Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹31.4 Laccepted-aoc | ₹31.4 L | accepted-aoc |
Tender Value
₹33.8 L
EMD Value
₹33,756
Closing Date
18 Aug 2026, 2:30 pmClosed
Commissioner Municipal Corporation of Rajahmundry
Rajahmundry
Supply, delivery and Installation of 160 KVA CPCB IV + Diesel Generator Set for Model Colony Booster Clear Water Pump House of RMC.
971525
175/MCR/General/2026-27
OPEN - NCB
Civil Works
EAST GODAVARI, ANDHRA PRADESH
10 documents required · 6 mandatory · 4 optional
₹1,195
₹33,756
20 Sept 2026
3 Aug 2026
3 Aug 2026
Supply Installation Testing And commissioning of CPCB IV+ DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.
Alternator 1. 1500 RPM, 1P or 3P, Brushless type, screen protected, revolving field, Self-excited alternator conforming to IS/IEC 60034-1 IP23, with standard Alternator Protection (over voltage, over speed & Under voltage) 2. A reliable long life with superior class 'H' insulation with temperature rise to Class H Diesel Engine: Engine: Engine should comprise of Silencer, Electronic governor from >25 KVA & above, suitable rating battery , Battery charging alternator, battery charger , Inbuilt Fuel tank with fuel pipe, AVM pads , Control panel with 3P MCCB of suitable rating with short circuit protections ( 25kA,36kA, 50kA) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, KWH, KVAR, Hrs etc.), The diesel engine shall be capable of providing 10% overload for 1 Hr for every 11 Hrs of continuous running at full load. The DG set shall be supplied as per OEM specifications and shall be tested at site along with below.
1. CRDI Engine >25 KVA DG set, 2. Water cooled Radiator coupled to engine, 3. Dry type air cleaner with service indicator, 4. First fill of lube oil, Coolant & first fill of Diesel, 5. Electrical starter motor with soft start System, 6. Battery charging alternator, 7. Remote Monitor system >58.5 KVA & Above, 8. 2 years / 5000 Hrs Warranty from commissioning or 30-month form supply, 9. Emission control system - EGR & (DOC, SCR for >75 KVA DG set), 10.10 Mtrs Exhaust pipe from Silencer
Genset Controller: 1. Microprocessor based genset monitoring, metering and control system with full graphics LCD display for easy front panel access. 2. AMF relay, manual and remote start / stop modesfor 1-ph & 3-ph gensets, 3. Backlit and full graphics display with power saving feature, 4. Engine parameter monitoring -Lube oil pressure, Engine coolant temperature, Fuel level, Battery voltage, Engine running hours, 5. AC Alternator parameter monitoring -Voltage L-N & L_L, Current, kW, kVA (Phase & Total), Frequency, kWH, PF 6. Genset Protection: Engine: Low lube oil pressure, High coolant temperature, Battery High/Low Volts, Fail to Start, Sensor failure, Low fuel level, Overspeed AC Alternator: Over/Under Voltage, Over/Under, Frequency, Loss of AC sensing, Over frequency, Over Current, kW Overload, Unbalancing load, 7. Maintenance notification based on Engine Run Hour & due date, 8.Communication: USB port, RS485, CAN, 9.30-50 Event logs
Acoustic Enclosure: 1. Specially designed to meet stringent MOEF/CPCB IV+ norms 2. Weatherproof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.2 mm / 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.2mm /1.6 mm CRCA sheet and filled with PU Foam/Rockwood for Fire retardant acoustic and for better safety 3. Designed to operate in extreme climatic conditions in temperatures ranging from -10 deg to 55 deg without any external aid 4. Fabricated base frame with AVM pads. 5. Noise level is less than 75 db (A) at a distance of 1 Mtrs as per CPCB norms, complete in all respect. following capacity: Radiator Cooled and Turbocharged 125 kVA at 0.8 pf 415V 50Hz 3-Ø Engine Makes:Caterpillar/Cummins/Koel Green/Mahindra/Elmot power Gen/Ashok Leyland/Greaves Alternator Make:Leroy somer/Crompton Greaves/Stamford
Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: For 80 to 160 KVA
Supply and transportation of following XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part - I)./1554-I Makes: As per list of recommended brands as category I. Finolex/ Polycab/V-Guard 185 Sq mmX 3.5 core(ELE 4.1.1)
Earth work for Ordinary Soil excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 0.50Mtrs. Dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD/ 304 MORTH VP No. 484. for Manual Means upto 3Mtrs. Depth taking
Providing Sand Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH Including cost and conveyance of all materials and all labour charges etc., complete as per ss and as directed by the site engineer.
Providing Plain Cement concrete (1:4:8) (Cement: fine aggregate: coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard machine crushed granite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, excluding seigniorage charges, on all materials including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15cm layers finishing top surface to the required level curing etc. complete for finished item of work (APSS No. 402).
P.C.C. grade M 20 (MORD) Providing Plain Cement Concrete Nominal Mix (1:2:4) using using 20mm nominal size Graded hard stone aggregate, mechanically mixed, placed and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH. for Approaches etc. (for Mechanical Mixer) With Form Work
Providing independent earthing for important equipment with 100mm dia heavy gauge C.I(cast iron) pipe wth flange 2.5m long enclosed in CC/brick massonary chamber of 450m x 450m x 400mm with RCC slab cover dulyproviding stagged holes filling with salt and charcoal from the bottom of the pipe giving earth connecion from electrode through G.I Strip of 40x6mmx200mm length with all accessories and labour charges etc complete as directed by the departmental authorities.(mat-04139)
Supply and laying of 25mm x 3mm Copper Flat (0.663Kgs/1Mtr) Earth wire/ Strip in horizontal /Vertical run in Ground/ surface/ Recess including, riveting, soldering, saddles, making connection etc as required
Supply and delivery of 4 core, 2.5 Sq mm mm ISI marked FRLS/FRLS-H/HFFR/ZHFR PVC insulated flexible copper cables 1100V grade as per IS: 694/1990 & IS:17048/ 2018 specification for copper cable Makes: Finolex / RR kabel / Havells/ Finecab/ KEI/ Polycab/ Gloster/ Goldmedal/ GM/ Fortune Arrt/ Anchor/ Million/ APAR (Anushakthi) including cost of materila and conveyance to work spot etc complete as directed by the departmental authorities
Labour charges for Panel board all connections, load balancing including necessary associated electrical related work including lugs, cable glands, termination of cables, etc., complete and all labour charegs etc complete as directed by the departmental authorities.
MS Fabrication work for Heavy trusses and purlins for sheds using MS I beams, MS channels, MS Angles, MS sheets etc., including cost of all materials, fabrication and errection work including one coat of redoxide complete as directed by the Departmental Authorities.
Supply of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colour
Labour charges for fixing of galvalume sheets including cost of all materials like screws,fasterns etc. complete as directed by the Site Engineer.
Supply of Roof Accessories medium size: Ridge, Barge Cap, Corner Trim, L- Flashing, Down Pipes, Gutter etc., with 0.50mm thick, Width: 0.585, Length: Maximum 2 1/2% Meters
Auto matic Capacitor bank panel board suitable for 160 KVA load including capacitor banks, necessary incoming MCCB's, out going MCB's etc., complete as directed by departmental Authorities.
Supply Installation Testing And commissioning of CPCB IV+ DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.
Alternator 1. 1500 RPM, 1P or 3P, Brushless type, screen protected, revolving field, Self-excited alternator conforming to IS/IEC 60034-1 IP23, with standard Alternator Protection (over voltage, over speed & Under voltage) 2. A reliable long life with superior class 'H' insulation with temperature rise to Class H Diesel Engine: Engine: Engine should comprise of Silencer, Electronic governor from >25 KVA & above, suitable rating battery , Battery charging alternator, battery charger , Inbuilt Fuel tank with fuel pipe, AVM pads , Control panel with 3P MCCB of suitable rating with short circuit protections ( 25kA,36kA, 50kA) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, KWH, KVAR, Hrs etc.), The diesel engine shall be capable of providing 10% overload for 1 Hr for every 11 Hrs of continuous running at full load. The DG set shall be supplied as per OEM specifications and shall be tested at site along with below.
1. CRDI Engine >25 KVA DG set, 2. Water cooled Radiator coupled to engine, 3. Dry type air cleaner with service indicator, 4. First fill of lube oil, Coolant & first fill of Diesel, 5. Electrical starter motor with soft start System, 6. Battery charging alternator, 7. Remote Monitor system >58.5 KVA & Above, 8. 2 years / 5000 Hrs Warranty from commissioning or 30-month form supply, 9. Emission control system - EGR & (DOC, SCR for >75 KVA DG set), 10.10 Mtrs Exhaust pipe from Silencer
Genset Controller: 1. Microprocessor based genset monitoring, metering and control system with full graphics LCD display for easy front panel access. 2. AMF relay, manual and remote start / stop modesfor 1-ph & 3-ph gensets, 3. Backlit and full graphics display with power saving feature, 4. Engine parameter monitoring -Lube oil pressure, Engine coolant temperature, Fuel level, Battery voltage, Engine running hours, 5. AC Alternator parameter monitoring -Voltage L-N & L_L, Current, kW, kVA (Phase & Total), Frequency, kWH, PF 6. Genset Protection: Engine: Low lube oil pressure, High coolant temperature, Battery High/Low Volts, Fail to Start, Sensor failure, Low fuel level, Overspeed AC Alternator: Over/Under Voltage, Over/Under, Frequency, Loss of AC sensing, Over frequency, Over Current, kW Overload, Unbalancing load, 7. Maintenance notification based on Engine Run Hour & due date, 8.Communication: USB port, RS485, CAN, 9.30-50 Event logs
Acoustic Enclosure: 1. Specially designed to meet stringent MOEF/CPCB IV+ norms 2. Weatherproof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.2 mm / 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.2mm /1.6 mm CRCA sheet and filled with PU Foam/Rockwood for Fire retardant acoustic and for better safety 3. Designed to operate in extreme climatic conditions in temperatures ranging from -10 deg to 55 deg without any external aid 4. Fabricated base frame with AVM pads. 5. Noise level is less than 75 db (A) at a distance of 1 Mtrs as per CPCB norms, complete in all respect. following capacity: Radiator Cooled and Turbocharged 125 kVA at 0.8 pf 415V 50Hz 3-Ø Engine Makes:Caterpillar/ Cummins/Koel Green/ Mahindra/ Elmot power Gen/ Ashok Leyland/ Greaves Alternator Make:Leroy somer/ Crompton Greaves/ Stamford
Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: For 80 to 160 KVA
Supply and transportation of following XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part - I)./1554-I Makes: As per list of recommended brands as category I. Finolex/ Polycab/V-Guard 185 Sq mmX 3.5 core(ELE 4.1.1)
Earth work for Ordinary Soil excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 0.50Mtrs. Dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD/ 304 MORTH VP No. 484. for Manual Means upto 3Mtrs. Depth taking
Providing Sand Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH Including cost and conveyance of all materials and all labour charges etc., complete as per ss and as directed by the site engineer.
Providing Plain Cement concrete (1:4:8) (Cement: fine aggregate: coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard machine crushed granite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, excluding seigniorage charges, on all materials including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15cm layers finishing top surface to the required level curing etc. complete for finished item of work (APSS No. 402).
P.C.C. grade M 20 (MORD) Providing Plain Cement Concrete Nominal Mix (1:2:4) using using 20mm nominal size Graded hard stone aggregate, mechanically mixed, placed and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH. for Approaches etc. (for Mechanical Mixer) With Form Work
Providing independent earthing for important equipment with 100mm dia heavy gauge C.I(cast iron) pipe wth flange 2.5m long enclosed in CC/brick massonary chamber of 450m x 450m x 400mm with RCC slab cover dulyproviding stagged holes filling with salt and charcoal from the bottom of the pipe giving earth connecion from electrode through G.I Strip of 40x6mmx200mm length with all accessories and labour charges etc complete as directed by the departmental authorities.(mat-04139)
Supply and laying of 25mm x 3mm Copper Flat (0.663Kgs/1Mtr) Earth wire/ Strip in horizontal /Vertical run in Ground/ surface/ Recess including, riveting, soldering, saddles, making connection etc as required
Supply and delivery of 4 core, 2.5 Sq mm mm ISI marked FRLS/FRLS-H/HFFR/ZHFR PVC insulated flexible copper cables 1100V grade as per IS: 694/1990 & IS:17048/ 2018 specification for copper cable Makes: Finolex / RR kabel / Havells/ Finecab/ KEI/ Polycab/ Gloster/ Goldmedal/ GM/ Fortune Arrt/ Anchor/ Million/ APAR (Anushakthi) including cost of materila and conveyance to work spot etc complete as directed by the departmental authorities
Labour charges for Panel board all connections, load balancing including necessary associated electrical related work including lugs, cable glands, termination of cables, etc., complete and all labour charegs etc complete as directed by the departmental authorities.
MS Fabrication work for Heavy trusses and purlins for sheds using MS I beams, MS channels, MS Angles, MS sheets etc., including cost of all materials, fabrication and errection work including one coat of redoxide complete as directed by the Departmental Authorities.
Supply of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colour
Labour charges for fixing of galvalume sheets including cost of all materials like screws,fasterns etc. complete as directed by the Site Engineer.
Supply of Roof Accessories medium size: Ridge, Barge Cap, Corner Trim, L- Flashing, Down Pipes, Gutter etc., with 0.50mm thick, Width: 0.585, Length: Maximum 2 1/2% Meters
Auto matic Capacitor bank panel board suitable for 160 KVA load including capacitor banks, necessary incoming MCCB's, out going MCB's etc., complete as directed by departmental Authorities.
Details of Maximum amount reimbursable to the Contractor.
1) Provision for GST @18%
2) Provision for NAC @ 0.10%
3) Provision for Seigniorage charges
4) DMF @30% on Seigniorage charges
5) MERIT @2% on Seigniorage charges
6) Consideration 100% on Seigniorage charges
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Doc 2026.doc
TENDER_DOCUMENT • 0.66 MB
Notice 2026.doc
TENDER_DOCUMENT • 0.10 MB
BOQ TS 13 Nit 175.xlsx
TENDER_DOCUMENT • 0.08 MB
Print TS 13 Nit 175.xls
TENDER_DOCUMENT • 0.06 MB
Contractor Information.pdf
TENDER_DOCUMENT • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .