Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.3 LAccepted-AOC 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹1.3 Cr+₹33.4 L (33.6%)Rejected-Finance 203 B CHAHBAI BAREILLY UP 243001 | BAREILLY | BAREILLY | UP | 243001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹1.4 Cr+₹39.3 L (39.6%)Rejected-Finance A 91 DEFENCE COLONY AGRA CANTT AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹1.4 Cr+₹44.7 L (45.0%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
17 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Bareilly
HQ CWE(AF) Bareilly-243002
WORK SERVICES FOR INSTALLATION OF STATIC AIRCRAFT ARRESTING GEARS AT AF STN BAREILLY
2022_MES_533073_2
81321/E8
Open Tender
Civil Works
Item Rate
180 days
Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE(AF) Bareilly
₹2.1 L
Yes
24 Mar 2023
21 Jan 2023
20 Feb 2023
21 Jan 2023
17 Feb 2023
4 Feb 2023
22 Jan 2023 - 23 Jan 2023
Amount
Excavating over areas (manual excavation), n exc 1.5 m deep and getting out in soft & loose soil complete all as specified and directed.
Excavating in trenches (manual excavation), n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out on soft and loose soil for depth for laying cables or foundation of electric pole / Stay assembly and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
Spreading and levelling of earth and well ramming in layers n.exc 25 cm incl watering and compaction of surplus soils obtained from item No. 1 to 4 above complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exc 25 cm in soil complete all as specified and directed
M&L for PCC 1:3:6 type C2 (using 40 mm crushed stone aggregate) as in foundations, filling and mass concrete and complete all as specified and directed.
M&L for RCC M-35 Design mix (20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and as specified and directed.
All as per item No 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and complete all as specified and directed.
M&L for cement concrete cast in situ type B1 1:2:4 (using 20 mm crushed stone aggregate) as in bedding to pipes, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for loose filling with bajri/ gravel 5 to 10mm size in layers n exc 15cm thick each layer spreaded, levelled and rammed incl watering complete all as specified and directed.( Compacted thickness will only be measured and paid).
S&F for Mild steel bolts of dia of neck exc 12mm but n exc 20mm, purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long and including provision of temporary templates made out of mild steel plates min 3 mm thick complete all as spd and directed.
S&F for mild steel tubes as in sleeves for foundation bolts, cut to required length incl bends etc. ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St- 240 complete all as specified and directed.
M&L for roof trusses (framed), trussed, pirlins, crane gantries, rails and fastening and heavy bracket framing (wind tie beam, Beam, tee, angle, channel, plates or flat sections, bolts) including distancepieces, cleats etc conforming to Fe-410 W (Gde-E- 250) quality- A, Complete all as spd and directed.
M&L for Preperation of new steel surfaces of any discription, exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as spd and directed.
S&F 1.60 mm thick Corrugated Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as spd and directed.
Removing excavated material /soil not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete including meking berms embankments all as specified and directed.
M&L for Formwork (fair finished)to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for 250mm Nominal bore PVC pipe having an actual pipe OD of 273mm, pressure rating 140 Psi, all as per IS-4985 (2000) jointed with PVC solvent cement & fixed on RCC pillers as per drg (RCC shall be paid saperately) complete all as specified and directed.
Preparation of new Concrete surfaces and applying two coats of water base paint over a coat of primer in specified pattern and colour complete incl all as specified and as directed. Note : Colour scheme and design shall be as per user's requirment.
S&F for mild steel works in bands, straps, supports or stays including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers including temporary templates for installation of anchor bolts in foundation and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for providing heavy duty crane with operator & helper of capacity ( 6 to 10 Ton)for installation of BAK-12 and Roller edge sieve assembly at site by using spacer bars and all related assesory of Crane and required manpower for manning etc (21 days at site) complete all as specified and directed.
S&F for wire netting of galvanised steel wire 1.40mm dia, size of mesh 20mm fixed with tinned tacks of wire staples complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting with 8 to 10 ton power roller complete all as specified and directed.
M&L for 250 mm thick (compacted thickness) Hardcore of broken stone or boulders of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 10 cm thick each layer, watered and rolled with 8 to 12 ton power roller to a true surface to required gradient and camber as required complete all as specified and directed.
M&L for 250 mm thick (compacted thickness) PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of road complete all as directed.
M&L for 250 mm thick (compacted thickness) PCC , M-25 design mix (using 20mm graded crushed stone aggregate) casted in panels as in pavement of road incl all necessary formwok complete all as specified & directed.
M&L for Finishing the surface concrete by brooming while the concrete is still green complete all as specified and directed.
M&L for Forming Construction joint 10mm wide and 30mm deep by cutting with diamond cutter and filled with sealing compound Grade 'A' complete all as specified and directed.
M&L for forming Contraction(Dummy) joint 65mm deep x10mm wide by cutting with diamond cutter and filled by sealing compound grade 'A' complete all as specified and directed.
M&L 150 mm thick PCC 1:4:8 type D-2 (using 40mm graded cushed stone aggregate in sub base of floor complete all as specified and directed.
M&L for 150mm thick M-25 design mix (using 12.50mm graded crushed stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete as in Tape sweep area finished even and smooth complete all as specified and directed.
M&L reinforced concrete 300mm bore pipes, class NP2, laid and jointed complete with collars including cement concrete 1:3:6 type C-2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed.
M&L for forming 20 mm wide expansion joint , filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for 250 mm thick concrete slab and complete all as specified and directed.
Supply, laying, jointed and testing LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables 1100 Volts grade with stranded aluminium conductor of size16 sq mm 4 core, laid in trenches/ drawn through pipe/ laid under road / drains / path complete all as specified and directed.
M & L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed.
M & L for laying brick as in protection covers over cables using well burnt sub class 'B' old size bricks in trenches over sand cushioning complete all as specified and directed.
S&F for MCB Triple pole and neutral, 415 Volts, 32 Amps, breaking capacity, 10 KA, 'C' series etc complete all specified and directed. Make :- Legrand, Schneider, ABB
S&F for MCB Single pole and neutral, 240 Volts, 32 Amps, breaking capacity, 10 KA, 'C' series etc complete all specified and directed. Make :- Legrand, Schneider, ABB
S&F for MCB single pole, 240 Volts, 6 to 32 Amps, breaking capacity, 10 KA, 'C' series etc complete all specified and directed. Make :- Legrand, Schneider, ABB
M&L for sub main wiring complete with 2 single core multi stranded copper conductor 4.0 Sqmm (Nominal area) FR-LSH, PVC insulated unsheathed cable drawn in and including medium grade PVC conduit ISI Marked not less than 20 mm dia concealed including making good distrubed surface, of wall, including single core multi stranded copper conductor 4.0 Sqmm size as earth wire drawn in same conduit complete all as specified and directed. Make :- RR Kable, Finolex, Havells, Plaza
M&L for Point Wiring for one light point controlled by one way switch complete with 1.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawn in and including concealed non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia but shall be increased as per actual site reqmt in accordance with clause no 19.125 of SSR part I fixed concealed / recessed in wall / ceiling etc including1.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts gradeas earth continuity wire including MS sunken pressed steel terminal boxes of suitable size, made of sheet 1.6mm thick with 3.0 mm thick bakelite sheet top cover for complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with pact and corrosion resistant complete with driver and lamp complete all as specified and directed.
M&L for Point Wiring complete with 2.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawn in and including concealed non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia but shall be increased as per actual site reqmt in accordance with clause no 19.125 of SSR part I fixed concealed / recessed in wall / ceiling etc including 2.5 Sqmm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts gradeas earth continuity wire including MS sunken pressed steel terminal boxes of suitable size , made of sheet 1.6mm thick with 3.0 mm thick bakelite sheet top cover one 3 pin 15 or 16 Amp socket outlet on independent board complete all as specified and directed.
S&F for socket outlet 2 in 1, 6 pin, 6 and 16 amps flush type complete all as specified and directed.
S&F for switch piano flush type, 15/16 amps, singe pole, one way all as specified and directed.
M & L for Chemical Earthing with copper grounding earth rod of length not less than 3.00 metre, dia 17.20 mm molecularly bonded with 250 micron copper, burried directly in ground, earth pit not less than 3.20 metres below normal ground level and size of pit hole shall be of 125 mm dia, with top edge of the earth rod not less than 0.75 metres below normal ground level, earth rod surrounded by at least 30 Kg of ground enhancing material i.e. 25 Kg of Earthcon and 5 Kg Tarac compound to reduce soil resistivity, upto 2.80 metres height and including connected to copper strip 32 X 6 mm (upto 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 40 mm bore light grade pipe from electrode and upto and including the earth test point of galvanised iron / steel of size 75 x 75 x 25 mm test point 15 mm bore watering pipe light grade GI funnel, wire mesh including necessary earthwork and excavation, removal of surplus soil to a distance not exc. 50 m, PCC pit in PCC (1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. MAKE: - Truepower Earthings, Sabo systems Pvt Ltd, Jaipuria Brothers, Inter Tech India Ltd.
NOTE:- Additional earthing compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .