Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.5 L+₹47,521 (9.49%)Rejected-AOC III 246 MANIYATTU BUILDING KURUPPAMPADY P O RAYAMANGALAM ERNAKULAM KERALA 683545 INDIA | ERNAKULAM | KERALA | 683545 | L2 | Rejected-AOC L2 |
Tender Value
₹5.3 L
EMD Value
₹13,208
Closing Date
13 Sept 2023, 6:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer,PWD Electrical Subdivision,Chembukavu,Thrissur-20
DEPOSIT-Comprehensive annual maintanance contract for Electrical installation including 200 KVA DG set and AC units in Govt Guest house Ramanilayam for a period of one year
2023_PWD_600212_1
ESDT(ET)76/AEE/23-24
Open Tender
Electrical Works
Item Rate
365 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,165
₹13,208
Yes
17 Jun 2025
5 Sept 2023
14 Sept 2023
5 Sept 2023
13 Sept 2023
5 Sept 2023
Amount
Electrical maintenance
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.10.3.17:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.10.3.24:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )Step Fan regulator - type 2 M
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.14.28.13:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 2 HP submersible motor pumps (DOL)
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.4:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
OD276316/2022-2023:Supply and fixing of 2.25 mfd. Capacitor fan capacitor in the existing Fan
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.14.28.12:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 1.5 HP submersible motor pumps (DOL)
OD276317/2022-2023:Supply,conveyance,erection, installation testing and commissioning of 3 HP open well horizontal type submersible motor pump set having 20-34 m head ,suitable for 440V.50Hz,3phase AC supply(KOS-335+) complete with stadard accessories etc as required (Kirloskar/Equivalent make)
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
90.3.19.4:1200 mm 2X20W LED Lamp with box type fixture
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
OD759/2023-2024:Supply of good grade Company manufactured type Heat exchangeable type coolant suitable for Diesel Engines, including conveyance, loading, and unloading, etc at the site as required
OD760/2023-2024:Supply and installation of electric water heater 15Litre 5 star rated 8kg/cm2 with 10years warranty for the tank and 4 years for heating element and giving connection(V guard Pebble metallica/equivalent)
OD761/2023-2024:Supply and installation of Single Phase DOL starters for 0.25 to 3 HP motor
OD762/2023-2024:Supply, installation testing and commissioning of single phase 1.5 HP open well horizontal type submersible motor pump set at 21-42 m head range ASMSP-1125B TEXMO/equivalent make (ISI marked) delivery size 40 mm having discharge 145/20 lpm using leak proof materials as required and laying in the existing sump including fixing delivery pipe connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary supports on both sides of the motor including giving connection as per the direction at site. [ CRI/Aquatex/KSB /Kirloskar/Texmo ]
OD763/2023-2024:Supplying and fixing key tag with key fob on the existing modular plate & switch box including connections and modular plate etc. as required.2 module 16A ,230v key card switch with key fob
OD789/2023-2024:Supply and refill Engine Oil with buy back arrangement (15W-40)
OD790/2023-2024:supply and replace supper by pass filter for 200KVA DG
OD791/2023-2024:Supply and fixing of SMPS based Battery Charger suitable for 12/24V DC, 0.5 to 10A capacity and giving connection etc as required.
OD792/2023-2024:supply and replace fuel filter for 200 KVA DG
OD793/2023-2024:Supply of good quality company makes Lubrication Oil Filter suitable for Diesel Engine having capacity between 250BHP including conveyance etc as required.
OD794/2023-2024:Annual maintenance Contract of 1no 200 KVA Grievs make DG Set installed at Government guest house ,Ramanilayam,Thrissur, at the site by an authorized company technician including 6 times Emergency breakdown calls, 2 times Preventive Maintenance services (Once in 6 Months or 600 hours, whichever is earlier. Engine oil , Filters and other consumables will be excluded ), Preventive maintenance of the D.G set and AMF panel carried out by 6 times in an year (bi-monthly) which includes the following works 1.Checking, Overall condition/appearance of equipment (controls, leaks, loose wires).2. change all fuel and oil filters in this contract and if required change the belts and the amount will be paid separately.3. Inspect and adjust rack on unit injector or fuel distributor pump according to manufacturer's instructions. Check injector pump and injectors and verify flow rate, pressure, and spray pattern.4. Adjust the governor for proper operating speed if required.5. Flush cooling system and check hoses. Replace hoses if required by COR. Replace coolant by the contractor and hose if required and the payment for that items will be made separately. I6. Brush and clean the coolant heat exchanger, in and out and painted the outer metal cover. 7. Tighten control and power wiring connections. 8. Check the calibration of voltage-sensing relays/devices. 9. Change Lubricating oil. Review the Material Safety Data Sheet (MSDS) for proper disposal of used oil. (the charge for the oil given separately)101. Inspect and clean generator rotor, stator, exciter and battery Charger etc.11. Check the vibration of the Engine.12. Clean voltage regulator, and control panel etc13. Measure and record resistance reading of generator winding with insulation tester (Megger)..14. Inspect safety shutdown devices. This includes simulated faults on low oil pressure cut-off, high water temperature cut-off, over-speed cut-off and failed start.15. Check generator bearings and bearing grease. Lubricate in accordance with manufacturer's instructions.16. Visually check bus bars, bracing, and feeder connections for cleanliness and signs of overheating.17. Perform other work prescribed by the manufacturer and reported Overall Condition Assessment of the DG set.18Run generator set (under load) to check voltage, check frequency, check instrument system and make adjustments.19. check AMF Panel including tighten the control wire , check AMF relay , Contactors , Meters, OV, UV, EF relay, CT ,and ACB etc 20. Clean generator room/cabin and remove all debris.as per the manufactures checklist and make the unit a good working condition.
OD810/2023-2024:Supply and replace of Thermostat for Water heater
OD811/2023-2024:supply and replace the Lube oil filter for 200KVA DG
OD815/2023-2024:Supply and renewing Thermostat for AC unit in place of the existing faulty ones and giving connections etc as required
OD816/2023-2024:Supply and replace of 24V 105 AH battery for generator(exide or equivalent make)
OD1497/2023-2024:Annual Maintenance and servicing of 1/2/3 TR, 240/415V Air Conditioner Units (Vertical and Wall/Floor Mounting type Split AC unit such as cleaning and servicing of indoor and outdoor unit in yearly as per the condition attached in annexure-1( In normally One water servicing in an year with using chemical material water pump etc. and Three Air servicing in an year with using cleaning material and pressure air pump etc. also including attending minor petty repairs ,fuse call attending, rectifying defects if any- excluding the material) during the contract period and maintaining of indoor and outdoor unit as a proper working condition though out an year. (Ordinary places - Office /Clinic/ Pharmacy/Conference cum Training hall etc)Rate for 4 servicing of 1 no: AC
OD1591/2023-2024:Charges for filling sufficient quantity of R32 gas for existing air conditioner unit including leak testing, rectifying the defects leak arresting etc as required-
OD1592/2023-2024:Supply and renewing Outdoor Fan Motor for Split AC unit-1/1.5/2TR in place of the existing faulty ones and giving connections etc as required.
OD3662/2023-2024:Supply and renewing Fan Motor Capacitor for AC unit -2.5/3/5 MFD(Indoor motor) in place of the existing faulty ones and giving connections etc as required.
OD3663/2023-2024:Supply and renewal of indoor PCB suitable for 1.5/2/3 TR split AC unit in place of damaged one
OD3664/2023-2024:Supply and renewing Running Capacitor 40 MFD for AC unit - 1.5 TR in place of the existing faulty ones and giving connections etc as required.
OD3665/2023-2024:Supply and renewing Indoor Fan Motor Blower type for Split AC for AC unit-1.5/2/3 TR in place of the existing faulty ones and giving connections etc as required.
OD3683/2023-2024:Supply and renewing Fan Motor Leaf (Plastic) for1/1.5/2 /3TR AC unit in place of the existing faulty ones and giving connections etc as required.
OD3684/2023-2024:Supply and renewing Fan Motor Capacitor for )1/1.5/2/3 TR AC unit -10 MFD (Out door motor in place of the existing faulty ones and giving connections etc as required.
OD3685/2023-2024:Supply conveyance installation testing and commissioning of 4KVA Voltage Stabilizer (V-Guard) with input voltage 170 to 270 V output voltage range of 210 to 230 V with over load protection (cut off) time delay, indicators, etc as required
OD3686/2023-2024:Supply conveyance installation testing and commissioning of 5 KVA Voltage Stabilizer (V-Guard or equivalent) with input voltage 170 to 270 V output voltage range of 210 to 230 V with over load protection (cut off) time delay, indicators, etc as required
candelaengineering corporation
Bidder Name
M P SUBASH
candelaengineering corporation
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_891478.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .