| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.7 LAccepted-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | ₹19.7 L | L-1 | Accepted-AOC Awarded being L-1 |
| 2 | L-2₹20.2 L+₹47,293 (2.40%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | ₹20.2 L+₹47,293 (2.40%) | L-2 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY |
| 3 | L-3₹21.1 L+₹1.4 L (7.13%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹21.1 L+₹1.4 L (7.13%) | L-3 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY |
| 4 | L-4₹24.1 L+₹4.4 L (22.2%)Rejected-Finance 408 409 HAASH BUSINESS CENTER NR ANKUR SCHOOL FATEHPURA PALDI AHMEDABAD 380007 | AHMADABAD | GUJARAT | 380007 | ₹24.1 L+₹4.4 L (22.2%) | L-4 | Rejected-Finance FOUND ELIGIBLE AFTER TECHNICAL SCRUTINY |
| 5 | Rejected-Technical 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | - | - | Rejected-Technical NOT ELIGIBLE |
Tender Value
₹24.2 L
EMD Value
₹48,336
Closing Date
5 Oct 2020, 6:00 pmClosed
Asstt.Gen.Manager (E-E)
C.A.Porbandar-360577
Operation and Maintenance contract for the E and M Installations i/c supply of GLF spares at C.A. Keshod for 2 years (2020-22)
2020_AAI_53557_2
AAI/KES/AGM(E-E)/eNIT-01/20-21
Open Tender
Electrical Works
Item Rate
730 days
C.A.Keshod
as per NIT
19 documents required · 19 mandatory
₹1,180
Yes
AAI
₹48,336
Yes
1 Jun 2022
26 Sept 2020
12 Oct 2020
26 Sept 2020
5 Oct 2020
26 Sept 2020
26 Sept 2020 - 30 Sept 2020
Amount
Annual Periodical Maintenance of E&M Installations at Terminal Building, Power House & other ancillary buildings, AAI residential colony complete with operation & maintenance of DG sets, Pumps, GLF installations comprising runway edge, taxiways, apron edge lighting, approach lighting, PAPI system, CCR panels, apron high mast lighting all as required to ensure un-interrupted services including minor repairing works as detailed in the technical specifications, terms & conditions of the contract by deputing sufficient manpower round the clock in one shift/General shift for attending to complaints/faults/breakdowns, ensuring serviceability & satisfactory working condition of the system, preventive maintnenance, upkeeping of maintenance records/documentation etc.,on all working days including Sundays and holidays and also as & when required basis.
Annual Comprehensive maintenance contract including repair/replacement of all parts of various makes of A/C units at different locations in Airport premises complete as required as specified for following capacity & type (Each one Set/Job per month).
1.0 Ton Split type (1-Ø,50Hz) (2 Nos. X 24 months = 24 jobs.)
1.5 Ton Split type (1-Ø,50Hz) (11 Nos.X 24 months + 4 Nos.x16 months) = 328 jobs.)
2 Ton Split type (1-Ø,50Hz) (2 Nos.X 24 months = 48 jobs.)
5 Ton Cassette type (3-Ø,50Hz) (5 nos. X 24 months = 120 jobs.)
Annual comprehensive maintenance contract including repair/replacement of all parts for Voltas/Usha make water Cooler at different locations in airport premises complete as per site requirement for following capacity & make (Each one Set/Job per month).
40/50/80 ltrs water Cooler (Usha make) (5Nos. x 24 months= 120 Jobs)
150/150 ltrs water Cooler (Blue Star make) (1 Nos. x 16 months= 16 Jobs)
Annual Comprehensive maintenance contract including consumable items and all spare parts i/c. membrane etc. of all makes of RO unit at different locations in airport premises complete as per site requirement for following type & capacity (Each Job per month)
25/40 LPH RO unit (5 Nos. x 24 months = 120 Job)
50 LPH RO unit ( 1 No. x 16 months = 1 JOB)
Dismantling, Shifting & Reinstallation of 1.5 / 2.0 /5.0 Ton Capacity of all makes & types of A/C unit in airport premises (Job i/c piping work upto 2 feet, Gas charging etc complete as required ).
Servicing, repairing, rewinding and replacement of defective part like bearings, bushing etc. and also transporting from site to contractors workshop & back to site, testing and commissioning etc. complete as per site requirement for the following motors ( Dismantle material belongs to Contractor)
Ceiling Fan/Wall Fan (1-Phase, 50Hz, 240V AC)
Exhaust fan Up to 450 mm (1-Phase, 50Hz,240V AC )
3 HP to 5 HP pump motor sets (3-Phase, 50Hz,415V AC )
Servicing, repairing and replacement of defective part like Relay, PCB etc. of Electronic voltage stabilizer for AC units including transportation from site to contractor's workshop & back to site. (Dismantle Material belongs to contractor).
Calibration of CCR & Sensitivity of relay on 4 KW to 20 KW CCR of NASU/AMA make CCR including submitting reports etc., complete as required.
Calibration of PAPI Clinometer etc. complete as required.
Inspection, servicing, setting, testing, adjustment, calibration and submission of calibration certificate of following instruments including minor repairs etc. Complete as per site requirement.
Electronic IDMT Relay
Voltmeter Digital suitable for AC supply.
Ammeter Digital suitable for AC supply.
Digital Power Factor (Cos Ø) Meter/frequency meter
Painting of light poles with aluminium paint of (2 coats) of approved brand and make, along with one coat of primer, including cleaning the surface all as required. Painting of each pole will be treated as one job.
Decoration of Terminal building facia with LED serial lighting and RGB pattern lighting on special occasions/nationally important days/festivals as per the requirements shown below - (i) Minimum no. of LED serial lighting - not less than 5000 LED lights. (ii) Pixel Chaser light batten running linearly on the top of the building, ATC tower, entry gate walls for a length of not more than 350 m. (iii) Halogen focus lights (Green or Yellow) for trees around terminal building - 10 Nos. Type of Decoration will be as per the theme of occasions and upto the statisfaction of the Engineer In-charge/Airport Director.
Independence day /Republic day / AAI foundation day / Christmas / New Year (Starting from 18.00 hrs. on the Day before the Occasions to till 06.00 hrs on the day after the Occasions) Each occasion in an year shall be treated as one Job.
Execution of Complete items of CPWD Delhi schedule of rates (E&M) 2018.[Up to a Ceiling limit of Rs. 60,000 without GST]. The materials used for executing the DSR items shall be as per the approved make list of AAI, as enclosed with the tender document.
Supply of HT insulation tape roll of size 19mmX 0.9mm of length not less then 9 Mtr
Supply of LT insulation tape roll of colour red,green,blue and black of length not less then 9 Mtr per roll
Supply of 3/9/12 W LED bulb suitable for operation on 230 V, 50Hz, AC AC supply complete etc as required. (Make: Havells, Code: LHLDEUHEML8R009 or Equivalent)
200 W 6.6 A bipin runway halogen lamp
Lamp holder for runway/taxiway halogen lamps
Clear lens suitable for AMA MK-III PAPI Unit (Make- AMA)
Red filter suitable for AMA MK-III PAPI Unit (Make- AMA)
Aluminium Reflector suitable for AMA MK-III PAPI Unit (Make- AMA)
Air Filter suitable for AMA MK-III PAPI Unit (Make- AMA)
Upper Breakable Coupling (Upper Breakable Point + Upper Leg Plate) suitable for AMA MK-III PAPI Unit (Make- AMA)
Lower breakable coupling for AMA make PAPI
Upper leg pipe (LH threaded) for AMA make PAPI
Lower Leg Pipe for AMA make PAPI
Locking Nut for upper pipe (RH threaded) for AMA make PAPI
Locking Nut for lower pipe(LH threaded) for AMA make PAPI
Threaded adjustment sleeves (Middle Nut) for AMA make PAPI
Supply of TDS meter
Digital Clamp Meter/ Tongtester suitable for DC/AC/TRMS (Make-Meco, Model-1080-TRMS)
Digital Insulation Tester with DC test voltage-500 V, 0-200 M ohms Range, and Resolution-0.1 M ohms (Make-Meco, Model-DIT 99C)
Supply of Earth Tester set
Supply of driver for existing LED signage board Suitable to operate inbuilt dual circuit having variable current 2.8 A to 6.6 Amp with auto changeover facility. The driver should be able to drive LED strips of 0.5 Watts Osram LED's assembled on aluminium PCB of size 700mm X 20mm and having 11 LED's per PCB for boards. from 5 strips to 20 strips.
Supply of LED strip with high luminous long life typically 50,000 hrs type, 0.5 watts Osram LED's assembled on aluminum PCB of size 700mm X 20mm X 2mm and having 11 LED's per PCB for boards. (make- Poshdecor) At one end single non-reversible jack to be provided for easy replacement of LED without tools at site.
Supply of loop wire with non-reversible male jack of length 1 Mtr each for LED strips.
1000 W Halogen Lamp for High mast
Supply of 12 V, 180 Ah SMF lead acid batteries for DG Set
Supply of PAPI calibration stick holder/bracket with cover all as reqd. (as per sample)
Supply of halogen lamp holder suitable for AMA make PAPI unit complete with insulated leads etc. as reqd. (as per sample)
Supply of following Plug in type relays suitable for 20/4 KW CCR
48 VDC suitable for 11 pin socket
Supply of TI 300 Trip indication fuses for 20/4 KW CCR.
Supply of following High speed Semi-conductor Protection Fuses :
GS 1000/100 ( (Suitable for 20 KW CCR )
GSB 50 (Suitable for 4 KW)
Supply of following HRC Fuse Link :
100 Amps (2 Nos each for 20 KW CCR)
32 Amps (Suitable for 20 KW & 4 KW CCR)
Power Transistors MJ11016 suitable for all rating of CCRs.
CENTRE TAP ENGINEERING
Manish Electricals
Yash Energy Pvt. Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .