NBCC Bhawan
NBCC Bhawan
Construction of 10 Nos. Additional Shops for extension of Commercial Shopping Complex at Akhongre-II Tura, Meghalaya
NBCC/SBG/NER/MEGHALAYA/TENDER/2023/08~EW7453ff40af8f587b526fc042
NBCC/SBG/NER/MEGHALAYA/TENDER/2023/08
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
₹2.2 L
19 Oct 2023
5 Oct 2023
19 Oct 2023
5 Oct 2023
19 Oct 2023
Bill of Quantities
ABSTRACT OF COST
S.NO. DESCRIPTION AMOUNT FOR AMOUNT FOR NON
SCHEDULED SCHEDULED
DSR-2021 for CIVIL
Cost Index of Tura @ 28%
DSR-2022 for E&M
As per CPWD office order no: 158/SE(TAS)/GST/2022/331 Dated:
10.08.2022, an additional factor of 6.33% for increase in GST @ 12 % to
GRAND TOTAL ₹ 2,21,69,522.32
GRAND TOTAL ₹ 2,21,69,522.32
Digitally signed by DAIPAYAN
Name of Work:- Construction of 10 Nos. additional shops for extension of Commercial Shopping Complex at Akhongre-II Tura,
Sl. DSR-2021 Description of Items Unit Rate Quantity Amount
1 2.7 Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m
in width or 10 sqm on plan) ………. disposal of surplus excavated soil as
directed, within a lead of 50 m
2 Treatment of soil under existing floors using chemical emulsion
@ one litre per hole, 300 mm apart including drilling
12 mm diameter holes and plugging with cement mortar 1 :2
(1 cement : 2 Coarse sand) to match the existing floor:
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% Sqm 256.15 153.60 39,344.64
3 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm Cum 6326.05 176.70 11,17,813.04
4 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position & binding all complete above plinth level.
5.22.6 Thermo-Mechanically Treated bars. Kg 89.65 39536.48 35,44,445.43
Centring and shuttering including strutting, propping etc. and removal
5 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 307.95 101.04 31,115.27
6 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth Sqm 669.55 198.00 1,32,570.90
and string courses
7 5.9.3 Suspended Floor, Roof, landing,balconise Sqm 766.55 587.40 4,50,271.47
8 5.9.5 Lintels, beams, plinth beam, girder Sqm 608.35 394.56 2,40,030.58
9 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 804.25 394.56 3,17,324.88
10 5.9.7 Stairs, except spiral-staircase. Sqm 657.75 38.02 25,007.66
11 4.1 Providing and laying in position machine batched and machine mixed
design mix M-20 grade ........... improve workability without impairing
strength and durability as per direction of E-I-C.“
4.1.2 All works upto plinth level. Cum 7783.65 301.37 23,45,758.60
12 6.4 Brick work with F.P.S bricks of class designation 7.5 in superstructure
13 13.4 12mm cement plaster of mix:
14 13.16 6mm cement plaster of mix:
15 13.26 Providing and applying plaster of paris of 2mm thick over plastered Sqm 214.30 2993.22 6,41,447.05
16 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and Sqm 166.85 746.70 1,24,586.90
including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
17 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even Sqm 140.05 597.88 83,733.09
shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under
coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and
18 13.61 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :
13.61.1 Two or more coats on new work. Sqm 131.45 2398.03 3,15,221.04
19 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to
be specified by the manufacturer)
STEEL & FABRICATION WORK
20 10.161 Steel work in builtup tubular(round,square or rectangular hollow Kg 154.9 3313.25 5,13,222.43
tubes etc.) trusses etc. including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete.
10.6 Supplying and fixing rolling shutter of approved make …..... Sqm 3008.80 102.00 3,06,897.60
21 10.28 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm kg 612.25 1165.86 7,13,797.79
aperture on both sides.
WATERPROOFING ON TERRACE
22 22.7.1 Providing and laying integral cement based water proofing incl. Sqm 1522.95 171.6 2,61,338.22
preparation of surface as required for treatment of roof .
23 12.52 Providing and fixing tiled false celing of approved materials of size
595x595mm in true horizantal level, suspended on inter locking matel
gird of hot dipped galvanized steel sections(galvanized @120gms/sqm,
both side inclusive) consisting of main"T" runner with suitably spaced
joints to get required length and of size 24x38mm made from 0.30mm
thick(minimum) sheet, spaced at 1200mm centre to centre and
cross:T" of size 24x25mm made of 0.30mm thick(minimum) sheet
1200mm long spaced between main "T" at 600mm centre to centre to
form a gird of 1200x600mm and secondary cross "T" of length 600mm
and size 24x25mm made of 0.30mm thick(minimum) sheet to be inter
locked at middle of the 1200x600mm panel to form girds of
600x600mm and wall angle of size 24x24x0.3mm and laying false
celling tiles of approved texture in grill including required
cutting,making, opening for service like girlls, light fittings, fixtures,
smoke detectors etc. main tee runner to be suspended from celling
using GI sloted cleats of size 27x37x25x1.6mm fixed to celling with
12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods
with galvanized butterfly level clips of size 85x30x0.8mm spaced at
1200mm centre to centre along Main "T" bottom exposed width of
24mm of all T-sections shall be pre-painted with polyester paint, all
complete for all heights as per specifications, drawings and as directed
by Engineer-in Charge.
12.52.4 12.5mm thick fully Perforated Gypsum Board tile made from Sqm 1247.50 90.00 1,12,275.00
plasterboard having glass fibre conforming to IS:2095 Part I, of size
595x595mm, having perforation of 9.7x9.7mm at 19.4mm c/c with
centre borders of 48mm and the side borders of 30mm, backed with
non woven tissue on the back side, having an NRC(Noise reduction
coefficiect) of 0.79, with 50mm resin bonded glass wool backing.
DISMANTLING AND DISPOSING
24 15.3 Demolishing R.C.C. work manually/ by mechanical means including cum 2928.1 89 2,60,600.90
stacking of steel bars and disposal of unserviceable material within 50
metres lead as per direction of Engineer - in- charge.
25 15.5 Extra for cutting reinforcement bars manually/ by mechanical means sqm. 947.1 341.76 3,23,680.90
in R.C.C. or R.B. work (Payment shall be made on the cross sectional
area of R.C.C. or R.B. work) as per direction of Engineerin- charge.
26 15.7.4 Demolishing brick work manually/ by mechanical means including sqm. 1698.45 33 56,048.85
stacking of serviceable material and disposal of unserviceable material
within 50 metres lead as per direction of Engineer-in-charge.
SUB-TOTAL (CIVIL WORKS-Scheduled Items) 1,53,72,325.39
ELECTRIFICATION
27 1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with
1.5 sq.mm FRLSH IS Approved PVC insulated copper conductor single
core cable in surface / recessed medium class PVC conduit, with
modular switch, modular plate, suitable GI box and earthing the point
with 1.5 sq.mm. FRLSH IS Approved PVC insulated copper conductor
single core cable etc as required.
1.14 Wiring for circuit/ submain wiring along with earth wire with the
following sizes of HFFR IS Approved PVC insulated copper conductor,
single core cable in surface/ recessed medium class PVC conduit as
required.(Make Havelles/KEI/Polycab
33 1.31 Supplying and fittings suitable gI box with modular plates and cover Each 477.00 90.00 42,930.00
SUB-TOTAL (ELECTRICAL WORKS- Scheduled Items) 9,74,050.00
NS FANS & LIGHT FIXTURES
34 NS-1 Fxing, connecting, testing and commissioning of 1200mm sweep Each 18741.86 12.00 2,24,902.32
ceiling fan 5-star rate as per BEE complete with blades, down rod,
shackle insulator, canopy etc. including providing of electronic step
regulator with face plate matching the existing modular switches as
35 NS-2 Supplying, fixing, connecting, testing and commissioning of LED tube Each 897.04 20.00 17,940.80
Light 1 x 20 watt complete with, lockable holders and including
connection etc. as required .
36 NS-3 Supplying, fixing, connecting, testing and commissioning of LED bulb Each 1006.68 30.00 30,200.40
Light 2 x 20 watt complete with, lockable holders and including
connection etc. as required .
SUB-TOTAL (ELECTRICAL WORKS- Non-Scheduled Items) 2,73,043.52
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
NIT.pdf
Tender Document
GCC with six amendments.pdf
Tender Document
Bill of Quantities.pdf
Tender Document
Technical Specifications.pdf
Tender Document
Make List.pdf
Tender Document
Physical Milestones.pdf
Tender Document
Tender Drawings.pdf
Tender Document
Integrity Pact.pdf
Tender Document
Soil Test Report.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .