| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹34.5 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹35.9 L+₹1.4 L (3.97%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹35.9 L+₹1.4 L (3.97%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹43.1 L+₹8.6 L (24.8%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹43.1 L+₹8.6 L (24.8%) | L3 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Esha Engineers L2 | Raman Electric Trading Co L1 | R D Bansal L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing as in replacement of non directional outgiong and E/Frelay with RS485 common port and 1A/5A universal CT inputs event record & DR with numerical relay for VCB tripping system (3 OC + 01 earth fault and high set instantaneous protection in single unit ) suitable for operation on 24V to 110V DC all as per existing make & model all as specified and directed. (Note : existing relays are IDMT type electromagnetic type)
Notes (The quoted rates are inclusive of the following) :-
(i) Dismantling of existing old/defective relays and mechanical modification of panel cutout (if required).
(ii) Control wiring, Ferruling, and Luting of secondary connections as per new wiring.
(iii) Secondary Injection Testing, Pickup / Timing tests, and Relay Parameterization after Relay Co-ordination Test Report
(iv) Integration of Relays with existing SCADA/DMS system via RS485 Modbus/IEC103 protocol (If Required)
(v) Submission of As-Built drawings, Test Reports, and Maintenance Manuals.
Note:-relay setting fault record data downloading training will be provided by Supplier in free of cost. | 17 | Each Job | 37,000 ₹6,29,000 | 24,000 ₹4,08,000 Lowest | 35,500 ₹6,03,500 |
| 2.00 | Supply and fixing as in replacement in replacement of Float-cum-Boost Battery Charger (FCBC) Supply of 110V DC, 50A FCBC (Thyristor Based), Input: 415V AC, 3-Phase. Output: Float 121V/Boost 126.5V. Feature: Digital Metering, Alarms (DC High/Low, AC Fail, Earth Fault). all as specified and directed.
Note:- The quoted rates are inclusive of Dismantling of existing old/defective battery charger and mechanical modification of panel (if required) and Installation & Commissioning Installation, testing (Capacity Discharge Test), and commissioning of Battery & Charger at 66kV Substation. | 1 | Each Job | 2,50,000 ₹2,50,000 | 1,90,000 ₹1,90,000 | 1,25,000 ₹1,25,000 Lowest |
| 3.00 | Material and labour for Batteries in replacement of 2V 100 AH Cell Model UPST100 VRLA type battery in charged condition alongwith suitable size of stand and accessories complete all as directed by EIC. | 10 | Each Set | 4,000 ₹40,000 | 2,500 ₹25,000 Lowest | 5,800 ₹58,000 |
| 4.00 | Supply and fixing as in replacement in replacement of Battery Bank (24V DC, 100AH) Bank Consisting of 12 Nos. of 2V Cells connected in series & supply of 24V DC, 100AH VRLA (SMF) Battery all as specified and directed.
Note:- The quoted rates are inclusive of Supply of MS Step-type Battery Rack with acid resistant painted, inter cell connection (Lead coated copper, and transparent terminal covers. | 2 | Each Job | 45,000 ₹90,000 | 40,000 ₹80,000 Lowest | 67,000 ₹1,34,000 |
| 5.00 | Supply and fixing as in replacement in replacement Float-cum-Boost Battery Charger of 24V DC, 50A FCBC (Thyristor Based). Input: 415V AC, 3-Phase. Output: Float 27V/Boost 28.5V. Feature: Digital Metering, Alarms (DC High/Low, AC Fail, Earth Fault).
Note:- The quoted rates are inclusive of Dismantling of existing old/defective battery charger and mechanical modification of panel (if required) and Installation & Commissioning Installation, testing (Capacity Discharge Test), and commissioning of Battery & Charger at Substation. | 2 | Each Job | 1,50,000 ₹3,00,000 | 60,000 ₹1,20,000 Lowest | 76,000 ₹1,52,000 |
| 6.00 | Material and labour for complete servicing, calibration and testing of Relay Coordination & Arc Flash Study for 66kV System (2 Incomers + 2 Transformers) and 11kV System connected feeder including C&R panel etc complete Using Licensed ETAP Software, relay testing calibration and setting upgradation complete all as specified and directed by EIC.
Notes (The quoted rates are inclusive of the following) :-
(i) Arc Flash PPE Suits (including Hood, Gloves, and Shoes) - Rating as per Arc Flash Analysis Report.
(ii) Arc Flash Boundary Marking (Floor Marking/Taping) as per study results.
(iii) 11kV Discharge/Earth Rod (Tested & Certified).
(iv) 66kV Extra Heavy-Duty Earth Rod with discharge cable.
(v) Insulated Rescue Rod (Life Saving Hook) for Substation Safety.
(vii) 3-Day Technical Training on Relay Operation, Coordination Benefits, and Arc Flash Safety.
(viii) Post-Execution Support: 3 Site Visits in a year for fault analysis/rectification. | 1 | Each Job | 2,50,000 ₹2,50,000 | 75,000 ₹75,000 Lowest | 76,000 ₹76,000 |
| 7.00 | Material and labour for complete servicing, calibration and testing of Relay Coordination & Arc Flash Study for 11 kV System and connected feeder installled at ESC Power House etc complete Using Licensed ETAP Software, relay testing calibration and setting upgradation complete all as specified and directed by EIC.
Notes (The quoted rates are inclusive of the following) :-
(i) Arc Flash PPE Suits (including Hood, Gloves, and Shoes) - Rating as per Arc Flash Analysis Report.
(ii) Arc Flash Boundary Marking (Floor Marking/Taping) as per study results.
(iii) 11kV Discharge/Earth Rod (Tested & Certified).
(iv) 11kV Extra Heavy-Duty Earth Rod with discharge cable.
(v) Insulated Rescue Rod (Life Saving Hook) for Substation Safety.
(vii) 3-Day Technical Training on Relay Operation, Coordination Benefits, and Arc Flash Safety.
(viii) Post-Execution Support: 3 Site Visits in a year for fault analysis/rectification. | 1 | Each Job | 25,000 ₹25,000 | 19,500 ₹19,500 Lowest | 76,000 ₹76,000 |
| 8.00 | All as per item No 7.00 here-in-before but for PS -1 Feeder,11 KV Sub Station. | 1 | Each Job | 20,000 ₹20,000 | 19,500 ₹19,500 Lowest | 76,000 ₹76,000 |
| 9.00 | All as per item No 7.00 here-in-before but for PS -2 Feeder,11 KV Sub Station. | 1 | Each Job | 15,000 ₹15,000 Lowest | 19,500 ₹19,500 | 76,000 ₹76,000 |
| 10.00 | All as per item No 7.00 here-in-before but for ETB Feeder,11 KV Sub Station. | 1 | Each Job | 10,000 ₹10,000 Lowest | 19,500 ₹19,500 | 76,000 ₹76,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Jun 2026, 6:00 pmClosed
CWE (AF) Ambala
HQ CWE (AF) Ambala Cantt-133001
CWE/AF AMB/AMB-T05/2026-27 REPAIR AND MAINT OF PROTECTION SYSTEM CONTROL PANELS CABLES RELAY CALIBRATION AND OTHER ASSOCIATED WORKS AT AF STN AMBALA UNDER GE AF AMBALA
2026_MES_767165_1
CWE/AF AMB/AMB-T05/2026-27
Open Tender
Civil Works
Item Rate
180 days
Ambala
For MES enlisted contractor Class D Category b ii and for un-enlisted contractor
refer NIT
8 documents required · 8 mandatory
₹500
GE (AF) Ambala
₹80,000
Yes
27 Aug 2026
22 May 2026
15 Jun 2026
22 May 2026
13 Jun 2026
7 Jun 2026
22 May 2026 - 6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing as in replacement of non directional outgiong and E/Frelay with RS485 common port and 1A/5A universal CT inputs event record & DR with numerical relay for VCB tripping system (3 OC + 01 earth fault and high set instantaneous protection in single unit ) suitable for operation on 24V to 110V DC all as per existing make & model all as specified and directed. (Note : existing relays are IDMT type electromagnetic type)
(Make : CG/Scheider/ABB/Siemen)
Notes (The quoted rates are inclusive of the following) :-
(i) Dismantling of existing old/defective relays and mechanical modification of panel cutout (if required).
(ii) Control wiring, Ferruling, and Luting of secondary connections as per new wiring.
(iii) Secondary Injection Testing, Pickup / Timing tests, and Relay Parameterization after Relay Co-ordination Test Report
(iv) Integration of Relays with existing SCADA/DMS system via RS485 Modbus/IEC103 protocol (If Required)
(v) Submission of As-Built drawings, Test Reports, and Maintenance Manuals.
Note:-relay setting fault record data downloading training will be provided by Supplier in free of cost. | 17 | Each Job | - | - |
| 2 | Supply and fixing as in replacement in replacement of Float-cum-Boost Battery Charger (FCBC) Supply of 110V DC, 50A FCBC (Thyristor Based), Input: 415V AC, 3-Phase. Output: Float 121V/Boost 126.5V. Feature: Digital Metering, Alarms (DC High/Low, AC Fail, Earth Fault). Mako: Amara Raja/Statcon/Mass-Tech all as specified and directed.
Note:- The quoted rates are inclusive of Dismantling of existing old/defective battery charger and mechanical modification of panel (if required) and Installation & Commissioning Installation, testing (Capacity Discharge Test), and commissioning of Battery & Charger at 66kV Substation | 1 | Each Job | - | - |
| 3 | Material and labour for Batteries in replacement of 2V 100 AH Cell Model UPST100 VRLA type battery in charged condition alongwith suitable size of stand and accessories complete all as directed by EIC. | 10 | Each Set | - | - |
| 4 | Supply and fixing as in replacement in replacement of Battery Bank (24V DC, 160AH) Bank Consisting of 12 Nos. of 2V Cells connected in series. Make: Amara Raja Supply of 24V DC, 160AH VRLA (SMF) Battery all as specified and directed.
Note:- The quoted rates are inclusive of Supply of MS Step-type Battery Rack with acid resistant painted, inter cell connection (Lead coated copper, and transparent terminal covers. | 2 | Each Job | - | - |
| 5 | Supply and fixing as in replacement in replacement Float-cum-Boost Battery Charger of 24V DC, 50A FCBC (Thyristor Based). Input: 415V AC, 3-Phase. Output: Float 27V/Boost 28.5V. Feature: Digital Metering, Alarms (DC High/Low, AC Fail, Earth Fault). Make: Amara Raja/Statcon/Mass-Tech.
Note:- The quoted rates are inclusive of Dismantling of existing old/defective battery charger and mechanical modification of panel (if required) and Installation & Commissioning Installation, testing (Capacity Discharge Test), and commissioning of Battery & Charger at Substation. | 2 | Each Job | - | - |
| 6 | Material and labour for complete servicing, calibration and testing of Relay Coordination & Arc Flash Study for 66kV System (2 Incomers + 2 Transformers) and 11kV System connected feeder including C&R panel etc complete Using Licensed ETAP Software, relay testing calibration and setting upgradation complete all as specified and directed by EIC.
Notes (The quoted rates are inclusive of the following) :-
(i) Arc Flash PPE Suits (including Hood, Gloves, and Shoes) - Rating as per Arc Flash Analysis Report.
(ii) Arc Flash Boundary Marking (Floor Marking/Taping) as per study results.
(iii) 11kV Discharge/Earth Rod (Tested & Certified).
(iv) 66kV Extra Heavy-Duty Earth Rod with discharge cable.
(v) Insulated Rescue Rod (Life Saving Hook) for Substation Safety.
(vii) 3-Day Technical Training on Relay Operation, Coordination Benefits, and Arc Flash Safety.
(viii) Post-Execution Support: 3 Site Visits in a year for fault analysis/rectification. | 1 | Each Job | - | - |
| 7 | Material and labour for complete servicing, calibration and testing of Relay Coordination & Arc Flash Study for 11 kV System and connected feeder installled at ESC Power House etc complete Using Licensed ETAP Software, relay testing calibration and setting upgradation complete all as specified and directed by EIC.
Notes (The quoted rates are inclusive of the following) :-
(i) Arc Flash PPE Suits (including Hood, Gloves, and Shoes) - Rating as per Arc Flash Analysis Report.
(ii) Arc Flash Boundary Marking (Floor Marking/Taping) as per study results.
(iii) 11kV Discharge/Earth Rod (Tested & Certified).
(iv) 11kV Extra Heavy-Duty Earth Rod with discharge cable.
(v) Insulated Rescue Rod (Life Saving Hook) for Substation Safety.
(vii) 3-Day Technical Training on Relay Operation, Coordination Benefits, and Arc Flash Safety.
(viii) Post-Execution Support: 3 Site Visits in a year for fault analysis/rectification. | 1 | Each Job | - | - |
| 8 | All as per item No 7.00 here-in-before but for PS -1 Feeder,11 KV Sub Station. | 1 | Each Job | - | - |
| 9 | All as per item No 7.00 here-in-before but for PS -2 Feeder,11 KV Sub Station. | 1 | Each Job | - | - |
| 10 | All as per item No 7.00 here-in-before but for ETB Feeder,11 KV Sub Station. | 1 | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender05T.pdf
Tender Documents • 0.77 MB
BOQ_859167.xls
BOQ • 2.50 MB
Date052.pdf
PDF • 0.11 MB
Dateextension1.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .