Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC RAJA RAM MOHAN ROAD HAKIMPARA SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.0 L+₹16,000 (1.08%)Rejected-Finance ATUL PRASAD SARANI E V PALLY HAKIMPARA SILIGURI | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹15.5 L+₹65,616.17 (4.43%)Rejected-Finance RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S. P K ENTERPRISE L1 | M/S DAWN ELECTRICAL INDUSTRIES L3 | RAJESH ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.01Supply, delivery of floor mounting cubicle compartmentalized 415 volt. 50Hz. Dust & moisture proof L.T distribution panel board fabricated from 16 SWG CRCA sheet for main L.T panel. The panel should have adequate strength and space to accommodate the incoming switches bus bars with all interconnection in between the switches & bus bars with solid copper rod/flexible wire of suitable capacity. The incoming terminals of MCCB/SFU should be provided with extra copper bar of suitable capacity for smooth termination of double feeders. The panel board should be painted by powder coated paint and the lay out diagram of panel board should be approved by EIC before manufacturing. The panel board should comprise with the followings gadgets :- | ||||||
| 1.02Incomer i) S/F of 415 Volts 315 Amp, 4P MCCB, 36KA with castle locking arrangement, .--2No (Make L&T-Cat No. CM98401OOQOOG/ABB/Siemens). Bus bar chamber :- ii) do-do 600 Amp capacity 99.9% - 99.5% electrolytic tinned copper 4 bar bus bar of suitable dimension mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu wires------1set. (iii) Bus Coupler, 415 Volts, 315 Amp, 4P MCCB, 36 KA with castle locking arrangement.-01 No (Make L&T-Cat No. CM98401OOQOOG/ABB/Siemens). | ||||||
| 1.03Outgoing i)S/F of 415V, 250A DIN type SFU ---3nos (Make L&T/ABB/Siemens).- (ii) S/F of 415V, 200 A DIN type SFU ---1no (Make L&T/ABB/Siemens).- (ii) S/F of 415V, 125 A DIN type SFU ---2nos (Make L&T/ABB/Siemens).- | ||||||
| 1.04 | metering arrangement
a)0-500V digital volt meter----2no.
b)0-300A flush mounting digital ammeter(AE) with selector switch—2no.
c) 300/5A ratio C.T's----2 x 3nos.
d)250V LED(RYB) source indicating lamps with sliding control fuses and selector swithches-----2 x 3nos.
e) EI danger board. | 1 | Each | 2,85,000 ₹2,85,000 Lowest | 2,96,000 ₹2,96,000 | 2,98,000 ₹2,98,000 |
| 2.00 | Main Switch, Bus bar
Supplying & fixing 4 bar 415 V, 315A, sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) | 1 | Each | 6,907 ₹6,907 Lowest | 6,907.95 ₹6,907.95 | 6,907 ₹6,907 Lowest |
| 3.00 | Supplying & fixing 4 bar 415 V, 250 A, sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) | 1 | Each | 5,550 ₹5,550 | 5,023 ₹5,023 Lowest | 5,550 ₹5,550 |
| 4.00 | Supplying and fixing 415V, 315 ATPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make- L & T, Siemens, Schnider] | 1 | Each | 17,110 ₹17,110 Lowest | 18,076.58 ₹18,076.58 | 17,110 ₹17,110 Lowest |
| 5.00 | Supplying and fixing 415V, 200 ATPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make- L & T, Siemens, Schnider] | 1 | Each | 12,120.5 ₹12,120.5 Lowest | 13,186.68 ₹13,186.68 | 12,120.5 ₹12,120.5 Lowest |
| 6.00 | Supplying and fixing 415V, 200A, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nutsbolts etc [Make- L&T, Siemens, Achnider] | 1 | Each | 10,950 ₹10,950 Lowest | 12,805 ₹12,805 | 10,950 ₹10,950 Lowest |
| 7.00 | Supplying and fixing 415V, 125A, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make- L&T, Siemens, Havells] | 2 | Each | 9,340 ₹18,680 Lowest | 10,383.28 ₹20,766.56 | 9,340 ₹18,680 Lowest |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
27 Jan 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, DARJEELING ELECTRICAL DIVISION
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
EI work for interconnection and load distribution between 160 KVA DG and 200 KVA DG at Siliguri District Hospital.
2023_WBPWD_443221_1
WBPWD/EE/DED/e-NIT- 53 of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
28 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹28,000
23 Feb 2023
9 Jan 2023
30 Jan 2023
9 Jan 2023
27 Jan 2023
9 Jan 2023
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_880989.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .