Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC S O BALARAM NATH SRIRAMPUR KANCHANPUR NORTH TRIPURA 799270 | NORTH TRIPURA | TRIPURA | 799270 | L1 | Accepted-AOC lowest |
Tender Value
₹41.2 L
EMD Value
₹82,337
Closing Date
11 Mar 2024, 3:00 pmClosed
DY GENERAL MANAGER, KANCHANPUR
O/O THE DY GENERAL MANAGER, KANCHANPUR
Extension of HT Line/LT line and mtc of dead 11kv line
2024_POWER_48153_1
DGM/ED-KCP/23-24/16
Open Tender
Electrical Works
Item Wise
DASDA
PL REFER TO DNIET
2 documents required · 2 mandatory
₹5,000
Yes
₹82,337
6 Aug 2024
5 Mar 2024
11 Mar 2024
5 Mar 2024
11 Mar 2024
5 Mar 2024
Amount
Supply of the following line materials
63 kva Distribution Transformer
9.0 mtr long Galvonized Steel Tubular pole
9.0 mtr long PCC pole
8.0 mtr long Galvonized Steel Tubular pole
Stayset complete
Stay wire (7/2.5 mm dia.)
11KV Stay insulator
11kv Polimeric Disc insulator (45KN)
11 kv Disc fittings
11kv Polimeric Pin insulator
LT Shackle insulator
Straps Nuts & Bolts
11kv G.O. Switch, 3 phase
11kv D.O. fuse, 3 phase
11KV L.A (9 KV, 5KA)
M.S. channel (100x50x50x6mm)
M.S. channel (75x50x50x6mm)
M S angle(65x65x6)
M S angle(50x50x6)
ACSR (3/1/2.59 mm dia.)
10swg GI wire
HT Danger plate
Barbed wire
Cut out 200 amps
16mm PVC wire
PVC Cable 120 mm2
Bimetallic Lugs of size 95
Bimetallic Lugs of size 120
Meter CT ratio 100/5 Amps
Fabricated MS Clamp Made of 50x6mm MS Flat for X-arm & Stay set
MS Nuts & Bolts i/c washer of assorted size
2.5 mtr long, 40 mm dia G.I pipe (TATA/ JINDAL make)
Dismentalling of the following line materials
A.C.S.R. (6/1/2.59 mm)
GI Wire (10SWG)
Cradle Guard (HT)
11KV Disc insulator with fittings
11KV Pin Insulator with GI pin
Stay Set Complete
3.2 Mtr. Long MS Angle of Size 65x65x6mm for DT cross arm
2.2 Mtr. Long MS Angle of Size 65x65x6mm for DT cross arm
SP Top X-arm of 0.3 Mtr. Long MS Channel of Size 75x40x40x6mm
SP bottom X-arm of 1.2 Mtr. Long MS Channel of Size 75x40x40x6mm
SP Gaurd X-arm of 1.6 Mtr. Long MS Angle of Size 65x65x6 mm.
DP Top X-arm of 2.2 Mtr. Long MS Channel of Size 75x40x40x6mm.
DP Top Guard X-arm of 2.5 Mtr. Long MS Channel of Size 65x65x6 mm.
9.00 Mtr long Steel pole (D.P.)
9.00 Mtr long Steel pole (S.P.)
Erection of the following line materials
9.00 Mtr. Long Galvonized Steel Tubuler Pole
9.00 Mtr. Long PCC Pole
8.00 Mtr. Long Galvonized Steel Tubuler Pole
3.2 Mtr. Long MS Angle of Size 65x65x6mm for DT cross arm
2.2 Mtr. Long MS Angle of Size 65x65x6mm for DT cross arm
2.8 Mtr. Long MS Channel of Size 100x50x50x6mm for DT support
0.6 Mtr. Long MS Channel of Size 100x50x50x6mm for DT support
2.8 Mtr. Long MS Channel of Size 75x50x50x6mm for GO, DO, LA & GO pipe
2.8 Mtr. Long MS Angle of Size 65x65x6mm for GO handle.
SP Top X-arm of 0.3 Mtr. Long MS Channel of Size 75x40x40x6mm
SP bottom X-arm of 1.2 Mtr. Long MS Channel of Size 75x40x40x6mm
SP Guard X-arm of 1.6 Mtr. Long MS Angle of Size 65x65x6 mm.
DP Top X-arm of 2.2 Mtr. Long MS Channel of Size 75x40x40x6mm.
DP Guard X-arm of 2.5 Mtr. Long MS Angle of Size 65x65x6 mm.
2.5 Mtr. Long MS Channel of Size 75x50x50x6mm for line GO, DO,
1.7 Mtr. Long MS Channel of Size 75x50x50x6mm for11kv line tapping
2.0 Mtr. Long MS Angle of Size 65x65x6mm for tapping guard
0.95mtr. Long MS Angle of size 50x50x6 mm for LT line
0.55mtr. Long MS Angle of size 50x50x6 mm for LT line
11KV polymeric disc insulator with fittings
11KV Polymetric Pin Insulator
LT Shackle insulator
Stay Set Complete
A.C.S.R. (6/1/2.59 mm)
GI Wire (10SWG)
11 KV G.O.S. 3-phase
11 KV D.O.F. 3-phase
11 KV L.A. Set
Cradle Guard (HT)
Danger plate
Erection of barbed wire per pole
63 KVA Distribution Transformer
Providing three phase Service Connection
Construction of Sub-station Fencing with barbed wire, errection supply & errection of barbed wire fencing of MS Angle ( 6Nos. 65x65x6mm & 4Nos . 50x50x6 mm)& provision of gate ( to be fabricated by 35x35x6 mm M.S. Angle-20x6mm M.S. Flat ) fixed with supports of fencing belted at top by 35x35x6 mm M.S. Anglethrough out with provision of hings & locking arragement etc. as per approved design & drawing of ED-KCP .
Earthing with GI pipe 2.5mtr long and 40 mm dia, including excavation, refilling with alternate layer of salt and charcoal as per drawing (excluding supply of GI pipe, salt and charcoal, GI wire, Nuts & bolts etc. As required).
Carriage of the following
Carriage of 8(eight) nos. 63 KVA transformer from store Division A.D. Nagar to Dasda Store yard by mechanical transport including Loading, Un-loading & Stacking etc. as required. .
Carriage of 8.0/9.00 mtr. Length of Galvonized Steel Pole by mechanical transport from Dasda Electrical Sub-Divisional sitestore to work site vis-a-vis including loading, unloading & stacking as required.
a)Upto the lead range of 25 km
i) Beyond 8(eight) poles (250 Nos.)
Carriage of 9.00 mtr. Length of PCC Pole by mechanical transport from Dasda Electrical Sub-Divisional sitestore to work site vis-a-vis including loading, unloading & stacking as required.
a) upto lead of 25 km
i)For maximum 4(four) poles
Carriage of 2(two) nos. 63 KVA transformer from Dasda Electrical Storeyard to work site by mechanical transport including Loading, Un-loading & Stacking etc. as required. .
a)upto the lead range of 25 km
Carriage of line materials such as Cable, AAC, AAAC, ACSR, GI wire, Cross arm, stay set, insulators etc by mechanical transport from the electrical Sub-Divisional sitestore to working site vis-a-vis including loading, unloading & stacking as required.
a)Beyond 25 km upto lead of 50 km
Carriage of materials such as G.O.S, D.O.F, LA etc by mechanical transport from the electrical Sub-Divisional sitestore to working site vis-a-vis including loading, unloading & stacking as required.
a)Beyond 25 km upto lead of 50 km
Manual carriage of 8.00 / 9.00 mtr. Length of Steel tubuler Pole approx. 2km Each pole from Jaliram to Sachindra Parra i/e including loading, unloading & stacking as required.
Manual carriage of line materials approx. 2km such as Cable, AAC, AAAC, ACSR, GI wire, Cross arm, stay set, insulators etc from Jaliram to Sachindra Parra including loading, unloading & stacking as required.
Manually carriage of 63KVA DT with 'Deo' river crossing approx. 500 mtrs. Each pole from Ananda Bazar to Bogichandra including loading, unloading & stacking as required.
Fabrication & Gungle cutting
Fabrication of all X-Arm by M.S Angle, MS Channel etc.
Jungle cutting
Fitting, fixing of Sub-station cable jointing & cutout.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .