Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹7.1 L
Closing Date
18 Mar 2026, 6:00 pmClosed
Commissioner, Surendranagar Municipal Corporation, Surendranagar
CONSTRUCTION OF JHALAWAD MEMORIAL & HERITAGE MUSEUM PHASE 1 DISTT. SURENDRANAGAR (2nd Attampt)
284087
Tender Notice No. 23 / City Eng / 2025-2026
Open
Civil Works
Works
Surendranagar
3 documents required · 3 mandatory
₹14,160
Surendranagar Municipal Corporation
₹7.1 L
8 Mar 2026
8 Mar 2026
8 Mar 2026
18 Mar 2026
8 Mar 2026
Surendranagar Municipal Corporation
NAME OF PROJECT : Construction of Jhalawad Memorial & Heritage Museum Phase
Bill of Quantities
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Demolition including stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift. For R.C.C. work, brick work, tile
work, bathroon & toilet fixtures, windows & Doors and also ventilation, etc
1 complete as per detailed, directed & approved by the consultant / EIC Job 1.00 404,000.00
Carryout Soil Investigation work including exploratory drilling of 150 mm dia
borehole in all sorts of soil& Rock up to 10m depth from G.L, collecting
undisturbed samples at an interval of 1.5 m. depth, determining depth of
water table etc. Conducting necessary laboratory tests for all type of
classification and determination of soil parameters necessary for
2 determining pile capacity like density, shear and consolidation parameters Job 1.00 44,844.00
etc., including submission of report in three copies covering investigation
data and recommendation for SBC etc. all as per specification at required
Contour survey work for prepaing contour maps by taking cross-section at
every 30M. intervals including all, labour materials and instruments. This
item includes the submission of autocad file of total site survey, etc
complete as per detailed, directed & approved by the consultant / EIC
Excavation for foundation upto 1.5 m depth including sorting out and
4 stacking of useful materials and disposing off the excavated stuff upto 50 Cmt 3051.00 117.08
Meter lead.(A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting
out and stacking of useful materials and disposing off the excavated stuff up
5 to 50 Meter lead.(C) Hard Murrum, etc. complete as per detailed & directed Cmt 1681.00 273.54
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
foundations etc. in layers not exceeding 20 cm. in depth consolidating each
6 disposited layer by ramming and watering. Cmt 3763.00 130.39
Filling in foundation and plinth with murrum or selected soil in layers of
7 20cm. thickness including watering, ramming and consolidating etc. Cmt 2273.00 282.02
complete. (more than 10 ton)
Carring out plinth treatment to post construction /existing structure by
spraying chemical solution for termite control treatment including labour
and material consistment with I.S.I specification. Using Chlordene and
Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one percent
is recommended i.e one litre 20 EC chemical emulsion with 19 liter give 1%
8 concrentration inclusive of one litre chemical emulsion appication at the rate Smt. 775.00 56.63
of 5 Litre chemical /Sqm of sur face is recommended as per I.S
Providing and laying cement concrete 1:2:4 (1- Cement : 2-Coarse sand : 4-
9 graded stone aggregates 20 mm nominal size) and curing complete Work in Cmt 440.00 3,631.49
(A) Foundation and Plinth
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforcement for
10 reinforced concrete work in (A) Foundations, footings, Base of columns and Cmt. 339.00 4,626.81
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
11 reinforced concrete work in (B) Walls below the plinth Cmt. 26.50 6,655.90
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
12 reinforced concrete work in (B) Walls, for Ground floor Cmt. 8.00 6,655.90
ARCHITECT: ARG Creation Pvt. Ltd. 1 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Walls, Extra for additional lift of concrete for
all R.C.C. work above floor two level excluding cost of reinforcment for First
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Walls, Extra for additional lift of concrete for
all R.C.C. work above floor two level excluding cost of reinforcment for
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforcement for
15 reinforced concrete work in columns below plinth Cmt. 51.50 5,214.63
Providing and laying controlled cement concrete M:250 and curing complete
including cost of necessary, form work, compacting with vibrator curing
centering & shuttering in true line and level etc, but excluding the cost of
reinforcement for RCC work in (D) For Columns for any type of cross
sectional area at Ground Floor lvl. etc., for any type of cross section area
complete as directed by E. I. C.
Providing and laying controlled cement concrete M:250 and curing complete
including cost of necessary, form work, compacting with vibrator curing
centering & shuttering in true line and level etc, but excluding the cost of
17 reinforcement for RCC work in (D) For Columns for any type of cross Cmt. 30.50 7,059.27
sectional area at First Floor lvl. etc., for any type of cross section area
complete as directed by E. I. C.
Providing and laying controlled cement concrete M:250 and curing complete
including cost of necessary, form work, compacting with vibrator curing
centering & shuttering in true line and level etc, but excluding the cost of
reinforcement for RCC work in (D) For Columns for any type of cross
sectional area at Terrace Floor lvl. etc., for any type of cross section area
complete as directed by E. I. C.
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforcement for
19 reinforced concrete work in Beams upto floor two level: PLINTH BEAM / Cmt. 112.50 6,177.16
Ground beam / Tie beam
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforcement for
20 reinforced concrete work in Lintels / Copping upto floor two level. Cmt. 16.00 6,120.60
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforcement for
21 reinforced concrete work in Chajjas upto floor two level. Cmt. 9.00 6,832.65
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
22 reinforced concrete work in © Slabs upto floor two level. : Grade slab Cmt. 128.50 4,749.02
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in © Slabs, landing, shelves, Balconies, Lintels,
Beams, Girders and Cantilever upto floor two level. :Ground Floor Staircase
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in © Slabs, landing, shelves, Balconies, Lintels,
Beams, Girders and Cantilever upto floor two level. : First Floor Staircase
ARCHITECT: ARG Creation Pvt. Ltd. 2 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork and excluding the cost of reinforcement for
reinforced concrete work in © Slabs, landing, shelves, Balconies, Lintels,
Beams, Girders and Cantilever upto floor two level. : Terrace Floor Staircase
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost ofreinforced concrete
26 work in © Beams upto floor two level. . : GROUND FLOOR BEAM Cmt. 82.50 6,612.47
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost ofreinforced concrete
27 work in © Beams upto floor two level. . : FIRST FLOOR BEAM Cmt. 61.50 6,652.05
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost ofreinforced concrete
28 work in © Beams upto floor two level. . : TERRACE FLOOR BEAM Cmt. 13.00 6,691.63
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforced concrete
29 work in (C) Slabs upto floor two level. :Ground floor Slab Cmt. 106.00 6,445.82
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforced concrete
30 work in (C) Slabs upto floor two level. :First floor Slab Cmt. 93.00 6,485.40
Providing and laying controlled cement concrete M.250 and curing complete
Including the cost of formwork but excluding the cost of reinforced concrete
31 work in (C) Slabs upto floor two level. :Terrace floor Slab Cmt. 15.50 6,524.98
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending,
32 binding and placing in position complete upto all floor level. kg 143125.00 76.21
Brick work using common burnt clay building bricks having crushing
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
33 Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional Cmt. 33.00 4,051.78
Brick work using common burnt clay building bricks having crushing
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional Extra for brick work
in superstructure above plinth level upto floor two level (B) Conventional
ARCHITECT: ARG Creation Pvt. Ltd. 3 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and fixing of AAC Panels of Thickness 125mm / 100 mm (Brand
Name- ZmartBuildwall by NXT Bloc) in line and level with consideration of
below Specification, Inculding cutting, groove filling with water proof
bonding sealent / Putty , at all height work as per IS : 6072 having a tongue
groove edge. The rate should also be include of all L clips, power tools
nacessary to cutting jointing and finishing work including PPEs, Filling of
joint with the bonding compound and wire mesh overlapping at both the
sides about 50 mm. Mode of measurement would be a finish surface only.
The rate also include the cutout making at site in pre designing factored
complete as per detailed & approved by the consultant & directed by EIC.
PARAMETERS SPECIFICATIONS
Density 550 to 750 Kg/m3
Compressive Strength > 4 N/mm2
35 Flexural Strength > 1 N/mm2 Smt 1213.00 3,374.39
Tolerence + - 1mm
Fire Resistance 4 Hours (100 mm)
STC Rating 43 db(100 mm)
MEP Installation difficulty level Very Low
Thermal Conductivity 0.12 (W/K-m)
Coefficient of Thermal Expansion 8x10-6/K
Modulus of Elasticity 2190 Mpa
Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in cement mortar 1:5 ( 1- Cement : 5 -
coarse sand ) in foundation and plinth (B) Conventional Extra for half brick
36 masonry in superstructure above plinth level upto floor two level. (B) Smt 10.00 641.16
Providing & Fixing the Chikenmesh - 20 guage(Crimp Jali) of approved size
applying between the RCC and masonry junction in proper line, level and
plumb with all material, labour, tools, tackles and equipment. Including
providing and fixing the jali with nails, etc complete as directed by the site-
Providing & laying average 18-20mm thick double coat water proof smooth/
wired finish cement plaster on sides of masonry work/ block wall/ RCC wall,
12 to 15mm thick first coat in CM 1:3 (1 cement : 3 coarse sand) by
spraying, second coat of 6mm of CM 1:3 (1 cement : 3 fine sand) and mixing
water proofing compound powder & liquid of approved make in
recommended proportions (by manufacturers) in both coats including
finishing with a flooting coat of neat cement slurry etc complete for all floor.
and shall be guaranteed for minimum period of 10 years after handing over
the completed building by the main contractor to be finished as directed.
38 Stamp paper guarantee 10 years to be furnished before receiving any Smt 380.00 334.48
payment from the client. Waterproofing powder & liquid of approved make
recommended proportions is to be applied before each coat and final
finishing coat. (Item shall be operated for water retaining structures, sunks,
basement walls & Slab(10mmthk.) and other places specified by Architect/
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering upto floor two level and
39 finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) Smt 103.00 163.85
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor two level and finished even and smooth in
40 (ii) Cement mortar 1:4 (1-cement :4-sand) Ground floor level Smt 707.00 123.13
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor two level and finished even and smooth in
41 (ii) Cement mortar 1:4 (1-cement :4-sand) First floor Smt 620.00 171.34
ARCHITECT: ARG Creation Pvt. Ltd. 4 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor two level and finished even and smooth in
42 (ii) Cement mortar 1:4 (1-cement :4-sand) Second floor Smt 104.00 219.54
20mm thick sand faced cement plaster on walls upto height 10 metres
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) etc. complete as approved and directed by Consultant / EIC.
Washed stone grit plaster on exterior walls height upto 10 metre above
ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement
: 4 coarse sand ), furrowing the under layer with scratching tool, applying
cement slurry on the under layer @ 2 Kg of cement per square metre, top
layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone
chipping 10 mm nominal size), in panels with groove all around as per
44 approved pattern, including scrubbing and washing the top layer with Smt 931.00 1,173.87
brushes and water to expose the stone chippings ,complete as per
specification and direction of Engineer-in-charge (payment for providing
grooves shall be made separately).
Forming groove of uniform size in the top layer of washed stone grit plaster
as per approved pattern using wooden battens, nailed to the under layer,
including removal of wooden battens, repair to the edges of panels and
finishing the groove complete as per specifications and direction of the
Engineer-in-charge :
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of
cement mortar 1 :5 (1 cement : 5 coarse sand), including pointing with
cement mortar 1 :2 (1 cement: 2 stone dust) with an admixture of pigment
44.2 to match the shade of stone. Red sand stone Smt 242.00 1,541.31
Stone work (machine cut edges in veneer work) for wall lining upto 10 m
height, backing filled with a grout of 12 mm thick cement mortar 1 :3 (1
Cement : 3 coarse sand) and jointed with Cement mortar 1 :2 (1 cement :
stone dust), including grinding with hand grinder on joints, rubbing and
polishing complete. (To be secured to the backing and the sides by means of
45 cramps and pins which shall be paid for separately). Dressed sand stone of Smt 456.00 4,151.10
approved shade by architect and EIC complete as per specification including
all tools. Sand stone
Supplying and fixing of GRC Jharokha 1 exact as per Image & specification
45.01 Size and complete as per detailed drawing & Directed by EIC. Smt 16.00 9,780.84
Supplying and fixing of GRC Jharokha 2 exact as per Image & specification
45.02 Size and complete as per detailed drawing & Directed by EIC. Smt 72.00 9,780.84
Supplying and fixing of GRC Column 1 exact as per Image & specification
45.03 Size and complete as per detailed drawing & Directed by EIC. Smt 48.00 8,694.08
Supplying and fixing of GRC Column 2 exact as per Image & specification
45.04 Size and complete as per detailed drawing & Directed by EIC. Smt 22.00 8,694.08
Supplying and fixing of GRC Arch 1 exact as per Image & specification Size
45.05 and complete as per detailed drawing & Directed by EIC. Smt 36.00 7,607.32
Supplying and fixing of GRC Arch 2 exact as per Image & specification Size
45.06 and complete as per detailed drawing & Directed by EIC. Smt 39.00 7,607.32
Supplying and fixing of GRC Jali exact as per Image & specification Size and
45.07 complete as per detailed drawing & Directed by EIC. Smt 6.00 8,694.08
Supplying and fixing of GRC Moulding 1 exact as per Image & specification
45.08 Size and complete as per detailed drawing & Directed by EIC. Rmt 270.00 7,607.32
ARCHITECT: ARG Creation Pvt. Ltd. 5 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Supplying and fixing of GRC Jhinjhuwada style arch exact as per Image &
45.09 specification Size and complete as per detailed drawing & Directed by EIC. Smt 18.00 29,342.52
Supplying and fixing of GRC Railing 1 exact as per Image & specification Size
45.10 and complete as per detailed drawing & Directed by EIC. Smt 44.00 5,899.41
Supplying and fixing of Precast lime Thambli exact as per Image &
45.11 specification Size and complete as per detailed drawing & Directed by EIC. Nos. 750.00 1,515.00
Supplying and fixing of GRC Dome type 1 as per Image & specification and
45.12 Size and complete as per detailed drawing & Directed by EIC. Nos. 2.00 98,681.04
Providing and fixing 18 mm thick gang saw cut, mirror [Hi-Gloss] polished at
all exposed Surface, Pre-moulded and pre-polished, machine cut Granite of
any colour and shade, & finish, as per detailed by architect /Consultant for
flooring, dado skirting, cladding, steps and risers, kitchen platforms, vanity
counters, window & Door sills , fascias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick mortar 1:4 (1 acid
proof cement : 4 coarse sand). And In dado/skirting on In dado/skirting on
12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand), joints treated
46 with white cement, mixed with matching pigment, epoxy touch ups, Smt 66.00 3,504.70
including BSpacer tape 6.4 mm thick x 4 TO 6 mm as per detailed groove,
rubbing, curing, moulding and polishing to edges to give high gloss finish as
per concept etc. complete at all levels.
Providing and fixing 18 mm thick gang saw cut, Ruff [Send-blasted-
LAPORTA] polished in pattern & at all edges should be molded in rquired
finish, Pre-moulded and pre-polished, machine cut Granite of any colour
and shade, & finish & texture, as per detailed by architect / Consultant, for
flooring, dado skirting, cladding, steps and risers, kitchen platforms, vanity
counters, window sills , fascias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick mortar 1:4 (1 acid
proof cement : 4 coarse sand). And In dado/skirting on In dado/skirting on
47 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand), joints treated Smt 1164.00 4,146.56
with white cement, mixed with matching pigment, epoxy touch ups,
including Spacer tape 6.4 mm thick x 4 TO 6 mm as per detailed groove,
rubbing, curing, moulding and polishing to edges [Ruff [Send-blasted-
LAPORTA] polished] to give high gloss finish as per concept etc. complete at
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base
of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including dismentaling of existing
48 flooring and jointed with color cement slurry including finised with flush Smt 26.00 1,204.20
pointing & cleaning the surface etc. complete for light shade / Dark Shade
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base
of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including dismentaling of existing
49 flooring and jointed with color cement slurry including finised with flush Smt 42.00 1,397.83
pointing & cleaning the surface etc. complete for antiskit
Providing and laying Vitrified tiles 8 to 10 mm thick, 24'' x 24'' in skrting
50 risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3- Smt 360.00 1,141.45
coarse sand) and jointed with white cement slurry
Providing and laying polished Kota stone slab flooring over 20mm (Average)
thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-
Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry
51 mixed with pigment to match the shade of slab including rubbing and Smt 26.00 971.95
polishing etc. complete. (A) 25mm thick
ARCHITECT: ARG Creation Pvt. Ltd. 6 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and fixing 0.70 meter wide sandwich type platform including
supplying and fixing granite stone 18 mm thick mirror polished stones in
top and side position and vertical strip at front over 25 mm thick polished
kota stone platform fixing in top and sides and intermediates supports
52 fixing with cement mortar and adhesive and finishing including making Smt 4.00 7,910.56
recess for Kitchen/ Laboratory sink etc. complete as approved and directed
by Consultant / EIC.
Providing and fixing 35 mm thick ISI marked flush door shutters conforming
to IS : 2202 (Part I) Thick Both Side Laminated Water Proof FLUSH DOOR
SHUTTERS of ARCHIDPLY/ CENTURY make including first class hardwood and
cross band, block board core
with plywood face panels, Approved Granite frame as per detail, Hylandpine
code -1208 1mm thk. laminate of Sunmica make including "Lx. Premium"
53 Platinum Finish Accessories As per Architect Concept & Design., ISI make, Smt 78.00 8,776.90
including providing and applying primer coat and two coats of oil painting
OR French polishing of Asian make to the edges and frame. etc. complete as
per detailed by Architect / Consultant and directed by EIC.
Providing & Fixing Walnut anodized Aluminum Hi-Profile sections (JINDAL-
DOMAL Series), hI-perfomance Sliding/ Openable window with Required
thick glass of Saint Gobain or equielent, is used for Aluminum Hi-Profile
Section with necessary accessories and with additional shutter with Stainless
Steel Mosquito net. [In Opening Position always one of Mosquito net shouter
should be in Close Position], captive bead, extremely difficult to remove once
glazed, high performance weather stripping, internal wedge gasket, Bottom,
side and top section including necessary filling up the gaps at junctions, with
required EPDM rubber/ etc. and ISI ebco make,"Lx. Premium" Required
Finish door fixture Accessories As per Architect Concept, High security
interlocking bead, Sheet membrane flashing , 2" over jamb flashing, New
Blocking with new backer rod and sealant, channel glide with runner, slide
fold hinge when ever need of sufficient capacity, with warranty, all types of
material, labour, transportation, tools tolerance and matching required level
with Flooring etc. complete as per Architect concept and as per detailed by
Architect / consultant & Directed by EIC.
Providing and fixing standared extruded of alluminium section of size
x 38.10 x 1.95 mm @ Wt 1.094Kg / Rmt with colour anodized alluminium
frame with 5 mm thick transparent bronze colour tinted float glass with
55 colour anodized alluminium frame for ventilation with 5 mm thick frosted Smt 5.00 1,301.82
glass as details etc complete for.window
Applying two coats of putty & two coats of primer of approved brand and
manufacture on new wall surface to give an even shade including thoroughly
brushing the surface free from mortar dropping and other foreign matter
and sand papered smooth & Wall painting (two coats) with plastic emulsion
paint of approved brand and manufacture on undecorated wall surface to
56 give an even shade including throughly brushing the surface free from Smt 2156.00 119.49
mortar droppings and other foreign matter and sand papered smooth.
ARCHITECT: ARG Creation Pvt. Ltd. 7 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Applying two coats of putty & two coats of primer of approved brand and
manufacture on new wall surface to give an even shade including thoroughly
brushing the surface free from mortar dropping and other foreign matter
and sand papered smooth & Wall painting (two coats) with plastic emulsion
paint of approved brand and manufacture on undecorated Ceiling surface to
give an even shade including throughly brushing the surface free from
57 mortar droppings and other foreign matter and sand papered smooth. Smt 1431.00 122.67
Extra over item 57 for painting with plastic emulsion paint of approved
brand on ceilings and sloping roofs.
Finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly brushing
58 the surface to remove all dirt, and remains of loose powdered materials.etc Smt 1634.00 114.53
Painting two coats (excluding priming coat) on new steel and other metal
surface with synthetic enamel paint, brushing to give an even shade
including cleaning the surface of all dirt, dust and other foreign
matter.Painting two coats (excluding priming coat) on new steel and other
metal surface with synthetic enamel paint, brushing to give an even shade
including cleaning the surface of all dirt, dust and other foreign matter.
Pro. And fixing single layer water proof gypsum board 12.5 mm thick
sections using water proof board of size 1220 mm x 1830 mm x 8.0 mm
suspended by GI suspender channel of size 25 mm x 3 mm with
intermediate channel og size 18 mm x 40 mm x 0.8 mm at 1220 mm center
to center ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c
and perimeter channel A of size 20 mm x 27 mm x 30 mm x 0.5 mm at
60 edges & drops incl.paper tap sand sofit cleat, anchor fastener, scoch bolt Sqm 755.00 606.95
connecting cleat,joining compound top coat on ceiling incl.making
necy.opening for light fitting,diffuser etc. comp. as per detail drawing as
Providing and fixing M.S. grills of required pattern to wooden frames of
windows etc. with M.S. flats at required spacings and frame alround, square
61 or round bars with round headed bolts and nuts or by screws (A) Plain Grill. Kg 4784.00 114.44
Providing, fabricating and fixing STAINLESS STEEL RAILING OF AISI-304 grade
using 50mm dia Stainless Steel pipe of 16 gauge, 3 nos. 16mm dia SS pipe
of 16 gauge, round balustrade of 38mm [50mm 16G Grade 304 with glossy
finish consisting of 38 NB or nearest size vertical posts 900 Height at
maximum spacing 900c/c with suitable cups at bottom and top rail of 50 NB
or nearest size & intermediate rails of 20 NB or nearest size etc complete]
with complete assembly of SS studs to house the horizontal 16mm pipes and
top handrail, bend and coupler to be used as per architectural detail
drawings for the railing in parapet, stair etc. including fabricating, hoisting,
62 fixing in position with angle cleats, holdfast etc. in RCC or masonry in true Rmt 56.00 3,563.68
line level and plumb, including complete assembly, including matt polishing
and buffing complete, including scaffolding etc. complete as directed by
EIC.(Actual length of stair railing shall be measured at site & same shall be
paid. No wastage should be measured or paid.)
Providing and fixing in position S.S. daso by providing top 50 mm dia stain
less steel pipe rail with starting and end point vertical post of 50 mm dia
with wall/column including bending welding and fixing for staircase and
balcony as directed.(testing is required of s.s 304) for all floor.
Structural steel work ( Confirming to IS 4923-1997) riveted, bolted or
welded in builtup for all type sections, in framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer all complete as per the structural designs and directions of Engineer
in charge.Column ( 122 x 61 x 3.6mm )
ARCHITECT: ARG Creation Pvt. Ltd. 8 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and laying broken chine mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to
plain or slope and to be tempered to bring mortar creme out upto surface
65 using white cement including rounding off junctions and extending them Smt 743.00 747.29
upto 15 cm along the wall,clearing with water and oxalic acid etc. as
Water proofing-Providing and applying primer + 2 coats of Single
component, high solids, cold applied liquid polyurethane elastomer
waterproof membrane (ELASTOROOF PU– Sunanda speciality pvt coating ltd
or Equivalent) over uniform surface of slab. Apply 2 coats at dosage of
kgs per sqm to achieve the required minimum DFT of 1.5mm. It should
following properties :-
1. Total Solids % 95 ± 5%
2. Specific Gravity 1.30 ±
66 3. Elongation % ≥ 700% Smt 743.00 979.14
4. Dosage 1.2 - 1.5 kg/m2 in two coats
5. Tack Free Time 24 - 48 hrs
6. Tensile Strength N/mm² ≥
7. Low Temperature Crack Bridging No crack
8. DFT 1.2 - 1.5 mm on smooth, non- absorbent surface
9. Shore Hardness 40 ±
10. Conformance Conforms to ASTM C
Providing & Laying M250 grade concrete trimix using P21 (water reducing
concrete admixture at 100 ml per bag of cement & recon 3 s fiber at 125 gm
per bag of cement including carrying out vaccum dewatering and power
floater treatment in floors well compacted mechanically vibrated finish to
require levels making C channel 75 x 75 mm required to maintain level
67 slope and thickness of the concrete road leveling of placed concrete with Cmt 196.00 8,452.79
surface vibrator and finishing with power floater & trowel light brooming the
surface & including cutting & filling of expansion joint as directed by
Engineer in charge
Providing and laying 40 mm thick Cobble Stone, hand cut and chiseled
dressed on top of required or detailed sized and design and color in flooring
of Approved Quality with Cement colour mixed pigment grouted flooring
pavement As per Architectural Concept & Design Incl. laid on a bed of
mm thick cement mortar 1 : 6 (1 - cement : 6 - coarse sand) finishing with
including grouting the joints with epoxy, polymer & white cement &
68 matching pigments etc., complete. [a] Spacer tape 6.4 mm thick x 4 mm to 6 Smt 674.00 2,050.00
mm as per detailed groove, etc. complete as per approved pattern and
detailed drawing by Architect at all level. and as directed by E.I.C.
Providing and fixing pre-cast concrete kerb stone of gray cement based
concrete block 30cm length,30cm height and 15cm thick of M250 grade
concret as per approved design and including excavation for fixing in proper
line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc
Supplying and fixing reinforced concrete heavy duty non pressure pipes with
collars for culverts carrying heavy traffic as per IS 458-1991 specifications
including setting the pipes in C.M. 1:2 watering and laying (to level or
slopes) of class NP3 of following internal daimeters.(i) 300mm dia.
Providing and fixing Directional and Informative Signages- SS Plate, Grade
304, Brush finish, 2mm Thickness with smoothen corner edges, Acid etching
71 with duco color, SS studs 1.5' away from wall.fitting as per dirction of Smt 22.00 92,433.18
Architect and EIC
Providing and fixing 12' height, 1.5" EMBOSSED Mat / polished / colored SS
LETTERS MADE FROM 1mm thick 304 quality SS sheet cut outs on front Per
72 surface, 0.5mm thick Mat / polished / colored 304 quality Sheet for emboss word 40.00 1,616.00
ARCHITECT: ARG Creation Pvt. Ltd. 9 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
LAYING OUT LAWN – After excavating soil upto 30 cm. depth & removing
unwanted stuff, stones etc. Preparing soil for planting by supplying and
mixing 6 inch river fine site and 0.5 cmt FYM maximum 100 sqmt of lawn
area and doing termicide @ 1 fit / 100 sqmt area and planting selection
73 type / approved lawn grass at maximum 6 cm x 6 cm distance and maintain Smt. 1814.00 76.65
it upto 120 days. Maintainance include all operations i.e. watering, grass
cutting, gap filling, applying of fertizer if require etc.
Supplying, Spreading and leveling of good earth like firtile soil as directed
74 etc comp Cmt 545.00 405.81
Supplying, Spreading and leveling of good quality river Kap Filling 100 mm
75 as directed etc comp. Cmt 545.00 405.81
Supply and Planting saplings of Hedge plants like kadvi mahendi, karmda,
dyuranta, nikodeviya etc. specifies bag size is 4 inch x 6 inch, well
76 established & free from disease at site. as per the instructions Nos. 1000.00 50.86
Providing & Laying & jointing in true line level U.P.V.C. SWR type B pipe
confirming to IS 13592-1992 with one end plain & other end socket with
rubbering & Fixing conforming to ISI 14735-1999 of approved make for
drain system pipe line, pipe shall be jointed with each other with rubber
lubricant, pipe shall be fixed on wall using PVC clamps of the size 160mm
dia x 210mm length x 196mm high at every 2000mm centre to centre or
shall be concealed in wall as directed necessary fittings such as bends,
77 shoes, etc. incl. testing of pipe & joint & jointed with adhesive solvent, Rmt 50.00 831.22
cement incl. cost of all material etc. complete as per detailed, directed &
approved by the consultant / EIC. (A) 160mm dia. etc. complete as per
detailed, directed & approved by the consultant / EIC.
Providing & Laying & jointing in true line level 110mm dia U.P.V.C. SWR type
B pipe confirming to IS 13592-1992 with one end plain & other end socket
with rubbering & Fixing conforming to ISI 14735-1999 of approved make for
drain system pipe line, pipe shall be jointed with each other with rubber
lubricant, pipe shall be fixed on wall using PVC clamps of the size 160mm
dia x 210mm length x 196mm high at every 2000mm centre to centre or
78 shall be concealed in wall as directed necessary fittings such as bends, Rmt 50.00 835.15
shoes, etc. incl. testing of pipe & joint & jointed with adhesive solvent,
cement incl. cost of all material etc. complete as per detailed, directed &
approved by the consultant / EIC.
Providing laying and jointing in true line and level 75mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
ARCHITECT: ARG Creation Pvt. Ltd. 10 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing & Fixing gun metal check or no return full way wheel valve etc.
84 complete as per the instruction of EIC. (C) 25 mm. Dia Each. 8.00 420.63
Providing & Fixing gun metal check or no return full way wheel valve etc.
85 complete as per the instruction of EIC. (E) 40 mm. Dia Each. 4.50 663.43
Providing and fixing screw down bib taps of following size.(A) Brass screw
86 down bib tap polished bright. (i) 15mm dia. Each. 10.00 184.98
Providing and fixing brass screw down stop tap.(C) 25mm dia.
Providing & Fixing PVC SWR Nahni trap IS 14735 for drain- 100mm diameter
with 150 mm X 150mm S.S.jali for floor or nahni trap of the following
nominal diameter of self cleansing design with C.I screed down or hinged
88 grating including the cost of cutting & making good the walls, as per Each. 15.00 525.83
detailed, directed & approved by the EIC.
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber
and water tight C.I. cover with frame of 300mm x 300mm size (inside) with
89 standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type. Each. 5.00 1,279.40
Constructing brick masonry chamber for underground C.I. Inspection
chamber & bends with bricks having crushing strength not less than 35Kg.
Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm internal
dimensions, total weight of cover with frame to be not less than 38Kg. (Wt.
of cover 23 Kg.) & Wt. of frame 15Kg. ) (R.C.C. top slab with 1:2:4 mix (1-
cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls & bed concrete for (i)
Inside dimensions 455mmx 610mm & 450mm deep for single pipe line. etc.
complete as per detailed, directed & approved by the consultant / EIC.
Constructing brick masonry manhole with R.c.c. top slab in 1:2:4 mix (
cement : 2 coarse sand :4 grade stone aggregate 20mm size ) foundation
concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 brick bats 40 mm size )
inside plaster 15mm thick with CM 1:5 ( 1 cement : 5 Coarse sand ) finished
with a floating coat of neat cement & making channels in cement 1:2:4 mix (
1 cement : 2 coarse sand :4 stone aggregate 20mm nominal size ) finished
smooth complete including curing & testing… ( I ) inside 900mm x 1200 mm
& 1.5 m deep including R.c.c. cover with frame size 560 mm diameter ( A )
91 with 230mm thick walls of brick masonry using brick having crushing
strength not less then 35 kg/sqcm in CM 1 : 5 ( 1 cement : 5 coarse sand ),
(2) B type depth 1.50 Meter for 150mm diameter sewer.. etc. complete as
per detailed, directed & approved by the consultant / EIC.
ARCHITECT: ARG Creation Pvt. Ltd. 11 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing & Fixing white colour, Vitreous china, under / Over Counter wash
basin with single hole for pillar type with Cl or MS brackets painted white
including cutting holes, ranking bolts for Fixing & marking good the same,
including Fixing C.P. Brass waste coupling 32mm dia & Bottal trap & 15mm
dia pillar tap, Bottle Trap, as approved, capstan head C.P. screwed down high
pressure with screw shank & back nuts & rubber plugs, 15mm dia brass stop
cock (50/75mm p.v.c. Drain connection pipe, Water Connection Pipe of
required Size, & testing the same for leak proof, etc. with all material &
labours to complete this job in all respected manners, etc. complete as per
detailed & approved by the consultant & directed by EIC.
Providing and fixing wash down water closet (European type, W.C. Pan) with
integral P or S trap including jointing the trap with soil pipe in Cement
Mortar 1:1 (1 - Cement : 1 - Fine Sand) with plastic seat and cover for wash
down water closer with C.P. brass hinges, C.P. brass toilet paper holder, Jet
93 Spray, Health Fauset Heavy duty with hook with fitting, Metropole, Incl. Each. 4.00 5,965.72
Connection and rubber buffers. (A) Vitreous China., etc. complete as per
detailed & approved by the consultant & directed by EIC.
Providing & Fixing 600mm x 450mm beveled edge mirror of superior glass
mounted on 6mm thick A.C. sheet or plywood sheet & Fixing to wooden
plugs with C.P. brass screws & washers, etc. with all material & labours to
94 complete this job in all respected manners, etc. complete as per detailed & Each. 4.00 833.73
approved by the consultant & directed by EIC
Providing & Fixing pillar tap, screw down high pressure with screws, shanks
95 & back nuts. (i) 15mm dia. Each. 4.00 308.73
Providing and fixing Kitchen / Laboratary sink with C.I. or M.S. brackets,
96 painted white including cutting holes in walls and making good the same but Each. 1.00 2,280.27
excluding fittings.
Providing erecting and fixing double coated ISI water tank of required
97 capacity each with all necessary fittings and connection etc. complete on Ltr. 25000.00 3.95
Lowering of Submersible pump set complete with required nos and size of
Column pipe ( GI / HDPE pipe) erected by means of proper chain pulley block
& pipe wrenches after checking of threads of each pipe with coupling to take
98 the load of the pump set and pipe assembly filled up with water with trail Job 1.00 2,932.79
testing, wiring GEB test report.
Single phase submersible pump motor set with control panel. (c) Motor
99 rating 2 HP (17 stage) pump having capacity of 106 LPM at 40 mtr head Set 1.00 21,694.80
suitable for 32 mm dia. delivery pipe, Cat Q- II
100 Flat PVC cable size 4.0 sq.mm Mts. 150.00 85.85
101 HDPE pipe - 40 mm dia. Mts. 150.00 126.25
Providing and fixing in position U.P.V.C. cowl went to pipes. (C) 100mm dia
Providing & Fixing handicap toilet set with Wall-mounted European Closet &
wash basin & all handicap requirement with dual flush tank, seat & lead
(heavy duty) including C.I. Brackets, C.P. brass hinges, M.S. / C.I. painted
brackets, Waste Coupling, 32mm size bottle trap etc. all Internal fittings
complete with grab rails etc. rubber buffers, C.P nuts, bolts etc making holes
in walls & floors, & finishing for ready to use. The rate includes all necessary
connection charges as per product detail to the satisfaction of Architect /
103 engr. in-charge where required & the final handing over etc. complete as per Each. 1.00 53,418.90
specifications, drawings & as directed by the Engineer-in-charge. The scope
includes following items: EWC with seat cover & dual flush tank & WASH
BASIN SET: - CERA 'CRUSE SET' as approved by Architect / consultant &
Directed by EIC.
ARCHITECT: ARG Creation Pvt. Ltd. 12 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing Septic Tank of 10.00 mt x 4.00 mt x2.00 mt size for Sewerage
including excavation with any strata up to four meter depth,PCC in Bottom
Slab 1:3:6,Brick Work in cement mortar 1:5, RCC M200 Slab on Top And
bottom, required filling for Tank including making Required line for water
inlet, precast RCC M.200 Frame & cover etc.as directed by engineer in
charge. etc complete, septic tank as per detailed drawing.
Providing sock pit of 2.5 Mtr. Internal dia. and 5 mtr Depth internal clear
dimention including the cost of excavation, P.C.C. 1:4:8 and filling brickbats
with dry masonry work, Honeycomb masonary work, M:200 RCC. SLab incl.
form work including FE-500 Reinforcemnt, M.S.cover, C.I. Pipe & cowl vent,
vatas in C.M. 1:3 with finishing curing etc. complete as directed.. etc.
complete as per detailed, directed & approved by the consultant / EIC
Cleansing Site including the uprooting of rank vegetation, grass, brush
wood, trees and saplings of girth up to 30 cm measured at a height of 1 m
106 above ground level and removal of rubbish up to a distance of 50 m outside Smt 173.80 55.00
the periphery of the area cleared.
Providing and applying LIME BASED CHEMICAL WATERPROOFING TREATMENT
on the sunk area,wall area, and celling area including roughing cleaning the
surface after applying internal waterproofing 2 coats of KRISHNA CONCARE
Latex Water Resistant Bonding Agent Spread primer by using KRISHNA
CONCARE Latex in Water = 1: 4 by volume to obtain a thin layer. applying
107 coat for waterproofing on structures to prevent water infiltration and Smt 612.15 650.00
dampness. including curing at with specified period as directed etc.
complete as directed by EIC.
Cleaning of entire inside and outside of building as per given remedies and
specification from Architect / Engineer in-charge firstly to remove all kinds
of algae/fungus/dust, dirt, or loose materials contaminants liatance etc with
Dry cleaning and water jet cleaning. After cleaning the entire outside surface
and weedification treatment applying two coat of unit bio- wash
108 concentrated coating for all roots of algae, fungus, lichens, mosses and big Smt 1224.30 450.00
plants etc. complete as required by site conditions and Architect / Engineer
in-charge approval.
Opening and repairing of all types of cracks in a "V" groove manner and
grout lime mortar in crack's cavity portion on an interval of 2-3 days plus on
some equal interval put a big size of stone clipping after which the top
109 surface of crack shall be repaired with traditional lime mortar etc. complete Rmt 74.20 1,500.00
as required by site conditions and Architect / Engineer in-charge approval.
Providing & fixing at New construction and Restoration of solid stone work,
Detection, part removal and repair of all eroded solid stone work on
parapets, columns, plinth, grills, lintel etc., including part cutting, including
new stone piece to match original design and finish, in line and level,
including refilling all joints in traditional lime mortar 1:2 etc. complete as
required by site conditions and Architect / Engineer in-charge approval.
Restoration of stone / Brick and plaster surfaces, Restore all surfaces of all
eroded stone members, over and above mentioned before including
application of bond coat followed by consolidate surface and adhesion
111 promoter for subtracts etc. complete as required by site conditions and Smt 100.00 825.00
Architect / Engineer in-charge approval.
ARCHITECT: ARG Creation Pvt. Ltd. 13 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Restoring and repairing simple or ornamental plaster of front façade,
cornice, flower pattern, geometric pattern, Applying traditional lime plaster
on all surfaces, in proportion of 1:3 (lime: sand) with traditional method like
sieving, slaking, crushing and knocking etc and also use of only natural
additives in lime mortar, using approved quality lime cured as per standards,
112 to match with existing quality of mortar and plaster, applied and cured as Smt 100.00 2,250.00
per standards as required by site conditions and Architect / Engineer in-
charge approval.
Applying traditional araise plaster (rough and smooth texture both)on thappi
lime plaster on all surfaces, with traditional method like sieving, slaking,
crushing and knocking etc and also use of only natural additives in lime
mortar, using approved quality lime cured as per standards, to match with
existing quality of mortar and plaster, applied and cured as per standards as
required by site conditions and Architect / Engineer in-charge approval.
Dampness treatment, Fixing & grouting 10-12mm dia nozzles in to the
drilled hole and place the nozzle in such a way with distance of 12" inch
from each other, and Seal the nozzle with suitable material and allow it to set
at least for the day before grouting, Grouting should be carried out by the
means of hand pump sufficient enough to create pressure of approx..2kg to
4kg must, inject silicon (Liquid and powder form both) injection grout
114 through pressure grouting machine, with the mixing proportion of 1:10 ( Rmt 112.50 1,450.00
one liter material & ten liter of water) etc. complete as required by site
conditions and Architect / Engineer in-charge approval.
Removing old detoriated plaster,wll tiles,paints,cement joints and unwanted
parts from entire building's inside-outside surface and staking away debris
115 from site etc complete as required by site condition and architect/engeineer Smt 412.50 85.00
in-charge approval
As per architect instruction and remedies applying strengthning stages for
the weak part of the building like walls,slab, and each and every weak parts
116 etc. complete as required by site conditions and Architect / Engineer in- Smt 100.00 350.00
charge approval.
providing and applying 6 stage treatment of strengthning and face lifting for
out side entire wall include 1St Stage cleaning the surface with brush for and
in 2 nd stage cleaning the surface with water's noramal pressure. After that
in 3 rd stage apply a sealer coat which seal porosity and crevices and give
excellent adhesion of over coated treatment along with consolidation of the
substract and in 4 th stage apply a sleekcoat for Avoding further erosion
abrasion,and to level the substract , and for 5 th stage again apply the sealer
coat to strengthen the base then after 6 th stage apply a two coats of
117 duraflex in red shed.this coating is U.V Stable water tight, weather durable,
dust repellant, with excellent architectural appearance and prevent growth of
fungus, algae, & moss etc. complete as required by site conditions and
Architect / Engineer in-charge approval.
Protective coating of all interior and exterior surfaces, including those
restored and cleaned, for protection against all weather conditions, with
prior approval of architect / engineer in-charge, inclusive of 1 years
118 performance guarantee etc. complete as required by site conditions and Smt 1237.50 550.00
Architect / Engineer in-charge approval.
Applying paint remover or grinding on painting surface and removing all
119 kind of paints on wooden,steel,and stone surface Smt 50.00 350.00
ARCHITECT: ARG Creation Pvt. Ltd. 14 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing, supplying, fixing, fabricating, erecting, aligning the structural
steel like pivot, tubular 'T', 'I" section, angle, plate, beam, channel section,
Bar, hollow box or Z purloins, Round or Square Pipes, of TATA or approved
make, for built up purloins, roof trusses, columns, side runners, tie beams,
sag rods, base plates gusset plates, cap plates, bearing bracing, gantry
girders, rails, require support, pipes, including all welded or bolted steel
structures of various types with approved I.S.I. mark electrodes, bolts,
anchor bolts including cost of thread, Anchor plate cleats etc. in RCC or
masonry work, including cutting, bending, welding, fixing, supplying,
Fabricating Decorative fevisted section or any structured member required to
complete the job for Bridge, Trusses, Canopy, doors, Frame, Railing,
120 Entrance gate, pergola, Decorative hanging light, New window, parking shed Kg 300.00 150.00
or space frame or any other required specified area as shown on drawing
and detailed specification or as per design incl. three coats of approved
brand primer and two coats of paints, necessary scaffolding, tools tolerance
etc. complete as directed by Engineer-In-Charge. (payment will be made for
weight of metal used in the work)
Restore and conservation of old wall painting near as per artist instruction
Supply, Installation, Loading/Unloading of following Items: VRF Outdoor
122 Units :- 14 HP Outdoor Unit (Top Throw) Nos. 1.00 252,205.00
Supply, Installation, Loading/Unloading of following Items: VRF Outdoor
123 Units :- 16 HP Outdoor Unit (Top Throw) Nos. 4.00 269,148.00
VRF Indoor Units :- 4 Way Cassette Type(Regular) (With Drain Pump) - 1.5 Tr
VRF Indoor Units :- 4 Way Cassette Type(Regular) (With Drain Pump) - 2.5 Tr
VRF Indoor Units : 4 Way Cassette Type(Regular) (With Drain Pump) - 3 Tr
VRF Indoor Units : 4 Way Cassette Type(Regular) (With Drain Pump) - 4 Tr
128 VRF Accessories :- Pannel (4 Way Cassette) Nos. 21.00 9,992.00
129 VRF Accessories :- Central Controller (Touch Screen) Nos. 1.00 63,300.00
130 VRF Accessories :- Wireless Remote Nos. 21.00 1,743.00
131 VRF Accessories :- Twinning Kit (2 ODU) Nos. 1.00 7,273.00
132 VRF Accessories :- Twinning Kit (3 ODU) Nos. 1.00 8,548.00
133 VRF Accessories :- Separation Tubes Nos. 18.00 3,500.00
Supply & Installation of Haevy guage VRF Copper piping: Seamless heavy
gauge VRF Copper piping of following size duly insulated with 13 mm/
19mm thk. Nitrile Rubber Insulation. Piping inside building to be supported
134 with Sprinkler type U-Clamps embeded with black rupper. Piping in exposed RMT 330.00 3,300.00
area to be taken in GI Cable Tray with GI Cover for Protection.
Supply & Installation of Haevy guage VRF Copper piping: Cable Tray With GI
135 Cover for Exposed piping (200mm*150mm) RMT 20.00 1,600.00
Supply, installation, testing and commissioning of control cum transmission
wiring of 2 core x 1.5 sqmm copper sealded cable in suitable PVC
136 conduits between indoor and out door unit & outdoor units to central RMT 719.00 350.00
remotes controllers.
PVC Drain piping for the units with 6/9 mm thick nitrile rubber insulation
137 clamped as per specifications. RMT 147.00 210.00
138 MS Stand for Top Throw ODU (Epoxy Coated, Black Painted) Nos. 5.00 6,750.00
139 Lifting/Shifting & Placement of Heavy Equipments. Nos. 7.00 3,500.00
Testing & Commissioning charges along with topping-up of refrigerant as
140 per specifications. Lot 1.00 140,400.00
141 Brick wall Chiselling (Jari) Work RFT 50.00 120.00
142 Core Cut (Upto 4 In) Nos 15.00 1,500.00
143 DX-Split unit :1.9 Tr 3 Star Non Inverter New Nos 14.00 46,603.00
ARCHITECT: ARG Creation Pvt. Ltd. 15 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Supply & Installation of Haevy guage NON-VRF Copper piping: Seamless
heavy gauge Copper piping of ollowing size duly insulated with 6 mm thk.
Nitrile Rubber Insulation. Piping inside building to be upported with U-
144 Clamps. Piping in exposed area to be taken in GI Cable Tray with GI Cover RFT 672.00 450.00
for Protection. Upto 2 TR DX Units
Supply,installation,testing and commissioning of control cum transmission
145 wiring of 4 core x 1.5 sqmm copper cable in suitable PVC conduits between RFT 739.00 85.00
indoor and out door unit.
PVC Drain piping for the units with 6 mm thick nitrile rubber insulation
146 clamped as per specifications. RFT 364.00 75.00
147 L-Bracket / Base Stand for ODU (Upto 1.5 Tr Units) Nos. 14.00 1,400.00
148 Nitrogen Flushing & Pressure testing Nos. 14.00 1,000.00
Point wiring in Copper (Modular)--Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multistrand copper wires, in following type of pipe
to be erected concealed in/ on surface on wall/ceiling complete with 6A
Modular type switch / bell push & accessories and earth continuity of
following type, erected on PVC / Metallic box, single mounting base frame
covered with textured/metallic front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.--(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete Cat. III
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of
sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multistrand copper wires, in following type of pipe to be erected concealed
in / flushed on wall/ceiling, complete with earth continuity and necessary
connection with primary light with accessories erected on Metal / PVC box
covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector
as directed.--Note:- Maximum up to 6 mtrs length, excess will be
considered as Mains for Secondary Point.--(f) with medium class Rigid PVC
pipe and accessories erected concealed in wall/ceiling complete Cat. III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper
wires, in following type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and hum free EME four or
more step type electronic fan regulator with separately mounted and
accessories with earth continuity of following type erected on PVC / Metallic
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed--(f) with medium class Rigid PVC
pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per pipe
152 erected with following type of accessories.--[I] For 6A Plug and 6 a switch Pt. 60.00 553.00
with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board--(f)
with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete. Cat. III
ARCHITECT: ARG Creation Pvt. Ltd. 16 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per pipe
153 erected with following type of accessories.--[II] For 16A Plug and 16 amp Pt. 20.00 505.00
switch with 2-2.5 sq.mm Cu. Wire from mcb db board.--(f) with medium
class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete. CAT III
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic box, single mounting base frame covered with
textured / metallic front plate modules erected on / in wall / ceiling with
following type accessories.--Single mounting base-frame & Textured /
Metallic front plates. Cat-III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of pipe to be erected
concealed in / flushed on wall/ceiling ,complete with 6A Modular type
switches and following type of accessories erected on PVC / Metallic box,
single mounting base frame covered with textured / metallic front plate
155 modules erected on / in wall / ceiling as per pipe erected. with necessary Pt. 15.00 653.00
batten/angle holder or ceiling rose or H.D.Connector as directed.--(f) with
medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete. Cat-III
Providing following type of Modular Type Accessories mounted with pvc /
metallic box, single mounting base frame covered with textured / metallic
front plate , modules erected with necessary connection. As desired by
Engineer In charge
(7) Blank Plate Single Cat-III
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as directed--b) 25 mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
158 coupling, PVC bushes, Check-nuts etc. complete of following sizes. (2) 25 Mtr. 150.00 21.00
Mains & Wires--Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor
159 FRLS PVC insulated stranded wire of green colour for earth continuity of Mtr. 450.00 62.00
following size (a) with medium class Rigid PVC pipe and accessories--(a)
wire 1.5 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in /flushed
on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size (general
(a) with medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm (FRLS)
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
161 green colour for earth continuity of following size (FRLS) (a) with medium Mtr. 500.00 111.00
class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe of following size of cables --(G) 3 1/2 core
Sq. mm ( 70 Sq. mm 1/2 core)
ARCHITECT: ARG Creation Pvt. Ltd. 17 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps
163 or in existing trench / pipe of following size of cables --(F) 3 1/2 core 120 Mtr. 75.00 535.00
Sq. mm (70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or
164 in existing trench / pipe at road crossing or floor of following size of Mtr. 225.00 285.00
cable. (B) 3 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand /
Solid Copper conductor for 1.1 KV. to be laid on wall with necessary
165 clamps or in existing trench / pipe at road crossing or floor of following Ea. 50.00 361.00
size of cables. (B) 4 core 4 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
166 insulating tape etc for following size of cables. --(A) 2 to 4 core 2.5 / 4 Sq. Ea. 52.00 33.00
Providing and, fixing heavy duty flange type brass double compression type
cable gland with rubber ring for PVC insulated armoured cable complete with
167 out going tails, insulating tape etc for following size of cables. (E) 3 core 120 Ea. 8.00 139.00
Providing and, fixing heavy duty flange type brass double compression type
cable gland with rubber ring for PVC insulated armoured cable complete with
168 out going tails, insulating tape etc for following size of cables. (F) 3 core 150 Ea. 4.00 189.00
Solder less crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. (A) 1.5/ 2.5/4/6 Sq.mm
Solder less crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner.(E) 70 Sq.mm.
Solder less crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner.(G) 120 Sq.mm.
Solder less crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner.(H) 150 Sq.mm.
Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V
A.C. system and having breaking capacity 10 KA to be erected in existing
173 box. confirming to IS 8828/1996 with ISI Mark(QTY FOR MCB OF DB AND Ea. 51.00 111.00
MCB OF PANEL) Cat-III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
174 having following capacity. Ea. 5.00 662.00
(B) 40 Amp. Cat III
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of MCB
175 to be used) suitable for-- Ea. 9.00 2,885.00
(B) three phase incoming and single phase horizontal type outgoing Per
phase isolation type (PPI)--(b) sheet steel double door (IP-43) (ii) 6 way
ARCHITECT: ARG Creation Pvt. Ltd. 18 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Approved make ELCBs / RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable
for operation on single phase 240 V. having characteristic of quick action &
tripping with all advance feature & do not incorporate any electronic
component.for following Max. rating erected as directed
(i) 25 Amps. DP Cat-III
Providing and erecting MAIN LT PANEL
• Incoming : 250 amps FP MCCB (35 KA) with following accessories: 1 Set
ACB ON / OFF / TRIP indicating lights with control MCB’s. Under voltage
release 3 Nos. of 0-1000/ 5 amps CTR digital VAF with 3 nos 250/ 5 amps,
15 VA Class 0.5 CT’s. Digital type 0-500 Volt digital voltmeter with inbuilt
selector switch & shall be protected by 2 amp TP MCB’s--Bus Bars 300amps
FP aluminium bus bars with coloured heat shrinkable insulated sleeve.
177 • Outgoing All the outgoing should be provided with RYB - On - Off - Trip Ea. 1.00 250,000.00
I/L . (For MCCB only)
- 200A FP MCCB TH BASED :-1 No - 200 A FP ATS - 1 No
- - 40A FP MCB: 9 Nos.
- 20A DP MCB: 1 Nos.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
178 (fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have Ea. 100.00 1,777.00
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(B) LED Panel Light with provision for Plane front frame with translucent
cover fixed to housing complete.IP20 (vi) 36 watts, 24" x 24", Surge- 2KV
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
179 (fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have Ea. 25.00 607.00
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(B) LED Panel Light with provision for Plane front frame with translucent
cover fixed to housing complete.IP20 ((iii) 12-15 watts, 6" x 6", Surge-2 KV
ARCHITECT: ARG Creation Pvt. Ltd. 19 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
180 LED driver efficiency > 85 % Ea. 150.00 1,354.00
(fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
((F) Spot Light 425 Lumens, Surge-2KV (ii) 8 to 11 Watts cat-iii
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name --
160V to 270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %--(
181 fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have Ea. 4.00 309.00
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(H) Mirror Light 9 Watts, wall mounted minimum 1 feet long
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name --
160V to 270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %--(
fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have
182 shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(D) LED Strip Light (i) Minimum 4.8W-120 LED per meter (2 wire, IP-65) with
non integral suitable Driver complete Cat-lll
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium blades with , canopy &
183 cm. down rod erected with earthing.(Make shall be approved by Engineer in EA. 20.00 2,275.00
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to
the RCC bars up to 50mm length each side and pierced through a 16 Gauge
184 M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with EA. 20.00 125.00
necessary finishing.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan
Supplying & erecting approved make low noise decorative exhaust fan having
square frame ABS body with inbuilt lowers & square frame. 200mm with
1350RPM. Cat-II
ARCHITECT: ARG Creation Pvt. Ltd. 20 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Supplying and erecting approved make Octagonal pole made from HR sheet
steel. The pole should be made as per IS. and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be erected With Suitable
foundation (Included) as per details given by manufacturer considering site
requirement.(C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm
thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole weight 46 kg
Supplying and erecting LED street light / Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.(
188 fittings required LM-79 & LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.) (iii) Above 60 to
Providing & erecting approved make street light / wall mounting junction
box compression moulded from SMC (thermoset plastic) vertical sliding
cover having locking with square head stud loop in / loop out in built
189 terminal suitable for four core cable, waterproof of I.P. 54 protected with EA. 40.00 353.00
clamp or bolt nut & earth bolt of following size. (A) 200mm x 127mm x
Supply & fixing decorative Hanging light with glass having cylindrical or
square shape having length not less than 10" & width not less 3.5" with
holder, lead wire as per required length but not more than 1mm & base plate
for fixing the fitting with ceiling.[a] suitable for led lamp Cat-III
Supplying and erecting LED Spike Outdoor fittings with LEDs of wattage 7W.
Providing and erecting required size HOT deep Galvanised iron strip for
192 earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using Kg. 10.00 77.00
Providing and erecting HOT deep Galvanised iron strip wire 8 to
193 SWG.Using for DB earthing wire 8 to 16 SWG. Kg. 20.00 77.00
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia
of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising, connection terminal dia of 14 mm
with constant ohmic value surrounded by highly conductive compound with
high charge dissipation suitable for panel earthing.[A] For electrical
installation up to 440 V
194 [C] For Electrical Installation covering Transformer Neutrals, Lightning
arrester Earthing, A.C.Plant & Sensitive Computer System (like Automation,
SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3 mtrs Back
filling Compound: 2 nos Bags of 25 Kg.
4/5/6 Passengers, Ground plus 1 upper floor with Rated Speed of
195 m/sec, (B) With General Specification attached herewith. Cat.III Ea. 1.00 968,452.00
ARCHITECT: ARG Creation Pvt. Ltd. 21 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Supplying and erecting, commissioning and testing of Diesel Generating set
confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase,
415 volts, 50 cycles A.C. supply comprising of a totally enclosed air/water
cooled diesel engine with multi-cylinders developing suitable BHP not less
than following capacity at 1500 RPM with 10% overload for one hour in
hours with standard accessories like fly wheel, lubricating oil cooler, "A"
class governor, heavy duty fuel wheel and lubricating oil filter, oil bath air
filler, lubricating oil pressure gauge, end exhaust manifold, standard set of
tools with adjustable spanners, screw drivers, cylinder head to cover, joint
cylinder head to exhaust, element lube oil filter, 12 / 24 volts electric
starting equipment complete with standard heavy duty battery, dynamo, cut-
outs, ammeter, necessary wiring, pressure gauge, starter etc and heavy duty
Residential type exhaust silencer and vertical hot air duct both logged with
asbestos rope, save oil trays, exhaust piping of required length, standard
wall/floor mounted fuel with level indicator and piping and drip proof
alternator, self excited, self regulated, screen protected, with excitation
system, capable of delivering the rated system output at 415 volts, 3 phase,
0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722-
196 with voltage regulation +/- 5% of rated voltage from no load to full load. set 1.00 1,382,776.00
Both the engine and alternator fitted on a common fabricated steel base
plate with antivibration mounting engine and alternator both connected to
each other by flexible flange coupling and with floor/wall mounted control
panel box comprising of voltmeter ammeter, selector switches, ACB /
MCCB / MCB of adequate capacity, indicator lamps duly wired with HRC
fuses. The alternator & control panel shall be connected with provided
suitable capacity armoured cable and complete with Acoustic enclosure
(canopy) made out of 16 SWG CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick conforming to IS:8183 / PU Foam of
40 Density - at least 40 mm. The resin bonded rockwool covered from inside
the canopy by perforated sheet with 3/4 mm holes, sound level not more
than 75 dB at a distance of 1 mtr, as per PVCT norms. Erection,
commissioning and satisfactory testing as per requirement with first filling of
fuel, oil, etc. with guarantee / Warrantee of complete system for Two years.
& with obtaining all necessary certificate from Electrical Inspector. The
Capacity and Ratings of DG sets are as below.(O) Continuous rating of
KVA ,BHP not less than 197 BHP
Providing & erecting approved make AMF control panel suitable for following
size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of
scope as detailed below:
1) Power module: A pair of electromechanically interlocked contactors (for
mains & generator) Overload relay for generator contactor Neutral
contactor for mains and generator Power socket for connections.
2) Control and metering module: Line voltage monitor. Generator voltage
monitor Ammeter 3 items attempt start facility. Air circuit
breakers/MCB/MCCB of suitable rating for auto/manual operation.
Auto/manual switch. Emergency stop push buttons. Manual start push
button. frequency meter. Engine hour meter. Two earthing studs.3)
197 Protection module: The engine shutdown in the unlikely event of Low lube oil Ea. 1.00 220,509.00
pressure High cylinder head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start . Emergency stop battery
The AMF Panel of following capacity (D) AMF Control Panel for 200 KVA/250
KVA3 phase DG Set
ARCHITECT: ARG Creation Pvt. Ltd. 22 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing & Erecting full SS Body (SS 304) Split type water cooler having
storage capacity 160 to 175 Ltr.(Tank SS 304) & Cooling capacity 150 ltr. Per
hour @ an ambient temp of 350 C.The outlet temp. of the water should drop
by 150C within a hour,The water cooler should be comprising of hermetically
sealed Reciprocating compressor with R134A, fan motor, Copper
Condensing unit with company fabricated Outdoor Unit water tank
surrounded by evaporating coil, thermostats, relay etc.complete with
necessary copper tube & Insulation, M.S Chanel Stand with Painting for water
tank & M.S. Powder Coated Stand for Outdoor unit with Installation. With
DPELCB and 4 Way DB Box with accessory Three core Cord for connection.
Liaisoning work for additional load for requirement, electrical power
199 connection charges and inspector approval for power(to be paid to concern - 1.00 25,000.00
electrical power supplier company)
PUMP Supplying, installation, testing and commissioning of electric driven
Main Fire Pump suitable for automatic operation and consisting of following,
complete in all respects, as required : (a) Horizontal type, multistage,
centrifugal, split casing pump of cast iron body & bronze impeller with
stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable
HP Squirrel cage induction motor, TEFC, synchronous speed
RPM, suitable for operation on 415 volts,
3 phase 50 Hz, AC supply with IP 55 protection for enclosure,
200 horizontal foot mounted type with Class-'F' insulation, conforming to IS-
325. (c) M.S. fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required. (d) Suitable cement concrete
foundation duly plastered with anti vibration pads. 1.1 2850 lpm at 88 m
Supplying, installation, testing and commissioning of electric driven
pressurisation pump suitable for automatic operation and consisting of
following, complete in all respects, as required : (Jockey Pump) Horizontal
type, multistage, centrifugal pump of cast iron body and bronze impeller
with stainless steel shaft, mechanical seal conforming to IS :
Suitable HP squirrel cage induction motor TEFC type suitable for operation
on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for
enclosure, horizontal foot mounted type with Class-'F' insulation,
201 conforming to IS : 325. M.S. fabricated Common base plate, coupling,
coupling guard, foundation bolts etc. as required. Suitable cement
concrete foundation duly plastered and with anti vibration pads. 3.1
lpm at 88 m Head.
Supplying, installation, testing and commissioning of diesel engine
driven main fire pump suitable for automatic operation and
consisting of following, complete in all respects, as required : (Diesel
Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron
body and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520. Suitable HP, 1500 RPM water cooled with
radiator, diesel engine conforming to relevant IS standard complete with
auto starting mechanism, 12 /24 volts electric starting equipment, diesel
tank, exhaust pipe extended upto 10 m outside pump house duly
insulated with 50 mm thick glass wool with 1.0 mm thick
aluminium sheet cladding, residential silencer, instruments and
protection as per standard specification, stop solenoid for auto stop
in the event of fault with audio indications, painted with post office
red colour etc. as required. M.S fabricated, common base plate,
coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration
2.7 1620 lpm at 88 m Head
ARCHITECT: ARG Creation Pvt. Ltd. 23 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Fabrication, supply, Installation testing & commissioning of Electrical control
panel of cubical construction, floor mounted type, fabricated out of 2mm
thick CRCA sheet, compartmentalised with hinged lockable doors, dust
and vermin proof, powder coated of approved shade after 7 tank
treatment process, cable alley, interconnection with suitable size copper
conductor cable/solid copper strip, having switchgears and accessories,
mountings and internal wiring, earth terminals, numbering etc. complete
in all respect, suitable for main fire pump, pressurisation pump & diesel
pump set complete as per CPWD specification with following in coming and
outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac supply
with enclosure protection class IP 42 as required : 5.1 INCOMING - 400A,
203 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with No. 1.00 318,497.51
selector switch Digital Ammeter (0-400 A) with selector switch & CTs
etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating
lamps Set of Copper Bus Bar 300A. OUTGOING (Note : All outgoing
feeders for pumps should have digital Ammeter with selector switches and
LED type ON, OFF, trip indicating lamps)
204 Supply of 12 V Battery, Coolant, Engine Oil and Diesel Tank. Set 1.00 29,957.63
Supplying and fixing of Air Vessel made of 250mm dia., 8mm thick MS
sheet, 1200mm in height with air release valve on top and flanged
connection to riser, drain arrangement with 25mm dia. gun metal wheel
205 valve with required accessories, pressure guage and painting with No. 1.00 15,615.63
synthetic enamel paint of approved shade as required.
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification. 200mm dia.
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification.150 mm dia.
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification.100 mm dia.
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification. 80 mm dia.
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification. 50 mm dia.
ARCHITECT: ARG Creation Pvt. Ltd. 24 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification. 40 mm dia.
Supply, erection, testing and commissioning of heavy duty G.I. C Class
pipe line as per relevant IS along with fitting like sockets, bend,
elbows, tees, plugs, nipple, flanges, reducer etc. for pump room &
coat yellowxide, 2 coat PO red colour with painting of one coat of primer
and 2 or more coats of synthetic enamel paint of approved make /
shade complete as per specification. 25 mm dia.
Supplying, fixing, testing and commissioning of double flanged sluice
valve of rating PN 1.6 with non rising spindle, bronze / gun metal
seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming
to IS 780 of following sizes as required. 100mm
Supplying, fixing, testing and commissioning of double flanged sluice
valve of rating PN 1.6 with non rising spindle, bronze / gun metal
seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming
to IS 780 of following sizes as required. 80 mm dia.
Supplying, fixing, testing and commissioning of double flanged sluice
valve of rating PN 1.6 with non rising spindle, bronze / gun metal
seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming
to IS 780 of following sizes as required 150 mm dia.
Supplying, fixing, testing and commissioning of butterfly valve of rating
PN 1.6 with bronze / gun metal seat duly ISI marked complete with nuts,
216 bolts, washers, gaskets and conforming to IS 13095 of following sizes : No. 1.00 7,669.15
Supplying, fixing, testing and commissioning of butterfly valve of rating
PN 1.6 with bronze / gun metal seat duly ISI marked complete with nuts,
217 bolts, washers, gaskets and conforming to IS 13095 of following sizes : No. 1.00 5,706.50
Supplying, fixing, testing and commissioning of butterfly valve of rating
PN 1.6 with bronze / gun metal seat duly ISI marked complete with nuts,
218 bolts, washers, gaskets and conforming to IS 13095 of following sizes : No. 2.00 4,264.25
Providing, installation, testing and commissioning of non-return valve of
following sizes confirming to IS : 5312 complete with rubber gasket, G.I.
219 bolts, nuts, washers etc. as required : 150 mm dia. No. 1.00 15,223.61
Providing, installation, testing and commissioning of non-return valve of
following sizes confirming to IS : 5312 complete with rubber gasket, G.I.
220 bolts, nuts, washers etc. as required : 100 mm dia. No. 2.00 9,458.05
Providing, installation, testing and commissioning of non-return valve of
following sizes confirming to IS : 5312 complete with rubber gasket, G.I.
221 bolts, nuts, washers etc. as required : 80 mm dia. No. 2.00 6,582.98
Supply, Installation, Testing and Commissioning of Gun Metal Air
222 Release Valve with necessary fittings. Size: 25 mm dia. No. 6.00 1,069.91
Supply, Installation, Testing and Commissioning of 100 mm dia.
Pressure Gauge (for all pipes) of range 0 - 15 Kg/cm² conforming to IS -
3624 having bourdon tube of stainless steel 310 in cast aluminium,
stove enameled, black, weather proof case with outer, screwed
223 aluminium bezel and complete with necessary U-type stainless steel No. 2.00 1,198.30
siphon tube and cock including providing suitably painted angle iron
support to the tube etc. as per required.
ARCHITECT: ARG Creation Pvt. Ltd. 25 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
Providing and fixing of pressure switch in M.S. pipe line including
224 connection etc. as required. No. 2.00 1,323.27
Pump house Cabling : Providing, fixing, testing & commissioning of
225 Sq.mm. 3 Core Alluminium Armoured Cable of required size from Panel to Rmt 350.00 333.82
Providing, installation, testing & commissioning of Y Type Strainer
226 fabricated out of 1.6mm thick stainless steel, grade 304, sheet with 3 mm No. 3.00 9,538.51
dia. holes with stainless steel flange. 150mm
Supplying and fixing Single headed internal Fire Hydrant Valve with
instantaneous stainless steel coupling of 63mm dia. with cast iron wheel
227 ISI marked conforming to IS:5290 (Type-A) with blank cap and chain No. 4.00 5,254.57
Supplying and fixing of 63 mm dia. Gun metal short branch pipe with 20 mm
nominal internal diameter size nozzle conforming to IS 903, suitable for
228 instantaneous connection to inter connect hose pipe coupling as No. 4.00 2,067.93
required. Gun metal.
Supplying and fixing of 63 mm dia., 15 m long RRL hose pipe with 63 mm
dia. male and female coupling duly bound with G.I. wire, rivets etc.
229 conforming to IS 636 (Type-A) as required. Gun metal. No. 4.00 4,452.55
Supplying, Installation, Testing and Commissioning of Weather proof
Standard Fire Hose Cabinet wall mounting type (750 mm x 600 mm x
250 mm deep) having single or double opening with necessary locking
arrangement by allan key suitable for housing 2 nos. hose pipe, 1 no. branch
pipe & nozzle spanner.
Supplying and fixing of Fire brigade connection of cast iron body with
gun metal male instantaneous inlet couplings complete with cap and
231 chain as required for suitable dia. M.S. pipe connection conforming to Set 1.00 11,960.79
IS:904 as required : 4 way 150mm.
Supplying and fixing of Fire brigade connection of cast iron body with
gun metal male instantaneous inlet couplings complete with cap and
chain as required for suitable dia. M.S. pipe connection conforming to
IS:904 as required : 4 way 100mm dia.
Supply and fixing First Aid Hose Reel with M.S. construction spray painted
with P.O. red, conforming to IS:884 complete with the following as
required. 20mm nominal internal dia. water hose thermoplastic
(textile reinforced) type-2 as per IS:12585, 20mm nominal internal dia.
233 gun metal globe valve and nozzle, drum and brackets for fixing the No. 4.00 7,425.21
equipment on the wall. Connection from riser with 25mm dia. stop gun
metal valve & MS pipe and socket. 30 mtr.
FIRE DETECTION SYSTEMS :- Supply, installation and testing of
Addressable Powered loop Manual Call point with built-in Fault isolator,
234 housing & glass - red. Item as per drawing and specification, as No. 6.00 3,838.86
approved by Electrical Engineer in charge.
FIRE DETECTION SYSTEMS :- Supply, installation and testing of
Addressable Bus supplied Power Loop Sounder with built-in flasher,
8 Different Selectable Tones. Shall have a 'soft start' feature controlled
235 by the fire alarm panel. Item as per drawing and specification, as No. 6.00 4,040.00
approved by Electrical Engineer in charge.
FIRE DETECTION SYSTEMS :- Supply, installation, testing and
commissioning of Four Loop Addressable Intelligent Main Fire Alarm
control panel with operating front panel with network card, Keypad
300 characters & Multi lines alphanumeric display, 10,000 events memory,
On board Printer interface for external printer, battery backup. Item as
per drawing and specification, as approved by Electrical Engineer in charge.
Supplying and laying of 2 x 1.5 sq.mm fire alarm armoured cable
/ 1000 V rated with annealed copper conductor having XLPE insulation,
237 steel wire armouring & FRLS outer sheath complete as required. Rmt 1500.00 148.08
ARCHITECT: ARG Creation Pvt. Ltd. 26 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
FIRE DETECTION SYSTEMS :- Supply, installation, testing and
commissioning of Below False Ceiling Addressable ideal optical smoke
detector for detecting visible smoke particles with mounting base. Item as
per drawing and specification, as approved by Electrical Engineer in
Providing, fixing, testing & commissioning of 15mm dia. quartxoid bulb
239 type sprinklers of rating 68 degree centigrade with required accessories No. 70.00 446.79
: Pendent sprinkler.
Providing & fixing photo luminescent Signage's as per IS standard in Block /
Small Letters on rigid sheet with necessary wall or Ceiling fittings as
240 specified Sizes : For Fire Extinguisher, Exit, Do not to do etc. No. 60.00 226.83
Supply, installation, testing and commissioning of ABC type 6 kg.
241 confirm to IS:15683, with ISI marked / TAC approved fitted with No. 8.00 1,369.49
required accessories including wall suspension brackets.
FIRE EXTINGUISHER
Supply, installation, testing and commissioning of Carbon Dioxide (CO2)
type Fire Extinguisher of 4.5 kg confirm to IS:15683, with ISI marked / TAC
approved fitted with required accessories including wall suspension
Supply, installation, testing and commissioning of Modular ABC type 5 kg.
confirm to IS:15683, with ISI marked / TAC approved fitted with
243 required accessories including wall suspension brackets. No. 4.00 1,369.49
Supply, installation, testing and commissioning of Stainless Steel Ball
244 Valve. (a) 25mm dia. No. 8.00 1,155.51
Supplying, Installing, Testing & Commissioning of M.S. structural steel
245 support. Kg 350.00 81.32
Supply, Installing, Testing and Commissioning of C.I. heavy duty
foot valve with flanges, nut bolts, gaskets etc. with necessary complete
246 accessories. 150 mm dia. No. 1.00 14,122.88
Supply, Installing, Testing and Commissioning of C.I. heavy duty foot
247 valve with flanges, nut bolts, gaskets etc. with necessary complete No. 2.00 10,472.33
accessories. 100 mm dia.
Total Amount Rs. =
Total Amount Rs. =
Rupees Seven Crore Fourteen lakh Fourty Eight thousand Five hundred Ninety One and zero paisa.
I/We am/are willing to carry out the work @............ % above/below percent ( should be written in
figures & Words) of the estimated rates mentoined above . Amount of my/our tender work out as
Estimated amount put to tender Estimated amount put to tender
Deduct:……………………...….% below Add……………………..……..% above
ARCHITECT: ARG Creation Pvt. Ltd. 27 of
Sr. No. Description of Item Unit Quantity Total Amount
Sr. No. Description of Item Unit Quantity Total Amount
Rate In FIghure
IN words IN words
(Please strike out whichever is not applicable.)
The Contractor shall exhibit a board with detailed specification and details of work as directed by
1 the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where
there is a change as per actual mix design the cost of difference of cement consumption have been
deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Signature of Contractor with Seal Signature of Contracting Authority with Seal
ARCHITECT: ARG Creation Pvt. Ltd. 28 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2. Schedule B.pdf
3.1 Specification Index.pdf
3.2 Detailed Specification.pdf
3.3 Precast Wall_ installation technic r1.pdf
3.4 CROWN.pdf
3.5 DURAFLEX COOL.pdf
3.6 HYDRACRETE_SBR.pdf
3.7 SLEEK_COAT.pdf
3.8 Detailed Specification Electrical.pdf
3.9 General Specification For HVAC Landscaping Firefighting.pdf
5.0 General Civil Specification.pdf
5.1_ADDITIONAL_CPWD_SPECIFICATION_VOLUME_1_C1.pdf
5.2 ADDITIONAL CPWD SPECIFICATION VOLUME 2.1.pdf
5.4 R and B Specifications Booklet Electrical.pdf
6.1 LIST OF APPROVED MAKE LIST CIVIL.pdf
6.2 LIST OF APPROVED MAKE PLUMBING.pdf
6.3 LIST OF APPROVED MAKE ELECTRICAL.pdf
ELEVATIONS.pdf
FIRST FLOOR PLAN.pdf
GROUND FLOOR PLAN.pdf
SECTIONS -1 .pdf
SECTIONS.pdf
SITE PLAN.pdf
TERRACE FLOOR PLAN.pdf
1.1.0 SBD Jhalawad Heritage Museum.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .