Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.1 L+₹3,012 (0.99%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹3.6 L+₹57,663 (19.0%)Rejected-Finance 125 SHIVAJI NAGAR SAVARKUNDLA SAVARKUNDLA GUJARAT 364515 | AMRELI | GUJARAT | 364515 | L3 | Rejected-Finance L3 | |
| 4 | L4₹3.6 L+₹60,962 (20.1%)Rejected-Finance VILL CHHOTO CHAND GHAR PO BARA CHAND GHAR DIST NADIA PIN 741196 | 741196 | L4 | Rejected-Finance L4 | |
| 5 | L5₹3.7 L+₹63,205 (20.9%)Rejected-Finance DUCKBANGLO JAGADISHPUR RAJARHAT NORTH 24 PGS KOLKATA 700135 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700135 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹7,214
Closing Date
6 Jan 2025, 8:22 amClosed
AE, North East Electrical Sub-Division, PWD
Purta Bhawan, Room No 112 ,Salt Lake
Electrical installation work at proposed Glass Box at 1st tier of Hockey Stadium in VYBK Campus Salt Lake Kolkata
2024_WBPWD_791706_1
WBPWD/AE/NEESD/e-NIQ-23/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
VYBK Campus Salt Lake
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,214
9 Apr 2025
27 Dec 2024
8 Jan 2025
28 Dec 2024
6 Jan 2025
28 Dec 2024
Amount
Electrical Installation Work Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment- 6 Way HTPN DB (Make- Legrand / Schneider / ABB/ Siemens) Incommer 415V 63A 4 pole MCB Isolator - 1 No, Outgoing 1) 10A- 32A ,10KA, SP MCB - 12 Nos 2) 40A ,10KA,SP MCB - 6 Nos
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment- 2+8 Way SPNDB (Make- Legrand / Schneider / ABB-Elegance Series/ Siemens) Incommer 230V 40A DP MCB Isolator - 1 No, Outgoing 1) 6A- 32A,10KA, SP MCB - 8 Nos
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Finolex/ Gloster/ Polycab/ RR Kabel/ Havells) of the following sizes through 19 mm dia, 3 mm thick Polythene pipe recessed on wall, ceiling, etc. as required, including supply & laying of heavy gauge 19 mm dia, 3 mm thick polythene pipe embedded in wall by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG and making necy. connection as required, as per G.S. 3 x 22/0.3 (1.5 sq. mm.) as ECC (interconnection wire)
Do---------Do---------- 2 x 36/0.3 (2.5 sq. mm.) + 1 x 22/0.3 (1.5 sq. mm.) as ECC (computer and power plug)
Do---------Do---------- 2 x 56/0.3 ( 4 sq. mm. ) + 1 x 36/0.3 (2.5 sq. mm.) as ECC ( Geyser and AC indoor)
Do---------Do---------- 2 x 80/0.4 ( 10 sq. mm. ) + 1 x 84/0.3 (6 sq. mm.) as ECC ( TPNDB to SPNDB)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as follows:- 2.5 sq. mm. as ECC
Do---------Do---------- 4 sq. mm. as ECC
Do---------Do---------- 10 sq. mm. as ECC
Do---------Do---------- 6 sq. mm. as ECC
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) and 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & Fixing 240 V, 1 no. 16 A, 3 pin Modular type plug socket with 1 no. 16A Modular type switch & 1 nos 3 pin 6A Plug moduler type socket with 1 no 6A modulet switch (Brand approved by EIC), without plug top 6 Module GI Modular type switch board with 6 Module top cover plate to be flushed in wall or decorative wall panel/ fixed on wall(where cutting is not possible) as per direction of E.I.C incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (as combination set of 16 A plug socket and 6 A socket)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC) Average run 9 Mtr
Supply and Fixing of decorative type LED fittings after cutting the gypsum/ metal board & mending good the damages to original finish as per direction of EIC as follows (Make-Philips / WIPRO/Crompton Greaves/Havells). (a) Recess Mounted circular LED round slim down lighter made from the die cast aluminium body having system lumen output not less than 900 lumen, power input not more than 12/15 watt colour temparature 4000K / 5000K (as per site requirement), CRI > 80, IP rating 20 or better.
Do---------Do---------- (b) Recess Mounted square 2 ft x 2 ft 36 watt LED fitting with energy efficient diffuser having system lumen output not less than 3600 lumen, colour temparature 4000K / 5000K (as per site requirement), CRI > 80, IP rating 20 or better, lumen efficiency not less than 100 lumen/watt.
Supplying and fixing double-door (2+8) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. (Make - Legrand/ABB/L&T/Siemens)---1 Set. a) Supplying and fixing 240 V 32A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection---1 no. (Make - Legrand, cat - 408636) b) Supply and fixing of Indication Lamp. (Make - Legrand, cat - 412927)--1 set. c) Supply and fixing of 2 pole 25 A Contactor. (Make - Legrand, cat - 412544)---2 Nos. d) Supply and Fixing of 16 A 230 V Analog Timer Switch. (Make - Legrand, cat - 412813)--1 No. e) Supply and Fixing of 230 V Auto/Manual Bypass Toggle Switch. - 1 No. Inter connection of the above mention equipment should be done by using 4 sq. mm. copper wire such that MCB, Indication lamp, Timer switch, Contactor & Auto/Manual Toggle switch as per direction by EIC.
Supply & Laying of 1.1 KV grade XLPE insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith. (cost includes Supply & Fixing of straight through joint, if required, as per direction of EIC) (Make - Gloster/ Polycab/ Havells/ KEI/ Polycab)----4 core 35 sq mm cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and paintin
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below incuding S & F of end finishing :
(All Rates are inclusive of all taxes and duties)
Messrs HI- Q - ENTERPRISE (BID ID -5931498)
S. N. ENTERPRISE (BID ID -5949807)
ASIM KRISHNA MODAK (BID ID -5949562)
RIDDHI (INDIA) (BID ID -5950277)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .