Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.4 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹86.4 L+₹24.0 L (38.4%)Rejected-AOC | L2 | Rejected-AOC L2 BIDDER |
Tender Value
₹58 L
EMD Value
₹85,000
Closing Date
31 Aug 2021, 3:00 pmClosed
Deputy General Manager (Projects)
Projects Division, HLL Bhavan, HLL Lifecare Ltd, Poojappura - 695012
Electrical Works for Operationalization of KSRTC Bus Terminal cum Shopping Complex at Thodupuzha, Idukki
2021_HLL_434166_1
HLL/CHO/PROJ/EXT/KSRTC/TDPA/EL
Open Tender
Electrical Works
Item Rate
112 days
Thodupuzha
Please refer Tender documents.
10 documents required · 10 mandatory
₹5,900
Yes
₹85,000
Yes
20 Jan 2022
9 Aug 2021
1 Sept 2021
9 Aug 2021
31 Aug 2021
9 Aug 2021
Amount
Wiring
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Group C.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
DB, Switchgear and Protection
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps,
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 6 way, Double door
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole and Neutral
Point Fixtures
Supply, conveyance and Installation of compact Surface or Recess mounted, square, 15cm x 15cm, 18W LED luminaire with High translucent diffuser gives soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, along with dismantling/cutting false ceiling and making good the damages as required complete. (Philips/WIPRO/Havells or equivalent)
Supply, conveyance and Installation of compact, 4 feet, 28 W, T5 LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent)
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep - 5 star rated, 3 blade ceiling fan complete with 300mm down rod , canopies, shackles.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply, conveyance and Installation of compact, 2 feet, 18 W, T5 LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent)
Supply of 250mm sweep, Single phase Light duty exhaust fan having High Suction at low noise with aerodynamically designed blades, silent, 100% copper motor along with all mounting accessories complete
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep
Supply, conveyance and Installation of compact Surface or Recess mounted, 60cm x 60cm, 36W LED luminaire with High transculent diffuser gives soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, along with dismantling/cutting false ceiling and making good the damages as required complete. (Philips/WIPRO/Havells or equivalent)
Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent)
Air Conditioning Works
Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation up to 4 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1.5 TR 3 Star rated (inverter type AC) as per BEE
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through PVC duct inside false ceiling
Internet LAN cabling
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required 1 run of Cable
Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manger and PDU of 4 or 6 sockets including cooling fan with accessories complete
Network Switch. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: Cisco/CP Plus/Netgear or equivalent
Supply and fixing of RJ 45 socket outlet along with modular plate including connectors and crimping the same to the CAT6 cables complete, Make: D-Link/TP-Link or equivalent
Supply and Installation of 24 port loaded Patch Panel including accessories complete
Cable Tray
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
LT Cabling and Termination
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 50 sq mm with factory made clamp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 70 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 120 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct/cable tray as required. 3.5 core 240 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 240 sq. mm (62mm)
Supply and Laying of 6 fiber optical fiber cable in PVC conduit along with labour and all necessary terminations as required.
Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manger and PDU of 4 or 6 sockets including cooling fan with accessories complete
Supply and Installation of LED Color Monitor of minimum 32 inch screen, complete, 1920 x 1080p displayMake: LG/Samsung/Panasonic or equivalent
Supply, Installation of 600VA UPS, with inbuilt battery, 230v, 50Hz,Line interactive Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof. Make: V-Guard, APC, Luminous or equivalent
Supply and Integration of 4 TB Surveillance Harddisk Drive. Make : WD/Seagate/TOSHIBA or equivalent
Supply, Installation and Integration of minimum 12 Port PoE Network Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 12 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az). Make: Cisco/CP Plus/Netgear/Dahua or equivalent
Supply, Conveyance and Installing of 2MP IP Dome Camera having 1/3" Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty.Make: Bosch/CP Plus/Honeywell or equivalent
64 channel embedded Linux NVR (Network Video Recorder), must connect 64 channel IP cameras , Should support min 8 SATA HDD and each should support Min 6TB and must record video simulataneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, including power adapter , minimum 2 Year Warranty, (Image quality should be maintained throughout the warranty period) Make: Bosch/CP Plus/Honeywell or equivalent
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Panels
Supply, Installation, Testing & Commissioning of LT, cubicle type, Panel made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket / PU etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. 125A, TPN, 35kA, MCCB, thermal magnetic having adjustable O/L, SC protection - 1 no. 1 Set of 160 A TPN busbars of high conductivity electrolytic quality Aluminum alloy and suitable size earthing conductor through out the panel for its earthing. Instruments-2A, C curve SP MCB - 1 set, RYB indication lamp, LED type - 1 set, 1 Nos 3 phase Digital Multi function meter to read V, A, F, PF, kW, kWh Acc class 1.125/5A, 10VA, class 1, resin cast CT - 1 set, Outgoing - (1) 63A, TPN, 16kA, MCCB, thermal magnetic having adjustable O/L protection - 4 nos., (2) 40A, TPN, 16kA, MCCB, thermal magnetic having adjustable O/L protection - 4 nos., facility for connecting 6 No of energy meters.
Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 200A, TPN ISOLATOR, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 200A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCB including providing control cable and connections from MSB to Capacitor panels,etc. complete Out Going: 40A TP MCB- 2 Nos.32A TP MCB- 1 No. 25A TP MCB- 2 Nos. 16A TP MCB- 1 Nos. ON-OFF DUTY Contactor Capacitor (AC 6B duty) - 6 set, ON-OFF Push buttons - 2 set, 20kVAr Capacitor bank- 2 Nos.15kVAr Capacitor bank- 2 Nos, 10kVAr Capacitor bank- 2 Nos, 5kVAr Capacitor bank- 1 No, Panel Board as per above specification- 1 No.
Safety Equipment
Providing of rubber mat 1 mtr x 2 mtr having thickness 2.5 mm , insulation strength to withstand voltages upto 15 kV as per IS 5424:1969
Providing of rubber mat 1 mtr x 2 mtr having thickness 2mm , insulation strength to withstand voltages upto 3.3 kV as per IS 5424:1969
Supplying and fixing safety instruction chart in word duly framed with 5 mm thick glass as required (approximate area 1.2 sqm)
Providing of set of 4 nos 9.5 ltr capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint 'FIRE' and mounted on M S angle iron frame with bracket of appropriate size including filling with sand.
Preparation of Single Line Diagram and fixing the same depicting all manner of power distribution concerning the building duly framed with 5mm thick glass as required ( approximate area 2 sqm
Miscellaneous
Preparation of all drawings, submit to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval and sanction. (All statutory fees shall be borne by Client - Actual amount shall be paid after submission of bill)
Supply, Installation, testing and Commissioning of three phase electronic type energy meter with LCD display with battery backup, class 1.00 CT. The whole unit to be mounted on suitable metal enclosure (powder coated with locking arrangement, separate enclosure for incoming and outgoing) with required HRC fuses, Neutral link and all connections complete
UPS and accessories
Supply, Installation, Testing and Commissioning of Single phase, 5 kVA Online UPS along with Maintenance free SMF batteries and battery rack complete with 2 hr backup. UPS must have inbuilt Short Circuit, Over-Current Over-Voltage protection. Minimum 2 year warranty. Make: APC/V-Guard/Luminous or equivalent
HELSA ELECTRICALS PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .