Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 203 B CHAHBAI BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | ₹1.1 Cr | L1 | Accepted-AOC As the overall rates are reasonable and lowest. |
| 2 | L2₹1.2 Cr+₹11.0 L (9.75%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹1.2 Cr+₹11.0 L (9.75%) | L2 | Rejected-Finance Over all rates are higher than L1. |
| 3 | L3₹1.3 Cr+₹20.7 L (18.4%)Rejected-Finance | ₹1.3 Cr+₹20.7 L (18.4%) | L3 | Rejected-Finance Over all rates are higher than L1. |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
6 Sept 2021, 6:00 pmClosed
CWE (AF) Bareilly
CWE (AF) Bareilly PIN-243002
ADDITION/ ALTERATION TO HANGAR AND ASSOCIATED BUILDING AT AF STATION BAREILLY
2021_MES_463965_1
Addtion/Altn to hangar and other bldg at BLY
Open Tender
Civil Works
Item Rate
180 days
Bareilly
As per NIT
8 documents required · 8 mandatory
₹1,000
Yes
₹1.9 L
Yes
24 Sept 2021
3 Aug 2021
8 Sept 2021
3 Aug 2021
6 Sept 2021
24 Aug 2021
3 Aug 2021 - 18 Aug 2021
Amount
SCHEDULE A PART I (BUILDING)
Construction of 01 X Building block for fuel consumption trolley (03X Bay) complete all as per specified and as shown on drawing.
Sch A Part II( INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Sch ‘A’ Part- II .
Sch A Part III (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part- III.
SCHEDULE 'A' PART IV (MISCELLANEOUS ITEMS of B/R AND E/M ITEMS - TO BE QUOTED BY THE CONTRACTOR)
Demolition of unreinforced cement concrete (as in Hardstanding) in ground floors and pavings exc 15cm thickness (below or above ground level) using diamond cutter and mechanical breaking tools including removing demolished concrete/debries to a distance exceeding 1.5km and n.exc.5km and deposited complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as spd and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing demolished concrete/debries to a distance exceeding 1.5km and n.exc.5km and deposited complete all as specified and directed.
M & L for Non - skid coloured joint free Ceramic tiles 7 to 8 mm thick (600mm X 600mm ) area of each tile exceeding 0.18 sqm but not exceeding 0.36sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over bed or bedding layer of 15mm thick in CM 1:4 over and incl 25mm thick PCC 1:2:4 type B0 (using 12.50mm graded crushed stone aggregate) finished even and rough to receive topping layercomplete all as specified and directed.
M & L for Non - skid coloured joint free Ceramic tiles 7 to 8 mm thick (600mm X 600mm ) area of each tile exceeding 0.18 sqm but not exceeding 0.36sqm, in vertical surfaces such as in skirting,dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plastering in CM 1:4 complete all as specified and directed.
M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover bed or bedding layer of 15mm thick of CM 1:4 over and including 25mm thick PCC 1:2:4 type B0 finished even and rough to receive topping layer complete all as specified and directed.
M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm thick plastering in CM 1:4 complete all as specified and directed.
M&L for 150mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate as in sub base of floor finished even and rough to receive topping layer complete all as specified and directed.
M&L for glass dividing strips 3mm thick x 48mm wide inserted in position, comform to design in flooring complete all as specified and directed.
M&L for 50mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate as in topping layer of floor finished even and fair (without using extra cement) complete all as specified and directed.
M&L for 75mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate as in topping layer of floor finished even and fair (without using extra cement) complete all as specified and directed.
M&L for 100 mm thick Cement concrete Type B1, 1:2:4 (using 20 mm aggregate) in floors casted in panels incl broom fishing the top surfaces of concrete complete all as specified and directed.
M&L for Epoxy Polyurethane flooring system consisting of the following provisions complete all as specified and directed :- (a) Removing existing damaged PU flooring, paint, oil grease strain, mortars etc.by shot blasting, grinding etc (b) Cleaning the surface as specified here-in-after. (c) Shot blast/diamond grind the entire floor to remove foreign material/carbonate materials if required. (d) Filling the dents and cracks with suitable epoxy putty or mortar followed by application of epoxy primer, if required (v) making existing surface free from dust including making good existing expansion/construction/dummy joints with out disturbing their position. (e) Applying 2 coats of primer "Apcoflor HFP 120" Make- Asian paint of 60 micron each. (f) Applying 2mm thick Apcofloor LSC 3 screed of Asian Paints (g) Aplying 2mm thick (minimum) self levelling finish coat of " Apcoflor EPU SL-2, Make- Asian paints complete all as specified and manufactures instructions. Note :- (i) Entire treatement to be carried out by official applicator of approved product. (ii) Work to be executed in occupied hanger and the work in restricted area.
M&L for Preparation of old plastered surface of wall and applying one coat of oil bound distemper complete all as specified and as directed.
Taking down chowkhat or frames ( without taking off shutters from the frame) area exc 1.5 sqm but n exc 4 sqm each complete all as specified and directed.
Refixing Chowkhats or frames ( without taking off shutters from the frame) area exc 1.5 sqm but n exc 4 sqm each in the same opening after changing direction of opening incl provision of PCC 1:2:4, type B0 in bed blocks for securing hold fasts and making good the surfaces by cm 1:4 plastering and applying surface finishes to match with the existing complete all as specified and directed.
S&F Aluminium (extruded section) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg, ISI marked (IS-3564), heavy duty and fixed complete all as specified and directed.
Excavating in trenches (manual excavation) n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc or for shafts,wells,cess pits, main hole, pier holes etc n exc 10 Sqn on plan and n exc 1.5m in depth and getting out of soft/loose soil and all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point and complete all as specified and directed.
M & L for PCC 1:4:8 Type D2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L Flyash Brick work with old sized bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 all as specified and directed.
M&L for providing cement concrete type B0 1:2:4 (12.5 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps;seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
M&L cement plastering 15mm thick in cm 1:4 on fair faces of brickwall or concrete surfaces finished even and smooth withoout using extra cement complete all as specified and directed.
M&L for 10mm thick plastering in CM 1:6 on other than fair faces of brick wall or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of lime white wash over a coat of primer complete all as specified & directed.
S&F MS Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified in SSR Part -I (2009) and as directed.
M&L Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion with cement concrete 1:2:4 Type B-0 and Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc half brick thick wall but not exc One brick thick wall including plastering the disturbed surfaces of soffits and ceiling with CM 1:4 and applying surface finishes matching with the existing complete all as specified and directed.
S&F Framed work such as grills gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M & L for preperation of new steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer complete all as specified and directed.
Cutting chases, pinning in Brick work making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases, and making good, cutting not exc 10 cm girth
M&L Reinforced cement concrete 1:1.5:3, type A-1 (using 20mm graded stone crushed aggregate ) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping).
S & F powder coated aluminium frame for doors, windows, ventilators, Partition with one or more rebates including joining cleat for fixing etc with powder coated complete all as specified.
M&L for Preparation of old plastered surfaces on ceilling and applying one coat of oil bound distemper complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails including AL seections complete all as spd and directed.
M & L for providing plain Cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete etc complete all as specified and directed.
M&L for preperation of new surfaces of ceilings, and three coats of white wash over 5mm thik cement plaster of cm 1:4 on ceillings and all as specified and directed.
Preparation of newly plastered surfaces of wall by priming of chalk whitening (white putty) and applying two coats of oil bound distemper complete all as specified and as directed.
S&F steel work in tubular truses (RHS) incl special shaped washers wind tie ,bolts ,plates etc complete including purlins and post using ERW or induction butt welded tubes conforming to IS 4923-2017 grade YST 310. Complete all as speciifed and directed.
M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
S&F Pre-painted Trapezoidal profile galvalume or Zincalume profiled coloured coated steel sheet 0.60 mm total thickness (with coating and painting) of approved colour as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by GE. (ii) Sheeting shall be fixed of any height. Make : Tata Blue Scope/Jindal
S&F Pre-painted Trapezoidal profile galvalume or Zincalume profiled coloured coated steel sheet 0.60 mm total thickness (with coating and painting) of approved colour as in roof ridge factory made, match with roof sheetings, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by GE. (ii) Sheeting shall be fixed of any height. Make : Tata Blue Scope/Jindal
M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface and complete all as spd and directed.
M&L for 75mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate as in sub base of floor finished even and rough to receive topping layer complete all as specified and directed.
M & L for Glazed ceramic colour tiles 7 mm thick in dado/skirting (vertical surface) of size 450X 350X 7mm and jointed in neat cement slurry and pointed in white or colour cement over 10mm thick cement plaster in cm 1:4 to match complete all as specified and as directed.
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and as specified and directed.
M&L TMT steel bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finishing as specified and directed.
S&F 20mm thick granite stone slab machine cut,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 20 mm thick screed bed or bedding layer of cement mortar (1:4) for laying floor finishes, chamfering/bullnosing of edges and grinding and polishing complete all as specified and as directed.
M&L for Brickwork with Fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cm 1:4 and complete all as specified and directed.
M&L for 150 mm thick (compacted thickness) Hardcore of broken stone or boulders of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 7.5 cm thick each layer, watered and rolled with 8 to 12 ton power roller to a true surface to required gradient and camber complete all as specified and directed.
M&L for 250 mm thick (compacted thickness) PCC, M-25 design mix (using 20mm graded crushed stone aggregate) casted in panels as in hardstanding incl all necessary formwok complete all as specified & directed.
M&L for Finishing the surface concrete by brooming while the concrete is still green complete all as specified and directed.
M&L for forming 25mm wide expansion joint to full depth of pavemnt concrete slab as per shape and section shown on drawing (depth of slab 250mm) and primed and filled with compressible filler board(silflex Dura board HD 100 of Supreme make or equivalent as approved GE) and providing a back up rod/debonding strip and top 10 mm primed and sealed with and using polyurethane based sealing compound (polyurethane joint sealant) with suitable primer as per manufacturer's recommendation complete all as shown on drawing and specified and directed (including cutting edge of existing pavement for forming expansion joint between existing and new slab if required) complete all as specified and directed. Note:- Expansion joints shall be provided at spacing not exceeding 36m, as direced by GE. The expansion joints shall be cut to full depth and shall be formed as described herein above locations directed by GE, if the slabs are casted for longer lengths. The cost of full depth cutting as required for forming expansion Joints at such locations shall also be deemed included in the contractor's quoted rate for above item.
M&L for forming contraction/dummy joint 8mm wide and 17/18mm deep primed and providing a 10mm dia polysterene backup rod/debonding strip and 13mm primed sealed with and using polyurethane based sealing compound (polyurathane joint sealant) with suitable primer as per manufacturer's recommendations including 3mm wide saw cut up to 85mm depth complete all as shown on drawing and specified and as directed. Note:- Joint filling operation shall be carried out mechanically by the rep of manufacturer of sealant.
M&L for forming construction joint 10mm wide and 17/18mm deep primed and providing a 10mm dia polysterene backup rod/debonding strip and top 13mm primed sealed with and using polyurethane based sealing compound (polyurathane joint sealant) with suitable primer as per manufacturer's recommendations including 3mm wide saw cut up to 85mm depth complete all as shown on drawing and specified and as directed. Note:- Joint filling operation shall be carried out mechanically by the rep of manufacturer of sealant.
S&F for Aluminium composite panel 5mm thick of approved color fixed to frame work or doors etc complete all as spd and directed.
S&F for rubber gasket of required size & shape for fixing glass panes and alco panels etc complete all as specified and directed.
S&F for Aluminium powder coated chamfered beading to doors or partitions etc complete all as specified and directed.
S&F Sheet glass tinted /reflective 5.5 mm thick (of any tint) fixed with beadings in square n,exc 0.50 sqm in each pane complete all as specified and directed.
S&F Aluminium section powder coated of colour as approved Sliding doors with frame and shutters partly with 5.5 mm thick reflective glass and partly closed with 5 mm thick aluminium composite panel (alco panel) fixed with aluminium chamfered clip section no 4407 of aluminium door sections as under. (a) Frame 100x40x2mm section No-2420 (b) Shutter style 85x44.45x1.7mm thick section 4546 (i) Top rail 14.30x44.45x1.7mm thick section 4553 (ii) Middle rail 83.50x44.45x1.7mm thick section 4565 (iii) Bottom rail 114.30x44.45x1.7mm thick section 4529 (iv) glazing clip powder coated 0.7mm thick section no 4407 (v) Handle stainless steel 300mm long as approved (vi) Tower bolt powder coated 9.90 mm dia & 200mm long section No 4002 (vii) Mortice lock 100mm 7 lever all as directed of Godrej make (viii) Hold fast aluminium 100 mm long (ix) Rubber gasket white PVC(x) Namda rope to be fixed in the styles's groove for proper air tightness complete all as specified and directed.
M & L for 17/18 mm medium density fibre board exterior grade, fixed to timber frame work with screws, both sides laminated with one side decorative choice laminated and other side balancing white lamination, fixed to timber frame work complete all as specified and directed.
S & F mild steel bright finished telescopic ball bearing drawer channel (silver), of size 18 " complete all as specified and directed. Make :- Hetttich/Ozone/Flyrale or ISI marked as approved by GE.
S&F for Hydraulic hinges (L-Bihari) 0"/ 8"/16" degree MS bright polished complete all as specified and directed. Make Hettich/Ozone/Flyrale of ISI marked as approved by GE.
S & F for stainless steel 100 mm long handles, fancy type for cabinet complete all as specified and directed.
S&F for stainless steel letters (of size 200 mm height) using cleat, L keys including all fixing arrangements with exterior grade polished (SS-304) complete all as approved by GE.
S&F for rolled section as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc grade Fe-290, (Gd-E-365) complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
M&L for 100mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate as in sub base of floor finished even and rough to receive topping layer complete all as specified and directed.
M & L for 100 mm thick cement concrete type B1 1;2;4 using (20mm graded aggregate) finishing the surfce even and smooth without using extra cement casted in panels and complete all as specified and directed.
S&F Cabinet with provision of drawers including channels, brass handle, locks, using vaneered prelam boards of thickness 18/19mm including all assessories for proper finish complete all as specified and directed.
S&F linear 60mm panel based workstation 1200x600x1200 (60mm thick panel based alumunium partition system is considered having pvc caps as per methodex partition stastem) break-up of single seat/single cluster (a) 60mm thick front panel with double raceway size-1200x1200mm----01 nos (b) 60mm thick side panel with double raceway size-600x1200mm-----02 nos (c) 25mm thick plpb worktop- 600x1200mm--- 01 nos (d) 3 drawer mobile pedestal in plpb having recessed handles 400x450x680---- 01 nos. (e) metal keyboard tray--- 01 nos (f) cpu trolly--- 01nos. (g) over head cabinets in prelam board 18mm [600(l) x 380(d) x 450(h) with swing shutters]-- 01 No
S&F linear 60mm panel based workstation 1200x600x1200 (60mm thick panel based alumunium partition system is considered having pvc caps as per methodex partition stastem) break-up of cluster of two (a) 60mm thick front panel with double raceway size-1200x1200mm----02 nos (b) 60mm thick side panel with double raceway size-600x1200mm-----03 nos (c) 25mm thick plpb worktop- 600x1200mm----- 02 nos (d) 3 drawer mobile pedestal in plpb having recessed handles 400x450x680----- 02 nos. (e) metal keyboard tray----- 02 nos (f) cpu trolly----- 02nos. (g) over head cabinets in prelam board 18mm [600(l) x 380(d) x 450(h) with swing shutters]----- 02 nos
S&F linear 60mm panel based workstation 1200x600x1200 (60mm thick panel based alumunium partition system is considered having pvc caps as per methodex partition stastem) break-up of cluster of five (a) 60mm thick front panel with double raceway size-1200x1200mm----05 nos (b) 60mm thick side panel with double raceway size-600x1200mm----06 nos (c) 25mm thick plpb worktop- 600x1200mm---- 05 nos (d) 3 drawer mobile pedestal in plpb having recessed handles 400x450x680----- 05 nos. (e) metal keyboard tray----- 05 nos (f) CPU trolly----- 05 nos. (g) over head cabinets in prelam board 18mm [600(l) x 380(d) x 450(h) with swing shutters]----- 05 Nos
Taking down chaukhats or frames (without taking off shutters from the frame) area not exc 1.5 sqm and making good the disturbed jambs,cill and soffits of opening by providing brickwork in CM 1:4,plastering in CM 1:4 & applying two coats of oil bound distemper over a coat of wall putty to match with the existing surfaces complete all as specified and directed.
S & F aluminium powder coated sliding windows with shutter and frame made with frame of aluminium section two track which consists of following: (a) frame 61.85 x 31.75 x 1.2mm not less than @ 0.659 Kg weight (b) Shutters 40x18x1.5mm (c) Grill Aluminium powder coated grill weighing not less than weight 1.0Kg/sqm) (d) Glass 4.8/5.5 mm thick tinted/reflective with rubber gasket and suitable clip (e) Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm Make : Jindal/ Hindalco/Indalco
S & F aluminium powder coated sliding windows with shutter and frame made with frame of aluminium section three track which consists of following: (a) frame 61.85 x 31.75 x 1.2mm not less than @ 0.659 Kg weight (b) Shutters 40x18x1.5mm (c) Grill Aluminium powder coated grill weighing not less than weight 1.0Kg/sqm) (d) Glass 4.8/5.5 mm thick tinted/reflective with rubber gasket and suitable clip (e) Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm Make : Jindal/ Hindalco/Indalco
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to RCC roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed.
S & F for POP designer cornices of approved shape and design at wall and ceiling joints, of cross sectional area n exc 80 Sqcm and girth n exc 200 mm complete all as specified and directed.
M&L for preparation of newly surfaces of ceilling and applying a coat of chalk whitening (white putty) and applying two coats of oil bound distemper complete all as specified and as directed.
M & L for 15 mm thick Fine fissured board of size 600X600mm mineral fibre accoustic false ceiling tiles CAT Part No 1833 M of ARMSTRONG false ceiling system at any height with back of the duly sanded and finished with a coat of protective paint and front duly finished and fixed to true lock PVC dle KL-24 suspension system (hot dipped galvanised steel section) of exposed T section grid with exposed face powder coated white colour. The suspension system consisting of parameter wall angle of size (24x24) mm of thickness 0.45 mm of GS sheet to secure on walls / partition face with the help of raw plug @ 450 mm c/c universal main runner of T shape section with single rotary stitchng of size (38x24) mm made from 0.35 GS sheet of length 3.6 mtr to be spaced at 1200 mm c/c CRO runner T shape with double rotary stitching of size (30 x 24) mm of length 1200 mm made from 0.25 mm thick GS sheet spaced @ 600 mm c/c (1200 x 600) mm of size modules internmediate T shaped cross runner of size (25 x 24) mm of length 600 mm made of 0.25 mm thick GS sheet to form (600 x 600) size of module incl suspension of the ceiling frame from the RCC roof/structural member with soffit angle cleat and dash faseners and required member of GI suspender of 4 mm thick GI wire and level adjuster all complete and including cost of making opening for light fitting diffusers cut out etc to the required line and shape as per manufacturer recommendations and architectural drg complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame as per specification and drawing complete all as specified and as directed.
S&F 5mm thick printed PVC sheet in strips and channel feathered at edges for fixing on solid PVC wall lining all as per specification and drawing complete all as specified and as directed.
S&F Solid PVC wall lining consist of 5mm thick wood grain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and as directed. Note: PVC fillets and PVC strips shall be measured seperately.
Supply installation testing and commissioning and fixing of desert cooler elctric driven fresh virgin plastic body and is fitted with 100 % copper motor and Aluminium casting blade. The front-back grill, hardware and screws are of stainless steel. The Cooling capacity is 2400 sft heavy duty of water tank having capacity minimum 120 ltrs along with 04 nos wheel complete with all internal PVC water pipe connection lead, fan nominal air flow 10600 CFM, sound level (db) 68 . Fan motor should be of heavy duty with fan motor blade size 762 mm , work on single phase 230 volts 50 Hz AC supply and suitable for cooling to floor area of 2500 sft and body size Height/Width/ Depth is 1650 mm/1110mm/600mm complete all as specified and directed. Make:- KAILASH 2400i of Ram Coolers/ Symphony
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 Volts grade (ZHFR) Zero Halogen Flame Retardant Smoke Free Non-Toxic Non-Corrosive Electric Cable with multi stranded copper conductor of size 1.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia ERW stove enameled surface type including all flame proof conduit fittings and accessories such as tees, junction boxes, bends, duly tested by CMRI Dhanbad suitable for one light/ fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire PVC insulated unsheathed 1100 V grade (ZHFR) Zero Halogen Flame Retardant Smoke Free Non-Toxic Non-Corrosive Electric Cable with stranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete all as specified and directed by Engineer-in-Charge.
(a) One light/Fan point controlled by one way switch.
All as per item No 96 here-in-before but with copper conductor 4.0 sqmm for One 3/5 pin socket outlet, 16/25 Amps on independent board all as specified and directed.
S&F flameproof weather proof for installation in hazardous area as per IS-2148 LED tube light fitting epoxy powder coated with provision of cable glands duly tested and certified by CIMFR Dhanbad, recommended for gas/vapour group of IIA&IIIB , Zone 1 & 2 IP 65 protection suitable for and including 1X 40 watt 4 ft LED tube light made out of cast aluminium alloy LM-6 enclosure with clear heat resistant borocilicate glass tubing spring loaded non sparking bipin lamp holder built in control gear fitted with copper wound ballast condensor starter all accessories prewired including 02 Nos M-20 cable entries mounted on wall/Coloumn steel structure complete all as specified and directed. Make:- Sudhir switchgear, or equivalent to Flexpro/ Crompton Greaves.
S&F Flame Proof Exhaust Fan 305mm sweep 1440 RPM, 230 Volts, single phase, 50 Hz, AC supply totally enclosed heavy duty motor of Cap 0.33 HP with die cast aluminium rotor mounted on two ball bearing complete with louvers including cutting chases for fixing fan, connecting electrically using 3 Core 0.5 Sqmm PVC insulated FRLS flexible copper conductor cable overall sheathed all as required at site with connected accessories etc confirming to Cat Pat No EF/140 of make Sudhir complete all as specified and as directed. Note :- Flexible copper conductor cable shall be covered with flame proof flexible pipe.
S&F Flame Proof Wall Mounting Fan 415mm sweep, 1440 RPM for speed and oscillation motor, complete fixing arrangement on wall and connecting electrically using 3 Core 2.5 Sqmm PVC insulated FRLS flexible copper conductor cable overall un-sheathed all as required at site with connected accessories etc confirming to Cat Pat No WMF/140 of Sudhir complete all as specified and as directed.Make : Sudhir/Shyam/Baliga
S & F Flame proof weather proof direct entry type rotary switch single pole ON and OFF rotary motion switch in cast aluminium alloy lm-6 enclosure epoxy powder coated single pole 230volt 10 Amp AC ON/OFF switch operated externally by knob having two nos of M-20 cable entries earthing terminal suitable for mounting on wall/steel structure etc duly tested and certified by CMRI Dhanbad complete all as specified and directed. Make : Flexpro/M/S Sudhir/Baliga/Shyam
S & F Wall/surface mounted type LED light fitting batten type complete with LED lamp 1x 20/22 watt (4 ft), extruded aluminium complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable. Make Philips Cat No BN 021C LED 20S PSU CW GR S2 or Wipro, Osram
S&F of 1100 Volt grade heavy duty 04 single core 2.5Sqmm size, PVC insulated ( FRLS) copper multi stranded conductor cable as in sub main wiring deawn in to and including heavy duty PVC conduit size 25 mm dia including its all accessories& fittings , fixed concealed with and including chase cutting and making good the same as per existing specifications along with 2.5 Sq mm size multi-stranded copper conductor PVC insulated (FRLS) (green colour) cables as earth wire connected to main wring system complete all as specified and directed. Note: Two single core cable along with one earth wire and PVC conduit shall be measured as one unit length. complete all as specified and directed.
S&F suspended/Surface type Highway luminaire 110 Watt, Environment friendly, energy saving long life corrosion resistant vertical surface mounting pressure die cast aluminium housing and control gear with high power LED as light as light source with hanging/fixed including all mounting accessries for fixing with truss of hanger /MT garages etc and complete with prewired with flexible three core 1.5 sqmm size stranded copper conductor cable from light fitting to ceilng rose complete all as specified and directed. Make:- Crompton greaves cat part - LHB11-110-CDL/60 OR equivalent to Philips/Wipro
Supply and fix factory made V TPN DBs-DPX-160 MCCB DB's, IP-43 protection-IK09 with metal door with 200 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB and incomer and included with SP/TP MCB's as outgoing 8 way etc complete all as specified and directed .Make:- Legrand, Scheinder, ABB
Supply and fixing 4 pole MCCBs 125 Amps capacity, 415 volts with repturing capacity 25KA,Make : Legrand /Siemens/Schneider
Supply and fix MCB single pole and neutral, 240 volts, 32 to 40 amps breaking capacity 10KA, ‘C’ Series. etc , complete all as specified and directed. Make : Legrand /Siemens/Schneider
Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series all as specified and directed. Make : Legrand /Siemens/Schneider
Supply and fix MCB single pole 240 volts,40-63amps, 50HZ, 10 KA. , ‘C’ series all as specified and directed. Make : Legrand /Siemens/Schneider
S&F of 1100 Volt grade heavy duty two single core 6.00 Sqmm size, PVC insulated ( FRLS) copper multi stranded conductor cable as in sub main wiring drawn in to and including heavy duty PVC conduit size 25 mm dia including its all accessories& fittings , fixed concealed with and including chase cutting and making good the same as per existing specifications along with 6.00 Sq mm size multi-stranded copper conductor PVC insulated (FRLS) (green colour) cables as earth wire connected to main wring system complete all as specified and directed.Note: Two single core cable along with one earth wire and PVC conduit shall be measured as one unit length. Make of cable : Finolex/Havells/Plaza
.Supply and fix of sheet metal enclosure with socket plug top and MCB single poleneutral encloser with a two pin and earth plug and socket complete with one no MCB single pole 20 Amp capacity , 240 volts complete all as directed .Make :- Legrand/ Siemens/ Schneider
Supply and fixing 4 pole MCCBs 63 Amps capacity, 415 volts with repturing capacity 25KA, Make :- Legrand/ Siemens/ Schneider
S&F of 1100 Volt grade heavy duty 04single core 10.0Sqmm size, PVC insulated ( FRLS) copper multi stranded conductor cable as in sub main wiring drawn in to and including heavy duty PVC conduit not less than size 32mm dia including its all accessories& fittings , fixed concealed with existing specifications along with 10.0 Sq mm size multi-stranded copper conductor PVC insulated (FRLS) (green colour) cables as earth wire connected to main wring system complete all as specified and directed. Make of cable : Finolex/Havells/Plaza
S&F of 1100 Volt grade heavy duty 04single core 4 Sqmm size, PVC insulated ( FRLS) copper multi stranded conductor cable as in sub main wiring and including heavy duty PVC conduit not less than size 25mm dia including its all accessories& fittings , fixed concealed with existing specifications along with 4.0 Sq mm size multi-stranded copper conductor PVC insulated (FRLS) (green colour) cables as earth wire connected to main wring system complete all as specified and directed. Make of cable : Finolex/Havells/Plaza
S&F Heavy duty (Fully Metal construction) Air Circulator fan 750mm sweep,1440 rpm, 4 speed controlles, with ragulator single phase, 230 volts, AC, 50 Hz with spiral guard design ensures high air thrust , high torque gear box with safty clutch, broad blade profile for low noise, resettable thermal overloaded protector oscillating mechanism and making electric connection using three core flexible twisted copper conductor of proper size fixed on wall complete all as specified and directed. Make:- Almonard, Khaitan, Usha.
Supply and fixing LED street light fitting 70 watt, IP 65 protection made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics ,roadway luminaire with high power LED as light source 1X70 watt, LED , complete with all accessories internally prewired complete and including connecting with 3core x1.0sqmm copper cable from junction box to luminaries terminal block complete all as specified and directed. Note:- Cost of Light grade GI pipe 40mm bore as required and MS clamp(2 pairs), nuts,bolts,washers, etc deemed to be included in the quoted rates. Make:- Wipro/Philips/OSRAM
Supply, install, testing and commissioning hi wall split units indoor/outdoor copper coil complete with cordless remote control unit, electric driven single phase of capacity 2.00 TR, BEE 5 star rating complete all as specified and directed. Make- Bluestar Model No. ICS24DBTU or equivalent to Carrier /Voltas. Note- Power cable between indoor and outdoor unit,refrigerent tubing, outdoor stand and drain pipe shall be deemed to be included in quoted rate of this item.
Supply and installation of flame proof split type air conditioner electric driven (single phase) 230 volts supply CFC free with remote control unit duly tested cerified from CIMFR Dhanbad for use in explosive building of capacity 1.5 ton BEE 5 star rating complete all as specified and directed. Note :- Power cable between indoor and outdoor unit, refrigerant, tubing out door stand and drain pipe shall be deemed to be included in quoted rate of this item. Make:- M/S Sudhir, M/S Shyam switchgear pvt ltd Mumbai.
Supply, installation , commissioning and testing of dehumidifier unit, main body made of metallic sheet duly powder coated , comprising built -in compressor of suitable capacity , special purpose fan motor high saving efficient system of minimum capacity of 140 liters per day , dehumidifying capacity of minimum 5.85 Kg per hrs, minimum Air flow of 1500 Cum per hrs, Minimum humidity setting of RH 30% to 95% in working temp of 5 degree centigrade to 38 degree centigrade electric operated 220-240 volts 50 Hz having minimum power consumption of 2000 Watt rotary compressor based type with maximum controlling of noise level of 52 dB using CFC free refrigerant R-407c or R-410A, drain pipe arrangement towards outside internally fixture to remove the water outside the dehumidifying room, multiple functional wheels, automatic defuser system, delay timer for compressor complete in all respect including unplasticised PVC pipes of pressure rating 10 Kg/cm2 fixed complete to walls, ceilings or in floors etc, size 25 mm dia as reqd at site and as directed by Engr-in-Charge complete all as specified and directed. MAKE Model No AMDH1400 of advance international or Mitsubishi, Dewteq .
yash enterprises
M/s DHARAM VIR GHAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .