| 1 | L1₹2.2 LAccepted-AOC | L1 | Accepted-AOC Agreement executed by R Mohanan on 18.04.2023 |
Tender Value
₹2.2 L
EMD Value
₹5,400
Closing Date
28 Dec 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer Thiruvananthapuram Corporation 695033
Providing electrification for the newly constructed Dental unit at Govt. Thaluk Hospital Fort under city corporation Thiruvananthapuram.
2022_LSGD_533356_9
EE(N)/OWNFUND TENDER/2022-23 (18)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹5,400
Yes
28 Apr 2023
21 Dec 2022
30 Dec 2022
21 Dec 2022
28 Dec 2022
21 Dec 2022
Amount
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
90.3.20.3 Supply & installation of light fittings on TW round block<br>Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture.
od 1753271 / 2022-2023 90.4.5.4 Supply,installation testing and commissioning of ceiling fan of the following sizes including wiring the down rods standard length (up to 30 cm )with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc.as required. 1200mm sweep ceiling fan complete with service value minimum 4.0 (cub meter/ minite /watt ) air delivery minimum 210 cubic meter / minite )copper wiring suitable for 230/240V single phase A/C supply
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required
od 1753270 / 2022-2023 Supply and providing the following types and power rated lamps inthe existing fittings as required B22 LED bulb 10 W
od 17532810/ 2022-2023 Supply and fixing cast aluminium bulk head fittings with mesh guard with 7 W LED bulb and giving connection etc as required
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.10.3.14 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A DP switch with indicator
90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 X 1.5 sq.mm
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 X 1.5 sq.mm
.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.31 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pol
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required 3 pin 5/6 Amp socket outlet.
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required 3 pin 5/6 Amp switch.
od 1269966 / 2021-2022 Supply and conveyance installation testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R4 10A / R32 non CFC refigerant capable of performing functions like Cooling Dehumidifying air circulating filtering etc of following capacity, micro processor control with cordless remote control etc.including electric cable copper pipe and thermal insulation up to 4 M as required with one year on site warrenty, 5 year compressor warrenty and one year free service. 100% copper 2.0 TR 3 star 1 phase invertor type split AC unit (Voltas / equilant make of PWD approved with ISI )
od 73367/2020-21: Supply of 3.45 KVA volage stebilizer suitable for 2.0TE single phase spilit type A/C unit with voltage range of 170-270V having built in thermal overload protection; Low & High Voltage cut -off and Low & High Voltage Cut off Protection--Protects connected equipment from potentially dangerous voltages (V guard VG 500 or equilant)
od 73365/2020-21: Supply providing the following size soft drawn copper pipe for extending the pipe bettween outdoor and indoor unit, including insulating the pipe using rubbrised foam sleeve 10mm thick, brazing, leak testing etc. :- 3/8 inch (9.525 mm) and 5/8 inch (15.875 mm) 22 gauge
LMR Supply and providing brackets
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_789502.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .