator Module for isolating the affected segment of the circuit, allowing the remaining devices to continue operation.
FIRE SURVIVAL CABLE : Supply, Installation, Testing and Commissioning of Fire Survival Cables conforming to BS: 7846 armoured 2 core x 1.5 sqmm.
FIRE FIGHTING
Supply and placed in position of Gun metal Branch Pipe, 63mm female instantaneous inlet, male threaded outlet, as per IS:903 with ISI mark complete with hexagonal base nozzle.
Supplying, installing and testing of instantaneous pattern Gun metal Supplying, installing and testing of instantaneous pattern Gun metal Single Headed Hydrant valve of 63mm Dia, oblique type, instantaneous hose coupling adaptor as per IS:5290 with ISI mark complete with PVC blank cap etc. of 63mm Dia, oblique type, instantaneous hose coupling adaptor as per IS:5290 with ISI mark complete with PVC blank cap etc.
25 MM - Supplying, installing and testing of forged brass Ball valves with fittings of screwed end type.
80 mm Dia - Supplying, Installing and testing CI Non return valve slim seal standard confirming to IS 13039 with required flanges, nuts, bolts etc. complete.
100 mm Dia - Supplying, Installing and testing CI Non return valve slim seal standard confirming to IS 13039 with required flanges, nuts, bolts etc. complete. 4
Supplying, Installing and testing of single acting Pressure Switch. 25 mm DIA
Supplying, Installing and testing of single acting Pressure Gauge.<br>25 mm Dia
Supplying, Installing and testing of single acting Air Release Valve with screwed inlet 25 mm dia etc.
80 mm DIA - Supplying, Installing and testing CI Butterfly valve slim seal standared lever operated type confirming to IS 13039 with required flanges, nuts, bolts etc. complete.
100 mm DIA - Supplying, Installing and testing CI Butterfly valve slim seal standard lever operated type confirming to IS 13039 with required flanges, nuts, bolts etc. complete.
JOCKEY PUMP:- Supply, Installation, Testing, & Commissioning of 10.8M3/Hr@ 70 MWC Jockey pump, monobloc type rated for 7.5 HP, with cast iron casing bronze impellers etc pump to a squirrel cage induction motor, totally enclosed fan cooled type rated for 415V, 50Hz, 2900 RPM (180lpm)including supply of all accessories as per the functional requirements of OEM.
ELECTRIC MOTOR DRIVEN FIRE PUMP(MAIN ):- Supply, Installation, Testing and commissioning of main fire fighting pumps of horizontal centrifigal end suction type rated for 136.8M3/Hr@ 70 MWC, high efficiency volute type with cast iron casing, bronze impeller, pump coupled type with a squirrel cage induction motor, Totally Enclosed Fan Cooled type rated for suitable HP(30HP) at 2900 RPM, (1620lpm)with a supply condition of 415v, 3 phase, 50 HZ, foot mounted type including installation of all accessories as per the functional requirements of OEM
DIESEL ENGINE DRIVEN FIRE MAIN PUMP STANDBY):- Supply, Installation, Testing and commissioning ofDIESEL ENGINE PUMP fire fighting pumps of horizontal centrifigal end suction type rated for 136.8M3/Hr@ 70 MWC, high efficiency volute type with cast iron casing, bronze impeller, pump coupled type with a squirrel cage induction motor, Totally Enclosed Fan Cooled type rated for suitable HP at 2900 RPM, (1620lpm)with a supply condition of 415v, 3 phase, 50 HZ, foot mounted type including installation of all accessories as per the functional requirements of OEM.
Supply,installation and testing of emergency exit systems with battery backup
Supply, installation and testing of Electronic Hooter (Sounder) as per standard specification.
Fire Alarm System - Supplying, installing and testing of addressable Main Fire alarm control panel with single loop capacity, with LCD-MCF-10 indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free battery back up for 24 hours normal operation and 15 minutes alarm operation. The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.
FIRE BRIGADE'S INLET:-Supply, installation, testing and commissioning of Fire Brigade Inlet connection with 3 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 100 mm dia.etc. Pipe manifold shall be connected to wet riser main.
Foot valve-Supply, installation, testing and commissioning of foot valve 80 mm dia.etc.
Foot valve-Supply, installation, testing and commissioning of foot valve 100 mm dia.etc.
AIR CUSSION VESSEL:-Supply, installation, testing and commissioning of Air cussion vessel arranged on 200 mm dia.etc.
Supply and placed in position of Controlled Percolated Hose conforming to IS: 636, 63mm dia, 15 Mtrs length with gunmetal heavy duty 63 mm pair of male and female couplings etc.
KKL FIRE EQUIPMENT
PAN PACIFIC ENGINEERING SERVICES PRIVATE LIMITED
TI John and Sons
Allies Fire Systems Pvt Ltd
COCHIN FIRE TECH INDIA PVT. LTD.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .