Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | ₹11.3 L Quoted ₹11.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹12.3 L+₹43,750 (3.68%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | ₹12.3 L+₹43,750 (3.68%) | L2 | Rejected-AOC Not lowest |
| 3 | L3₹14.3 L+₹2.4 L (19.8%)Rejected-AOC | ₹14.3 L+₹2.4 L (19.8%) | L3 | Rejected-AOC Not lowest |
| 4 | L4₹18.2 L+₹6.3 L (53.0%)Rejected-AOC | ₹18.2 L+₹6.3 L (53.0%) | L4 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
Closing Date
7 Oct 2021, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR / REPLACEMENT OF UNSERVICEABLE ELECTRICAL FITTINGS AND FIXTURE, CEILING FAN, EXHAUST FAN IN 33 SU AND LEFT OVER POCKET IN DOMESTIC AREA AT AF STN JODHPUR
2021_MES_474601_1
8484/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
Exempted
28 Oct 2021
11 Sept 2021
9 Oct 2021
11 Sept 2021
7 Oct 2021
25 Sept 2021
Amount
Material & Labour for prepararion of old painted steel surface by cleaning of oils, dust and rust partical, scapping down old paint from steel tubular pole of 11 meter height, and apply two coats of aluminium paint over a coat of red oxide primer (upto full height of pole from the ground level) including painting of all MS cross arms, channels/angle iron etc complete, including, zebra painting with synthetic enamel paint, marking of MES pole Nos in 10 cm height with black synthetic enamel paint, complete all as directed by the Engineer-in-Charge.
Material & Labour for prepararion of old painted PCC pole surface by cleaning of oils, dust and rust partical, scapping down old paint, and apply two coats of super enamel synthetic paint (first quality) over a coat of cement primer in zebra pattern (upto 1.5 metres height of pole from the ground level) complete including marking of MES pole Nos in 10 cm height with black synthetic enamel paint, with & including painting of all MS cross arms, channels/angle iron etc complete all as directed by the Engineer-in-Charge.
Material & Labour for Pre-stressed concrete poles 9 metres long, size 152 mm x 152 mm at top and 152 mm x 260 mm at bottom, class 10, complying with requirement of IS-1678 of 1978 including painting the poles with two coats of synthetic enamel paint over a coat of primer in sky blue and white (15 cm high each) alternate strips upto 1.5 m height from top of PCC coping including numbering the poles in synthetic enamel paint, including necessary excavation & earthwork in any type of soil, PCC (1:4:8) in foundation , PCC (1:3:6) in coping , with and including dismantling & breaking the old PCC foundation,taking out of old unserviceable pole, and removal of all the debries out side MD land complete all as directed by the Engineer-in-Charge.
Material & labour in replacement of Stay assembly with galvanised stay strand of size 7/3.15mm complete with accessories including loop type insulator, stay clamps, stay plate of required size, excavation in any soil/ hard rock and PCC work etc for fixing of stay rod of 20mm complete all as specified and directed by the Engineer - in - Charge.
Material & labour for Unbinding ACSR conductor and insulators from the poles and restretching/restringing & fixing the same ACSR conductor of any size on same poles and binding the same with & including the new 2mm dia aluminium binding wire and making/tightening of jumpers at appropriate place to ACSR conductor complete all as specified and directed by the Engineer in Charge. Note :- All four wires between poles shall be considered as one length. Distance between pole to pole shall be considered as length of wires for the purpose of payment.
Material & labour in repairs for aluminium conductor, steel reinforced (ACSR) including 22 gauge aluminium binding wire, line connections and jumper etc (Squirrel, weasel & ferret) complete all as specified and directed by the Engineer-in-Charge. Note :- Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
Supply & fixing in repairs 100mm high, 65mm dia Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 1100 volts grade complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs 75mm high, 90mm dia Shackle type, porcelain, vitreous, white, brown or green insulator including one galvanised strap of 31x3mm with 12mm dia bolt, for 1100 volts grade complete all as specified and directed by the Engineer-in-Charge.
Material & labour in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed with and including apply two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by the Engineer in Charge.
Material & labour in replacement of 1100 Volt jumpers by weasel conductor at pole by new one, with PG clamp including nuts and bolts / connector for fixing / tightening two conductor of equal or unequal size complete all as specified and directed by the Engineer in Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by the Engineer-in-Charge.
Taking down sub main wiring any type any size complete all as specified and directed by the Engineer-in-Charge.
Taking down DB any type any size complete all as specified and directed by the Engineer-in-Charge.
Material and labour for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS-694 (Phase- Red/Blue/Yellow, Neutral - Black and earth continuity conductor - Green) drawing through existing steel /PVC conduit and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator including continuous earth wire with 1.5 sqmm PVC insulated 1100 volt grade IS-694 FRLS multi stranded but unsheathed copper conductor cable connected to main earth dolly for one Light/ Fan/Exhaust fan point controlled by one switch/regulator complete all as specified and directed by the Engineer in Charge.
All as per item No.14 here-in-before but for 5 pin 5 Amps socket outlet controlled by one switch on same board with other switches complete all as specified and directed by the Engineer in Charge.
All as per item No.14 here-in-before but for 5 pin 5 Amps socket outlet controlled by one switch on Independent board complete all as specified and directed by the Engineer in Charge.
All as per item No.14 here-in-before but with 2.5 Sqmm cable for independent one 6 pin 5/15 Amps socket outlet in and including 1.5 Sqmm PVC insulated copper conductor unsheathed 1100 Volt grade IS-694 FRLS cable for continous earth wire complete all as specified and directed by the Engineer in Charge.
Material and labour for point wiring complete with 2.5Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade IS-694 (Phase- Red/Blue/Yellow, Neutral - Black and earth continuity conductor - Green) drawn through and including PVC casing caping not less than 20mm x 12mm ISI marked ivory colour including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick phenolic laminated white sheet cover for mounting swiches, sockets and fan regulators complete for one Light/ Fan point controlled by one switch 5 amp one way complete all as specified and directed by the Engineer in Charge.
All as per item No.18 here-in-before but for 5 pin 5 Amps socket outlet controlled by one switch on same board with other switches complete all as specified and directed by the Engineer in Charge.
All as per item No.18 here-in-before but for 5 pin 5 Amps socket outlet controlled by one switch on Independent board complete all as specified and directed by the Engineer in Charge.
All as per item No.18 here-in-before but with 2.5 Sqmm cable for independent one 6 pin 5/15 Amps socket outlet in and including 1.5 Sqmm PVC insulated copper conductor unsheathed 1100 Volt grade IS-694 FRLS cable for continous earth wire complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs switch piano 5 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs switch piano 16 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs socket outlet flush type 5 pin 6 amps complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed by the Engineer in Charge.
Supply and fixing in repairs decorative LED tube light fitting 18 Watt with end caps and LED tube rod , pre wired for LED tube complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series, Single Pole (SP) 6 to 32 amps, having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series, Single Pole & Neutral (SPN), 40 to 63 amps, having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs MCBs of 'C' series, Triple Pole & Neutral (TPN), 40 to 63 amps, having breaking capacity 10 KA, including required wiring connections with copper lugs of suitable size provided in MCB DB complete all as specified and directed by the Engineer in Charge.
Supply and fixing factory made MCB distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by the Engineer in Charge.
Supply and fixing factory made MCB distribution board TPN, 440 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by the Engineer in Charge.
Taking down carefully and opening, dismantling of ceiling fans of any sweep, cutting and taking out old burnt/damaged winding/material by any means and material & labour for re-winding the same with supper enamelled copper wire of existing/same SWG including all insulating material as required as per standard practice, varnishing the same and drying, cleaning fan with recommended quality grease/oil, re-assembling including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length and testing complete all as specified and directed by Engr-in-charge.
Taking down carefully and opening, dismantling of exhaust fan 450mm sweep by any means and taking out old burnt/damaged winding/material by any means and material and labour for rewinding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan bearing/bushing and greasing/oiling the same with recommended quality grease/oil, reassembling and testing including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length complete all as specified and directed by Engr-in-charge.
All as per item No 33 herein above but exhaust fan 380 mm sweep all as specified & directed. Note for item no.32 to 34 :- Spare parts if required to be replaced, shall be measured and paid seperately under srl item no.35 to 45 of BOQ here in after as supply only.
Supply only bearing of ceiling/exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 415 Volts, 50 Hz 2.5 MFD complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 415 Volts, 50 Hz 4 MFD complete all as specified and directed by Engineer-in-Charge.
Supply only bush suitable for ceiling/ exhaust fan any sweep complete all as specified and as directed by Engineer-in-Charge.
Supply only armature shaft of ceiling fan of any sweep etc complete all as specified and as directed by Engineer-in-Charge.
Supply only rubber reel with clamps, nut bolts washers and split pin of suitable size for ceiling/exhaust fan all as specified and directed.
Supply only fan canopy plastic body suitable for any type/any make/any sweep of ceiling fan all as specified and directed .
Supply only ceiling fan down rod of metal ,15mm dia 450mm long suitable for any type of ceiling fan all as specified and directed.
Supply only metallic blade for ceiling fan 1200 mm sweep including bolt for fixing complete all as directed by Engineer-in-Charge.
Supply only Bracket, legs and rubber bush suitable for existing exhaust fan of any size all as directed by engineer-in-Charge.
Supply only metallic blade (four blade set) for exhaust fan 450/350 mm all as directed by Engineer-in-Charge.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 6 sqmm 1100 volt grade (ISI marked ) drawn through PVC casing & caping with necessary fittings, with one 4 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire, including dismantling and taking down old unserviceable submain wiring complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of casing caping shall be measured and paid as one length.
Material and labour for disconnecting, taking down from roof of the building and refixing the same after repair the heat exchanger of solar water heater with electrical backup of capacity 1000/2000 ltrs per day including striping, flush out the complete system to remove any floating and settled dirt, cleaning of tank etc complete all as specified and directed by the Engineer in Charge.
Supply & fixing in replacement Heating Element of 20KW suitable for electrical backup for solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement Thermostat suitable for 1000/2000 litrs solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement Gate valve of size 20mm for 1000/2000 ltrs solar water heater complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement heating element of Geysers of 2 KW rating required at site including rubber washers complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 25mm bore ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, minimum weight 455gm complete all as specified and directed by Engineer-in-Charge.
Material & labour for disconnecting, taking down and refixing the same after repair the geyser of any cap including striping, cutting the existing copper inner tank after welding, brazing and tightening the hold fast ,nuts, bolts, washer etc complete and including making good to disturbed existing surface with plastering complete all as specified and directed by Engineer-in-Charge. Note :- Spare parts if required to be replaced, shall be measured and paid seperately under srl item no.54 to 58 of BOQ here in after as supply only.
Supply only heating element of Geysers of 1.5 KW rating required at site including rubber washers complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat for the Geyser of 25/50 ltr capacity ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply only base assembly for Geyser of capacity 25/50 litre complete with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut and bolts, washer complete all as specified and directed by Engineer-in-Charge.
Supply only geyser inlet tank of capacity for 25/50 Litres, made out of heavy duty copper body complete all as specified and directed by Engineer-in-Charge.
Supply only PVC heavy duty hot type connecting pieces nylon braided with brass adopters 600 mm/450 mm long and fixing in position suitable for Geyser of 25/50 Litre capacity complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement single pole and neutral metal clad enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 amps ‘C’ curve type 240 V and electrical connection complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of LED decorative post top lantern 40Watt IP65 protection resistant to impact and corrosion, glare free with all necessary acessories required as directed by Engr-in charge. Make CG cat ref No LTPO-40-CDL or equivalent of makes given in Appx 'B' as approved by GE.
Supply & fix in replacement of LED 10W inverted pyramid tripod type led bollard with soft 360 degree light, IP65 protection with all necessary acessories required for fixing as directed by Engr-in charge. Make CG cat ref No LBSL1-10-CDL or equivalent of makes given in Appx 'B' as approved by GE.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 10 Sqmm 2 core complete all as specified by Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in pedestal/coping including necessary weathering and formwork etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting, taking down, servicing, testing complete of Aqua RO machine any capacity from existing location and fixed at new or same location all as per specified and manufactures's instruction after servicing and replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge. Note :- Spare parts if required to be replaced, shall be measured and paid seperately under srl item no.65 to 74 of BOQ here in after as supply only.
Supply only suitable SMPS Adaptor 24 volt DC, 2.5 Amp for convert AC to DC supply complete all as specified and directed by Engineer-in-Charge.
Supply only SLC Solenoid Valve 24V SV complete all as specified and directed by Engineer-in-Charge.
Supply Only RO Booster Pump/Motor 100 GDP Suitable For all type of water purifier complete all as specified and directed by Engineer-in-Charge.
Supply Only High grade White pipe 1/4" for RO water Purifier complete all as specified and directed by Engineer-in-Charge.
Supply Only RO Elbow connector size 1/4" Both side Push suited for all complete all as specified and directed by Engineer-in-Charge.
Supply Only filter membrane 1500 TDS complete all as specified and directed by Engineer-in-Charge.
Supply only PP sediments filter 5 Macron complete all as specified and directed by Engineer-in-Charge.
Supply only carbon block fillter pre filter complete all as specified and directed by Engineer-in-Charge.
Supply only carbon block post filter complete all as specified and directed by Engineer-in-Charge.
Supply only water level sensor for controlling RO machine complete all as specified and directed by Engineer-in-Charge.
Shri Electrical Enterprises
Narendra General Suppliers
TRIVENI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .