Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.7 LAccepted-AOC 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹20.9 L+₹419 (0.02%)Rejected-Finance | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹21.2 L+₹35,352 (1.69%)Rejected-Finance H NO 74 TILIYAPUR CB GANJ BAREILLY UP 243502 | BAREILLY | BAREILLY | UTTAR PRADESH | 243502 | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹22.7 L+₹1.8 L (8.74%)Rejected-Finance 37 B MODEL TOWN NEAR HARI MANDIR BAREILLY UP 243001 | BAREILLY | UTTAR PRADESH | 243001 | L-4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L-5₹23.1 L+₹2.2 L (10.6%)Rejected-Finance H NO 786 ANAND VIHAR COLONY PILIBHIT BYPASS BAREILLY UP PIN 243005 | BAREILLY | UTTAR PRADESH | 243005 | L-5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹58,400
Closing Date
1 Feb 2021, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
PROVISION OF RAISED CONCRETE PLATFORM WITH SHED FOR CERTAIN GUARD POSTS, SPECIAL REPAIR TO COOK HOUSE AND DINNING HALL OF DSC MESS AND PROVISION OF CERTAIN B/R REVENUE AND MINOR WORKS AT AF STATION, BAREILLY.
2021_MES_408998_1
8571 / E8
Open Tender
Civil Works
Item Rate
180 days
Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹58,400
Yes
19 Feb 2021
2 Jan 2021
3 Feb 2021
2 Jan 2021
1 Feb 2021
19 Jan 2021
Amount
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for providing 50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor, finishing top surface even and smooth with using extra cement complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparing old decorated wall surfaces and applying one coat of cement base paint complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slope of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
Taking down door or window shutter of any description exc. 1.00 Sqm but not exc. 2.00 Sqm each complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required exc. half brick but not exc. one brick thick wall complete all as specified and directed.
S & F of 1.25 mm thick pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
S & F of 30 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters for window or ventilator, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (b) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of 12 mm thick veneered particle board medium density, wood particle board with commercial face veneers and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed.
S & F of 125 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
S & F of 300 mm long mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 75 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 50 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of old painted wooden surfaces exc. 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster consisting in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
M & L for complete removal of existing treatment from wall surfaces and applying two coats of distemper oil emulsion over a coat of primer including preparation of surfaces complete all as specified and directed.
M & L for preparation of old decorated surface of ceiling and applying one coat of white wash complete all as specified and directed.
S & F in repairs 15 mm bore bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 1 mm thick stainless steel sink without drainage board Kitchen or laboratory type with plug washer and waste including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size of sink 495 mm X 420 mm and bowl size 410 mm X 330 mm X 160 mm complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F of galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S & F of 0.80 mm thick 304L grade polished, No. 1 poly coated stainless steel sheet as in wall cladding, gate covering and the like including necessary steel welding, molding, overlapping at joints minimum 10 mm, hole punching as required and other required works, fixed with suitable size stainless steel screws and duly welded as per site requirement complete all as specified and directed. MAKE- Jindal, Navbharat, SSL, Suncity.
S & F of rolled mild steel sections as in framing of cladding, glazing, door or gates and the like fixed with angle cleats and connecting plates etc. complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for 18-20 mm thick machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
S & F of 20 mm thick black granite (of any type) work (table rubbed and polished) having sandwich and bull nose molding on machine cut as in steps, jambs, pillars, window cills, cooking platforms and like, set in over and including 10 mm thick cement screed in cement mortar 1:3 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S & F of 1000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position with and including dismantling of existing old unserviceable one complete all as specified and directed.
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
S & F in repairs, PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc and S & F of 32 mm dia PVC flush pipe of suitable length, 450 mm long 15 mm size PVC connection, making all connections and making good disturbed surface complete all as specified and directed.
Complete removal to existing roof treatment from roof surface including dismantling of bricks or brick tiles laid dry (flat or on edge) complete all as specified and directed.
Demolition of existing mud in roofs, any thickness, including plastering and leeping complete all as specified and directed.
M & L for providing plain cement concrete, type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in levelling course over roof slab and the like after roughening of existing roof surface complete all as specified and directed.
Demolition of cement concrete (un-reinforced) any description and laid in any position complete all as specified and directed.
M & L for providing roof treatment comprising of the following specifications complete all as specified and directed: - (i) Rendering 10 mm thick cement plaster in cement mortar 1:3 mixed with and including polymer based water proofing compound over levelling course of concrete, when the concrete is still green. (ii) Applying a coat of bituminous primer @ 0.30 Liters per Sqm over fully dried plastered surface. (iii) Applying a coat of hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg per Sqm to the entire roof surface over primed surface. (iv) Laying of polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film and standard weight 3 Kg per Sqm with minimum 100 mm side and end laps as per manufacture’s instructions and strict supervision of manufacture’s technical representative. (v) Laying brick tiles, using sub class 'B' brick tiles laid over and including 20 mm thick screed bedding layer in cement mortar 1:4 mixed with and including polymer based liquid water proofing compound @ 5% by the weight of cement or as per manufacturer’s specifications / instructions including filling of tile joints filled with polymer based cement proofing joint filler manufactured by approved company.
Removing surplus excavated material (SOIL) to distance exc. 1.50 Kilometer and not exc. 5.00 kilometer and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
M & L for 50 mm spread thickness, sub base of Moorum / Red Bajri, spread, rolled and consolidated to required finished surface complete all as specified and directed.
M & L for providing 50 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for rubber moulded glossy finish coloured chequered cement concrete tiles of size 300 mm X 300 mm X 25 mm thick, set, jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor, over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for providing plain cement concrete type B-0, 1:2:4, (using 12.5 mm graded stone aggregate), as in roof kerb, mud stops and the like slightly rounded or chamfered at ends as required complete all as specified and directed.
S & F of 5 mm thick and 35 mm wide PVC sheet fillet for fixing of wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of solid PVC Wall Lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of 5 mm thick Printed PVC sheet in strips and channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent cement as per specifications and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor, finishing top surface even and smooth with using extra cement complete all as specified and directed.
S & F of rolled mild steel joist, channel, angle, flat iron or Tee sections, fixed independently without connecting plates etc. (cut to ordinary length i.e. within 20 mm of length) confirming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W (Grade E-250) quality-A complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in soft / loose soil, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as in apron, road / path, hard standing etc., finished surface even and smooth without using extra cement with and including all necessary form work as required complete all as specified and directed.
S & F of stainless steel tubing of circular/ square/ rectangular in shape, thickness of wall not less than 3 mm of grade AISI-316 (type Austenitic, anticorrosive in nature) as in frame work for road sign board and the like including necessary cutting, bending, welding / brazing complete all as specified and directed.
S & F of aluminium composite panel sheet of 5 mm thick with skin thickness of 0.25 mm of aluminium on both sides, sandwiched by 4.5 mm thick polyethylene core with PVDF coating of 30 micron, fixed to framework of road sign board and the like complete all as specified and directed.
S & F of high intensity prismatic retro reflective self adhesive sheet of make 3M or equivalent make as approved by GE, fixed to sign board with suitable border of approved colour as per site requirement complete all as specified and as directed.
S & F of alphabetical, numerical letters / signs cut from high intensity prismatic retro reflective self adhesive sheet of make 3M or equivalent make as approved by GE and fixed on sign board of approved colour as per site requirement complete all as specified and as directed.
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, light fittings, shade conical etc. and separating serviceable fittings for reuse in the work as directed including removing of unserviceable fittings & fixtures with wiring cable, battens, wooden boards etc. from site and making good disturbed surfaces of walls, floors ceiling etc. complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring of any description including batten or conduit complete all as specified and directed.
M & L for point wiring in colour coding Red, Black and Green (RBG) for one light point / fan point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) conforming to IS-694, drawn into and including non-metallic regid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 93.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 93.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F of lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
S & F of ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
S & F of electronic type fan regulator 230 volts, step type having five steps, switch type, hum free complete all as specified and directed.
S & F of 1100 volts grade heavy duty two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed for the following: -
(a) 2 X 4.00 sqmm as main wires + 1 X 4.00 sqmm as earth wire.
(b) 2 X 6.00 sqmm as main wires + 1 X 6.00 sqmm as earth wire.
(c) 2 X 10.00 sqmm as main wires + 1 X 10.00 sqmm as earth wire.
S & F as in replacement of old tube light fitting any type and description, new wall / surface mounted type LED light fitting 1 X 20 watt (4 feet long), as per Cat. Part No. BN021C LED20S PSU CW GR S2 (SmartBright) of Philips or ENDURALINEARNEOBS20WLED865SPCWH of Havells, extruded aluminium batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible three core 1.50 sqmm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed.
S & F as in replacement of old tube light fitting any type and description, new wall / surface mounted type LED light fitting 1 X 10 watt (2 feet long), as per Cat. Part No. BN021C LED10S 6500 PSU GR S1 (SmartBright) of Philips or ENDURALINEARNEOBS10WLED865SPCWH of Havells, extruded aluminium batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible three core 1.50 sqmm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed.
S & F of retrofit type LED lamp 12 watt capacity complete all as specified and directed.
S & F as in replacement suspended surface mounting fullglow high efficiency glare free LED luminaire suitable for 2'x2' ceiling grid as per Cat. Part No. RC380B LED 36S-6500 G4 L60W60 PSU OD (FullGlow) of Philips or PLUTOSURFACE2X2PLS42WLED857S (Pluto Panel Surface) of Havells or LM24-421-XXX-57-DD (Immaculate DD) of Wipro duly pre-fitted with all accessories complete all as specified and directed.
S & F as in replacement LED street light fitting as per Cat. Part No. Cat. Part No. BRP062 LED 65 CW SLA S1 PSU (SmartBright Street) of Philips or ENDURACITYLINERNEOSL70WLED757PASYBOTG of Havells or LR02-781-XXX-57-G2 (Skyline) of Wipro with and including street light bracket made of suitable dia GI pipe light grade not less than 0.65 metre length alongwith fixing arrangement complete all as specified and directed.
Supply and fixing of 1200 mm sweep 240 volts, AC having BEE 5 star rating ISI marked, off white coloured ceiling fan complete with fan blade, capacitor, canopy, down rod etc. with and including making electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of ceiling fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old ceiling fan any type and depositing the same in MES store complete all as specified and directed.
Supply and fixing of 300 mm sweep heavy duty metal body exhaust fan, single phase 230 volts AC, 900 RPM complete with and including all accessories, louver shutter at the existing place of old exhaust fan, grouting of ragged bolts in wall as required for fixing of exhaust fan, frame, louvers and making new electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of exhaust fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old exhaust fan any type and depositing the same in MES store complete all as specified and directed.
Supply and fixing of 450 mm sweep heavy duty metal body exhaust fan, single phase 230 volts AC, 900 RPM complete with and including all accessories, louver shutter at the existing place of old exhaust fan, grouting of ragged bolts in wall as required for fixing of exhaust fan, frame, louvers and making new electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of exhaust fan and writing MES No. with black synthetic enamel paint minimum font size 2.00 cm high with and including taking down old exhaust fan any type and depositing the same in MES store complete all as specified and directed.
S & F of factory made V TPN DBs-DPX-160 MCCB DB's, 4 way, IP-43 protection-IK09 with metal door with 160 Amperes copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and SP 09 Nos. and TP 01 No. MCB's as outgoing with and including dismantling of old unserviceable one alongwith old MCCBs, MCBs and the like complete all as specified and directed. (Cat. Part No. 507745 of Legrand or Cat. Part No. A9HVD04M of SCHNEIDER or Cat. Part No. CSDBMCCB225DD04IP43 of C&S)
S & F of flush mounting factory made SPN DB's Double door, 8 way (Cat. Part No. 607711 of Legrand or Cat. Part No. A9HSND08 of SCHNEIDER or Cat. Part No. CSDBSPNDD08 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar with and including dismantling of old unserviceable one alongwith old MCBs and the like complete all as specified and directed.
S & F of flush mounting factory made SPN DB's Double door, 4 way (Cat. Part No. 607710 of Legrand or Cat. Part No. A9HSND04 of SCHNEIDER or Cat. Part No. CSDBSPNDD04 of C&S), IP-43 Protection, IK-09 with metal door, with neutral bar, Earth bar and cables ties for cable management fully insulated bus bar with and including dismantling of old unserviceable one alongwith old MCBs and the like complete all as specified and directed.
S & F of MCCBs, 63 Ampere, 415 volts, 4 pole, 16 KA, thermal magnetic all as specified and directed. MAKE- Legrand or L&T or C&S.
S & F of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one No. single pole MCB 20 Ampere capacity 240 Volts as per Cat. Part No. 607841 of Legrand or CSDBPSSPN020 of C&S with and including dismantling of old unserviceable one alongwith old MCB and the like complete all as specified and directed.
S & F of MCB single pole and neutral, 240 volts, 63 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed.
S & F of MCB single pole and neutral, 240 volts, 40 Ampere breaking capacity 10 KA, ‘C’ Series complete all as specified and directed.
S & F of MCB single pole 240 volts, 6 to 32 Ampere 50 Hz, 10 KA, ‘C’ series complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Taking down carefully ceiling fan any sweep and type, cleaning, oiling and greasing thoroughly including painting with one coat of synthetic enamel paint approved colour after cleaning and preparing the surface and re-fixing the same at existing site / rooms and connected with 23/0.0076 size three core PVC flexible cable from ceiling rose to connector of ceiling fan complete all as specified and directed.
Alishba Enterprises
Ikrar khan & co.
MOHINDER SINGH AND SONS
Zaigham Enterprises
VINOD TRADING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .