| Sl No | Description | Qty | Unit | Eastern Commerce L1 | STANDARD ELECTRONICS L2 |
|---|---|---|---|---|---|
| 1.00Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermatically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS1391(part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 HZ, single phase AC supply capable of performing a)cooling b)dehumidifying c)air circulating d)filtering having rated cooling capacity | |||||
| 1.01 | 1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be less than 4500 Kcal/hr or 18000 BTu/hr or 5250 watt) | 3 | Nos | 39,780 ₹1,19,340 Lowest | 40,000 ₹1,20,000 |
| 1.02 | 2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be less than 6000 Kcal/hr or 24000 BTu/hr or 7000 watt). | 16 | Nos | 53,789 ₹8,60,624 Lowest | 63,500 ₹10,16,000 |
| 2.00 | Standard installation, testing and commissioning of 1.5 / 2.0 TR high wall split type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 19 | Nos | 1,700 ₹32,300 | 1,400 ₹26,600 Lowest |
| 3.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 19 | Nos | 900 ₹17,100 | 800 ₹15,200 Lowest |
| 4.00 | Supply, installation of additional length of copper pipe of appropriate size of 5/8" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.5 / 2.0 TR high wall type and 3.65 TR floor mounting vertical Split type ACs. | 120 | Mtrs | 800 ₹96,000 | 300 ₹36,000 Lowest |
| 5.00 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 150 | Mtrs | 120 ₹18,000 Lowest | 130 ₹19,500 |
Tender Value
₹11.5 L
EMD Value
₹22,920
Closing Date
24 Jul 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division
Providing Installation and Commissioning of High Wall Split type Air Conditioning system in different locations Medicine storage room Pathology lab Eye OPD and ward etc of IGM Hospital complex Agartala
2026_CEPWD_74779_1
49_EE_DNIT_MECHDIVN_AGT_202627
Open Tender
Electrical Works
Works
60 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹22,920
28 Aug 2026
17 Jul 2026
24 Jul 2026
17 Jul 2026
24 Jul 2026
17 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermatically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS1391(part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 HZ, single phase AC supply capable of performing a)cooling b)dehumidifying c)air circulating d)filtering having rated cooling capacity | |||||
| 1.01 | 1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be less than 4500 Kcal/hr or 18000 BTu/hr or 5250 watt) | 3 | Nos | - | - |
| 1.02 | 2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be less than 6000 Kcal/hr or 24000 BTu/hr or 7000 watt). | 16 | Nos | - | - |
| 2 | Standard installation, testing and commissioning of 1.5 / 2.0 TR high wall split type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 19 | Nos | - | - |
| 3 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 19 | Nos | - | - |
| 4 | Supply, installation of additional length of copper pipe of appropriate size of 5/8" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.5 / 2.0 TR high wall type and 3.65 TR floor mounting vertical Split type ACs. | 120 | Mtrs | - | - |
| 5 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 150 | Mtrs | - | - |
stage.html
html • 0.02 MB
finance_76119.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
DNIT.pdf
Tender Documents • 2.90 MB
BOQ_76119.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .