Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC BID IS LOWEST AND REASONABLE | |
| 2 | L2₹19.1 L+₹1.6 L (9.19%)Rejected-AOC | L2 | Rejected-AOC BID IS NOT LOWEST AND REASONABLE | |
| 3 | L3₹19.8 L+₹2.3 L (13.4%)Rejected-AOC | L3 | Rejected-AOC BID IS NOT LOWEST AND REASONABLE | |
| 4 | L4₹20.2 L+₹2.7 L (15.5%)Rejected-AOC | L4 | Rejected-AOC BID IS NOT LOWEST AND REASONABLE | |
| 5 | L5₹20.5 L+₹3.0 L (17.2%)Rejected-AOC | L5 | Rejected-AOC BID IS NOT LOWEST AND REASONABLE |
Tender Value
Refer Docs
EMD Value
₹36,780
Closing Date
22 Mar 2021, 6:00 pmClosed
GE RAMGARH CANTT
GE RAMGARH CANTT, JHARKHAND, PIN 829122
Provn of Revenue work Toilet (01xWC and 01 x urinal) near Ration Store Bldg No. P-381 Provn of MINOR WORKS Addn Altn to kitchen, toilet and bathroom in bldg No. T-16 1 T-16 -4 T-16A T-11 A3 T-17 2 T-17 3 MES Md Accn, Provn of Soakage pit and sept
2021_MES_417688_2
8300/3028/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH
CLASS E CAT a i
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH CANTT
₹36,780
Yes
25 Mar 2021
9 Mar 2021
24 Mar 2021
9 Mar 2021
22 Mar 2021
9 Mar 2021
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and as directed. (6)
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc., or for foundation, manholes etc., and getting out in soft/ loose soil, complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed. (6+6.75+5)
Removing excavated materials exc 250 m and n.exc 500m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed.
M & L for PCC (1:4:8) type D2 40mm graded stone aggregate as in foundation, sub base, filling and mass concrete etc., complete all as specified. (0.5+1.89+1.7)
M & L for brick work with sub class 'B' bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 50 Kg/Sqcm) old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 50 Kg/Sqcm) old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4), complete all as specified and as directed. (5+10.06+7)
M & L 50mm thick PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in for Damp proof course (DPC) mixed with [email protected]% by weight of cement. (WPC shall be measured and paid separately), complete all as specified and as directed.
M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in lintel beam, cantilever, bressumers supported on walls, beams and column and the like, complete all as specified and as directed.
M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in slab supported on walls beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed.
M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in chajja, complete all as specified and as directed.
M & L for formwork to soffit of suspended slab such as roof slab, floor slabs, landings and similar work n.exc 200mm thick (horizontal or sloping), complete all as specified and as directed. (6.9+13.5+9.20)
M & L for formwork to edges of concrete flats, breaks in floor, window cills, concrete railings, openings in concrete walls, floor and roofs exc 20 cm wide and sides of RCC/PCC bands in wall horizontal or sloping or similar work, exc 10cm but n.exc 20 cm, complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in wall horizontal or sloping or similar work, exc 10cm but n.exc 20 cm, complete all as specified and as directed. (12+29.70+30)
M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges, complete all as specified and as directed.
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed. (80+257.85+35+150)
S & F mild steel TMT bars 5mm dia and over as in stirrups, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
M & L for plastering 10mm thick in cement mortar (1:3) on fair faces of concrete finished even and smooth without using extra cement, neeru finished, complete all as specified and as directed.
M & L for rendering 15mm thick in CM (1:4) finishing surface even and smooth without using extra cement, on brick work or concrete surfaces, complete all as specified and as directed. (35+60.75+34)
M & L for plastering 10mm thick on fair faces of brickwork or concrete in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed.
M & L for plastering 5mm thick on fair faces of brickwork or concrete, ceiling, chajjas etc in cement mortar (1:3) finished even and smooth without using extra cement, complete all as specified and as directed.
M & L for preparation of newly plastered surface and applying two coats of cement base paint over a coat of cement base primer, complete all as specified and as directed.
M & L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L preparation of new plastered surfaces of ceiling, chajja, fascia, and applying three coats of white wash complete all as specified and directed.
M & L for 100mm thick PCC (1:4:8) type D2 40mm graded stone aggregate as in sub base of floor, etc., complete all as specified.
M & L for 75mm thick Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection finished even and fair without using extra cement including 10 mm wide groove n exc. 3.00 mtr in length, filled the groove with mastic, complete all as specified and as directed.
Hardcore of broken bricks of gauge n exc 63mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
M & L 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor and finished even and smooth without using extra cement, complete all as specified and as directed.
M & L for 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. (6.1+66)
M & L for 10mm bedding layers in cement mortar 1:4, complete all as specified and directed. (15+165)
M & L for non skid ceramic tiles of size 300x300x 7-8 mm thick, coloured as in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 300x200X 6 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, complete all as specified and as directed.
M & L for solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixing in opening, complete all as specified and as directed.
M & L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement fixing with the frame at site as per manufacturerer's instructions, complete all as specified and directed.
M & L for providing precast cement concrete louvres and jalies, 40 mm thick (measured solid), type B0, (1:2:4), using 12.5 mm graded aggregate) (RCC jali) including all mouldings, excluding frame set in CM (1:4), complete all as specified and as directed.
S & F aluminium anodised door stopper with rubber shoes of size minimum 50 mm long, complete all as specified and as directed.
S & F Aluminium anodised barrel tower bolts 200 mm long of extruded section, complete all as specified and as directed.
S & F 100 mm size butt hinges medium weight cold rolled mild steel and fixed, complete all as specified and as directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed. (1+3)
S & F Aluminium anodised handles 150 mm long of cast type, complete all as specified and as directed.
M & L for cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate as in bed blocks, fillings for holdfast etc., complete all as specified and as directed.
S & F rotational moulded poly-ethylene water storage tanks of 500 ltr capacity (cylindrical vertical with closed top) (double layers) hoisted and fixed in position complete all as specified and directed.
S & F 20mm PVC ball, brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule, complete all as specified and directed.
M & L for cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate as in base of PVC tank including necessary formwork, complete all as specified and as directed.
S & F for GI tubing medium grade including all types of fittings of ISI marked laid in walls/ceiling/floor suitable for 15 mm bore, complete all as specified and as directed. (6+15)
S & F for GI tubing medium grade including all types of fittings of ISI marked laid in walls/ceiling/floor suitable for 20 mm bore, complete all as specified and as directed. (6+15)
S & F stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions of bore 20mm complete all as specified and directed and as directed. (1+5)
S & F stop cock, fancy type, brass chromium plated with long shank (concealed type) with CP wall cap, 15mm bore, complete all as specified and directed and as directed. (3+5)
S & F vitreous China urinal, half stall type (back to corner wall type) including providing and fixing plug, bedding urinal against wall in cement mortar (1:2) securing urinal to plug with and including 60 mm brass long screw, pointing around urinal back in cement mortar, flush pipe, waste pipe, waste fittings, grating and union for discharge pipe, (excluding of fixing of supply pipe to flushing cistern, trap and waste pipe), complete all as specified and as directed.
S & F vitreous China wash hand basin, white, flat back, size 550X400mm including chain and plug, and porcelain stopper, cast iron brackets, waste pipe including cutting for and pinning in ends of brackets or erecting stand and making good disturbed surfaces in CM (1:3), complete all as specified and directed.Make:- Hindware/Parryware/Cera or of equivalent approved make.
S & F 15 mm bore fancy type pillar tap, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT' or 'COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F brass chromium plated shower rose 50 mm size with swivel joint any size, complete all as specified and as directed.
S & F flushing cistern low level, PVC 10 lit capacity syphon action type, valveless with inlet ball valve, float valve and handle including brackets fixed to wall and 32mm dia PVC flush pipe, including connections and making good the disturbed surfaces in cement mortar (1:3), complete all as specified and as directed. (1+5)
S & F for vitreous china wash down water closet, pedestal pattern white (excluding fixing bolt, flushing cistern and flush pipe) but including connection to drain or outgoing pipe and to flushing pipe, antisyphonage pipe, etc., and including seat cover for pedestal pan , complete all as specified and directed.
S & F Brass chromium plated towel rail, 20mm dia, D type, 60 cm long between flanges, complete all as specified and as directed.
M & L PVC (SWR) pipes 110 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
M & L PVC (SWR) pipes 110 mm bore, single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. (1.5+15)
M & L PVC (SWR) pipes 75 mm bore, single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed. (2.5+20)
M & L PVC (SWR) pipes 75 mm bore, single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. (2.5+5)
S & F (SWR) 110 mm dia bends any radius with rubber ring joints, complete all as specified and directed. (2+10)
S & F (SWR) 75 mm dia bends any radius with rubber ring joints, complete all as specified and directed. (2+5)
S & F (SWR) 110 mm bore junction, (double Tee) equal or unequal, complete all as specified and directed. (1+5)
S & F (SWR) 75 mm bore junction, (double Tee) equal or unequal, complete all as specified and directed. (1+5)
S & F (SWR) 110mm bore branch piece, double (double Y), equal or unequal, complete all as specified and directed.
S & F (SWR) 75mm bore branch piece, double (double Y), equal or unequal, complete all as specified and directed.
S & F (SWR) 110mm vent cowl, complete all as specified and directed. (1+5)
S & F (SWR) 75mm vent cowl, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm dia pipe, complete all as specified and as directed. (1+2.0+2)
M & L for Salt glazed stone ware (SGSW) gully traps, square or round mouthed type P 150mm x 150 mm , complete all as specified and directed.
M & L PVC (SWR) pipes 150 mm bore, single socketed in any length with rubber ring joints laid in trenches or floors, complete all as specified and directed. (4+16+10)
M & L for concrete bed to drain pipes including packing under, and hunching against the sides of pipes after they are laid and tested in cement mortar 1:3:6 type C-2, using 40 mm graded stone aggregate for 150mm pipe, complete all as specified and directed. (4+16+10)
Excavation over area for foundation etc, n.exc 1.5 m deep and n.exc 10 Sqm on plan wide and getting out in soft/loose soil. (35.59+25)
Excavation over area for foundation etc, exc 1.5 m deep but n.exc 3.00m and n.exc 10 Sqm on plan wide and getting out in soft/loose soil. (12.77+2)
M & L for brickwork , in one brick thick wall honey comb walling built in cement mortar (1:4), complete all as specified and as directed. (19.71+11.20)
M & L Brick work with sub class 'B' bricks straight or curved on plan any radius as in half brick thick partition wall built in cement mortar 1:4 complete all as specified and directed (9.72+8+5)
M & L for RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in slab supported on walls beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. (2.3+1.7)
Removing excavated materials n.exc 50 m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed. (41.66+21)
Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits and soakage wells, complete all as specified and as directed. (2.7+2)
Taking down cement plaster of any description and in any position including raking out joints, hacking for key scrubbing down with water etc and removing of debris from site, complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exc 15 cm thickness (above or below ground level), complete all as specified and directed.( 3 + 11.46)
M & L for 75mm thick PCC (1:4:8) type D2 40mm graded stone aggregate as in sub base of floor, etc., complete all as specified.
M & L non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular) area of each tile exe.0.11 sqm but n.exe.0.18 sqm, in floor, joint free tiles etc set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed.
M & L for glazed ceramic coloured tiles 300x450X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillar etc., complete all as specified and directed. (1.5+0.5)
Demolition of cement concrete (RCC) as in precast cover of manholes etc., (reinforcement cut as required to facilitate demolition), complete all as specified and directed.
M & L for providing precast cement concrete type B1 (1:2:4) (20mm graded aggregate) including chamfers weatherings, throating etc., setting in mortar complete with joints to match, complete all as specified and directed.
M & L for Machine cut Cudappah stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, complete all as specified and as directed.
Taking down chawkhat with shutter (without taking of shutter from the frame) exc 1.5 sqm and n.exc 4 Sqm each, complete all as specified and directed by Engr-in-Charge .
M & L chowkhat second class hard wood and frames wrought, framed rebated on the solid rounded or chamfered , put together with gluepinned at joints complete all as specified and directed by Engr-In-Charge
S & F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side either decorative face veneer both face with lipping/frame, complete all as per specified and directed.
M & L painting on new wooden based surfaces of any description not otherwise described over 10cm width or girth applying two coat synthetic enamel paint over one coat of pink primer including preparation of surfaces complete all as specified and directed by Engr-In-Charge .
S & F Aluminium anodised barrel tower bolts 150 mm long of extruded section, complete all as specified and as directed.
S & F butt hinges 100mm with galvanised mild steel hinges pin and fixed, complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing or removing to store yard of size 15 mm bore, complete all as directed.
Taking up or down steel tubing and connections including cleaning for refixing or removing to store yard of size 20 mm bore, complete all as directed.
S & F 15mm dia bore bib tap, cast copper alloy, chromium plated, fancy type, with capstan head handle, screwed for iron pipe after taking down old brass bib tap, complete all as specified and directed.
S & F in repair vitreous china squatting pan, 'Orissa pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage connection pipe etc., complete making good disturb surface with existing finish of floor, complete all as specified and directed.
S & F 450 mm long PVC connection 15 mm size with brass check nuts at both ends, complete all as specified and as directed
M & L for 75mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed.
S & F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil, complete all as specified and as directed. (18.9+20)
Dismantling old broken floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M & L for 10 mm thick light coloured vitrified ceramic tiles of size in floors, n.exc 0.36 Sq m set and jointed in neat cement slurry and pointed in coloured cement to match over and including 20 mm thick screed bed in cement mortar (1:4), complete all as specified and as directed.
M & L for 10 mm thick light coloured vitrified ceramic tiles of size in skirting, n.exc 0.36 Sq m set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed in cement mortar (1:3), complete all as specified and as directed.
M & L for cement concrete type B1, 1:2:4 (using 12.5 mm graded aggregate) in levelling courses, coping, window cill etc., complete all as specified and directed.
M & L for 75mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor finished even and fair without using extra cement, complete all as specified and as directed.
M & L for laying of 40 mm thick bitumen mastic flooring (wearing course as per specification) with industrial bitumen of grade 85/25 conforming to IS:702, prepared MANUALLY and laid to required level and slope, including providing anti-skid surface with bitumen precoated fine grained hard stone chipping of approved size at rate of 0.005 Cum per 10 Sqm and at approximate spacing of 10 cm centre to centre in both directions, pressed into surface protuding 1 mm to 4 mm over mastic surface (considering bitumen using 10.2% of total weight) including preparation of surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc., and applying priming/tack coat with paving bituminous primer @ 5 Kg per 10 Sqm, complete all as specified and as directed.
M & L for point wiring for one light/ fan point controlled by one switch with 1100 volt grade PVC insulated FRLS 1.5 Sq mm single solid stranded copper conductor cable with continuous earth wire of 1.5 Sq mm solid stranded copper conductor cable, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed sunken boxes made out of not less than 1.6 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc complete all as specified and directed.
M & L for submain wiring with two single core 6.0 sqmm PVC insulated FRLS multistranded copper conductor cable and one run of 6.0 Sqmm PVC unsulated unsheathed FRLS multistranded copper conductor cable for earth wire drawn in and including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20mm dia in including taking down of existing conduit or batten complete and making good disturbed surface wall, complete all as specified and as directed. Note :- 2 runs of 6.0 Sqmm cable and one run of earth wire 6.0 Sq mm shall be measured as one unit length.
S & F switch piano type 5 Amp 230 volt one way flush type complete all as specified and as directed.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S & F angle holder complete all as specified and as directed.
S & F LED lamp 9 Watts, complete all as specified and as directed.
S & F LED tube light along with fixtures 18 Watts, complete all as specified and as directed.
Supply and fixing and commissioning of UPS for 1 hr back up, along with battery bank (inclusive of batteries, rack, connecting links etc.) as per the following technical specifications complete including connected accessories, complete all as specified and as directed. Make of UPS: Microtek, I Maxx Series or equivalent as approved by GE from list of approved makes and Make of battery: Exide/Luminious/Amron or its equivalent as approved by GE from list of approved Makes. (a) FOR UPS (i) Type- Microprocessor controlled (ii) Capacity - 5KVA/4000 Watts (iii) Charging style - Boost & Float/trickle (iv) Input voltage range - 160-270 VAC, Single Phase (v) Input frequency range- 45 to 60 Hz (vi) Input Power factor- 0.98 (vii) Output voltage to Load - 230 VAC (viii) Output Power Factor - 0.9 (ix) Voltage Regulation - ± 1% (x) Output frequency - 47-53 Hz (xi) Current crest ratio - 3.1 (xii) Tonal Harmonic distortion - within 3% for linear loads & 6% for non linear loads (xiii) AC mode to Battery mode - Bumpless transfer (xiv) Inverter to bypass transfer - 5 ms (xv) Waveform shape - Pure Sinewave (xvi) Efficiency in AC mode - 90% (xvii) Efficiency in Battery mode - 90% or better (xviii) Overload sustaining capability - Shall be able to sustain for at least 60 seconds in case of 125% load without abnormal behavior. (xix) Battery charging current - Shall be capable of charging the fully drainage battery in around 12 hours. (xx) Battery charging Voltage - Suitable for battery of up 192V, 120 Ah (xxi) Display - UPS shall preferably have Multi line LCD display which shall show various status parameters of the system (xxii) Audio indications - The UPS shall give distinct audio signals/alarms for battery mode, low battery and other faults (xxiii) Ambient Conditions - Up to 40°C @ 95% RH (xxiv) Cooling - Fans shall be available for internal heat dissipation of UPS (xxv) Protection - Protection against short circuit, Overload, Low input voltage, Surge in input voltage as per UL 1449, Over heat in the UPS, etc, shall be availabe.
(b) FOR BATTERY BANK (i) Battery Type - VRLA, Sealed maintenance free (ii) Battery Voltage - 12 V DC, nominal (iii) Battery Capacity - Minimum 120 Ah (iv) Voltage of Battery bank - Battery bank shall be configured to suit the charging capacity of UPS (v) number of batteries in bank - 16 or equivalent to 1920 Ah or better 30 or equivalent to 3600 Ah or better (vi) Power discharge rating @ NTP - 3000 W for 10 min & 1000 W for 1 hour, or better (vii) Terninals - Copper (viii) Battery outlet body material - Polypropylene Co-polymer (ix) Battery Charging voltage - 13.5 VDC approx (x) Battery charging current - Batteries shall be able to accept up to 9 Amp charging current (xi) Life expectancy - 4 years or more, (xii) Compliance of standards -UL 2003 (MH26669), JIS C 8702, IEC 60896 2004, ISO14001:2004 and ISO9901.2000 (xiii) Test - Shock test (drop test) Large current discharge test, Vent valve function test, Over discharge test, Vibration test, Oven test, Coldproof test, Heat cycle test. Short circuit test (xv) Self discharge rate (max) - within 1% of capacity per week (xv) Racks, integration, testing & commissioning- Suitable seismically stable, durable, rust and dust proof, high strength rack for mounting the batteries shall be suppplied along with battery bank . Note: Contractor shall be responsible for installation of rack and batteries, connection of all batteries with UPS with required of suitable size, testing and commissioning at site.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6.0 Sqmm 2 core, complete all as specified and as directed.
upadhyay engineers and consultant
Modernage Constructions Pvt. Ltd.
M/S Bhushan Kumar Jain
M/s friend enterprises
M/S Kunwar Construction
Balaji Construction And Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .