Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC D NO 50 53 2 5 FLAT NO 504 SRI SAI VENKATESWARA RESIDENCY NE LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹3.7 Cr+₹25.8 L (7.42%)Rejected-Finance 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹4.7 Cr+₹1.2 Cr (34.4%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | NEW DELHI | DELHI | 110063 | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Being affidavits, Solvency, Working capital as per Manual on contracts not submitted | |
| 5 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | - | Rejected-Technical Being not qualified for enlistment in relevant class of work and affidavits as per manual on contracts not submitted |
| Sl No | Description | Qty | Unit | Mahamaruti Constructions L1 | Kakolil Trade Agencies L2 | M/s R. K. Bhambri L3 |
|---|---|---|---|---|---|---|
| 1.00 | PHASE-I : [Schedule "A" Part – I] (Item Nos. 01 to 78):
Design, engineering, collection and testing of raw sewage samples, preparation and submission of complete treatment scheme, obtaining approval of Accepting Officer including Supply, installation, testing and commissioning of fully automatic Package Type Sewage Treatment Plant (STP) of 80 KLD capacity at Key personal quarters near SVN Colony, visakhapatnam with teritary treatment based on any proven and approved sewage treatment technology suitable for achieving the following treated effluent parameters and all as specified in the policy guidelines and / or statutory norms including CPCB norms, MoEF&CC guidelines, NBC provisions and local Pollution Control Board requirements, complete in all respects and as directed by Engineer-in-Charge:
[Note: Bidders are required to submit the documents in support of their eligibility for bidding as per PQC specified in NIT ]
(a) pH - 6.5 to 8.3,
(b) COD – less than 50 mg/L,
(c) BOD – less than 10 mg/L,
(d) TSS – less than10 mg/L,
(e) Total Nitrogen - 10 mg/L,
(f) Total Phosphorous 1 mg/L,
(g) Fecal Coliform - NIL, and
(h) Odour - No foul odour
(j) COMPONENTS OF STP PLANT: The equipment for the STP shall be as per OEM Recommendations: | 1 | JOB | 58,50,000 ₹58,50,000 Lowest | 99,99,000 ₹99,99,000 | 1,35,00,000 ₹1,35,00,000 |
| 1.01[i] Since the design of STP shall be as per OEM, please note that unit rate quoted for Sewage Treatment Plant shall be deemed to be inclusive of full and final completion of work as per BoQ, Particular Specifications and specifications as per OEM recommendations read in conjunction with each other. Any item not covered in the scope of work but essential for smooth functioning of STP shall be provided as per OEM/Technology providers recommendations. The quoted rate is inclusive for the same. No additional claim whatsoever in this regard shall be entertained. [ii] The complete scheme of STP shall be vetted by OEM / technology provider for its 80 KLD sewage hold by capacity. [iii] STP has to process input sewage from raw sewage well. Any other component to align STP with raw sewage well is deemed to be inclusive in scheme of STP under this item. [iv] Cost of all spares and consumables required during defects liability period for keeping the system functional, is deemed to be inclusive in the unit rate quoted under this item. No additional claim whatsoever shall be entertained at later date. | ||||||
| 1.02Notes for item No 1.00 & 1.01 above:- (a) The scope shall include detailed survey, collection and laboratory testing of raw sewage by the contractor at his own cost for assessment of influent characteristics and preparation of complete process design accordingly. The technology and process adopted shall be open-ended and performance based, and no specific technology shall be mandatory, however the proposed technology shall be proven, energy efficient, suitable for Visakhapatnam climatic conditions, compact, low maintenance and capable of consistent performance under varying hydraulic and organic loads. (b) The item shall include but not be limited to design, planning, detailed engineering, architectural drawings, structural drawings, process flow diagrams (PFD), piping and instrumentation diagrams (P&ID), hydraulic calculations, electrical SLDs, cable schedules, instrumentation layouts, SCADA architecture, equipment GA drawings, foundation details and all other working drawings required for execution and operation of the plant. The complete design and drawings shall be vetted by any IIT/NIT and submitted by the contractor within 30 days from the date of acceptance through proper channel to the Accepting Officer for approval prior to commencement of work. | ||||||
| 1.03(c) The scope shall include all civil works, mechanical works, electrical works, instrumentation works, automation works and associated allied works from receiving raw sewage at inlet point up to storage of treated effluent in treated water storage tank, excluding the following:- (i) Raw sewage collection tank with screen chamber (separately provided under another schedule item) (ii) External incoming sewer/inlet pipeline up to Raw sewage collection tank. (iii) External treated water outlet pipelines beyond treated water storage tank battery limit. (d) The scope shall however include all pumpsets, blowers, screw pumps etc as per OEM design with 01 working + 01 standby, internal interconnecting pipelines, valves, fittings, specials, manifolds, channels, launders, supports, pipe bridges, internal sewer lines, sludge lines, air lines, chemical dosing lines, filtration lines, flushing lines, recirculation lines and all associated piping within the STP package limits complete. (e) The item shall include all RCC, PCC, masonry, plastering, waterproofing, anti-corrosive treatment, epoxy coating, flooring, trenches, foundations, equipment pedestals, paving, drainage arrangements, covers, staircases, handrails, ladders, chequered plates, structural steel works, sheds/buildings and all other civil and structural components forming part of package type STP required for complete functioning of the STP. | ||||||
| 1.04(f) The scope shall include all process equipment and accessories such as screening arrangements, grit removal system, oil & grease removal system, equalization arrangements (if part of package), aeration system, blowers, diffusers, bio-reactors, clarifiers, media, tube settlers, pumps, mixers, agitators, sludge handling system, filter feed pumps, filter units, tertiary treatment units, activated carbon filters, pressure sand filters, disinfection system, chlorination/UV/ozonation system, chemical dosing systems, sludge drying arrangements, odour control arrangements and all accessories including all Raw sewage & treated water pump sets complete as per approved design. (g) The item shall also include complete tertiary treatment system for achieving reuse quality treated water suitable for arboriculture applications as specified in contract documents and policy guidelines. (h) The scope shall include complete internal electrification and power distribution system including LT panel, MCC, APFC panel, PLC based automation panel, SCADA system, mimic panels, HMI, instrumentation, sensors, analyzers, level transmitters, flow meters, pressure gauges, online monitoring system, local control stations, all power/control wiring, copper/aluminium cables, control cables, communication cables, cable trays, earthing, lightning protection, glands, lugs, terminations, starters, VFDs, illumination, exhaust fans, sockets and all accessories complete. | ||||||
| 1.05Designing, supplying, Devloping, installing, integrating and commissioning of SCADA system for 80 KLD STP along with various automation equipment for STP as indicated. The SCADA System shall comprises of followings:- (a) Central monitoring station (CMS) with Desktop Computer all in one PC (i5 with 500 GB SSD & 8 GB RAM/ 14 Gen, Windows 11 Original, and Screen 23.8 . The storage capacity of hard disk shall be suitable for storing the data for a minimum period of six months (or) 500 GB whichever is higher. (Make: HP/DELL/ACER). (b) UPS with half an hour backup. (c) Colour Laser Printer. (d) Data Gateway. (e) SCADA software which can be operated, programmed and modified by agencies other than developer (f) PLC/ Microprocessor Controllers with indoor/ outdoor applications for water sensing display, pump operation with RTU/ without RTU or Microprocessor controller and microprocessor transmitter. (g) Suitable communication system including payment of bills to Telecom service provider up to completion of DLP. (h) Pressure Transmitter (j) Ultrasonic Sensors (k) Flow meter and switches (l) Online continous effluent monitoring system (OCEMS) | ||||||
| 1.06Notes for item No 1.05 :- (i) Design report shall be submitted before execution of Work at site by the contractor to the Accepting Officer through proper channel for approval. (ii) Design of Communication System shall be done by the bidder. Cloud based server/ data storage/communication shall not be used and only local server based system shall be designed. (iii) The cost of each item shall also be attached to arrive at pricing in case of some addition/ reduction at site (iv) Operating system, system software and programming shall not be intellectual property of any agency. (v) The memory in the hard disk shall be suitable for six months data. The backup storage device/ devices shall be provided for archiving of data more than six months old. (vi) In case of addition of installations, the system shall be capable of integrating the same. (vii) The responsibility of the agency is restricted to intimate mechanical and electrical failures such as failure of pumps, leakages, etc such repairs for items like pump, water pipe line, leakages etc not forming part of the SCADA system shall be carried out by MES. (viii) The SCADA system should have provision of both manual and automatic operation of installations. (ix) All outdoor items to be installed shall be suitable for all weather conditions (x) The contractor shall submit details of preventive maintenance carried out quarterly and shall also submit fitness certificate of system. (xi) The quoted rate is deemed to be inclusive for maintenance during defects liability period after completion of Phase-I. | ||||||
| 1.07(xii) Cost of all spares required during defects liability period for keeping the system functional, operation including payment of bills by telecom service provider is deemed to be inclusive in the rate quoted above. No claim whatsoever shall be entertained at later date. SCADA to cover automation and sample analyzers. The system should provide following data on a central monitor:- Cumulative sewage flow. Cumulative treated wastewater flow. All parameters mandated by NGT guidelines through online monitoring of treated wastewater (effluent). Any event occurring not as per design to be highlighted onscreen. Accessibility of details on logging in remotely. | ||||||
| 1.08Notes for item No 1.00 to 1.07:- (a) It should be ensured that all interested firms should have adequate experience and should have demonstrative capabilities of successfully ensuring instrumentation/automation. (b) Item numbers and requirement will vary based on site. (c) This list is not exhaustive and necessary addition/deletion/ changes should be carried out as per specific requirement. (d) The SCADA system shall provide automatic operation, monitoring, alarms, trend analysis, data logging, remote monitoring capability, historical data storage and report generation for all critical parameters and equipment. Necessary software licenses, programming, integration, commissioning, testing and operator training shall be included in the quoted rate. All hardware and software shall be genuine and licensed. (e) The contractor shall be fully responsible for design adequacy, process performance, hydraulic performance, structural stability, mechanical reliability, electrical safety and statutory compliance of the entire system. The contractor shall guarantee the treated effluent quality parameters as specified in the contract under all operating conditions within the design parameters. Any modification, additional equipment, civil work, instrumentation, chemical dosing or process improvement required for achieving guaranteed performance during execution or defect liability period shall be carried out by the contractor at no extra cost to the department. | ||||||
| 1.09(f) The quoted rate shall be deemed to include all labour, materials, T&P, consumables, chemicals during commissioning, loading/unloading, transportation, transit insurance, testing, third party inspection if required, statutory approvals, safety measures, barricading, trial runs, performance testing, commissioning, operator training, O&M manuals, as-built drawings, documentation and all incidental charges whatsoever necessary for successful completion and handing over of the plant in fully functional condition. (g) The contractor shall carry out testing and commissioning of the complete plant and demonstrate satisfactory performance continuously for a minimum period as specified by the Accepting Officer before handing over. Treated effluent samples shall be tested from NABL accredited laboratory and results submitted to the department. Completion report and final bill shall be processed after successful commissioning and achievement of guaranteed treated water characteristics. (h) Monthly testing of treated water from NABL shall be submitted to the department during DLP. Cost of the same included in the quoted raets. (j) The item shall be measured and paid as one complete Lump Sum job irrespective of individual components, quantities, capacities, equipment details or execution methodology. No extra payment shall be admissible for any item, component, accessory, equipment, design requirement, statutory compliance, civil work, electrical work, instrumentation, SCADA integration, piping, cabling or any other work required for satisfactory completion and performance of the STP whether specifically mentioned or not, complete and functional operation of the STP system and as per OEM recommendations. | ||||||
Tender Value
₹3.8 Cr
EMD Value
₹4.5 L
Closing Date
1 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Shinde SS, Commander Works Engineer
Commander Works Engineers, Visakhapatnam
PROVISION OF DEFICIENT SEWAGE TREATMENT PLANTS WITH ALLIED WORKS AT CERTAIN LOCATIONS UNDER GE (U-II), VISAKHAPATNAM
2026_MES_779750_1
82691/E8
Open Tender
Civil Works
Item Rate
365 days
Visakhapatnam
As per NIT
9 documents required · 9 mandatory
₹2,000
Garrison Engineer Utility - II
₹4.5 L
Yes
9 Nov 2026
20 Jul 2026
3 Sept 2026
20 Jul 2026
1 Sept 2026
11 Aug 2026
20 Jul 2026 - 27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | PHASE-I : [Schedule "A" Part – I] (Item Nos. 01 to 78):
Design, engineering, collection and testing of raw sewage samples, preparation and submission of complete treatment scheme, obtaining approval of Accepting Officer including Supply, installation, testing and commissioning of fully automatic Package Type Sewage Treatment Plant (STP) of 80 KLD capacity at Key personal quarters near SVN Colony, visakhapatnam with teritary treatment based on any proven and approved sewage treatment technology suitable for achieving the following treated effluent parameters and all as specified in the policy guidelines and / or statutory norms including CPCB norms, MoEF&CC guidelines, NBC provisions and local Pollution Control Board requirements, complete in all respects and as directed by Engineer-in-Charge:
[Note: Bidders are required to submit the documents in support of their eligibility for bidding as per PQC specified in NIT ]
(a) pH - 6.5 to 8.3,
(b) COD – less than 50 mg/L,
(c) BOD – less than 10 mg/L,
(d) TSS – less than10 mg/L,
(e) Total Nitrogen - 10 mg/L,
(f) Total Phosphorous 1 mg/L,
(g) Fecal Coliform - NIL, and
(h) Odour - No foul odour
(j) COMPONENTS OF STP PLANT: The equipment for the STP shall be as per OEM Recommendations: | 1 | JOB | - | - |
| 1.01 | [i] Since the design of STP shall be as per OEM, please note that unit rate quoted for Sewage Treatment Plant shall be deemed to be inclusive of full and final completion of work as per BoQ, Particular Specifications and specifications as per OEM recommendations read in conjunction with each other. Any item not covered in the scope of work but essential for smooth functioning of STP shall be provided as per OEM/Technology providers recommendations. The quoted rate is inclusive for the same. No additional claim whatsoever in this regard shall be entertained.
[ii] The complete scheme of STP shall be vetted by OEM / technology provider for its 80 KLD sewage hold by capacity.
[iii] STP has to process input sewage from raw sewage well. Any other component to align STP with raw sewage well is deemed to be inclusive in scheme of STP under this item.
[iv] Cost of all spares and consumables required during defects liability period for keeping the system functional, is deemed to be inclusive in the unit rate quoted under this item. No additional claim whatsoever shall be entertained at later date. | - | - | - | - |
| 1.03 | (c) The scope shall include all civil works, mechanical works, electrical works, instrumentation works, automation works and associated allied works from receiving raw sewage at inlet point up to storage of treated effluent in treated water storage tank, excluding the following:-
(i) Raw sewage collection tank with screen chamber (separately provided under another schedule item)
(ii) External incoming sewer/inlet pipeline up to Raw sewage collection tank.
(iii) External treated water outlet pipelines beyond treated water storage tank battery limit.
(d) The scope shall however include all pumpsets, blowers, screw pumps etc as per OEM design with 01 working + 01 standby, internal interconnecting pipelines, valves, fittings, specials, manifolds, channels, launders, supports, pipe bridges, internal sewer lines, sludge lines, air lines, chemical dosing lines, filtration lines, flushing lines, recirculation lines and all associated piping within the STP package limits complete.
(e) The item shall include all RCC, PCC, masonry, plastering, waterproofing, anti-corrosive treatment, epoxy coating, flooring, trenches, foundations, equipment pedestals, paving, drainage arrangements, covers, staircases, handrails, ladders, chequered plates, structural steel works, sheds/buildings and all other civil and structural components forming part of package type STP required for complete functioning of the STP. | - | - | - | - |
| 1.04 | (f) The scope shall include all process equipment and accessories such as screening arrangements, grit removal system, oil & grease removal system, equalization arrangements (if part of package), aeration system, blowers, diffusers, bio-reactors, clarifiers, media, tube settlers, pumps, mixers, agitators, sludge handling system, filter feed pumps, filter units, tertiary treatment units, activated carbon filters, pressure sand filters, disinfection system, chlorination/UV/ozonation system, chemical dosing systems, sludge drying arrangements, odour control arrangements and all accessories including all Raw sewage & treated water pump sets complete as per approved design.
(g) The item shall also include complete tertiary treatment system for achieving reuse quality treated water suitable for arboriculture applications as specified in contract documents and policy guidelines.
(h) The scope shall include complete internal electrification and power distribution system including LT panel, MCC, APFC panel, PLC based automation panel, SCADA system, mimic panels, HMI, instrumentation, sensors, analyzers, level transmitters, flow meters, pressure gauges, online monitoring system, local control stations, all power/control wiring, copper/aluminium cables, control cables, communication cables, cable trays, earthing, lightning protection, glands, lugs, terminations, starters, VFDs, illumination, exhaust fans, sockets and all accessories complete. | - | - | - | - |
| 1.05 | Designing, supplying, Devloping, installing, integrating and commissioning of SCADA system for 80 KLD STP along with various automation equipment for STP as indicated. The SCADA System shall comprises of followings:-
(a) Central monitoring station (CMS) with Desktop Computer all in one PC (i5 with 500 GB SSD & 8 GB RAM/ 14 Gen, Windows 11 Original, and Screen 23.8 . The storage capacity of hard disk shall be suitable for storing the data for a minimum period of six months (or) 500 GB whichever is higher. (Make: HP/DELL/ACER).
(b) UPS with half an hour backup.
(c) Colour Laser Printer.
(d) Data Gateway.
(e) SCADA software which can be operated, programmed and modified by agencies other than developer
(f) PLC/ Microprocessor Controllers with indoor/ outdoor applications for water sensing display, pump operation with RTU/ without RTU or Microprocessor controller and microprocessor transmitter.
(g) Suitable communication system including payment of bills to Telecom service provider up to completion of DLP.
(h) Pressure Transmitter
(j) Ultrasonic Sensors
(k) Flow meter and switches
(l) Online continous effluent monitoring system (OCEMS) | - | - | - | - |
| 1.07 | (xii) Cost of all spares required during defects liability period for keeping the system functional, operation including payment of bills by telecom service provider is deemed to be inclusive in the rate quoted above. No claim whatsoever shall be entertained at later date.
SCADA to cover automation and sample analyzers. The system should provide following data on a central monitor:-
Cumulative sewage flow.
Cumulative treated wastewater flow.
All parameters mandated by NGT guidelines through online monitoring of treated wastewater (effluent).
Any event occurring not as per design to be highlighted onscreen.
Accessibility of details on logging in remotely. | - | - | - | - |
| 1.09 | (f) The quoted rate shall be deemed to include all labour, materials, T&P, consumables, chemicals during commissioning, loading/unloading, transportation, transit insurance, testing, third party inspection if required, statutory approvals, safety measures, barricading, trial runs, performance testing, commissioning, operator training, O&M manuals, as-built drawings, documentation and all incidental charges whatsoever necessary for successful completion and handing over of the plant in fully functional condition.
(g) The contractor shall carry out testing and commissioning of the complete plant and demonstrate satisfactory performance continuously for a minimum period as specified by the Accepting Officer before handing over. Treated effluent samples shall be tested from NABL accredited laboratory and results submitted to the department. Completion report and final bill shall be processed after successful commissioning and achievement of guaranteed treated water characteristics.
(h) Monthly testing of treated water from NABL shall be submitted to the department during DLP. Cost of the same included in the quoted raets.
(j) The item shall be measured and paid as one complete Lump Sum job irrespective of individual components, quantities, capacities, equipment details or execution methodology. No extra payment shall be admissible for any item, component, accessory, equipment, design requirement, statutory compliance, civil work, electrical work, instrumentation, SCADA integration, piping, cabling or any other work required for satisfactory completion and performance of the STP whether specifically mentioned or not, complete and functional operation of the STP system and as per OEM recommendations. | - | - | - | - |
| 2 | All as per item No. 1 to 1.09 above but for Sewage Treatment Plant of capacity 50 KLD at Dega Vihar, Visakhapatnam | 1 | JOB | - | - |
| 3 | Supplying, laying, jointing, testing and commissioning of 100mm dia, Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends of pressure rating 6 kgf/cm2 laid in trenches, suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and cement motor lining with Bituminous Seal coat on internal surfaces including all necessary DI fittings / specials complete all as specified and as directed by Engineer-in-Charge. | 200 | RM | - | - |
| 4Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and as directed. | |||||
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_873381.xls
BOQ • 0.38 MB
82691tender.pdf
Tender Documents • 1.67 MB
82691Datecorr.pdf
PDF • 0.54 MB
82691.pdf
PDF • 0.67 MB
82691BOQCORRIGENDUM.pdf
PDF • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .